Filters

Sensors

1788 products

Showing 1 - 24 of 1788 products

Showing 1 - 24 of 1788 products
View
Keyence New Stock Image
Keyence LR-TB5000C Keyence
Sale price 5,094.00 kr
Only 9 units left

Specifications

Model

LR-TB5000C

Type

Cable with connector M12

Detectable distance

60 to 5000 mm 2.36" to 196.85"*1

Spot diameter

Variable
(use a spot diameter of 40 mm 1.57" or less)

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product
(IEC60825-1,FDA (CDRH) Part1040.10*2)

Mutual interference prevention function

4 units (when using the interference prevention function)

Timer

OFF/OFF delay/ON delay/One-shot

Response time

1 ms/10 ms/25 ms/100 ms/1000 ms
selectable

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, residual voltage: 2 V or less,
N.O./N.C. selectable
*3*4

Analog output

Current output/Voltage output selectable
Current output: 4 to 20 mA with a max. load resistance of 500 Ω
Voltage output: 0 to 10 V with an external load resistance of 5 kΩ or more
*3*4

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge

Power voltage

20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

50 mA or less (without load)*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp/Sunlight: 10,0000 lux or less

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover and buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating specifications),
Cable bushing: PBT,
Cable: PVC,
M12 connector: TPE, PBT, Nickel-plated brass

Accompanying items

Instruction manual,
Laser warning and explanation labels

Weight

Approx. 160 g

*1 The range for displayable distance is from 50 to 5200.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 You can select the I/O from the following combinations.
Control output × 2, control output + external input
Control output + analog output (LR-TB5000/TB5000C/TB5000CL only)
External input + analog output (LR-TB5000/TB5000C/TB5000CL only)
(For details on the setting method, see the instruction manual.)
*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*5 150 mA or less(with load)

Keyence New Stock Image
Keyence LV-NH110 Keyence
Sale price 3,695.00 kr
Only 10 units left

Specifications

Model

LV-NH110

Type

Area thrubeam, High power

FDA (CDRH) Part 1040.10

Class 1 Laser Product

IEC 60825-1

Light source

Visible red semiconductor laser, Wavelength: 660 nm

Detecting
distance

MEGA

2000 mm 78.74"
(Detecting area: 10 mm 0.39")

ULTRA

SUPER

TURBO

FINE

HSP

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Case

Glass reinforced plastic

Lens cover

Transmitter: Glass, Receiver: Polyarylate

Weight

Approx. 75 g

Keyence New Stock Image
Keyence GT2-P12K Keyence
Sale price 7,891.00 kr
In stock, 16 units

Specifications

Model

GT2-P12K*1

Detection system

Scale Shot System II, absolute (no tracking errors) type

Measuring range

12 mm 0.47"

Resolution

0.1 μm 0.004 Mil

Indicated accuracy

1 µm 0.04 Mil (p-p)*2

Measuring force

Downward mounting

1.0 N*3

Side mounting

0.95 N*3

Upward mounting

0.9 N*3

Sampling cycle

4 ms

Mechanical response

10 Hz*2

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67G (JIS)*4, IP67 (IEC), NEMA Type 13*4

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body case: SUS 303, Status indicator: PET, Sensor head-relay connector cable: PUR, Relay connector: PBT

Dust boot

NBR

Contact

SUS304, cemented tungsten carbide*5

Sensor head cable

Optional (connect to relay connector)

Weight

Approx. 35 g (excluding cable)*6

*1 Note: You may not be able to connect the sensor head to the amplifier unit depending on when the amplifier unit was purchased. For details, contact your local sales office.
*2 Value when the ambient temperature is 20 °C 68 °F.
*3 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*4 When an M8 oil-resistant cable (GT2-CHP2M/CHP5M/CHP10M) is used for the sensor head cable.
*5 The contact is included with the sensor.
*6 Including the relay connector.

Keyence New Stock Image
Keyence LR-TB2000C Keyence
Sale price 3,803.00 kr
In stock, 14 units

Specifications

Model

LR-TB2000C

Type

Cable with connector M12

Detectable distance

60 to 2000 mm 2.36" to 78.74"*1

Spot diameter

Approx. ø4 mm ø0.16"

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product
(IEC60825-1,FDA (CDRH) Part1040.10*2)

Mutual interference prevention function

4 units (when using the interference prevention function)

Timer

OFF/OFF delay/ON delay/One-shot

Response time

1 ms/10 ms/25 ms/100 ms/1000 ms
selectable

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, residual voltage: 2 V or less,
N.O./N.C. selectable
*3*4

Analog output

-

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge

Power voltage

20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

45 mA or less (without load)*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp/Sunlight: 10,0000 lux or less

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover and buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating specifications),
Cable bushing: PBT,
Cable: PVC,
M12 connector: TPE, PBT, Nickel-plated brass

Accompanying items

Instruction manual,
Laser warning and explanation labels

Weight

Approx. 85 g

*1 The range for displayable distance is from 50 to 2200.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 You can select the I/O from the following combinations.
Control output × 2, control output + external input
Control output + analog output (LR-TB5000/TB5000C/TB5000CL only)
External input + analog output (LR-TB5000/TB5000C/TB5000CL only)
(For details on the setting method, see the instruction manual.)
*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*5 145 mA or less (with load)

EH-614A Keyence
Keyence EH-614A Keyence
Sale price 1,441.00 kr
In stock, 44 units

Specifications

Model

EH-614A

Type

Standard , Shielded , ULTRA thin

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target (iron, t=1 mm 0.04")

15 x 15 mm 0.59" x 0.59"

Stable detecting range

0 to 5 mm0.20"

Maximum detecting distance

8 mm0.31"

Hysteresis

0.05 mm0.002"

Repeatability

0.005 mm0.0002"

Temperature characteristics

±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 57 g (including nuts and 3-m 9.8' cable)

Keyence New Stock Image
Keyence LR-W500C Keyence
Sale price 3,803.00 kr
In stock, 11 units

Specifications

Model

LR-W500C

Type

M12 connector 4-pin type

Detecting distance

30 to 500 mm 1.18" to 19.69"

Min. spot diameter

Adjustable spot
Approx. ø3.5 mm at 100 mm ø0.14" at 3.94"
Approx. ø9 mm at 250 mm ø0.35" at 9.84"
Approx. ø18 mm at 500 mm ø0.71" at 19.69"

Light source

White LED

Mutual interference reduction function

Up to 2 units when alternate frequencies set

Timer

OFF/ON delay/OFF delay/One-shot

Response time

200 µs/1 ms/10 ms/100 ms/500 ms selectable *1

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, remaining voltage: 2 V or less
N.O./N.C. selectable
*2

External input

Tuning /Transmission OFF selectable
Short circuit current: 1 mA or less for NPN/2 mA or less for PNP
For the applied voltage, see the wiring diagrams in the instruction manual.
For the input times, see the time charts in the instruction manual.
*2

Protection circuit

Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Power supply

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

65 mA or less (without load) at 24 VDC;
120 mA or less (without load) at 12 VDC *3

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less

Ambient temperature

-20 to +50 °C -4 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover: PPSU, Buttons: PES
Lens cover and display: PMMA (scratch-resistant coating),
Spot adjustment dial: Iron (triiron tetraoxide coated)
Connector ring: PMP, Connector socket: PEI

Weight

Approx. 110 g

*1 When alternate frequencies are set, the response time increases by approximately 20%.
*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*3 195 mA or less (at 10 V, with load)

Keyence New Stock Image
Keyence LR-ZB100CP Keyence
Sale price 3,050.00 kr
Only 6 units left

Specifications

Model

LR-ZB100CP

Type

Distance based laser sensor

Appearance

Rectangular

Output

PNP

Cable connection

M8 connector, 4-pin

Detectable distance

35 to 100 mm 1.38" to 3.94" (650 to 0)*1

Standard detectable deviation

35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06"
50 to 100 mm 1.97" to 3.94": 3 mm 0.12"

Display resolution

2 (0.2 mm 0.008")

Spot size

Approx. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 4,000 lux or less
Sunlight: 8,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 55 g

