1SCA115235R1001 ABB - OS63GB03P

ABB EcoSolutions

ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
276c6185-c1ee-47bd-9b1e-75a8c97d6cd2 Finland
Simplified SCIP:
fd9a7bba-00f8-4c81-b941-7ad0753b5bbb Germany
6812dbe1-1150-4293-b974-ee950d6d0221 Portugal
078ab20a-04e0-4807-9bd1-efa20f408e40 Greece
e643d890-fa79-4b19-9928-3965c826bcd5 Poland
171e9a93-4054-4745-83dd-5202c99aeaea Croatia
b0681c26-5c95-403a-b523-5914bca24ca6 Estonia
df6484a6-3685-4bad-8034-49cd164ffffe Hungary
a0596062-9673-4901-8683-3cdadd96498e Belgium
14f98645-b00d-4135-ad3b-c3dd8ba00a03 Spain
af65cd42-a9c7-4c01-8098-a5b57a473cc6 Bulgaria
346cd679-4dde-4b81-973d-db4d6221bd47 Sweden
c2a5192d-69df-46d0-a798-e99e1633c028 Poland
5457b829-de7d-4f29-bcac-92279e336ce7 Germany
065650d7-8d57-48c7-9cdf-146f15903ff0 Sweden
bc8d5d36-1895-4086-949b-dee274f0c354 France
b72f3329-999a-400a-85bc-ac375592c6a6 France
da9cbd62-e4b8-4531-ba25-819f60402784 Hungary
ad111f6d-6b59-4baa-a486-33609579a7dd Czech Republic
7e47b1f5-1e0a-450e-bb92-9f07725f8c60 Denmark
890b5100-677a-44e9-94b1-96fcf0da07ff Germany
587d4a99-522e-4394-a8e6-8fb372105cef Poland
698220c4-4057-4bd4-a914-6a99ca13f4dd Norway
51d2a618-474a-4c3e-a7c3-037daa2a402b Italy
b3ad6111-37ed-4af8-bbe2-d1262577e7f0 Belgium
8d825642-45d5-469d-b649-6ae045f49488 Germany
b62e8908-beef-4ae8-952a-7c74b4433ccf Netherlands
95d4a7ed-cee7-499e-9871-b2adc6dd27ac Germany
fd9a7bba-00f8-4c81-b941-7ad0753b5bbb Germany
6812dbe1-1150-4293-b974-ee950d6d0221 Portugal
078ab20a-04e0-4807-9bd1-efa20f408e40 Greece
e643d890-fa79-4b19-9928-3965c826bcd5 Poland
171e9a93-4054-4745-83dd-5202c99aeaea Croatia
b0681c26-5c95-403a-b523-5914bca24ca6 Estonia
df6484a6-3685-4bad-8034-49cd164ffffe Hungary
a0596062-9673-4901-8683-3cdadd96498e Belgium
14f98645-b00d-4135-ad3b-c3dd8ba00a03 Spain
af65cd42-a9c7-4c01-8098-a5b57a473cc6 Bulgaria

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Mechanical Drawings:
Environmental Product Declaration - EPD:

Environmental

Pollution Degree:
3

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080
Country or Territory of Origin:
Finland

Dimensions

Product Net Width:
112 mm
Product Net Height:
125 mm
Product Net Depth / Length:
109 mm
Product Net Weight:
1.18 kg
2.6 lb
1.18 kg
2.6 lb

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
170 mm
6.7 in
170 mm
6.7 in
Package Level 1 Depth / Length:
190 mm
7.5 in
190 mm
7.5 in
Package Level 1 Height:
145 mm
5.7 in
145 mm
5.7 in
Package Level 1 Gross Weight:
1.3 kg
2.9 lb
1.3 kg
2.9 lb
Package Level 1 EAN:
6417019476605

