This Modicon MCM safe relay output expansion module has 4 start/restart interlock inputs, 4 relays with 8 status outputs and is fitted with captive screw clamp terminals. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with screw clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe relay output module |
| Device short name | XPSMCM |
| Electrical Connection | Screw terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Number of Outputs | 4 relay |
| Discrete output number | 8 solid state 125 mA diagnostics) |
| Function of module | Monitoring safety actuators relay output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Maximum power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Switching voltage | 10 V DC |
| Associated fuse rating | 3.5 A, slow-blow |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Output type | Relay, 4 NO, volt-free |
| Quantity per Set | 1 |
| Switching time | 12 ms |
| Maximum switching voltage | 400 V AC 250 V DC |
| minimum switching current | 20 mA |
| Maximum switching current | 6 A |
| Number of terminal blocks | 6 |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 4 LEDs green/red RELAY K1...K4 relay contact 4 LEDs yellow RST requires reset 8 LEDs yellow STATUS diagnostics output |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block 1 captive screw clamp terminals, removable terminal block |
| Cable cross section | 0.0003â¦0.002 in² (0.2â¦1.5 mm²) - AWG 24...AWG 16 flexible without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.002 in² (0.25â¦1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0008â¦0.002 in² (0.5â¦1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel 0.0003â¦0.002 in² (0.2â¦1 mm²) - AWG 24...AWG 18 solid without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Depth | 4.5 in (114.5 mm) |
| Product Weight | 0.73 lb(US) (0.33 kg) |

The safe relay output module provides 4 outputs and 8 solid state at 125mA (diagnostics) discrete outputs. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe relay output module |
| Device short name | XPSMCM |
| Electrical Connection | Spring terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Number of Outputs | 4 relay |
| Discrete output number | 8 solid state 125 mA diagnostics) |
| Function of module | Monitoring safety actuators relay output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Maximum power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Switching voltage | 10 V DC |
| Associated fuse rating | 3.5 A, slow-blow |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Output type | Relay, 4 NO, volt-free |
| Quantity per Set | 1 |
| Switching time | 12 ms |
| Maximum switching voltage | 400 V AC 250 V DC |
| minimum switching current | 20 mA |
| Maximum switching current | 6 A |
| Number of terminal blocks | 4 |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 4 LEDs green/red RELAY K1...K4 relay contact 4 LEDs yellow RST reset |
| Connections - terminals | 1 spring clamp terminals, removable terminal block 2 spring clamp terminals, removable terminal block |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0008â¦0.002 in² (0.5â¦1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Depth | 4.5 in (114.5 mm) |
| Product Weight | 0.7 lb(US) (0.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Accessory / separate part designation | Plug-in spring connector |
| Accessory / Separate Part Type | Spring connector |
| Accessory / separate part category | Connection accessories |
| Product Compatibility | XPSMC16ZC XPSMC16Z XPSMC16ZP |
| Accessory / separate part destination | Configurable safety controller |
Complementary
| Characteristic | Value(s) |
|---|---|
| Wire stripping length | 0.4 in (10 mm) |
| Product Weight | 0.18 lb(US) (0.08 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Accessory / separate part designation | Plug-in spring connector |
| Accessory / Separate Part Type | Spring connector |
| Accessory / separate part category | Connection accessories |
| Product Compatibility | XPSMC32ZP XPSMC32ZC XPSMC32Z |
| Accessory / separate part destination | Configurable safety controller |
Complementary
| Characteristic | Value(s) |
|---|---|
| Wire stripping length | 0.4 in (10 mm) |
| Product Weight | 0.24 lb(US) (0.11 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Accessory / separate part designation | Plug-in screw connector |
| Accessory / Separate Part Type | Screw connector |
| Accessory / separate part category | Connection accessories |
| Product Compatibility | XPSMC16ZP XPSMC16Z XPSMC16ZC |
| Accessory / separate part destination | Configurable safety controller |
Complementary
| Characteristic | Value(s) |
