Specifications
Model |
IV4-CU1 |
|||
Compatible sensor |
IV4-400CA/IV4-500CA/IV4-600CA |
|||
Supported networks |
PROFINET, EtherCAT®, TCP/IP no procedure communication, SNTP client, FTP client, SFTP client, OPC UA server, MQTT client, HTTP, HTTPS |
|||
Ethernet specifications |
Transmission speed |
100 Mbps |
||
Connector specifications |
M12 (D) 4-pin female connector |
|||
Number of connectors |
2 ports |
|||
Supported functions |
EtherCAT® |
CoE |
||
PROFINET |
Conformance Class C |
|||
Power supply |
Power supplied via connected sensor |
|||
Environmental resistance |
Enclosure rating |
IP67 *1 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 in 6 directions, 3 times respectively |
|||
Material |
Front case/back cover: PBT |
|||
Weight |
Approx. 210 g 7.41 oz |
|||
*1 Applicable only when mounted to a sensor. | ||||

Specifications
Model |
GS-T01 |
|||
Response time (ms) |
Lock / Unlock |
Response time of GS-M/GS + 110 ms + 70 ms × (number of cascaded unit -1)*1 |
||
OSSD |
Response time of GS-M/GS *2 |
|||
AUX |
Response time of GS-M/GS + 60 ms + 30 ms × (number of cascaded unit -1) |
|||
AUX (Non-safety related output) |
Output |
Transistor output × 8 |
||
Max. load current |
20 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 2 m 6.6') |
|||
Lock control input |
Approx. 2.5 mA×2 |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10% or less, Class2) |
||
Power consumption |
0.8 W |
|||
Environmental resistance |
Operating ambient temperature |
-20 to 55°C -4°F to 131°F (No freezing) |
||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25 to 70°C -13°F to 158°F(No freezing) |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Case: PBT Cable:PVC |
|||
Weight |
Approx. 290 g 10.23 oz |
|||
*1 When using the GS-71PC, the response time from "Unlock" to "Lock" increases by 200 ms per unit. | ||||



Specifications
Model |
ES-11AC*1 |
|||
Type |
AC |
|||
Operation mode |
N.O. |
|||
Indicator |
Output: Red LED |
|||
Output |
Control output |
Thyristor 240 VAC, 5 to 300 mA |
||
Disconnection alarm output |
― |
|||
Leakage current (OFF time) |
0.2 mA max. |
|||
Response time |
10 ms max. |
|||
Temperature characteristics |
±8% of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Rating |
Power voltage |
85 to 240 VAC 50/60 Hz |
||
Current/power consumption |
1 VA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 125 g |
|||
*1 This product does not comply with the EMC directive. | ||||

Specifications
Model |
CA-LAR8 |
|||
Focal point |
8.5 mm 0.33" |
|||
F-stop range (aperture) |
F1.8 to F16 |
|||
Minimum WD |
0.05 m 0.16' |
|||
Mount |
C-mount |
|||
Filter size |
M46 × P0.75 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
0.02% |
|||
Resolving power |
250 cycles/mm at center, |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Lens coating |
WIDE, BAND MULTICOATING |
|||
Weight |
Approx. 180 g 6.35 oz |
|||


Specifications
Model |
ER-GW18P |
|||
Type |
Weld-resistant all-metal shielded type Screw type M18 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
10 mm 0.39" ±10% *2 |
||
With distance switching (Mode 2) |
5 mm 0.20" ±10% *2 |
|||
Response frequency |
2 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
30 × 30 mm 1.18" × 1.18" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 100 mA or less for 1 output; |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +85°C -13°F to +185°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface and case: SUS303 with ceramic coating, Button: PBT, Nut: SUS303 with ceramic coating, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 110 g 3.88 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
MU-N11 |
|||
Main unit/Expansion unit |
Main unit |
|||
Response time |
Depends on the connected sensor model*1 |
|||
Expansion units |
Up to 4 expansion units*2 |
|||
I/O |
Control output |
4 max., |
||
External input |
5 max., |
|||
Analog output |
1 max., |
|||
Protection circuit |
Protection against reverse power connection, |
|||
Power supply |
Power voltage |
24 VDC, ripple (P-P) 10% or less, Class 2 or LPS |
||
Current consumption |
70 mA or less (without load)*5 |
|||
Sensor |
Allowable sensor current |
150 mA or less |
||
N-bus |
Allowable passing |
1200 mA or less |
||
Environmental resistance |
Ambient temperature |
-20 to +50 °C -4 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case and dust cover: Polycarbonate |
|||
Weight |
Approx. 70 g |
|||
*1 The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model. | ||||

