Sensors
1788 products
Showing 49 - 72 of 1788 products

Specifications
Model |
GT2-71CP |
|||
Mounting method |
DIN-rail mount |
|||
Output |
PNP output |
|||
Main unit/expansion unit |
Main unit |
|||
Power supply voltage |
10 to 30 VDC, including 10 % ripple (P-P), Class 2*1 |
|||
Power consumption |
Normal |
2,200 mW max. (30 V, 73.3 mA max.) |
||
Power saving (Eco) |
1,700 mW max. (30 V, 56.7 mA max.) |
|||
Display power |
Measured value display |
6 + 1/2-digit 7-segment LED (red) |
||
Other displays |
2-color, 13-level bar LED display (red, green), indicators (red, green) |
|||
Display range |
-199.999.9 to 199.999.9 |
|||
Display resolution |
0.1 μm 0.004 Mil |
|||
Control input |
Timing/preset/ |
No-voltage input |
||
Control output |
HH/HI/GO/LO/LL |
PNP open collector, 30 V 50 mA or less, residual voltage 1 V or less*1*2 |
||
Analog output |
- |
|||
Response time |
hsp(3)/5/10/100/500/1,000 ms |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC |
|||
Weight |
Approx. 70 g |
|||
*1 When adding expansion units, there are the following restrictions according to the number of connected units. | ||||
Scroll

Specifications
Model |
GT2-100P |
|||
Mounting method |
Panel mount/Screw mounting using optional mounting bracket |
|||
Output |
PNP output |
|||
Main unit/expansion unit |
- |
|||
Power supply voltage |
20 to 30 VDC, including 10 % ripple (P-P), Class 2 |
|||
Power consumption |
Normal |
4,500 mW max. (30 V, 150 mA max.) |
||
Power saving (Eco) |
3,600 mW max. (30 V, 120 mA max.)*1 |
|||
Display power |
Measured value display |
6 + 1/2-digit 7-segment LED (red) |
||
Other displays |
2-color, 13-level bar LED display (red, green), indicators (red, green) |
|||
Display range |
-199.999.9 to 199.999.9 |
|||
Display resolution |
0.1 μm 0.004 Mil |
|||
Control input |
Timing/preset/ |
No-voltage input |
||
Control output |
HH/HI/GO/LO/LL |
PNP open collector, 30 V 50 mA or less*2, residual voltage 1 V or less |
||
Response time |
hsp(3)/5/10/100/500/1,000 ms |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.15 mm 0.006", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET |
|||
Power supply/I/O cable |
Power supply: Terminal block, I/O: 20-pin connector (MIL standard) |
|||
Weight |
Approx. 380 g |
|||
*1 For GT2-100 Series, when the maximum number of sensor heads are connected and all units are set to power saving mode. | ||||
Scroll

Specifications
Model |
FU-10 |
|||
Type |
Variable spot |
|||
Focal distance |
10 to 30 mm0.394" to 1.181" |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.3×2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
Scroll

Specifications
Model |
FS-N41P |
|||
Type |
Cable |
|||
Output |
PNP |
|||
Main unit/expansion unit |
Main unit |
|||
Response time |
23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
1 |
|||
Number of external inputs |
― |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
Control output |
Open-collector, 30 V or less 100 mA or less per output, |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*3 |
|||
Unit expansion |
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4 |
||
Power consumption |
During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*6 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 78 g |
|||
*1 Restrictions when S-HSPD is selected | ||||
Scroll

Specifications
Model |
FS-N41N |
|||
Type |
Cable |
|||
Output |
NPN |
|||
Main unit/expansion unit |
Main unit |
|||
Response time |
23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA) |
|||
Number of control outputs |
1 |
|||
Number of external inputs |
― |
|||
Light source LED |
Transmitter side: Red, four-element LED (wavelength: 660 nm) |
|||
Control output |
Open-collector, 30 V or less 100 mA or less per output, |
|||
External input |
Input time: 2 ms (ON) /20 ms (OFF) or longer*3 |
|||
Unit expansion |
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units. |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
Mutual interference prevention |
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.) |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4 |
||
Power consumption |
During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V) |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less |
||
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing)*6 |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 78 g |
|||
*1 Restrictions when S-HSPD is selected | ||||
Scroll