|---|---|
| Tightening torque | 4.4â¦5.3 lbf.in (0.5â¦0.6 N.m) |
| Wire stripping length | 0.4 in (10 mm) |
| Product Weight | 0.18 lb(US) (0.08 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Accessory / separate part designation | Plug-in screw connector |
| Accessory / Separate Part Type | Screw connector |
| Accessory / separate part category | Connection accessories |
| Product Compatibility | XPSMC32Z XPSMC32ZC XPSMC32ZP |
| Accessory / separate part destination | Configurable safety controller |
Complementary
| Characteristic | Value(s) |
|---|---|
| Tightening torque | 4.4â¦5.3 lbf.in (0.5â¦0.6 N.m) |
| Wire stripping length | 0.4 in (10 mm) |
| Product Weight | 0.24 lb(US) (0.11 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Software Designation | XPSMCWIN |
| Product or Component Type | Configuration software |
| Software Type | Configuration software |
| Software Version | V2.10 (update file for V2.20 available in Schneider web site) |
| User Language | Portuguese Spanish Dutch English Italian French |
| Format | CD-ROM |
| Operating System | Windows 2000 Windows XP |
| Document type | User manual |
Complementary
| Characteristic | Value(s) |
|---|---|
| Software Function | Configuring safety controllers XPSMC..Z. |
| Product Weight | 1.15 lb(US) (0.52 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote input module |
| Safety module name | XPSMF1 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring short-circuit and line break remote line control output |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 16 not isolated |
| Number of outputs | 4 not isolated line control outputs |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | >= 15 V discrete input |
| Current state 0 guaranteed | 1...1.5 mA discrete input) |
| Current state 1 guaranteed | >= 2 mA discrete input) |
| Discrete input voltage | 19.2 V |
| Discrete input current | 40 mA |
| Input protection type | Protected against short-circuit |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Switching voltage | 7.5 V discrete input |
| Switching time | 250 µs discrete input |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 discrete output 1 power supply 4 discrete input |
| Current consumption | 0.8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 2.6 in (66.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 6.0 in (152 mm) |
| Product Weight | 1.5 lb(US) (0.7 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote output relay module |
| Safety module name | XPSMF2 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators Monitoring safety dialogue |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Number of outputs | 8 relay |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Associated fuse rating | 10 A, slow-blow |
| Output type | Relay, 2 NO per output, volt-free |
| Minimum switching voltage | 5 V 250 V AC output relay 5 V 250 V DC output relay |
| Switching current capacity | 3 A / 100 A with internal fuse relay output |
| Maximum switching capacity in VA | <240 VA 0.5 relay output |
| Maximum switching capacity in W | <90 / 30 V relay output <30 / 127 V relay output <35 / 70 V relay output |
| Contacts material | Silver alloy (Ag/Ni) relay output |
| Electrical durability | 250000 cycles relay output |
| Mechanical durability | 1000000 cycles relay output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 8 relay output |
| Current consumption | 0.6 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 3.4 in (86.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 8.1 in (207 mm) |
| Product Weight | 2.9 lb(US) (1.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety PLC compact |
| Safety module name | XPSMF35 |
| Safety module application | For numerous machine safety functions and for the protection of personnel |
| Safety use category | Category 4 EN 954-1/ISO 13849-1 SIL 3 IEC 61508 |
| Structure type | 10BASE-T/100BASE-TX, Modbus TCP/IP 10BASE-T/100BASE-TX, safe Ethernet |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Closed circuit scanning of input channels analogue input circuit Measuring 0 to 20 mA currents using shunt analogue input circuit Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Single-pole measuring of 0 to 10 V voltages analogue input circuit |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| No load current | 0.75 A |
| Protection Type | Internal fuse |
| Clock | With, supplied by backup capacitor for 1 week following loss of supply |
| Response Time | Depending on size of application |
| Memory description | User logic 250 kB application User logic 250 kB data |
| Discrete input number | 24 not isolated |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | 24...30 V discrete input |
| Current state 0 guaranteed | 1...1.5 mA discrete input) |
| Current state 1 guaranteed | 3.5...4.5 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 100 mA |
| Input protection type | Protected against short-circuit to earth Protected against short-circuit |
| Input overvoltage protection | 500 V discrete input IEC 61000-4-5 -4â¦15 V analogue input circuit |
| Discrete output number | 8 |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 2% |
| Discrete output current | 1 A 140 °F (60 °C) channels 4 and 8) 2 A 122 °F (50 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 mA all channels) |
| Minimum load | 2 mA per discrete output |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Overload protection | Shutdown of outputs concerned with cyclic reconnection |
| Analogue input number | 8 |
| Analogue Output Type | Not isolated |
| External resistance | 250 Ohm analogue input circuit 500 Ohm analogue input circuit |
| Analogue input range | 0...20 mA 500 Ohm 0...10 V |
| Input voltage limits | 0.1...11.5 V analogue input circuit |
| Input current limits | 0.4â¦23 mA 500 Ohm analogue input circuit |
| Analogue input resolution | 12 bits |
| Safety accuracy | +/- 2 % analogue input circuit |
| Maximum internal input resistance | 500 MOhm for signal source analogue input circuit 1 kOhm analogue input circuit 3.7 Ohm counting inputs |
| Counting input number | 2 |
| Counting input type | Non isolated |
| Counting frequency | 100 kHz |
| Operating threshold | 0...0.05 V, 5 V low counting inputs 13...33 V, 24 V high counting inputs -3...5 V, 24 V low counting inputs 4...6 V, 5 V high counting inputs |
| Counter inputs resolution | 24 bits |
| DV/dt | 1 V/µs counting inputs |
| Communication port protocol | Modbus TCP/IP 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Safe Ethernet 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Modbus RTU 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable |
| Exchange mode | Half duplex, full duplex, autonegotiation Modbus TCP/IP Half duplex, full duplex, autonegotiation safe Ethernet |
| Method of access | Slave Modbus Slave Modbus TCP/IP Slave Profibus |
| Number of addresses | 122 Modbus |
| Concept | Transparent Ready, Modbus TCP/IP |
| Web server | Class A10, Modbus TCP/IP |
| Web services | Modbus identification request, Modbus TCP/IP Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP Modbus TCP/IP server, Modbus TCP/IP Standard 502, Modbus TCP/IP |
| Operating distance | <= 500 m between station) shielded dual twisted pair cable counting inputs <= 100 m between station) discrete input <= 100 m between station) discrete output <= 300 m between station) analogue input circuit |
| Number of terminal blocks | 1 counting inputs 1 power supply 2 discrete output 4 analogue input circuit 5 discrete input |
| Connections - terminals | Analogue input circuit captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end Counting inputs captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible with cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible without cable end Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.25...2 x 1 mm² AWG 22...AWG 18) flexible without cable end Power supply captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² AWG 22...AWG 16) flexible with cable end Analogue input circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Counting inputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Analogue input circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end Counting inputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end Analogue input circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end Counting inputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end Analogue input circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end Counting inputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end Analogue input circuit captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end Counting inputs captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end Analogue input circuit captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end Counting inputs captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end Analogue input circuit captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end Counting inputs captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end |
| Tightening torque | 1.95â¦2.21 lbf.in (0.22â¦0.25 N.m) |
| Wire stripping length | 0.4 in (9 mm) |
| Current consumption | 9 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 2.6 in (66.5 mm) |
| Height | 4.4 in (113 mm) |
| Width | 10.0 in (253 mm) |
| Product Weight | 2.6 lb(US) (1.2 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Single-pole measuring of 0 to 10 V voltages Measuring, using shunt, 0/4 to 20 mA currents Closed circuit scanning of input channels |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Response Time | Depending on size of application |
| Analogue input number | 8 |
| Analogue Input Type | Not isolated |
| External resistance | 250 Ohm analogue input circuit 500 Ohm analogue input circuit |
| Analogue input range | 0...20 mA 500 Ohm 0...10 V |
| Input voltage limits | 0.1...11.5 V |
| Input current limits | 0.4â¦23 mA 500 Ohm |
| Analogue input resolution | 12 bits |
| Safety accuracy | +/- 2 % analogue input circuit |
| Maximum internal input resistance | 500 MOhm for signal source 2 Ohm |
| Input overvoltage protection | -4â¦15 V |
| Analogue output number | 4 |
| Analogue Output Type | Not isolated |
| Analogue output range | 4...20 mA |
| Output current limits | 0â¦20 mA |
| Analogue output resolution | 12 bits |
| Load impedance ohmic | <= 600 Ohm analogue output |
| Relative error | +/- 1 % |
| Maximum cable distance between devices | 11.8 in (300 mm) analogue input circuit 11.8 in (300 mm) analogue output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 5 analogue input/output circuit |
| Current consumption | 0.8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 8.1 in (207 mm) |
| Height | 4.3 in (109 mm) |
| Width | 3.8 in (97.5 mm) |
| Product Weight | 2.09 lb(US) (0.95 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators discrete input Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 16 not isolated |
| Number of outputs | 2 not isolated line control outputs |
| Discrete output number | 16, not isolated |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Associated fuse rating | 16 A, slow-blow |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | 15...< 30 V discrete input |
| Current state 0 guaranteed | 1...1.5 mA discrete input) |
| Current state 1 guaranteed | <= 2 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 40 mA |
| Input protection type | Protected against short-circuit |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Switching voltage | 7.5 V discrete input |
| Switching time | 250 µs |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 3 % |
| Discrete output current | > 10 mA 140 °F (60 °C) channels 1 to 3, 5 to 7, 4 and 8) 1 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 4 and 8) 2 A 104 °F (40 °C) channels 1 to 3, 5 to 7, 4 and 8) <= 9 A all channels) |
| Inductive load | 500 mH discrete output |
| Maximum tungsten load | <25 W discrete output |
| Maximum line resistance | 5 kOhm discrete output |
| Minimum load | 2 mA per channel |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 line control outputs 1 power supply 3 discrete output 4 discrete input |
| Current consumption | 14 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 3.4 in (86.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 8.07 in (205 mm) |
| Product Weight | 2.9 lb(US) (1.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators discrete input Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 20 not isolated |
| Discrete output number | 8, not isolated |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | 15...< 30 V discrete input |
| Current state 0 guaranteed | 1.25...1.5 mA discrete input) |
| Current state 1 guaranteed | <= 2 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 100 mA |
| Input protection type | Protected against short-circuit |
| Switching voltage | 7.5 V discrete input |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 2% |
| Discrete output current | 1 A 140 °F (60 °C) channels 4 and 8) 2 A 122 °F (50 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 A all channels) |
| Minimum load | 2 mA per channel |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 2 discrete input 2 discrete output |
| Current consumption | 8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 2.6 in (66.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 8.1 in (207 mm) |
| Product Weight | 2.2 lb(US) (1 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety remote mixed I/O module |
| Safety module name | XPSMF3 |
| Safety module application | Extension of I/O capacity |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Function of module | Monitoring safety actuators discrete input Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| Discrete input number | 8 not isolated |
| Number of outputs | 2 not isolated line control outputs |
| Discrete output number | 10, not isolated |
| Structure type | 10BASE-T/100BASE-TX |
Complementary
| Characteristic | Value(s) |
|---|---|
| Response Time | Depending on size of application |
| Associated fuse rating | 10 A, slow-blow |
| Voltage state 0 guaranteed | <= 5 V discrete input |
| Voltage state 1 guaranteed | 15...< 30 V discrete input |
| Current state 0 guaranteed | 1.25...1.5 mA discrete input) |
| Current state 1 guaranteed | <= 2 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 100 mA |
| Input protection type | Protected against short-circuit |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Switching voltage | 7.5 V discrete input |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 2% |
| Discrete output current | 1 A 140 °F (60 °C) channels 1 and 2) 1 A 140 °F (60 °C) channels 4 and 8) 2 A 104 °F (40 °C) channels 4 and 8) 0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7) <= 7 A all channels) |
| Inductive load | 500 mH discrete output |
| Maximum tungsten load | <10 W, channels 1 to 3 and 5 to 7 discrete output <25 W, channels 1 and 2 discrete output <25 W, channels 4 and 8 discrete output |
| Minimum load | 2 mA per channel |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better |
| Exchange mode | Half duplex, full duplex, autonegotiation |
| Number of terminal blocks | 1 power supply 2 discrete input 2 discrete output 2 line control outputs |
| Current consumption | 8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 2.6 in (66.5 mm) |
| Height | 4.3 in (109 mm) |
| Width | 6.0 in (152 mm) |
| Product Weight | 2.2 lb(US) (1 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety PLC compact |
| Safety module name | XPSMF40 |
| Safety module application | F use with numerous machine safety functions and for the protection of personel |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Structure type | 10BASE-T/100BASE-TX, Modbus TCP/IP 10BASE-T/100BASE-TX, safe Ethernet |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| No load current | 0.5 A |
| Protection Type | 10 A internal fuse |
| Clock | With, supplied by backup capacitor for 1 week following loss of supply |
| Response Time | Depending on size of application |
| Memory description | User logic 250 kB application User logic 250 kB data |
| Group of channels | 2 groups of 4 line control outputs |
| Discrete I/O number | 24 configurable |
| Maximum discrete input number | 24 not isolated |
| Voltage state 0 guaranteed | <= 24 V discrete input |
| Voltage state 1 guaranteed | 24...30 V discrete input |
| Current state 0 guaranteed | <= 1.5 mA discrete input) |
| Current state 1 guaranteed | 3.5...4.5 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 100 mA |
| Maximum input resistance | 7 kOhm |
| Input overvoltage protection | -10â¦35 V discrete input |
| Maximum discrete output number | 24 not isolated |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 2% |
| Discrete output current | 1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24) 2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24) 0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23) <= 7 A all channels) |
| Minimum load | 2 mA per discrete output |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Overload protection | Shutdown of outputs concerned with cyclic reconnection |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Modbus TCP/IP 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Modbus RTU 1 RJ45, RS485 shielded dual twisted pair cable |
| Exchange mode | Half duplex, full duplex, autonegotiation Modbus TCP/IP Half duplex, full duplex, autonegotiation safe Ethernet |
| Method of access | Slave Modbus TCP/IP Slave V0 Modbus serial |
| Number of addresses | 122 Modbus serial |
| Concept | Transparent Ready, Modbus TCP/IP |
| Web server | Class A10, Modbus TCP/IP |
| Web services | Modbus identification request, Modbus TCP/IP Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP Modbus TCP/IP server, Modbus TCP/IP Standard 502, Modbus TCP/IP |
| Maximum number of connections | 1 to 20, Modbus TCP/IP |
| Operating distance | <= 300 m between station discrete input <= 300 m between station discrete output |
| Number of terminal blocks | 1 power supply 2 line control outputs 6 discrete input/output circuit 8 line control outputs |
| Connections - terminals | Discrete input/output circuit captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end Line control outputs captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible with cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible without cable end Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end Line control outputs captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible with cable end Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible without cable end |