Technical

Cable Cross-Section:
2.5 ... 25 mm²
Connecting Capacity:
Stranded 2.5 … 25 mm²
Flexible 2.5 … 25 mm²
Stranded 2.5 … 25 mm²
Flexible 2.5 … 25 mm²
Conventional Free-air Thermal Current (Ith):
Θ = 40 °C 63 A
Conventional Thermal Current (Ithe):
Fully Enclosed 63 A
Fuse Size:
A2-A3
Fuse System:
British Standard
Handle Type:
Pistol handle and shaft included
Mounting Type:
Base mounting
Number of Poles:
3P
Operating Mode:
Front Operated
Pollution Degree:
3
Position of Line Terminals:
Top In - Bottom Out, Bottom In - Top Out
Power Loss:
at Rated Current 2 W
Rated Conditional Short-Circuit Current (Inc):
(690 V) 80 kA
Rated Current (In):
Main Circuit 63 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current AC-21A (Ie):
(500 V) 63 A
(690 V) 63 A
(500 V) 63 A
(690 V) 63 A
Rated Operational Current AC-22A (Ie):
(500 V) 63 A
(690 V) 63 A
(500 V) 63 A
(690 V) 63 A
Rated Operational Current AC-23A (Ie):
(500 V) 63 A
(690 V) 63 A
(500 V) 63 A
(690 V) 63 A
Rated Operational Power AC-23A (Pe):
(220 ... 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 30 kW
(500 V) 37 kW
(690 V) 55 kW
(220 ... 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 30 kW
(500 V) 37 kW
(690 V) 55 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 2.5 kiloampere rms
Recommended Screw Driver:
Main Circuit Hexagon 4
Standards:
IEC 60947-3
Switches Operating Mechanism:
03 (Left Side)
Terminal Type:
Screw Terminals
Tightening Torque:
3 N·m
4 N·m
3 N·m
4 N·m
Wire Stripping Length:
Main Circuit 12 mm
Main Circuit 0.47 in
Main Circuit 12 mm
Main Circuit 0.47 in

Technical UL/CSA

Wire Stripping Length:
Main Circuit 12 mm
Main Circuit 0.47 in
Main Circuit 12 mm
Main Circuit 0.47 in
Recommended Screw Driver:
Main Circuit Hexagon 4
Tightening Torque:
3 N·m
4 N·m
3 N·m
4 N·m

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
ETIM 9:
EC001040 - Fuse switch disconnector
ETIM 10:
EC001040 - Fuse switch disconnector
UNSPSC:
39122233
IDEA Granular Category Code (IGCC):
5291 >> Fuse switch disconnector
eClass:
V11.1 : 27371401
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
Price on request
Ask for quote
   

Notify Me When Available

ABB EcoSolutions

ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
276c6185-c1ee-47bd-9b1e-75a8c97d6cd2 Finland
Simplified SCIP:
fd9a7bba-00f8-4c81-b941-7ad0753b5bbb Germany
6812dbe1-1150-4293-b974-ee950d6d0221 Portugal
078ab20a-04e0-4807-9bd1-efa20f408e40 Greece
e643d890-fa79-4b19-9928-3965c826bcd5 Poland
171e9a93-4054-4745-83dd-5202c99aeaea Croatia
b0681c26-5c95-403a-b523-5914bca24ca6 Estonia
df6484a6-3685-4bad-8034-49cd164ffffe Hungary
a0596062-9673-4901-8683-3cdadd96498e Belgium
14f98645-b00d-4135-ad3b-c3dd8ba00a03 Spain
af65cd42-a9c7-4c01-8098-a5b57a473cc6 Bulgaria
346cd679-4dde-4b81-973d-db4d6221bd47 Sweden
c2a5192d-69df-46d0-a798-e99e1633c028 Poland
5457b829-de7d-4f29-bcac-92279e336ce7 Germany
065650d7-8d57-48c7-9cdf-146f15903ff0 Sweden
bc8d5d36-1895-4086-949b-dee274f0c354 France
b72f3329-999a-400a-85bc-ac375592c6a6 France
da9cbd62-e4b8-4531-ba25-819f60402784 Hungary
ad111f6d-6b59-4baa-a486-33609579a7dd Czech Republic
7e47b1f5-1e0a-450e-bb92-9f07725f8c60 Denmark
890b5100-677a-44e9-94b1-96fcf0da07ff Germany
587d4a99-522e-4394-a8e6-8fb372105cef Poland
698220c4-4057-4bd4-a914-6a99ca13f4dd Norway
51d2a618-474a-4c3e-a7c3-037daa2a402b Italy
b3ad6111-37ed-4af8-bbe2-d1262577e7f0 Belgium
8d825642-45d5-469d-b649-6ae045f49488 Germany
b62e8908-beef-4ae8-952a-7c74b4433ccf Netherlands
95d4a7ed-cee7-499e-9871-b2adc6dd27ac Germany
fd9a7bba-00f8-4c81-b941-7ad0753b5bbb Germany
6812dbe1-1150-4293-b974-ee950d6d0221 Portugal
078ab20a-04e0-4807-9bd1-efa20f408e40 Greece
e643d890-fa79-4b19-9928-3965c826bcd5 Poland
171e9a93-4054-4745-83dd-5202c99aeaea Croatia
b0681c26-5c95-403a-b523-5914bca24ca6 Estonia
df6484a6-3685-4bad-8034-49cd164ffffe Hungary
a0596062-9673-4901-8683-3cdadd96498e Belgium
14f98645-b00d-4135-ad3b-c3dd8ba00a03 Spain
af65cd42-a9c7-4c01-8098-a5b57a473cc6 Bulgaria