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

FS-V31P Keyence
Keyence FS-V31P Keyence
Sale price 1,305.00 kr
In stock, 12 units

Specifications

Model

FS-V31P

Type

1-output with cable

Output

PNP

Main unit/Expansion unit

Main unit

Control output

1 output

Monitor output (1 to 5 V)

N/A

External input

Connector

Light source LED

Red, 4-element LED (Wavelength: 640 nm)

Response time

33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO)

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Operation indicator: Red LED/Dual digital monitor: Dual 7-segment display, Preset Value (4-digit green LED indicator) and
Current Value (4-digit red LED indicator) illuminated together. Current Value range: 0 to 64,512; Excess gain: 0P to 999P,
Hold function: Possible to display both peak and bottom hold values, Selectable from 5 variations
Bar LED monitor: Excess gain displayed (85% to 115% in 7 steps), Scaling display

Size

30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D)

Detection mode

Light intensity (area detection possible, automatic sensitivity-tracking function provided)

Timer function

OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable
Timer duration selectable: 0.1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.

Control output

PNP open-collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max.

External inputy

Input time: 2 ms (ON)/20 ms (OFF) min.*2

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units.

Number of interference prevention units

Normal operation

HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Power consumption

Normal: 750 mW max. (Using 24 V, 31 mA max., using 12 V, 40 mA max.)/
Power saving 580 mW max. (Using 24 V, 24 mA max., using 12 V,
28 mA max.)*3

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

N/A

Weight

Approx. 80 g

*1 Total current of two outputs should be less than 100 mA.
*2 Only available on certain models.
*3 When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA).
*4 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
1 to 2 Units: -10 to +55 °C 14 to 131 °F, 3 to 10 Units: -10 to +50 °C 14 to 122 °F, 11 to 16 Units: -10 to +45 °C 14 to 113 °F

Keyence New Stock Image
Keyence LR-ZH490CB Keyence
Sale price 8,321.00 kr
In stock, 12 units

Specifications

Model

LR-ZH490CB*1

Type

U.C.D. Function
Distance based laser sensor

Appearance

M18 Threaded mount

Output

NPN/PNP selectable

Cable connection

M12 connector, 4-pin

Detectable distance

25 to 490 mm 0.98" to 19.29" (465 to 0)*2

Standard detectable deviation

25 to 170 mm 0.98" to 6.69": 9 mm 0.35"
170 to 290 mm 6.69" to 11.42": 25 mm 0.98"
290 to 390 mm 11.42" to 15.35": 40 mm 1.57"
390 to 490 mm 15.35" to 19.29": 50 mm 1.97"

Display resolution

1 to 5 (1 to 5 mm 0.04" to 0.20")

Spot size

Approx. ø3 mm ø0.12"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product (IEC60825-1)
Class II Laser product (FDA(CDRH) Part1040.10)

Function

Indicator

3-digit 7-segment display (white),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

NPN open collector/PNP Open collector selectable,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 10,000 lux or less
Sunlight: 20,000 lux or less at 240 mm 9.45"*4
Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less at 490 mm 19.29"*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM, Nut: SUS316L, Lock washer: SUS304

Accompanying items

Instruction Manual,
FDA warning/certification/identification label,
Laser warning/explanation labels

Weight

Approx. 75 g

*1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. (LR-ZH490CB : Only when PNP output is selected.) You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office.
*2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

Keyence New Stock Image
Keyence LV-N12P Keyence
Sale price 2,727.00 kr
Only 7 units left

Specifications

Model

LV-N12P

Type

2 output

Output

PNP

Cable/connector

Cable

Main/Expansion unit

Expansion unit

I/O

Control outputs

2 output

External input

1 input

Monitor output

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.

Control outputs

PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less

Response time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Monitor output

-

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Number of interference
prevention units

Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

Case size

H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

Unit expansion

Up to 17 units can be connected in total (two-output type is treated as two units)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

Power
consumption

Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6
Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6
Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
*7

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)*8

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Cable

PVC

Case

Main unit and cover material: Polycarbonate

Weight

Approx. 65 g

*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
*3 These numbers double when "DOUBLE" is selected.
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 To connect more than 9 units, the power voltage must be 20 V or more.
*6 Increases 30 mW (1 mA) for HIGH SPEED mode.
*7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

Keyence New Stock Image
Keyence LV-N11P Keyence
Sale price 2,620.00 kr
Only 9 units left

Specifications

Model

LV-N11P

Type

2 output

Output

PNP

Cable/connector

Cable

Main/Expansion unit

Main unit

I/O

Control outputs

2 output

External input

1 input

Monitor output

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.

Control outputs

PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less

Response time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Monitor output

-

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Number of interference
prevention units

Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

Case size

H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

Unit expansion

Up to 17 units can be connected in total (two-output type is treated as two units)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

Power
consumption

Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6
Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6
Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
*7

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)*8

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Cable

PVC

Case

Main unit and cover material: Polycarbonate

Weight

Approx. 75 g

*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
*3 These numbers double when "DOUBLE" is selected.
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 To connect more than 9 units, the power voltage must be 20 V or more.
*6 Increases 30 mW (1 mA) for HIGH SPEED mode.
*7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

Keyence New Stock Image
Keyence LV-N11CP Keyence
Sale price 2,404.00 kr
In stock, 11 units

Specifications

Model

LV-N11CP

Type

1 output

Output

PNP

Cable/connector

M8 connector

Main/Expansion unit

Main unit

I/O

Control outputs

1 output

External input

1 input

Monitor output

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
Timer duration selectable: 1 ms to 9,999 ms,
Maximum error against the setting value: ±10% max.

Control outputs

PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
(Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
(Multiple connections) 1 output max: 20 mA or less

Response time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Monitor output

-

External input

Input time 2 ms (ON)/20 ms (OFF) or more*2

Number of interference
prevention units

Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

Case size

H 32.6 mm 1.28" × W 9.8 mm 0.39" × L 78.7 mm 3.1"

Unit expansion

Up to 17 units can be connected in total (two-output type is treated as two units)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS*4*5

Power
consumption

Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*6
Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*6
Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
*7

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)*8

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Cable

PVC

Case

Main unit and cover material: Polycarbonate

Weight

Approx. 20 g

*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
*2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
*3 These numbers double when "DOUBLE" is selected.
*4 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*5 To connect more than 9 units, the power voltage must be 20 V or more.
*6 Increases 30 mW (1 mA) for HIGH SPEED mode.
*7 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
(1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
*8 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F. When using 2-outputs, one unit is counted as two units.

FS-V31CP Keyence
Keyence FS-V31CP Keyence
Sale price 2,196.00 kr
In stock, 64 units

Specifications

Model

FS-V31CP

Type

1-output + 1-input
with M8 connector

Output

PNP

Main unit/Expansion unit

Main unit

Control output

1 output

Monitor output (1 to 5 V)

N/A

External input

1 input

Connector

M8

Light source LED

Red, 4-element LED (Wavelength: 640 nm)

Response time

33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO)

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Operation indicator: Red LED/Dual digital monitor: Dual 7-segment display, Preset Value (4-digit green LED indicator) and
Current Value (4-digit red LED indicator) illuminated together. Current Value range: 0 to 64,512; Excess gain: 0P to 999P,
Hold function: Possible to display both peak and bottom hold values, Selectable from 5 variations
Bar LED monitor: Excess gain displayed (85% to 115% in 7 steps), Scaling display

Size

30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D)

Detection mode

Light intensity (area detection possible, automatic sensitivity-tracking function provided)

Timer function

OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable
Timer duration selectable: 0.1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.

Control output

PNP open-collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max.

External inputy

Input time: 2 ms (ON)/20 ms (OFF) min.*2

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units.

Number of interference prevention units

Normal operation

HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Power consumption

Normal: 750 mW max. (Using 24 V, 31 mA max., using 12 V, 40 mA max.)/
Power saving 580 mW max. (Using 24 V, 24 mA max., using 12 V,
28 mA max.)*3

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

N/A

Weight

Approx. 80 g

*1 Total current of two outputs should be less than 100 mA.
*2 Only available on certain models.
*3 When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA).
*4 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
1 to 2 Units: -10 to +55 °C 14 to 131 °F, 3 to 10 Units: -10 to +50 °C 14 to 122 °F, 11 to 16 Units: -10 to +45 °C 14 to 113 °F

Keyence New Stock Image
Keyence IG-028 Keyence
Sale price 8,630.00 kr
In stock, 15 units

Specifications

Model

IG-028

Operation principle

CCD method

Light source

Wavelength

660 nm (Visible light semiconductor laser)

FDA

Class 1*1

IEC/JIS

Class 1

Mounting distance

0 to 1500 mm 59.06"

Measurement range

28 mm 1.10"

Sampling cycle

980 µs (When the number of times for averaging is set to [hsp]: 490 µs)

Minimum detectable object

High sensitivity mode

ø0.1 mm ø0.003" (Setting distance: 100 mm 3.94")*2

Standard mode

ø0.2 mm ø0.007" (Setting distance: 50 mm 1.97" or less),
ø0.5 mm ø0.02" (Setting distance: 500 mm 19.68")*2

Repeatability

5 µm 0.20 Mil (Setting distance: 100 mm 3.94")
10 µm 0.39 Mil (Setting distance: 500 mm 19.68")
80 µm 3.15 Mil (Setting distance: 1,000 mm 39.37")
140 µm 5.51 Mil (Setting distance: 1,500 mm 59.06")*3

Linearity

±0.1 % of F.S. (±28 µm ±1.10 Mil)*4

Temperature characteristics

±0.01 % of F.S./°C (±3 µm ±0.12 Mil/°C)*5

Operation indicator

Transmitter

Optical axis alignment indicator: Green LED, Power indicator: Green LED

Receiver

Optical axis alignment indicator: Green LED, Position monitor: Dual bar LED (Red, Green)

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp: 5,000 lux, Sunlight: 5,000 lux*6

Ambient temperature

-10 to +45 °C 14 to 113 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Case

Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part)

Lens cover

Glass

Cable

PVC

Accessories

Transmitter × 1, Receiver × 1, Sensor head cables (2 m 6.56') × 2

Weight

Approx. 500 g (including supplied items)

*1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 When the measurement target object is measured at the center position of the setting distance. When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm 0.003" or more can be detected (Setting distance: 500 mm 19.69").
*3 When the light is shielded by half at the center position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds. (When the analog output is used, the margin of error of analog output is added.)
*4 When the setting distance is 100 mm 3.94" and light is shielded at 50 mm 1.96"position from the receiver. Margin of error to the ideal line.
*5 When the setting distance is 100 mm 3.94" and light is shielded by half at 50 mm 1.96" position from the receiver.
*6 Excluding when the average number of times is set to [hsp].

Keyence New Stock Image
Keyence FU-13 Keyence
Sale price 2,123.00 kr
Only 8 units left

Specifications

Model

FU-13*1

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.0×2

Minimum bend radius

R2 mm0.079" Tough-Flex

Environmental resistance

Ambient temperature

-40 to +50 °C -40 to 122 °F

Weight

Approx. 8 g

*1 For details on the detecting distance, see the fiber amplifier catalog.

Keyence New Stock Image
Keyence GT2-H12K Keyence
Sale price 5,309.00 kr
In stock, 19 units

Specifications

Model

GT2-H12K

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

12 mm 0.47"

Resolution

0.1 μm 0.004 Mil

Indicated accuracy

1 µm 0.04 Mil (p-p)*1

Measuring force

Downward mounting

1.0 N*2

Side mounting

0.9 N*2

Upward mounting

0.8 N*2

Sampling cycle

1 ms

Mechanical response

10 Hz*1

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR

Dust boot

NBR

Contact

TYPE304 Stainless steel, super-tough tungsten alloy*3

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 95 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 The contact is included with the sensor.

Keyence New Stock Image
Keyence GT2-H12 Keyence
Sale price 4,664.00 kr
In stock, 15 units

Specifications

Model

GT2-H12

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

12 mm 0.47"

Resolution

0.5 μm 0.02 Mil

Indicated accuracy

2 µm 0.08 Mil (p-p)*1

Measuring force

Downward mounting

1.0 N*2

Side mounting

0.9 N*2

Upward mounting

0.8 N*2

Sampling cycle

1 ms

Mechanical response

10 Hz*1

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body cast: Zinc die-casting, Indicator: Polyarylate, Dust boot: NBR

Dust boot

NBR

Contact

TYPE304, 440C Stainless steel*3

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 95 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 The contact is included with the sensor.

Keyence New Stock Image
Keyence GT2-A50 Keyence
Sale price 10,111.00 kr
In stock, 13 units

Specifications

Model

GT2-A50

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

50 mm 1.97"

Resolution

0.5 μm 0.02 Mil

Indicated accuracy

3.5 µm 0.14 Mil (p-p)*1

Measuring force

Downward mounting

3.2 N*2

Side mounting

2.8 N*2

Upward mounting

2.4 N*2

Sampling cycle

1 ms

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67*3

Pressure resistance

1 MPa

Applied pressure range

0.25 to 0.5 MPa

Ambient temperature

0 to +55 °C 32 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions*4

Materials

Main body

Main body case: Zinc die-casting; Cylinder part: Aluminium alloy;
Air joint resin part: Polyacetal; Air joint metal part: Brass nickel plating; Indicator: Polyarylate

Dust boot

NBR

Contact

TYPE304, 440C Stainless steel*5

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 405 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 Make sure the air tube is connected to the air exhaust joint and that no foreign materials enter inside from the joint.
*4 In the case where a mounting bracket D is used with GT2-A32 and GT2-A50, the double amplitude becomes 0.75 mm 0.03".
*5 The contact is included with the sensor.

FS-N41C Keyence
Keyence FS-N41C Keyence
Sale price 2,594.00 kr
In stock, 32 units

Specifications

Model

FS-N41C*1

Type

M8 Connector*2

Main unit/expansion unit

Main unit

Response time

23 µs (S-HSPD*3) /50 µs (HSPD*4) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)

Number of control outputs

2*5

Number of external inputs

1*5

Light source LED

Transmitter side: Red, four-element LED (wavelength: 660 nm)

Control output

Open-collector, 30 V or less 100 mA or less per output,
100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)
Residual voltage
NPN 1.4 V or less (output current: 10 mA or less) /2 V or less (output current: 10 to 100 mA)
PNP 1.6 V or less (output current: 10 mA or less) /2.2 V or less (output current: 10 to 100 mA)

External input

Input time: 2 ms (ON) /20 ms (OFF) or longer*6

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

Mutual interference prevention

S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)

Power supply

Power voltage

10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*7

Power consumption

During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)
ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V)
ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less

Ambient temperature

-20 °C -4 °F to +55 °C +131 °F (no freezing)*9

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Shock resistance

500 m/s2; 3 times each for X, Y, and Z axes

Case material

Main unit and cover: polycarbonate

Weight

Approx. 25 g

*1 IO-Link Specifi cation V.1.1/COM2 (38.4 kbps) is supported.
*2 Ensure the cable length is 30 m 98.4" or less for the M8 connector type. Ensure the cable length is 20 meters 65.6' or less when connecting by way of IO-Link.
*3 Restrictions when S-HSPD is selected
Output 2 of dual output types is fixed to OFF.
IO-Link communication cannot be used.
Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.
Output timer, Limit Detection, and Display Gain cannot be used.
FULL cannot be selected for the ECO function.
*4 Restrictions when HSPD is selected
Display Gain cannot be used.
*5 Output 2 and the external input are selectable.
*6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.
*7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.
*8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.
*9 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.
When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.
The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.
Exercise special care when installing the product in an airtight space.

Keyence New Stock Image
Keyence LR-W70C Keyence
Sale price 4,233.00 kr
Only 9 units left

Specifications

Model

LR-W70C

Type

Small/Dual Spot Type
M12 connector 4-pin type

Detecting distance

30 to 70 mm 1.18" to 2.76"

Min. spot diameter

Approx. 1.6 x 2.9mm at 50 mm 0.06" × 0.11" at 1.97"

Light source

White LED

Mutual interference reduction function

Up to 2 units when alternate frequencies set

Timer

OFF/ON delay/OFF delay/One-shot

Response time

1-Spot Mode: 200 µs, 1 ms, 10 ms, 100 ms, 500 ms selectable
2-Spot Mode, Difference Monitoring: 500 µs, 2.5 ms, 20 ms, 200 ms, 999 ms selectable
2-Spot Mode, 2-Point Matching: 400 µs, 2 ms, 20 ms, 200 ms, 999 ms selectable*1

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, remaining voltage: 2 V or less
N.O./N.C. selectable
*2

External input

Tuning /Transmission OFF selectable
Short circuit current: 1 mA or less for NPN/2 mA or less for PNP
For the applied voltage, see the wiring diagrams in the instruction manual.
For the input times, see the time charts in the instruction manual.
*2

Protection circuit

Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Power supply

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

60 mA or less (without load) at 24 VDC;
110 mA or less (without load) at 12 VDC)*3

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less

Ambient temperature

-20 to +50 °C -4 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover: PPSU, Buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating),
Connector ring: PMP, Connector socket: PEI

Weight

Approx. 75 g

*1 When alternate frequencies are set, the response time increases by approximately 20%.
*2 IO-Link: Specification v.1.1/COM2 (38.4 kbps) is supported. The setup file can be downloaded from KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*3 180 mA or less (at 10 V, with load)

Keyence New Stock Image
Keyence PZ-G61N Keyence
Sale price 1,071.00 kr
Only 9 units left

Specifications

Model

PZ-G61N

Type

Retro-reflective *1
Long-range
(with P.R.O.
function)

Shape

Rectangular

Output

NPN

Cable connection

Cable (2 m 78.74") *2

Detecting distance

0.1 to 4.2 m
0.3' to 13.8'
(When R-2L
reflector
is used)

Spot diameter

Light source

Red LED

Sensitivity adjustment

1-turn trimmer (230°)

Response time

500 µs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicators (LED)

Output: Orange LED,
Stable operation: Green LED

Control output

Open collector output, 30 V max., 100 mA max., Residual voltage: 1 V max.

Protection circuit

Reversed polarity, overcurrent protection, surge absorber

Interference suppression

Up to 2 units
(with the automatic different frequency function)

Tightening torque

Rectangular models (Mounting hole part): 0.5 N m max.

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %

Current consumption

34 mA or less

Environmental resistance

Enclosure rating

IEC: IP67/NEMA: 4A, 6, 12/DIN: IP69K

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Housing, M18 nut
(threaded models only)

Glass-fiber reinforced PBT

Lens cover

Acrylic
(PMMA)

Trimmer

Glass-fiber reinforced polyamide (PA)

Case connection

Screw: Nickel-plated iron and zinc, packing: nitrile butadiene rubber (NBR)

Cable (cable models only)

Polyvinyl chloride (PVC)

Connector (connector type with cable only)

Accessories

Instruction manual

Weight

Rectangular cable models: Approx. 60 g (Thrubeam-models transmitter: Approx. 50 g)

*1 Cable sold separately for connector models/pigtail quick disconnect models. Reflector sold separately for retro-reflective models.
*2 Cable sold separately for connector models

Keyence New Stock Image
Keyence PZ-G101CP Keyence
Sale price 1,544.00 kr
Only 10 units left

Specifications

Model

PZ-G101CP

Type

Diffuse Reflective, Narrow view reflective

Shape

Rectangular

Output

PNP

Cable connection

M8 connector *1

Detecting distance

200 mm
7.87"

Spot diameter

Approx. 5 mm
0.20" dia.
(At a detecting
distance of
100 mm 3.94")

Light source

Red LED

Sensitivity adjustment

1-turn trimmer (230°)

Response time

500 µs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicators (LED)

Output: Orange LED,
Stable operation: Green LED

Control output

Open collector output, 30 V max., 100 mA max., Residual voltage: 1 V max.

Protection circuit

Reversed polarity, overcurrent protection, surge absorber

Interference suppression

Up to 2 units
(with the automatic different frequency function)

Tightening torque

Rectangular models (Mounting hole part): 0.5 N m max.

