1SDA066809R1 ABB - XT1B 160 TMD 160-1600 3p F F

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
4ff9b03b-1cf2-4837-8d24-93dc6121834d Italy
Simplified SCIP:
376db5fd-877a-4d16-90ca-1445f9cc3141 Germany
4da9f204-50cc-48b7-b553-1da097a7c855 Finland
d5ace655-c799-4282-b3ae-2598d9667b08 Netherlands
a6bea1a2-aa2e-4fe2-bcab-e3f7f257dee4 Germany
9675f1d6-1131-47e6-bd74-fbc792671b86 Denmark
1c694b3b-5fe7-4a27-b730-11e35f757d5e Germany
d7c05fd5-cc87-4458-8302-2f636925db52 Croatia
ef885e92-d9b1-45c6-8cb6-c4ad6bb41325 Czech Republic
b47804c6-d053-4df3-b4c0-7c0fa2a57582 Poland
204e69d2-52b6-4c7b-82d5-984ad6f0f7a8 Norway
6b900579-62ee-4ae6-a47c-92aae85ceef4 Poland
c5f40fc3-0ccb-4d26-9c25-78659538a6eb Germany
9c041414-51e7-418a-be70-326cd293602c Germany
3d472ef2-2bb2-43b6-ada4-c165d9ff695d France
6ab977b3-e668-479a-b7d7-7aafb217dbf7 Netherlands
83fa4ab8-1066-451f-a5c6-3227f47b9f96 Spain
a788f342-f7f6-4916-be29-4fee5c9d7806 Netherlands
66fc5a77-91a7-4570-9d07-534457120ddc Netherlands
8bf595ce-3c04-4fb3-a7e8-898a7663ba35 Netherlands
66a3997e-83ef-40cf-ba5f-5ec5ca01372c Estonia
ad0a0ab9-ebde-471a-9cb3-0296bc863d67 Greece
ad2768e5-aa41-4d1e-8d83-bd13e0d23b34 Portugal
7b0da51d-f9cc-40f1-ac31-f8b0ab9af686 Bulgaria
8c92815f-fcb1-4f59-9a66-c01580e417a2 Sweden
845a2832-1626-48c6-b53d-7f7eaa93c390 Poland
d1422ba9-8bd5-4eb1-a791-d8c3f4d6901f France
e29f066c-15c8-4974-954d-4bc2a7fdaee4 Sweden
376db5fd-877a-4d16-90ca-1445f9cc3141 Germany
4da9f204-50cc-48b7-b553-1da097a7c855 Finland
d5ace655-c799-4282-b3ae-2598d9667b08 Netherlands
a6bea1a2-aa2e-4fe2-bcab-e3f7f257dee4 Germany
9675f1d6-1131-47e6-bd74-fbc792671b86 Denmark
1c694b3b-5fe7-4a27-b730-11e35f757d5e Germany
d7c05fd5-cc87-4458-8302-2f636925db52 Croatia
ef885e92-d9b1-45c6-8cb6-c4ad6bb41325 Czech Republic
b47804c6-d053-4df3-b4c0-7c0fa2a57582 Poland
204e69d2-52b6-4c7b-82d5-984ad6f0f7a8 Norway

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE3160AFF000XXX
E-Number (Finland):
3638199
E-Number (Norway):
4309610
EAN:
8015644694494
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.139 kg
Package Level 1 EAN:
8015644694494

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 15 W
Rated Current (In):
160 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1600 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
112...160 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
Est. delivery between and    
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Sale price1,718.00 kr
1-year warranty
FREE WORDWIDE SHIPPING
Condition:
1,718.00 kr
0.00 kr
0.00 kr
Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
4ff9b03b-1cf2-4837-8d24-93dc6121834d Italy
Simplified SCIP:
376db5fd-877a-4d16-90ca-1445f9cc3141 Germany
4da9f204-50cc-48b7-b553-1da097a7c855 Finland
d5ace655-c799-4282-b3ae-2598d9667b08 Netherlands
a6bea1a2-aa2e-4fe2-bcab-e3f7f257dee4 Germany
9675f1d6-1131-47e6-bd74-fbc792671b86 Denmark
1c694b3b-5fe7-4a27-b730-11e35f757d5e Germany
d7c05fd5-cc87-4458-8302-2f636925db52 Croatia
ef885e92-d9b1-45c6-8cb6-c4ad6bb41325 Czech Republic
b47804c6-d053-4df3-b4c0-7c0fa2a57582 Poland
204e69d2-52b6-4c7b-82d5-984ad6f0f7a8 Norway
6b900579-62ee-4ae6-a47c-92aae85ceef4 Poland
c5f40fc3-0ccb-4d26-9c25-78659538a6eb Germany
9c041414-51e7-418a-be70-326cd293602c Germany
3d472ef2-2bb2-43b6-ada4-c165d9ff695d France
6ab977b3-e668-479a-b7d7-7aafb217dbf7 Netherlands
83fa4ab8-1066-451f-a5c6-3227f47b9f96 Spain
a788f342-f7f6-4916-be29-4fee5c9d7806 Netherlands
66fc5a77-91a7-4570-9d07-534457120ddc Netherlands
8bf595ce-3c04-4fb3-a7e8-898a7663ba35 Netherlands
66a3997e-83ef-40cf-ba5f-5ec5ca01372c Estonia
ad0a0ab9-ebde-471a-9cb3-0296bc863d67 Greece
ad2768e5-aa41-4d1e-8d83-bd13e0d23b34 Portugal
7b0da51d-f9cc-40f1-ac31-f8b0ab9af686 Bulgaria
8c92815f-fcb1-4f59-9a66-c01580e417a2 Sweden
845a2832-1626-48c6-b53d-7f7eaa93c390 Poland
d1422ba9-8bd5-4eb1-a791-d8c3f4d6901f France
e29f066c-15c8-4974-954d-4bc2a7fdaee4 Sweden
376db5fd-877a-4d16-90ca-1445f9cc3141 Germany
4da9f204-50cc-48b7-b553-1da097a7c855 Finland
d5ace655-c799-4282-b3ae-2598d9667b08 Netherlands
a6bea1a2-aa2e-4fe2-bcab-e3f7f257dee4 Germany
9675f1d6-1131-47e6-bd74-fbc792671b86 Denmark
1c694b3b-5fe7-4a27-b730-11e35f757d5e Germany
d7c05fd5-cc87-4458-8302-2f636925db52 Croatia
ef885e92-d9b1-45c6-8cb6-c4ad6bb41325 Czech Republic
b47804c6-d053-4df3-b4c0-7c0fa2a57582 Poland
204e69d2-52b6-4c7b-82d5-984ad6f0f7a8 Norway

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1BE3160AFF000XXX
E-Number (Finland):
3638199
E-Number (Norway):
4309610
EAN:
8015644694494
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
76.2 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.139 kg
Package Level 1 EAN:
8015644694494

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
3P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 15 W
Rated Current (In):
160 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1600 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA
(230 V AC) 25 kA
(240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
112...160 A
Short-Circuit Performance Level:
B
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator