Specifications
Model |
SJ-H300C |
|||
Type |
HC |
|||
Ion generation method |
Corona discharge |
|||
Structure |
Shock-proof, resistance-coupled |
|||
Voltage application method/applied voltage |
Pulse AC method/±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Cleanliness |
ISO 14644-1 Class 2 *2 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or non-voltage contact signal |
|||
Control output |
NPN type photorelay, 100 mA max. (at 40 V max.) |
|||
Major functions |
Condition alarm output, ion level alarm output, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *3 |
|||
Effective length |
3000 mm 118.11" *4 |
|||
No. ofelectrodes |
48 |
|||
Static elimination bar length |
2960 mm 116.54" |
|||
Rating |
Power voltage |
24 VDC-36 V±10% |
||
Current consumption |
500 mA (at 24 VDC)/350 mA (at 36 VDC) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32.0°F to 104.0°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Electrode probe |
Silicon |
||
Main unit |
ABS resin/PC |
|||
Weight |
Static elimination bar |
3150 g 111.11 oz |
||
*1 Value measured under the following conditions: | ||||

Specifications
Model |
SJ-HW01 |
|||
Type |
Wide angle booster starter unit |
|||

Specifications
Model |
SJ-HW02 |
|||
Type |
Extension unit for wide angle booster |
|||

Specifications
Model |
SJ-L005F |
|||
Voltage application method |
High frequency AC method |
|||
Applied voltage |
3 kVAC |
|||
Ion balance |
±10 V *1 |
|||
Installation distance |
50 mm 1.97 " or greater |
|||
Maximum air speed |
7 m/s *1 |
|||
Maximum air flow |
0.16 m3/min |
|||
Ozone concentration |
0.05 ppm or less *1 |
|||
Control input |
Static elimination stop input |
Can switch between “non-voltage input” and “voltage input” *2*3 |
||
Control output |
Alarm (N.C.) /Ion level alarm (N.O.) |
Open collector output: 30 V DC or less |
||
Power supply |
Power voltage |
24 V DC ±10 % (including ripple) or 12 V DC |
||
Power consumption |
310 mA or less (for 24 V DC) |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to +122 °F |
||
Relative humidity |
35 to 65 % RH (assuming no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Weight |
Approx. 100 g (main unit weight) |
|||
*1 Measurement results taken with an installation distance of 100 mm 3.94 " , maximum air flow and no air filter. (Representative values) | ||||

Specifications
Model |
SJ-L005G |
|||
Voltage application method |
High frequency AC method |
|||
Applied voltage |
3.2 kVAC |
|||
Ion balance |
±10 V*1 |
|||
Static elimination time |
0.4 sec.*1 |
|||
Operating distance |
50 mm 1.97" or more |
|||
Air supply pressure |
0.05 to 0.7 Mpa |
|||
Air supply temperature |
0 to +50°C 32 to 122°F |
|||
Connection tube |
Outer diameter: ø8 0.31", inner diameter: ø6 0.24" |
|||
Ozone concentration |
0.05 ppm or less*2 |
|||
Ratings |
Power voltage |
12 VDC (dedicated AC adapter OP-88020/87722 *3) |
||
Current consumption |
0.3 A max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used) |
||
Relative humidity |
35 to 65% RH (no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Drop resistance |
Onto concrete from a height of 2.0 m 6.6'*4 |
|||
Material |
Main unit case: PC / Status indicator: TPU / Cable: PVC, copper alloy |
|||
Weight |
Approx. 320 g |
|||
*1 Measurement results taken with an installation distance of 150 mm 5.91" and air supply pressure of 0.2 MPa (typical values) | ||||

Specifications
Model |
SJ-L005M |
|||
Type |
Nozzle type |
|||
Voltage application method |
High frequency AC method |
|||
Applied voltage |
2.2 kVAC |
|||
Ion balance |
±10 V*1 |
|||
Static elimination time |
0.4 sec.*1 |
|||
Air supply pressure |
0.05 to 0.5 MPa |
|||
Air supply temperature |
0 to +50°C 32 to 122°F |
|||
Connection tube |
Outer diameter: ø6 0.24", inner diameter: ø4 0.16" |
|||
Ozone concentration |
0.05 ppm or less*2 |
|||
Control input |
Static elimination stop input |
Switchable between non-voltage input and voltage input |
||
Reset input | ||||
LPC mode input | ||||
Control output |
Alarm (N.C.)/Ion level alarm (N.O.) |
Open-collector output 30 VDC or less |
||
Ratings |
Power voltage |
24 VDC ±10% (including ripple) or |
||
Current consumption |
0.2 A or less (24 VDC) |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used) |
||
Relative humidity |
35 to 65% RH (no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Material |
Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT |
|||
Weight |
Approx. 60 g |
|||
*1 Measurement results taken with an installation distance of 150 mm 5.91", air supply pressure of 0.2 MPa, and a nozzle angle of 90° (typical values) | ||||