Specifications
Model |
GT2-S5*1 |
|||
Detection system |
Differential transformer |
|||
Measuring range |
5 mm 0.20"*2 |
|||
Operating range |
7 mm 0.28"*2 |
|||
Resolution |
0.1 µm |
|||
Indicated accuracy |
1 µm (P-P)*3*4 |
|||
Measuring force |
Downward mounting |
1.0 N*5 |
||
Side mounting |
0.95 N*5 |
|||
Upward mounting |
0.9 N*5 |
|||
Sampling cycle |
1 ms |
|||
Mechanical response |
20 Hz*4 |
|||
Operation indicator light |
2-color LED (red, green) |
|||
Environmental resistance |
Enclosure rating |
IP67G (JIS)*6, IP67 (IEC) |
||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
10 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2 (IEC60068-2-27) |
|||
Materials |
Main body |
Main body case: SUS430F, Sensor head-relay connector cable: PUR, Relay amplifier: PPSU |
||
Dust boot |
NBR |
|||
Contact |
SUS304, cemented tungsten carbide*7 |
|||
Sensor head cable |
Optional (connect to relay connector) |
|||
Weight |
Approx. 40 g (not including cable)*8 |
|||
*1 Note: You may not be able to connect the sensor head to the amplifier unit depending on when the amplifier unit was purchased. For details, contact your local sales office. | ||||
Scroll

Specifications
Model |
CZ-H52 |
|||
Type |
Fluorescence detection UV |
|||
Detecting area |
25 to 55 mm 0.98" to 2.17" |
|||
Smallest spot diameter |
Approx. 10 mm 0.39 dia. at reference distance of 25 mm 0.98"" |
|||
Light source |
UV (ultraviolet) LED (375 nm) *1 |
|||
Minimum bend radius of fi ber |
― |
|||
Receivable wavelength (Receiver) |
425 to 550 nm |
|||
Environmental resistance |
Enclosure rating |
IP40 |
||
Ambient light |
Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max. |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing:Fiberglass reinforced plastic , Lens cover:Glass |
|||
Weight |
Approx. 40 g |
|||
*1 The CZ-H52 emits ultraviolet light from the transmitter. Do not directly look at the light | ||||
Scroll

Specifications
Model |
OP-87057 |
|||
Type |
Sensor head cable |
|||
Applicable product |
IL,IG,GV-T Series head |
|||
Cable end |
M8 straight - e-con |
|||
Length |
5 m 16.40' |
|||
Material |
Cable: Polyvinyl chloride (PVC) |
|||
Note |
The cable is common to the transmitter and receiver sides, and can be used on either of them. |
|||
Weight |
Approx. 190 g |
|||
Scroll

Specifications
Model |
IL-600 |
|||
Reference distance |
600 mm 23.62" |
|||
Measurement range |
200 to 1000 mm 7.87" to 39.37" |
|||
Light source |
Type |
Red semiconductor laser, wavelength: 655 nm (visible light) |
||
Laser class |
Class 2 (FDA (CDRH) Part1040.10)*1 |
|||
Output |
560 µW |
|||
Spot diameter (at standard distance) |
Approx. ø1.6 mm ø0.06" |
|||
Linearity |
±0.25% of F.S. (200 to 600 mm 7.84" to 23.62")*2*3 |
|||
Repeatability |
50 µm*4 |
|||
Sampling rate |
0.33/1/2/5 ms (4 levels available) |
|||
Operation status indicators |
Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED |
|||
Temperature characteristics |
0.08% of F.S./°C*5 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pollution degree |
3 |
|||
Ambient light |
Incandescent lamp: 5,000 lux*6 |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No condensation or freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 135 g |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice. | ||||
Scroll

Specifications
Model |
IL-2000*1 |
|||
Reference distance |
2000 mm 78.74" |
|||
Measurement range |
1000 to 3500 mm 39.37" to 137.80" |
|||
Light source |
Type |
Red semiconductor laser, wavelength: 655 nm (visible light) |
||
Laser class |
Class 2 (FDA (CDRH) Part1040.10)*2 |
|||
Output |
560 µW |
|||
Spot diameter (at standard distance) |
Approx. 1400 × 7000 µm |
|||
Linearity |
±0.16% of F.S. (1000 to 3500 mm 39.37" to 137.80")*3*4 |
|||
Repeatability |
100 µm*5 |
|||
Sampling rate |
0.33/1/2/5 ms (4 levels available) |
|||
Operation status indicators |
Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED |
|||
Temperature characteristics |
0.016% of F.S./°C*6 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pollution degree |
3 |
|||
Ambient light |
Incandescent lamp: 10,000 lux*7 |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No condensation or freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 350 g |
|||
*1 Amplifiers purchased before August 8th, 2012 cannot be used. | ||||
Scroll