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Mechanical Drawings:
Environmental Product Declaration - EPD:

Environmental

Pollution Degree:
3

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85365080
Country or Territory of Origin:
Finland

Dimensions

Product Net Width:
112 mm
Product Net Height:
125 mm
Product Net Depth / Length:
109 mm
Product Net Weight:
1.18 kg
2.6 lb
1.18 kg
2.6 lb

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
170 mm
6.7 in
170 mm
6.7 in
Package Level 1 Depth / Length:
190 mm
7.5 in
190 mm
7.5 in
Package Level 1 Height:
145 mm
5.7 in
145 mm
5.7 in
Package Level 1 Gross Weight:
1.3 kg
2.9 lb
1.3 kg
2.9 lb
Package Level 1 EAN:
6417019476605

Technical

Cable Cross-Section:
2.5 ... 25 mm²
Connecting Capacity:
Stranded 2.5 … 25 mm²
Flexible 2.5 … 25 mm²
Stranded 2.5 … 25 mm²
Flexible 2.5 … 25 mm²
Conventional Free-air Thermal Current (Ith):
Θ = 40 °C 63 A
Conventional Thermal Current (Ithe):
Fully Enclosed 63 A
Fuse Size:
A2-A3
Fuse System:
British Standard
Handle Type:
Pistol handle and shaft included
Mounting Type:
Base mounting
Number of Poles:
3P
Operating Mode:
Front Operated
Pollution Degree:
3
Position of Line Terminals:
Top In - Bottom Out, Bottom In - Top Out
Power Loss:
at Rated Current 2 W
Rated Conditional Short-Circuit Current (Inc):
(690 V) 80 kA
Rated Current (In):
Main Circuit 63 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current AC-21A (Ie):
(500 V) 63 A
(690 V) 63 A
(500 V) 63 A
(690 V) 63 A
Rated Operational Current AC-22A (Ie):
(500 V) 63 A
(690 V) 63 A
(500 V) 63 A
(690 V) 63 A
Rated Operational Current AC-23A (Ie):
(500 V) 63 A
(690 V) 63 A
(500 V) 63 A
(690 V) 63 A
Rated Operational Power AC-23A (Pe):
(220 ... 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 30 kW
(500 V) 37 kW
(690 V) 55 kW
(220 ... 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 30 kW
(500 V) 37 kW
(690 V) 55 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 2.5 kiloampere rms
Recommended Screw Driver:
Main Circuit Hexagon 4
Standards:
IEC 60947-3
Switches Operating Mechanism:
03 (Left Side)
Terminal Type:
Screw Terminals
Tightening Torque:
3 N·m
4 N·m
3 N·m
4 N·m
Wire Stripping Length:
Main Circuit 12 mm
Main Circuit 0.47 in
Main Circuit 12 mm
Main Circuit 0.47 in

Technical UL/CSA

Wire Stripping Length:
Main Circuit 12 mm
Main Circuit 0.47 in
Main Circuit 12 mm
Main Circuit 0.47 in
Recommended Screw Driver:
Main Circuit Hexagon 4
Tightening Torque:
3 N·m
4 N·m
3 N·m
4 N·m

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
ETIM 9:
EC001040 - Fuse switch disconnector
ETIM 10:
EC001040 - Fuse switch disconnector
UNSPSC:
39122233
IDEA Granular Category Code (IGCC):
5291 >> Fuse switch disconnector
eClass:
V11.1 : 27371401
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
Object Classification Code:
Q
ETIM 9:
EC001040 - Fuse switch disconnector
ETIM 10:
EC001040 - Fuse switch disconnector
UNSPSC:
39122233
IDEA Granular Category Code (IGCC):
5291 >> Fuse switch disconnector
eClass:
V11.1 : 27371401
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator