This XPSDME safety module monitors 6 coded magnetic switches. It meets the requirements of PL c/Category 2 conforming to EN/ISO 13849-1.and SILCL1 conforming to EN/IEC 61508 and EN/IEC 62061. Used in conjunction with XU2S single-beam photo-electric sensors (periodically tested), it establishes a category 2 light curtain conforming to IEC/EN 61496 parts 1 and 2. It has additional solid-state output for communication with PLCs about safety status of your process.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety module |
| Safety module name | XPSDME |
| Safety module application | Monitoring 6 coded magnetic switches |
| Function of module | Coded magnetic switch monitoring |
| Safety level | Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061 |
| Safety reliability data | DC > 99 % EN/ISO 13849-1 MTTFd = 82.4 years EN/ISO 13849-1 PFHd = 3.97E-9 1/h EN/IEC 62061 |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Output type | Relay, 2 NO, volt-free |
| Number of additional circuits | 2 solid state outputs |
Complementary
| Characteristic | Value(s) |
|---|---|
| Synchronisation time between inputs | < 0.5 s |
| Power Consumption in W | 3.5 W |
| Input protection type | Internal, electronic |
| [Uc] control circuit voltage | 28 V DC |
| Maximum line resistance | 100 Ohm |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 6 A per relay relay output |
| [Ith] conventional free air thermal current | 12 A |
| Associated fuse rating | 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local signalling | 15 LEDs |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Current consumption | 8 mA 28 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.7 lb(US) (0.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Preventa Safety automation |
| Product or component type | Preventa safety module |
| Safety module name | XPSECME |
| Safety module application | Increasing the number of safety contacts |
| Function of module | Increasing the number of safety contacts |
| Safety level | Can reach PL e/category 4 can reach the maximum safety level of module base conforming to EN/ISO 13849-1 Can reach SILCL 3 can reach the maximum safety level of module base conforming to EN/IEC 62061 |
| Safety reliability data | MTTFd = 100 years conforming to EN/ISO 13849-1 DC = 60...90 % conforming to EN/ISO 13849-1 PFHd = 2E-7 1/h conforming to EN/IEC 62061 |
| Output type | Relay, 4 NO circuit(s), volt-free |
| [Us] rated supply voltage | 24 V AC/DC - 15...10 % |
| Number of additional circuits | 3 NC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Power consumption in VA | 5 VA |
| Input protection type | Internal, electronic |
| Breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
| Breaking capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 20 mA at 24 V for solid state output circuit |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 12 A for relay output |
| Associated fuse rating | 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 17 V for relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 2 LEDs |
| Connections - terminals | Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel Spring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel |
| Mounting support | 35 mm symmetrical DIN rail |
| Product weight | 0.27 kg |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Preventa Safety automation |
| Product or component type | Preventa safety module |
| Safety module name | XPSECME |
| Safety module application | Increasing the number of safety contacts |
| Function of module | Increasing the number of safety contacts |
| Safety level | Can reach PL e/category 4 can reach the maximum safety level of module base conforming to EN/ISO 13849-1 Can reach SILCL 3 can reach the maximum safety level of module base conforming to EN/IEC 62061 |
| Safety reliability data | MTTFd = 100 years conforming to EN/ISO 13849-1 DC = 60...90 % conforming to EN/ISO 13849-1 PFHd = 2E-7 1/h conforming to EN/IEC 62061 |
| Output type | Relay, 4 NO circuit(s), volt-free |
| [Us] rated supply voltage | 24 V AC/DC - 15...10 % |
| Number of additional circuits | 3 NC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Power consumption in VA | 5 VA |
| Input protection type | Internal, electronic |
| Breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
| Breaking capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 20 mA at 24 V for solid state output circuit |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 12 A for relay output |
| Associated fuse rating | 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 17 V for relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 2 LEDs |
| Connections - terminals | Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Mounting support | 35 mm symmetrical DIN rail |
| Product weight | 0.27 kg |

This XPSECME safety module allows to expand the number of safety contacts available on XPS base modules. It is supplied with 24V AC/DC, has 4 safety circuits, 2 additional outputs and removable spring terminals. This safety module meets the requirements of PL e/Category 4 conforming to EN/ISO 13849- and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061 (when connected to the appropriate module). It allows extension of the number of safety contacts, are available as additions to Preventa XPS base modules (Emergency stop, limit switch, two-hand control, etc.). 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has spring terminals for fast and reliable wiring of safety circuits.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety module |
| Safety module name | XPSECME |
| Safety module application | Increasing the number of safety contacts |
| Function of module | Increasing the number of safety contacts |
| Safety level | Can reach PL e/category 4 can reach the maximum safety level of module base EN/ISO 13849-1 Can reach SILCL 3 can reach the maximum safety level of module base EN/IEC 62061 |
| Safety reliability data | MTTFd = 100 years EN/ISO 13849-1 DC = 60...90 % EN/ISO 13849-1 PFHd = 2E-7 1/h EN/IEC 62061 |
| Output type | Relay, 4 NO, volt-free |
| [Us] Rated Supply Voltage | 24 V AC/DC - 15...10 % |
| Number of additional circuits | 3 NC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Power Consumption in VA | 5 VA |
| Input protection type | Internal, electronic |
| Breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
| Breaking capacity | 1.5 A 24 V DC-13)50 ms relay output 20 mA 24 V solid state output circuit |
| Output thermal current | 6 A per relay relay output |
| [Ith] conventional free air thermal current | 12 A relay output |
| Associated fuse rating | 6 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 2 LEDs |
| Connections - terminals | Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel Spring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.60 lb(US) (0.27 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Preventa Safety automation |
| Product or component type | Preventa safety module |
| Safety module name | XPSECPE |
| Safety module application | Increasing the number of safety contacts |
| Function of module | Increasing the number of safety contacts |
| Safety level | Can reach PL e/category 4 can reach the maximum safety level of module base conforming to EN/ISO 13849-1 Can reach SILCL 3 can reach the maximum safety level of module base conforming to EN/IEC 62061 |
| Safety reliability data | MTTFd > 100 years conforming to EN/ISO 13849-1 DC = 0...99 % conforming to EN/ISO 13849-1 PFHd = 2.47E-8 1/h conforming to EN/IEC 62061 |
| Output type | Relay, 8 NO circuit(s), volt-free |
| [Us] rated supply voltage | 115...230 V AC - 15...10 % |
| Number of additional circuits | 2 NC + 1 solid state output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Power consumption in VA | 6 VA |
| Input protection type | Internal, electronic |
| Breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
| Breaking capacity | 3 A at 24 V (DC-13) time constant: 50 ms for relay output 20 mA at 24 V for solid state output circuit |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 24 A for relay output |
| Associated fuse rating | 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 5 V for relay output |
| Maximum response time on input open | 10 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 3 LEDs |
| Connections - terminals | Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Spring terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Spring terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end Spring terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end Spring terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Spring terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Mounting support | 35 mm symmetrical DIN rail |
| Product weight | 0.65 kg |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Preventa Safety automation |
| Product or component type | Preventa safety module |
| Safety module name | XPSECPE |
| Safety module application | Increasing the number of safety contacts |
| Function of module | Increasing the number of safety contacts |
| Safety level | Can reach PL e/category 4 can reach the maximum safety level of module base conforming to EN/ISO 13849-1 Can reach SILCL 3 can reach the maximum safety level of module base conforming to EN/IEC 62061 |
| Safety reliability data | MTTFd > 100 years conforming to EN/ISO 13849-1 DC = 0...99 % conforming to EN/ISO 13849-1 PFHd = 2.47E-8 1/h conforming to EN/IEC 62061 |
| Output type | Relay, 8 NO circuit(s), volt-free |
| [Us] rated supply voltage | 115...230 V AC - 15...10 % |
| Number of additional circuits | 2 NC + 1 solid state output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Power consumption in VA | 6 VA |
| Input protection type | Internal, electronic |
| Breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
| Breaking capacity | 3 A at 24 V (DC-13) time constant: 50 ms for relay output 20 mA at 24 V for solid state output circuit |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 24 A for relay output |
| Associated fuse rating | 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 5 V for relay output |
| Maximum response time on input open | 10 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 3 LEDs |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 2 x 0.2...2 x 1 mm² solid without cable end Captive screw clamp terminals, 2 x 0.2...2 x 1 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Mounting support | 35 mm symmetrical DIN rail |
| Product weight | 0.65 kg |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Preventa Safety automation |
| Product or component type | Preventa safety module |
| Safety module name | XPSECPE |
| Safety module application | Increasing the number of safety contacts |
| Function of module | Increasing the number of safety contacts |
| Safety level | Can reach PL e/category 4 can reach the maximum safety level of module base conforming to EN/ISO 13849-1 Can reach SILCL 3 can reach the maximum safety level of module base conforming to EN/IEC 62061 |
| Safety reliability data | MTTFd > 100 years conforming to EN/ISO 13849-1 DC = 0...99 % conforming to EN/ISO 13849-1 PFHd = 2.47E-8 1/h conforming to EN/IEC 62061 |
| Output type | Relay, 8 NO circuit(s), volt-free |
| [Us] rated supply voltage | 24 V AC - 15...10 % 24 V DC - 15...10 % |
| Number of additional circuits | 2 NC + 1 solid state output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Power consumption in VA | 4 VA |
| Input protection type | Internal, electronic |
| Breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
| Breaking capacity | 3 A at 24 V (DC-13) time constant: 50 ms for relay output 20 mA at 24 V for solid state output circuit |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 24 A for relay output |
| Associated fuse rating | 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 5 V for relay output |
| Maximum response time on input open | 10 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 3 LEDs |
| Connections - terminals | Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Spring terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Spring terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end Spring terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end Spring terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Spring terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Mounting support | 35 mm symmetrical DIN rail |
| Product weight | 0.65 kg |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Preventa Safety automation |
| Product or component type | Preventa safety module |
| Safety module name | XPSECPE |
| Safety module application | Increasing the number of safety contacts |
| Function of module | Increasing the number of safety contacts |
| Safety level | Can reach PL e/category 4 can reach the maximum safety level of module base conforming to EN/ISO 13849-1 Can reach SILCL 3 can reach the maximum safety level of module base conforming to EN/IEC 62061 |
| Safety reliability data | MTTFd > 100 years conforming to EN/ISO 13849-1 DC = 0...99 % conforming to EN/ISO 13849-1 PFHd = 2.47E-8 1/h conforming to EN/IEC 62061 |
| Output type | Relay, 8 NO circuit(s), volt-free |
| [Us] rated supply voltage | 24 V AC - 15...10 % 24 V DC - 15...10 % |
| Number of additional circuits | 2 NC + 1 solid state output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Power consumption in VA | 4 VA |
| Input protection type | Internal, electronic |
| Breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
| Breaking capacity | 3 A at 24 V (DC-13) time constant: 50 ms for relay output 20 mA at 24 V for solid state output circuit |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 24 A for relay output |
| Associated fuse rating | 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 5 V for relay output |
| Maximum response time on input open | 10 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
| Local signalling | 3 LEDs |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 2 x 0.2...2 x 1 mm² solid without cable end Captive screw clamp terminals, 2 x 0.2...2 x 1 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Mounting support | 35 mm symmetrical DIN rail |
| Product weight | 0.55 kg |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Configurable safety controller |
| Safety module name | XPSMC |
| Safety use category | Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum ISO 13849-1 SIL 3 maximum IEC 61508 |
| Type of start | Configurable |
| Standards | EN 1760-1/ISO 13856-1 EN 574/ISO 13851 IEC 60947-5-1 IEC 61508 IEC 60204-1 EN 954-1/EN/ISO 13849-1 IEC 61496-1 |
| Product Certifications | UL CSA TÃV |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Number of inputs | 16 |