Specifications
Model |
IL-030 |
|||
Reference distance |
30 mm 1.18" |
|||
Measurement range |
20 to 45 mm 0.79" to 1.77" |
|||
Light source |
Type |
Red semiconductor laser, wavelength: 655 nm (visible light) |
||
Laser class |
Class 1 (FDA (CDRH) Part1040.10)*1 |
|||
Output |
220 µW |
|||
Spot diameter (at standard distance) |
Approx. 200 × 750 µm |
|||
Linearity |
±0.1% of F.S. (25 to 35 mm 0.98" to 1.38")*2*3 |
|||
Repeatability |
1 µm*4 |
|||
Sampling rate |
0.33/1/2/5 ms (4 levels available) |
|||
Operation status indicators |
Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED |
|||
Temperature characteristics |
0.05% of F.S./°C*5 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Pollution degree |
3 |
|||
Ambient light |
Incandescent lamp: 5,000 lux*6 |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No condensation or freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 60 g |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice. | ||||
Scroll

Specifications
Model |
OP-87443 |
|||
Type |
Monitor power cable |
|||
Cable end |
M8 4-pin / Strand wire |
|||
Length |
2 m 6.6' |
|||
Scroll

Specifications
Model |
LV-H62 |
|||
Type |
Small beam spot |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
2 m 6.6' |
||
TURBO |
5 m 16.4' |
|||
SUPER |
7 m 23.0' |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Transparent plastic *1 |
|||
Reflective mirror |
Polycarbonate, acrylic |
|||
Weight |
Approx. 45 g |
|||
*1 Norbornene plastic or acrylic | ||||
Scroll

Specifications
Model |
PZ-G62CB |
|||
Type |
Retro-reflective, Transparent object detection*1 |
|||
Shape |
Threaded |
|||
Output |
Bipolar |
|||
Cable connection |
M12 connector *2 |
|||
Detecting distance |
0.1 to 1 m |
|||
Spot diameter |
― |
|||
Light source |
Infrared LED |
|||
Sensitivity adjustment |
1-turn trimmer (230°) |
|||
Response time |
500 µs |
|||
Operation mode |
LIGHT-ON/DARK-ON (switch-selectable) |
|||
Indicators (LED) |
Output: Orange LED, |
|||
Control output |
Open collector output, 30 V max., 100 mA max., Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, overcurrent protection, surge absorber |
|||
Interference suppression |
Up to 2 units |
|||
Tightening torque |
Threaded models (front M18 part): 1.0 N m max., (side slotted hole part): 0.5 N m max. |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 % |
||
Current consumption |
34 mA or less |
|||
Environmental resistance |
Enclosure rating |
IEC: IP67/NEMA: 4A, 6, 12/DIN: IP69K |
||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Housing, M18 nut |
Glass-fiber reinforced PBT |
||
Lens cover |
Polyarylate (PAR) |
|||
Trimmer |
Glass-fiber reinforced polyamide (PA) |
|||
Case connection |
Screw: Nickel-plated iron and zinc, packing: nitrile butadiene rubber (NBR) |
|||
Cable (cable models only) |
Polyvinyl chloride (PVC) |
|||
Connector (connector type with cable only) |
― |
|||
Accessories |
Instruction manual, M18 nut x 1 piece (threaded models only) |
|||
Weight |
Threaded connector models: Approx. 15 g |
|||
*1 Cable sold separately for connector models/pigtail quick disconnect models. Reflector sold separately for retro-reflective models. | ||||
Scroll

Specifications
Model |
LR-TB5000 |
|||
Type |
Cable |
|||
Detectable distance |
60 to 5000 mm 2.36" to 196.85"*1 |
|||
Spot diameter |
Variable |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 2 laser product |
|||
Mutual interference prevention function |
4 units (when using the interference prevention function) |
|||
Timer |
OFF/OFF delay/ON delay/One-shot |
|||
Response time |
1 ms/10 ms/25 ms/100 ms/1000 ms |
|||
I/O |
Control output |
NPN open collector/PNP open collector selectable |
||
Analog output |
Current output/Voltage output selectable |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge |
|||
Power voltage |
20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
|||
Current consumption |
50 mA or less (without load)*5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp/Sunlight: 10,0000 lux or less |
|||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: Zinc die cast (Nickel chrome plating), |
|||
Accompanying items |
Instruction manual, |
|||
Weight |
Approx. 200 g (Including cable) |
|||
*1 The range for displayable distance is from 50 to 5200. | ||||
Scroll

Specifications
Model |
OP-73864 |
|||
Type |
Connector Cable |
|||
Applicable product |
FS-N1*C, FS-V30C, PZ-G, M8 connector sensor |
|||
Number included |
1 pcs. |
|||
Cable end |
M8 straight - Loose wire |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: Polyvinyl chloride (PVC) |
|||
Weight |
Approx. 55 g |
|||
Scroll

Specifications
Model |
LR-ZH500P*1 |
|||
Type |
U.C.D. Function |
|||
Appearance |
Rectangular |
|||
Output |
PNP |
|||
Cable connection |
2 m cable |
|||
Detectable distance |
35 to 500 mm 1.38" to 19.69"(465 to 0)*2 |
|||
Standard detectable deviation |
35 to 180 mm 1.38" to 7.09": 9 mm 0.35" |
|||
Display resolution |
1 to 5 (1 to 5 mm 0.04" to 0.20") |
|||
Spot size |
Approx. ø3 mm ø0.12" |
|||
Response time |
1.5 ms / 10 ms / 50 ms selectable |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 2 laser product (IEC60825-1) |
|||
Function |
Indicator |
3-digit 7-segment display (white), |
||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Specifications |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Power consumption |
450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |
|||
Control output |
PNP Open collector, |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
|||
Output operation |
Light-ON / Dark-ON selectable |
|||
External input |
Input time calibration: 35 ms or more ON, 35 ms or more OFF |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |
||
Insulation resistance |
20 MΩ or more (500 VDC) |
|||
Ambient light |
Incandescent lamp: 10,000 lux or less |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F (No freezing) |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, |
|||
Accompanying items |
Instruction Manual, |
|||
Weight |
Approx. 110 g (Including cable) |
|||
*1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office. | ||||
Scroll

Specifications
Model |
LR-ZB100CN |
|||
Type |
Distance based laser sensor |
|||
Appearance |
Rectangular |
|||
Output |
NPN |
|||
Cable connection |
M8 connector, 4-pin |
|||
Detectable distance |
35 to 100 mm 1.38" to 3.94" (650 to 0)*1 |
|||
Standard detectable deviation |
35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06" |
|||
Display resolution |
2 (0.2 mm 0.008") |
|||
Spot size |
Approx. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94" |
|||
Response time |
1.5 ms / 10 ms / 50 ms selectable |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 1 laser product |
|||
Function |
Indicator |
3-digit 7-segment display (red), |
||
Timer |
OFF/ON delay/OFF delay/One-shot |
|||
Specifications |
Power voltage |
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
||
Power consumption |
450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) |
|||
Control output |
NPN Open collector, |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, reverse output connection |
|||
Output operation |
Light-ON / Dark-ON selectable |
|||
External input |
Input time calibration: 35 ms or more ON, 35 ms or more OFF |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3 |
||
Insulation resistance |
20 MΩ or more (500 VDC) |
|||
Ambient light |
Incandescent lamp: 4,000 lux or less |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F (No freezing) |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating, |
|||
Accompanying items |
Instruction Manual, |
|||
Weight |
Approx. 55 g |
|||
*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed. | ||||
Scroll

Specifications
Model |
LR-XN11P |
|||
Type |
PNP Output |
|||
Cable/Connector |
Cable |
|||
Main Unit/Expansion Unit |
Main Unit |
|||
No. of Control Outputs |
2 |
|||
No. of External Inputs |
1 |
|||
Response Time |
500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable |
|||
IO-Link |
— |
|||
Functions |
Timer Function |
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot |
||
I/O |
Control Output |
Open collector, 30 VDC or lower, N.O./N.C. |
||
External Input |
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable |
|||
Unit Expansion |
Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series. |
|||
Protection Circuit |
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection |
|||
Number of Interference Prevention Devices |
OFF/4 units/8 units selectable*2 |
|||
Power supply |
Power voltage |
16 to 30 VDC*3 (including 10% ripple (P-P) or less), class 2 |
||
Power consumption |
During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
−20 to +55°C -4°F to 131°F (no freezing)*4 |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 (50G); 3 times each for X, Y, and Z axes |
|||
Case Material |
Main Unit and Cover: Polycarbonate |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 80 g |
|||
*1 If 500 µs is selected, the following limitations apply. | ||||
Scroll