| Tightening torque | Discrete input/output circuit 1.95â¦2.21 lbf.in (0.22â¦0.25 N.m) captive screw clamp terminals Line control outputs 1.95â¦2.21 lbf.in (0.22â¦0.25 N.m) captive screw clamp terminals Power supply 4.4 lbf.in (0.5 N.m) captive screw clamp terminals |
| Wire stripping length | 0.4 in (10 mm) power supply captive screw clamp terminals 0.4 in (9 mm) discrete input/output circuit captive screw clamp terminals 0.4 in (9 mm) discrete input/output circuit captive spring terminals 0.4 in (9 mm) line control outputs captive screw clamp terminals 0.4 in (9 mm) line control outputs captive spring terminals 0.4 in (9 mm) power supply captive spring terminals |
| Current consumption | 8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 6.02 in (153 mm) |
| Height | 6.0 in (151.5 mm) |
| Width | 2.9 in (74 mm) |
| Product Weight | 2.2 lb(US) (1 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety PLC compact |
| Safety module name | XPSMF40 |
| Safety module application | F use with numerous machine safety functions and for the protection of personel |
| Safety use category | Category 4 maximum EN 954-1 Performance level e EN/ISO 13849-1 SIL 3 EN/IEC 61508 |
| Structure type | 10BASE-T/100BASE-TX, safe Ethernet |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Monitoring safety actuators discrete output Monitoring safety detection discrete input Monitoring safety dialogue discrete input Monitoring safety dialogue discrete output Monitoring short-circuit and line break line control outputs |
| [Us] Rated Supply Voltage | 24 V DC - 15...20 % |
| Supply | SELV or PELV EN/IEC 60950 |
| No load current | 0.5 A |
| Protection Type | 10 A internal fuse |
| Clock | With, supplied by backup capacitor for 1 week following loss of supply |
| Response Time | Depending on size of application |
| Memory description | User logic 250 kB application User logic 250 kB data |
| Group of channels | 2 groups of 4 line control outputs |
| Discrete I/O number | 24 configurable |
| Maximum discrete input number | 24 not isolated |
| Voltage state 0 guaranteed | <= 24 V discrete input |
| Voltage state 1 guaranteed | 24...30 V discrete input |
| Current state 0 guaranteed | <= 1.5 mA discrete input) |
| Current state 1 guaranteed | 3.5...4.5 mA discrete input) |
| Discrete input voltage | 20 V |
| Discrete input current | 100 mA |
| Maximum input resistance | 7 kOhm |
| Input overvoltage protection | -10â¦35 V discrete input |
| Maximum discrete output number | 24 not isolated |
| Discrete output voltage | 24 V DC |
| Output voltage tolerance | +/- 2% |
| Discrete output current | 1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24) 2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24) 0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23) <= 7 A all channels) |
| Minimum load | 2 mA per discrete output |
| Maximum leakage current | 1 mA 2 V at state 0 discrete output |
| Overload protection | Shutdown of outputs concerned with cyclic reconnection |
| Output voltage | 20 V line control outputs |
| Nominal output current | 60 mA line control outputs |
| Communication port protocol | Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable |
| Exchange mode | Half duplex, full duplex, autonegotiation safe Ethernet |
| Method of access | Slave V0 Profibus |
| Operating distance | <= 300 m between station discrete input <= 300 m between station discrete output |
| Number of terminal blocks | 1 power supply 2 line control outputs 6 discrete input/output circuit 8 line control outputs |
| Connections - terminals | Discrete input/output circuit captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end Line control outputs captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible with cable end Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible without cable end Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end Discrete input/output circuit captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end Line control outputs captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible with cable end Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible without cable end |
| Tightening torque | Discrete input/output circuit 1.95â¦2.21 lbf.in (0.22â¦0.25 N.m) captive screw clamp terminals Line control outputs 1.95â¦2.21 lbf.in (0.22â¦0.25 N.m) captive screw clamp terminals Power supply 4.4 lbf.in (0.5 N.m) captive screw clamp terminals |
| Wire stripping length | 0.4 in (10 mm) power supply captive screw clamp terminals 0.4 in (9 mm) discrete input/output circuit captive screw clamp terminals 0.4 in (9 mm) discrete input/output circuit captive spring terminals 0.4 in (9 mm) line control outputs captive screw clamp terminals 0.4 in (9 mm) line control outputs captive spring terminals 0.4 in (9 mm) power supply captive spring terminals |
| Current consumption | 8 A 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 6.02 in (153 mm) |
| Height | 6.0 in (151.5 mm) |
| Width | 2.9 in (74 mm) |
| Product Weight | 2.2 lb(US) (1 kg) |

This XPSMP safety contoller can handle 2 independent safety functions. This safety controller with pre-defined functions meets the requirements of PL e/Category 4 conforming EN ISO 13849-1 and SILCL 3 conforming to EN/IEC 61508 and EN/IEC 62061. It enables two independent safety functions (selected from a choice of 15 pre-defined configurations) to be performed using the same product. It complies with the most stringent functional safety requirements thanks to multiple configurable safety functions. It has additional solid-state output for communication with PLCs about safety status of your process.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safety controller with pre-defined function |
| Safety module name | XPSMP |
| Safety module application | 2 independent functions |
| Safety use category | Category 4 maximum EN/IEC 60954-1 |
| Type of start | Automatic or unmonitored 1) Automatic or unmonitored 10) Automatic or unmonitored 11) Automatic or unmonitored 14) Automatic or unmonitored 3) Automatic or unmonitored 5) Automatic or unmonitored 7) Monitored 12) Monitored 13) Monitored 15) Monitored 2) Monitored 4) Monitored 6) Monitored 8) Monitored 9) |
| Checks | Configuration 10) Configuration 13) Configuration 3) Configuration 4) Configuration 5) Configuration 6) Configuration 9) |
| Standards | EN/IEC 60947-1 + A11 EN/IEC 60947-5-1 EN/IEC 60204-1 DIN V VDE 801 + A1 |
| Product Certifications | UL CSA BIA |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Connections - terminals | Captive screw clamp terminals flexible 0.14...0.75 mm² without cable end, 2 wires Captive screw clamp terminals solid 0.14...0.75 mm² without cable end, 2 wires Captive screw clamp terminals flexible 0.14...2.5 mm² without cable end, 1 wire Captive screw clamp terminals solid 0.14...2.5 mm² without cable end, 1 wire Captive screw clamp terminals flexible 0.25...1 mm² with cable end, without bezel, 2 wires Captive screw clamp terminals flexible 0.25...1.5 mm² with cable end, with bezel, 1 wire Captive screw clamp terminals flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire Captive screw clamp terminals flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires |
| Safety level | Can reach PL e/category 4 EN/ISO 13849-1 Can reach SIL 3 EN/IEC 62061 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | 0 functions disabled (factory setting) 1 emergency stop monitoring 1-channel wiring, category 2 10 enabling grip switch monitoring (3-position switch), category 4 11 sensing mat and edges monitoring, category 3 12 sensing mat and edges monitoring, category 3 13 relay output safety light curtain monitoring, category 4 14 coded magnetic switch monitoring, category 4 15 coded magnetic switch monitoring, category 4 2 emergency stop monitoring 1-channel wiring, category 2 3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 9 guard monitoring for injection presses and blowing machines, category 4 |
| Synchronisation time between inputs | 0.5 s 13) 1.5 s 14) 1.5 s 15) 1.5 s 5) 1.5 s 6) 1.5 s 9) Unlimited 3) Unlimited 4) Unlimited 7) Unlimited 8) |
| Power Consumption in W | 5 W |
| Input protection type | Internal, electronic |
| [Uc] control circuit voltage | 24 V |
| Maximum line resistance | 100 Ohm <6561.7 ft (2000 m) |
| Number of safety circuits | 3 NO relays per function (6 NO total), volt-free |
| Number of additional circuits | 3 solid state outputs |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 20 mA 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 2 A for 1 output and 4 A for the other 2 outputs relay 3.3 A for all 3 outputs relay simultaneously 6 A for 1 output and 2 A for the other 2 outputs relay |
| [Ith] conventional free air thermal current | 20 A |
| Associated fuse rating | 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Maximum response time on input open | 30 ms |
| [Ui] rated insulation voltage | 300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 12 LEDs |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 4.5 in (114 mm) |
| Height | 3.9 in (99 mm) |
| Width | 1.8 in (45 mm) |
| Product Weight | 0.71 lb(US) (0.32 kg) |