Specifications
Model |
EM-038 |
|||
Type |
Shielded |
|||
Shape |
3.8 mm 0.15" dia Cylindrical. |
|||
Detecting distance |
0.8 mm 0.031" ±15% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
5 x 5 mm 0.20" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Output |
NPN |
|||
Control output |
NPN: 200 mA (40 V) max., Residual voltage: 1 V max. |
|||
Housing |
Stainless steel |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*1 |
||
Current consumption |
12 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 38 g (including nuts and 2-m 6.6' cable) |
|||
*1 Make sure that the power voltage stays within 10.8 V to 30 V even if it is affected by ripple effects. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FD-GD80U |
|||
Pipe size/Outer diameter |
3" (80 A) ø86 to ø92 mm ø3.39" to ø3.62" |
|||
Weight |
Approx. 0.46 kg |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
FD-EPH12 |
|||
Pipe size |
Outer diameter of pipe |
ø12 0.47" *1 |
||
Compatible outer diameter range |
Polyurethane |
12.0 ±0.15 mm |
||
Nylon |
12.0 ±0.1 mm |
|||
Pipe materials |
Resin pipe connectible to a one-touch coupling |
|||
Supported gases |
Air, nitrogen, argon, and non-corrosive gases*2 |
|||
Supported gas temperature |
−10°C to +60°C 14 to 140°F |
|||
Pressure resistance |
1 MPa |
|||
Flow rate detection principle |
Ultrasonic transmission time difference method |
|||
Flow rate specifications |
Rated flow rate |
(volume flow rate) |
250 L/min 8.83 CFM |
|
(20°C 68°F, atmospheric pressure conversion) * Initial display |
Gas at 20°C 68°F, 0.0 MPa |
|||
Gas at 20°C 68°F, 0.2 MPa |
750 L/min 26.5 CFM |
|||
Gas at 20°C 68°F, 0.4 MPa |
1250 L/min 44.1 CFM |
|||
Gas at 20°C 68°F, 0.6 MPa |
1750 L/min 61.8 CFM |
|||
Measurement accuracy |
±(2.0% of RD+1.0% of F.S.)*3*4 |
|||
Repeatability |
Response time of 250 ms: ±2.5% of F.S.*3*5 |
|||
Pressure specifications |
Rated pressure |
−100 kPa to +0.75 MPa * However, the flow rate cannot be measured in the range of −100 to −30 kPa. |
||
Overall accuracy |
±2.0% of F.S.*3 |
|||
Repeatability |
Response time of 2.5 ms: ±0.4% of F.S. |
|||
Display resolution |
Instantaneous flow |
0.1/1 L/min |
||
Accumulated flow |
0.1/1/10/100/1000 L |
|||
Pressure |
0.1/1 kPa |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Ambient temperature |
−10°C to +60°C 14 to 140°F (no freezing) |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Sensor unit (parts that do not contact the gas) |
PBT/PAR/iron/Brass electroless nickel plating/POM/NBR/stainless steel/aluminum |
||
Flow channel (parts that contact the gas) |
PBT/Brass electroless nickel plating/NBR/nylon |
|||
Weight |
Approx. 201 g 7.09 oz |
|||
*1 To ensure stable detection, it is recommended to use a pipe inner diameter that is at least equivalent to the inner diameter of this product. | ||||

Specifications
Model |
VT-AT10 |
|||
Type |
10" attachment |
|||
Applicable product |
VT5-X10 |
|||
Note |
For switching from 10" VT3/VT2/VT Series to VT5-X10 |
|||


Specifications
Model |
MD-F5200C*1 |
|||
Type |
Marking unit (Controller + Head) |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: Fiber laser (Class 4 laser product; IEC/EN60825-1, JIS C6802, FDA (CDRH) Part 1040.10*2, GB7247.1) |
||
Wavelength |
1090 nm |
|||
Output |
50 W |
|||
Applicable regulations |
EU directive (EMC directive, machinery directive, RoHS directive), |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, Wavelength: 655 nm, Output: 1.0 mW |
|||
Marking area |
125 × 125 × 42 mm 4.92" × 4.92" × 1.65" |
|||
Standard working distance (±variable width) |
168 mm (±21 mm) 6.61" (±0.83") |
|||
Marking resolution |
2 µm 0.08 Mil |
|||
Scan speed |
Max. 12000 mm/s 472.44"/s |
|||
Character type |
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji), User fonts, True Type fonts |
||
Barcode |
CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E, CODE93 |
|||
2D code |
QR code, Micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, |
|||
Logo image |
Custom character font and logo CAD data, BMP/JPEG/PNG/TIFF |
|||
Marking conditions |
Workpiece style |
Stationary/moving marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 125 mm 0.004" to 4.92" |
|||
No. of registered programs |
Max. 2000 programs |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O, Connector control I/O |
|||
Interface |
RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*3 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4.0 m 13.1' |
|||
Cooling method |
Controller: Forced air cooling, Head: Natural air cooling |
|||
Rated voltage and power consumption |
Single-phase 100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, Max. 750 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 25.5 kg |
|||
*1 Type equipped with contactor control terminal block | ||||

Specifications
Model |
SV2-M010AK |
|||
General specifications |
Applicable servo amplifier |
SV2-010L2 |
||
Rated output |
100 W |
|||
Rated torque |
0.318 N·m *1 |
|||
Instant maximum torque |
1.11 N·m |
|||
Rated current |
0.85 Arms |
|||
Instant maximum current |
3.1 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.413 N·m/Arms |
|||
Rotor moment of inertia |
0.0659 ×10-4kg·m2 |
|||
Rated power rating |
15.3 kW/s |
|||
Rated angle acceleration |
48200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.4 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||