Specifications
Model |
NU-EN8N |
|||
I/O |
Connector |
e-CON connector (4-pin) |
||
Inputs |
8 |
|||
Supply voltage for equipment |
Supplied via the NU-EN8N from the connected communication unit |
|||
Supply current |
520 mA or less (total for eight ports) |
|||
Input signal |
NPN open collector output, contact output |
|||
Input response time |
20 µs or less |
|||
Internal input voltage |
8 VDC (Reference value of input current: 3.1 mA) |
|||
Minimum ON voltage |
6 V |
|||
Maximum OFF current |
0.9 mA |
|||
Input resistance |
2.4 kΩ |
|||
Connectable communication units |
CC-Link compatible communication unit NU-CL1, DeviceNet® compatible communication unit NU-DN1, EtherCAT® compatible communication unit NU-EC1A, EtherCAT® compatible communication unit NU-EC1, EtherNet/IP™ compatible communication unit NU-EP1 |
|||
Number of connectable sensors |
2 units max. (occupied ID numbers: 8) *1 |
|||
Sensor connection |
Number of connectable units |
|||
Power voltage |
12 to 24 VDC ±10%; ripple (P-P) 10% or less *2 |
|||
Accessories |
Instruction manual, Tag, Index seal |
|||
Weight |
Approx. 55 g (including tag) |
|||
*1 The NU-EN8N occupies eight ID numbers of the communication unit regardless of the number of input devices connected. | ||||
Scroll

Specifications
Model |
NU-PN1 |
|||
Name |
PROFINET Compatible Network Unit |
|||
Compatible network |
PROFINET I/O communication |
|||
Ethernet |
Compliant standards |
IEEE802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps (100BASE-TX) |
|||
Transmission media |
STP cable or Category 5 or higher UTP cable |
|||
Maximum cable length |
100 m |
|||
Max. number of connection stages |
2 |
|||
PROFINET |
Compatible functions |
Cyclic communication (Data I/O communication) |
||
Number of connectable controllers |
1 |
|||
Update Time |
2 to 512 ms |
|||
Version of GSDML |
Version 2.3 |
|||
Conformance class |
Complies with conformance class A |
|||
Conformance test version |
Complies with version 2.2.4 |
|||
Applicable protocols |
LLDP, DCP |
|||
Sensor connection |
Connectable sensors |
Sensors with N-bus support *1 |
||
Number of connectable units |
16 units max. |
|||
Power supply |
Power received from the NU-PN1 via the sensor connector |
|||
Allowable passing current |
Overall 1200 mA or less *2 |
|||
Power during PoE power receiving |
Supply voltage: 24V±10%, supply current: 360 mA or less *3*4 |
|||
Power voltage |
24 VDC ±10%, ripple (p-p) 10% or less (with power supply connector) |
|||
Power consumption |
1500 mW or less (at 24 V 60 mA max) *5 |
|||
Environmental resistance |
Pollution degree |
2 |
||
Ambient temperature |
-20 to 55°C (no freezing) |
|||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 55 Hz compound amplitude 1.5 mm, 2 hours each in X, Y, Z directions |
|||
Material |
Main unit case: Polycarbonate |
|||
Weight |
Approx. 80 g |
|||
*1 "N-bus" is the name of KEYENCE's wiring-saving system for sensors. | ||||
Scroll

Specifications
Model |
NU-EP1 |
|||
Name |
Communication unit that supports EtherNet/IP™ |
|||
Ethernet |
Compliant standards |
IEEE802.3 (10BASE-T), IEEE802.3u (100BASE-TX), IEEE802.3af (Power over Ethernet, Class 3) |
||
Transmission rate |
10 Mbps (10BASE-T), 100 Mbps (100BASE-TX) |
|||
Transmission media |
STP or category 3 or higher UTP (10BASE-T),*1 STP or category 5 or higher UTP (100BASE-TX) |
|||
Maximum cable length |
100 m 328.1' (the length between this unit and the Ethernet switch) |
|||
Max. number of connection stages |
4 (10BASE-T) 2 (100BASE-TX)*2 |
|||
EtherNet/IP™ |
Compliant functions |
Cyclic communication (implicit messages), message communication (explicit messages) |
||
Number of connections |
64 |
|||
RPI (Transmission cycle) |
0.5 to 10,000 ms (in units of 0.5 ms) |
|||
Tolerable communication bandwidth for cyclic communication |
6,000 pps |
|||
Message communication |
Supports UCMM, Class 3 |
|||
Conformance test |
Supports version A7 |
|||
Sensor connection |
Connectable sensors |
Sensor amplifier that supports N-bus*3 |
||
Number of connectable units |
16 maximum*4 |
|||
Power supply |
Power is supplied by this unit through the sensor amplifier connection connector. |
|||
Allowable passing current |
Total: 1,200 mA or less*5 |
|||
Power during PoE power receiving |
Supply voltage: 24 V ±10 %, supply current: 360 mA or less*6 (UL Class 2)*7 |
|||
Indicator lamp |
Link/activity indicator (LINK/ACT): green LED, module status indicator (MS): 2-color (green and red) LED, network status indicator (NS): 2-color (green and red) LED, sensor communication indicator (N-bus): 2-color (green and red) LED |
|||
Power voltage |
24 VDC ±10 %, ripple (P-P): 10 % or less (when using the power supply connector); 48 VDC (57 V maximum; during PoE power receiving) |
|||
Power consumption |
1,500 mW or less (60 mA or less at 24 V)*8 |
|||
Environmental resistance |
Pollution degree |
2 |
||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit case and dust cover: polycarbonate, power supply connector: polyamide (plug), PBT (socket) |
|||
Accessories |
Instruction manual, power supply connection connector, end unit x 2 |
|||
Weight |
Approx. 80 g (including connectors) |
|||
*1 When using the PoE power receiving function to form a connection, use an STP cable or category 5 or higher UTP cable. | ||||
Scroll

Specifications
Model |
NU-EC1 |
|||
Name |
Communication unit that supports EtherCAT |
|||
Ethernet |
Compliant standards |
IEEE802.3u (100BASE-TX) |
||
Transmission rate |
100Mbps (100BASE-TX) |
|||
Transmission media |
Category 5e STP |
|||
Distance between nodes |
100 m 328.1' |
|||
Communication ports |
RJ-45x2 |
|||
EtherCAT |
Compatible functions |
Process data object communication (cyclic communication), |
||
Sensor connection |
Connectable sensors |
Sensor amplifier that supports N-bus*1 |
||
Number of connectable units |
16 maximum*2 |
|||
Power supply |
Power is supplied by this product through the wiring-saving connector. |
|||
Allowable passing current |
Total: 1,200 mA or less*3 |
|||
Indicator lamp |
Power indicator (PWR): green LED, |
|||
Power voltage |
24 VDC ± 10%, ripple (P-P) 10% or less |
|||
Power consumption |
1,700 mW or less (70 mA or less at 24 V)*4 |
|||
Environmental resistance |
Pollution degree |
2 |
||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit case and dust cover: polycarbonate, |
|||
Accessories |
Instruction manual, power supply connection connector, end unit × 2 |
|||
Weight |
Approx. 80 g (including connectors) |
|||
*1 "N-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers. | ||||
Scroll

Specifications
Model |
NU-DN1 |
|||
Number of connectable sensors |
16 units max. *1 |
|||
Sensor connection |
Connectable sensors |
Sensor amplifier that supports N-bus*2 |
||
Number of connectable units |
16 maximum*3 |
|||
Allowable passing current |
Total: 1,200 mA or less*4 |
|||
DeviceNet® specifi cations |
Compliant functions |
I/O Message (polling), Explicit Message |
||
Address setting |
0 to 63 (PGM compatible) |
|||
Baud rate (automatically switched) |
500 kbps, 250 kbps, 125 kbps |
|||
Maximum cable length |
500 kbps |
thick cable |
100 m 32.81' |
|
thin cable | ||||
250 kbps |
thick cable |
250 m 820.21' |
||
thin cable |
100 m 32.81' |
|||
125 kbps |
thick cable |
500 m 1640.42' |
||
thin cable |
100 m 32.81' |
|||
Power voltage |
11 to 25 VDC *5 |
|||
Power consumption |
1480 mW or less (at 24 V, 60 mA max.) *6 |
|||
Accessories |
Instruction manual, DeviceNet® connector, End unit |
|||
Weight |
Approx. 65 g (including connectors) |
|||
*1 Depends on the sensor amplifi ers connected. | ||||
Scroll