Specifications
Model |
SJ-L005MT |
|||
Type |
Tube type |
|||
Voltage application method |
High frequency AC method (68 kHz) |
|||
Applied voltage |
2.5 kVAC |
|||
Ion balance |
±10 V*1 |
|||
Static elimination time |
See Data Sheet. |
|||
Air supply pressure |
0.05 to 0.5 MPa |
|||
Air supply temperature |
0 to +50°C 32 to 122°F |
|||
Connection tube |
Outer diameter: ø6 0.24", inner diameter: ø4 0.16" |
|||
Ozone concentration |
0.05 ppm or less*2 |
|||
Control input |
Static elimination stop input |
Switchable between non-voltage input and voltage input |
||
Reset input | ||||
LPC mode input | ||||
Control output |
Alarm (N.C.)/Ion level alarm (N.O.) |
Open-collector output 30 VDC or less |
||
Ratings |
Power voltage |
24 VDC ±10% (including ripple) or |
||
Current consumption |
0.2 A or less (24 VDC) |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used) |
||
Relative humidity |
35 to 65% RH (no condensation) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Material |
Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT |
|||
Weight |
Approx. 65 g |
|||
*1 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 50 mm 1.97", and air supply pressure of 0.2 MPa (typical values) | ||||




Specifications
Model |
SJ-M020 |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec. max.*1 |
|||
Ion balance |
±15 V*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +80°C 32 to +176°F*4*5 |
||
Relative humidity |
35 to 65%RH (no condensation)*3 |
|||
Weight |
Approx. 600 g |
|||
*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min, | ||||

Specifications
Model |
SJ-M020G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec. max.*1 |
|||
Ion balance |
±15 V*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +80°C 32 to +176°F*4*5 |
||
Relative humidity |
35 to 65%RH (no condensation)*3 |
|||
Weight |
Approx. 600 g |
|||
*1 Operating distance: 50 mm 1.97", Air volume: 60 NL/min, | ||||

Specifications
Model |
SJ-M021 |
|||
Type |
Static Elimination Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec max.*1 |
|||
Ion balance |
±15 V or less*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Min. air pressure |
With SJ-ML |
0.02 MPa (20 Nl/min) |
||
With SJ-MS/ML1 |
0.03 MPa (20 Nl/min) |
|||
With SJ-MS/ML2 |
0.02 MPa (20 Nl/min) |
|||
With SJ-MS/ML3 |
0.08 MPa (50 Nl/min) |
|||
With SJ-MS/ML4 | ||||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +80 °C 32 to 176 °F*4*5 |
||
Relative humidity |
35 to 65 % RH |
|||
Weight |
Approx. 600 g |
|||
*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %) | ||||

Specifications
Model |
SJ-M021G |
|||
Type |
Static Elimination Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec max.*1 |
|||
Ion balance |
±15 V or less*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Min. air pressure |
With SJ-ML |
0.02 MPa (20 Nl/min) |
||
With SJ-MS/ML1 |
0.03 MPa (20 Nl/min) |
|||
With SJ-MS/ML2 |
0.02 MPa (20 Nl/min) |
|||
With SJ-MS/ML3 |
0.08 MPa (50 Nl/min) |
|||
With SJ-MS/ML4 | ||||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +80 °C 32 to 176 °F*4*5 |
||
Relative humidity |
35 to 65 % RH |
|||
Weight |
Approx. 600 g |
|||
*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %) | ||||

Specifications
Model |
SJ-M030 |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa or less |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
164 mm 6.457" |
|||
Total length |
220 mm 8.661" |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Please make an inquiry as to the measurement condition. | ||||

Specifications
Model |
SJ-M030C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
164 mm 6.46"*2 |
|||
Total length |
220 mm 8.66"*3 |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Measured under the following conditions: | ||||

Specifications
Model |
SJ-M030G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa max. |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open-collector, 100 mA max. (40 V max.) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
164 mm 6.46"*2 |
|||
Total length |
220 mm 8.66"*3 |
|||
Rating |
Power voltage |
24 VDC ±10% |
||
Current consumption |
450 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to +104°F |
||
Relative humidity |
35 to 65%RH (no condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Measured under the following conditions: | ||||

Specifications
Model |
SJ-M031C |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
164 mm 6.457"*2 |
|||
Total length |
220 mm 8.66"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge: None | ||||

Specifications
Model |
SJ-M031G |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Air purge supplied pressure |
0.2 MPa or less |
|||
Effective length |
164 mm 6.457"*2 |
|||
Total length |
220 mm 8.66"*3 |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Operating distance: 50 mm 1.96" (50 Hz), 600 mm 23.62" (8 Hz), 1,500 mm 59.05" (1 Hz). Downward air flow: 0.3 m/s. Air purge (3 NL/min) /1electrode | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-M070 |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa or less |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
324 mm12.756" |
|||
Total length |
380 mm14.961" |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Please make an inquiry as to the measurement condition. | ||||