| Communication port protocol | Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps Profibus 1 SUB-D 9-pin female, serial link 12 Mbps |
| Safety level | Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring category 4 EN/IEC 61496 Monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851 Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 IEC 61496 Two-hand control category 3 EN 574/ISO 13851 |
| Synchronisation time between inputs | Depending on configuration selected |
| Power Consumption in W | 12 W |
| Input protection type | External fuse 16 A |
| [Uc] control circuit voltage | 28.8 V |
| Maximum line resistance | 100 Ohm <6561.7 ft (2000 m) |
| Output type | 2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output |
| [Ith] conventional free air thermal current | 16 A relay output 6.5 A static output circuit |
| Associated fuse rating | 16 A gL power supply 4 A gL relay output 6 A fast blow relay output |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Response Time | Configurable : 20 ms or 30 ms with software XPSMCWIN |
| [Ui] rated insulation voltage | 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1 |
| Method of access | Slave |
| Exchange size | 14 words |
| Number of addresses | 1â¦125 Profibus 1â¦247 Modbus |
| Parity | Even Modbus No Modbus Odd Modbus |
| Data format | 1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode |
| Supported modbus function | 01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors |
| Local signalling | 32 LEDs |
| Mounting Support | Mounting plate |
| Depth | 6.02 in (153 mm) |
| Height | 6.0 in (151.5 mm) |
| Width | 2.9 in (74 mm) |
| Product Weight | 1.81 lb(US) (0.82 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Kit configurable safety controller |
| Safety module name | XPSMC |
| Safety use category | Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum EN/ISO 13849-1 SIL 3 maximum IEC 61508 |
| Type of start | Configurable |
| Standards | EN 1760-1/ISO 13856-1 EN 954-1/EN/ISO 13849-1 EN/IEC 60947-5-1 EN 574/ISO 13851 IEC 61508 EN/IEC 61496-1 EN/IEC 60204-1 |
| Product Certifications | CSA TÃV UL |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Number of inputs | 16 |
| Communication port protocol | Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps |
| Safety level | Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Kit composition | Set of cage clamp terminals Set of screw terminals Ethernet cable 2m Configuration software Connection cable VDE slot screwdriver 2.5 x 75 mm Safety controller Packaging small model for software configuration Printed packaging label 80 x 50 mm USB/RS485 converter |
| Function of module | Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring Monitoring safety stop at top dead centre on eccentric press Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 EN/IEC 61496 Two-hand control category 3 EN 574/ISO 13851 |
| Synchronisation time between inputs | Depending on configuration selected |
| Power Consumption in W | 12 W |
| Input protection type | External fuse 16 A |
| [Uc] control circuit voltage | 28.8 V |
| Maximum line resistance | 100 Ohm <6561.7 ft (2000 m) |
| Output type | 2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output |
| [Ith] conventional free air thermal current | 16 A relay output 6.5 A static output circuit |
| Associated fuse rating | 16 A gL power supply 4 A gL relay output 6 A fast blow relay output |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Response Time | Configurable : 20 ms or 30 ms with software XPSMCWIN |
| [Ui] rated insulation voltage | 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1 |
| Method of access | Slave |
| Exchange size | 14 words |
| Number of addresses | 1â¦247 Modbus |
| Parity | Even Modbus No Modbus Odd Modbus |
| Data format | 1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode |
| Supported modbus function | 01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors |
| Local signalling | 30 LEDs |
| Mounting Support | Mounting plate |
| Depth | 6.02 in (153 mm) |
| Height | 6.0 in (151.5 mm) |
| Width | 2.9 in (74 mm) |
| Product Weight | 1.81 lb(US) (0.82 kg) |

This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for serial link communication with Modbus protocol. Transmission rate are 1200/2400/4800/9600 and 19200bps, and another SUB-D 9-pin male port for CANopen communication. Transmission rate are 20/50/125 and 250kbps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÃV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Configurable safety controller |
| Safety module name | XPSMC |
| Safety use category | Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum ISO 13849-1 SIL 3 maximum IEC 61508 |
| Type of start | Configurable |
| Standards | IEC 60947-5-1 EN 574/ISO 13851 EN 1760-1/ISO 13856-1 IEC 61496-1 IEC 61508 EN 954-1/EN/ISO 13849-1 IEC 60204-1 |
| Product Certifications | UL TÃV CSA |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Number of inputs | 32 |