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %

Current consumption

34 mA or less

Environmental resistance

Enclosure rating

IEC: IP67/NEMA: 4A, 6, 12/DIN: IP69K

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Housing, M18 nut
(threaded models only)

Glass-fiber reinforced PBT

Lens cover

Polyarylate (PAR)

Trimmer

Glass-fiber reinforced polyamide (PA)

Case connection

Screw: Nickel-plated iron and zinc, packing: nitrile butadiene rubber (NBR)

Cable (cable models only)

Polyvinyl chloride (PVC)

Connector (connector type with cable only)

Accessories

Instruction manual

Weight

Rectangular connector models: Approx. 10 g

*1 Cable sold separately for connector models

Keyence New Stock Image
Keyence LR-ZB250CP Keyence
Sale price 2,727.00 kr
In stock, 11 units

Specifications

Model

LR-ZB250CP

Type

Distance based laser sensor

Appearance

Rectangular

Output

PNP

Cable connection

M8 connector, 4-pin

Detectable distance

35 to 250 mm 1.38" to 9.84" (215 to 0)*1

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 250 mm 7.09" to 9.84": 25 mm 0.98"

Display resolution

1 to 3 (1 to 3 mm 0.04" to 0.12")

Spot size

Approx. 2.4 × 1.2 mm 0.09" × 0.05" at 250 mm 9.84"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 55 g

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

Keyence New Stock Image
Keyence NQ-MP8L Keyence
Sale price 7,045.00 kr
Only 5 units left

Specifications

Model

NQ-MP8L

Network Specifications

Compatible Networks

EtherNet/IP™, PROFINET, Modbus/TCP

Communication Speed

10 Mbps/100 Mbps

Connector

M12 4-pin female D-code

Power Supply Specifications

Connector Type

Power supply port IN: M12 5-pin male L-code
Power supply port OUT: M12 5-pin female L-code

Power Voltage

18 to 30 VDC
(During IO-Link communication: 20.4 V to 28.8 V)

Allowable Current

V1 and V2: max. 9 A each
V1 and V2: 11 A in total

Current Consumption

V1: max. 180 mA
V2: max. 90 mA

Sensor Connection Specifications

Connector Type

M12 5-pin female A-code

V1 Power Supply Capacity

Ports 1 and 5: Each port max. 4 A, with short-circuit protection
Ports 2 to 4, 6 to 8: Each port max. 2 A, with short-circuit protection

V2 Power Supply Capacity

Ports 5 and 6: Each port max. 4 A, with short-circuit protection
Ports 7 and 8: Each port max. 2 A, with short-circuit protection

IO-Link Specifications

Number of Connectable Devices

8

Compliant Standards

Ver1.1

Transmission Speed

COM1: 4.8 kbps
COM2: 38.4 kbps
COM3: 230.4 kbps

Port type

Ports 1 to 4: Class A
Ports 5 to 8: Class B*1

Process Data Size

Input: Max. 32 bytes/Output: Max. 32 bytes

Digital Input (DI) Specifications

Number of Inputs

Max. 12 (when using DI mode)

Input Type

PNP

ON Voltage/ON Current

11 V or higher/2 mA or higher

OFF Voltage/OFF Current

Less than 5 V/less than 1.5 mA

Input Current

Pin 2: approx. 7 mA, Pin 4: approx. 12 mA

Digital Output (DO) Specifications

Number of Outputs

Max. 4

Output Type

PNP

Maximum Load Current

Each port max. 2 A

Short-Circuit Protection Circuit

Yes

Leakage Current

0.1 mA or lower

Residual Voltage

1 V or lower

Environmental resistance

Enclosure rating

IP65/IP67/IP69K

Ambient temperature

-40°C to +70°C -40°F to +158°F (no freezing)

Vibration resistance

5 to 150 Hz/20 G/10 sweeps each in X, Y, and Z axes

Shock resistance

15 G/11 ms/3 times each in X, Y, and Z axes

Case Material

Housing: PA6-GF30
IP address settings switch cover: PEI
Connector: SUS303

Weight

Approx. 530 g 18.69 oz

*1 When using Class B, V1 and V2 each require a power supply.