| Communication port protocol | CANopen 1 SUB-D 9-pin male, serial link 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps |
| Safety level | Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring category 4 EN/IEC 61496 Monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851 Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 IEC 61496 Two-hand control category 3 EN 574/ISO 13851 |
| Synchronisation time between inputs | Depending on configuration selected |
| Power Consumption in W | 12 W |
| Input protection type | External fuse 16 A |
| [Uc] control circuit voltage | 28.8 V |
| Maximum line resistance | 100 Ohm <6561.7 ft (2000 m) |
| Output type | 2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output |
| [Ith] conventional free air thermal current | 16 A relay output 6.5 A static output circuit |
| Associated fuse rating | 16 A gL power supply 4 A gL relay output 6 A fast blow relay output |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Response Time | Configurable : 20 ms or 30 ms with software XPSMCWIN |
| [Ui] rated insulation voltage | 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1 |
| Method of access | Slave |
| Exchange size | 14 words |
| Number of addresses | 1â¦127 CANopen 1â¦247 Modbus |
| Parity | Even Modbus No Modbus Odd Modbus |
| Data format | 1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode |
| Supported modbus function | 01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors |
| Local signalling | 48 LEDs |
| Mounting Support | Mounting plate |
| Depth | 6.02 in (153 mm) |
| Height | 6.0 in (151.5 mm) |
| Width | 2.9 in (74 mm) |
| Product Weight | 1.85 lb(US) (0.84 kg) |

This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for a serial link communication with Modbus protocol. The transmission rate are 1200bps, 2400bps, 4800bps, 9600bps or 19200bps, and 1 SUB-D 9-pin female port for PROFIBUS communication. The transmission rate is 12Mbps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÃV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Configurable safety controller |
| Safety module name | XPSMC |
| Safety use category | Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum ISO 13849-1 SIL 3 maximum IEC 61508 |
| Type of start | Configurable |
| Standards | EN 954-1/EN/ISO 13849-1 IEC 61496-1 IEC 61508 IEC 60204-1 EN 1760-1/ISO 13856-1 EN 574/ISO 13851 IEC 60947-5-1 |
| Product Certifications | CSA UL TÃV |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Number of inputs | 32 |
| Communication port protocol | Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps Profibus 1 SUB-D 9-pin female, serial link 12 Mbps |
| Safety level | Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Function of module | Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring category 4 EN/IEC 61496 Monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851 Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 IEC 61496 Two-hand control category 3 EN 574/ISO 13851 |
| Synchronisation time between inputs | Depending on configuration selected |
| Power Consumption in W | 12 W |
| Input protection type | External fuse 16 A |
| [Uc] control circuit voltage | 28.8 V |
| Maximum line resistance | 100 Ohm <6561.7 ft (2000 m) |
| Output type | 2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output |
| [Ith] conventional free air thermal current | 16 A relay output 6.5 A static output circuit |
| Associated fuse rating | 16 A gL power supply 4 A gL relay output 6 A fast blow relay output |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Response Time | Configurable : 20 ms or 30 ms with software XPSMCWIN |
| [Ui] rated insulation voltage | 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1 |
| Method of access | Slave |
| Exchange size | 14 words |
| Number of addresses | 1â¦125 Profibus 1â¦247 Modbus |
| Parity | Even Modbus No Modbus Odd Modbus |
| Data format | 1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode |
| Supported modbus function | 01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors |
| Local signalling | 48 LEDs |
| Mounting Support | Mounting plate |
| Depth | 6.02 in (153 mm) |
| Height | 6.0 in (151.5 mm) |
| Width | 2.9 in (74 mm) |
| Product Weight | 1.85 lb(US) (0.84 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Kit configurable safety controller |
| Safety module name | XPSMC |
| Safety use category | Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum EN/ISO 13849-1 SIL 3 maximum IEC 61508 |
| Type of start | Configurable |
| Standards | EN 954-1/EN/ISO 13849-1 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 61496-1 IEC 61508 EN 574/ISO 13851 EN 1760-1/ISO 13856-1 |
| Product Certifications | UL CSA TÃV |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Number of inputs | 32 |
| Communication port protocol | Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps |
| Safety level | Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Kit composition | Safety controller Ethernet cable 2m Configuration software Connection cable Set of cage clamp terminals USB/RS485 converter Set of screw terminals Packaging small model for software configuration VDE slot screwdriver 2.5 x 75 mm Printed packaging label 80 x 50 mm |
| Function of module | Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring Monitoring safety stop at top dead centre on eccentric press Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 EN/IEC 61496 Two-hand control category 3 EN 574/ISO 13851 |
| Synchronisation time between inputs | Depending on configuration selected |
| Power Consumption in W | 12 W |
| Input protection type | External fuse 16 A |
| [Uc] control circuit voltage | 28.8 V |
| Maximum line resistance | 100 Ohm <6561.7 ft (2000 m) |
| Output type | 2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output |
| [Ith] conventional free air thermal current | 16 A relay output 6.5 A static output circuit |
| Associated fuse rating | 16 A gL power supply 4 A gL relay output 6 A fast blow relay output |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Response Time | Configurable : 20 ms or 30 ms with software XPSMCWIN |
| [Ui] rated insulation voltage | 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1 |
| Method of access | Slave |
| Exchange size | 14 words |
| Number of addresses | 1â¦247 Modbus |
| Parity | Even Modbus No Modbus Odd Modbus |
| Data format | 1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode |
| Supported modbus function | 01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors |
| Local signalling | 46 LEDs |
| Mounting Support | Mounting plate |
| Depth | 6.02 in (153 mm) |
| Height | 6.0 in (151.5 mm) |
| Width | 2.9 in (74 mm) |
| Product Weight | 1.85 lb(US) (0.84 kg) |

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

This Modicon MCM backplane expansion connector is used to connect the various expansion modules to the safety controller CPU. This backplane connector provides a safe communication between safe expansion components and the safety controller CPU. its connectors are 1 male + 1 female connectors, 5-pin for rear panel plug-in connector. It weighs 0.01kg. The modular safety controllers Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. This single backplane expansion connector is compatible with the expansion modules and the safety controllers CPU. The backplane expansion connector instals Omega 35 mm DIN rail conforming to IEC 60715. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Accessory / separate part category | Expansion bus connector |
| Accessory / Separate Part Type | Backplane expansion bus connector |
| Product Compatibility | Logic controller Extension modules |
| Accessory / separate part destination | For modular device |
Complementary
| Characteristic | Value(s) |
|---|---|
| Electrical connection | 1 male + 1 female connectors - 5-pin rear panel plug-in connector |
| Quantity per Set | 1 |
| Mounting support | Omega 35 mm DIN rail IEC 60715 |
| Product Weight | 0.02 lb(US) (0.01 kg) |

This Modicon MCM standard ("non-safe") communication module has one EtherCAT connection with two RJ45 (in/out) connectors. It is designed to monitor remotely your safety system with the commonly used EtherCAT protocol, without additional gateways. It has a rated supply voltage of 24V DC. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The non-safe communication modules are designed for diagnostics connection and data communication purposes to machine field bus or network systems. Its transmission rate is 100Mbit/s for full duplex bus length. This communication module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. The maximum cable distance between two devices is 100m. This Modicon MCM standard ("non-safe") communication module is certified by RCM, CULus and TÃV. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The communication module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon MCM |
| Product or Component Type | Non-safe communication module |
| Device short name | XPSMCM |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power dissipation in W | 3 W |
| Quality labels | CE |
| Range Compatibility | Preventa XPSMCM |
| Connector type | RJ45 |
| Number of port | 2 |
| Method of access | Server |
| Transmission rate | 100 Mbit/s for full duplex |
| Communication Port Protocol | EtherCAT |
| Current Consumption | 0.125 mA |
| Maximum cable distance between devices | 328.08 ft (100 m) |
| Local signalling | LED green PWR power ON LED green RUN operating LED red E IN internal error LED red E EX external error LED green/red ERR communication error LED green/red STS operating |
| Connections - terminals | 2 spring clamp terminals, removable terminal block |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0008â¦0.002 in² (0.5â¦1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Depth | 4.5 in (114.5 mm) |
| Product Weight | 0.7 lb(US) (0.3 kg) |