Filters

Safety

763 products

Showing 25 - 48 of 763 products

Showing 25 - 48 of 763 products
View
Keyence New Stock Image
Keyence SC-S11 Keyence
Sale price 8,328.00 kr
Only 9 units left

Specifications

Model

SC-S11

Response time

25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON)

Safety output (S-OUTPUT)

Output

Two PNP outputs

Max. load current

500 mA

Residual voltage (when ON)

2.5 V maximum (with a load current of 500 mA)

Leakage current

1.2 mA maximum

Max. capacitive load

2.2 µF (with a load resistance of 100 Ω)

Load wiring length

30 m maximum

Safety input (S-INPUT, enable input)

Input type

Contact output device connection or PNP output device connection

Short-circuit current

Approx 5mA

ON/OFF voltage

Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less

Wiring length

30 m maximum

Safety related input

Input type

Non-voltage contact input (EDM input, reset input)

Short-circuit current

EDM input: Approx. 10 mA, Reset input: Approx. 5 mA (EDM input, reset input)

Wiring length

30 m max. (EDM input, reset input)

Non-safety output

Output

PNP/NPN totem pole output (auxiliary output, lockout output)

Max. load current

50mA (auxiliary output, lockout output)

Load wiring length

10 m maximum (auxiliary output, lockout output)

Non-safety input

Input type

No-voltage contact input or PNP or NPN open-collector input (external off input)

Short-circuit current

Approx 5mA (external off input)

ON/OFF voltage

Voltage when product turned on: 5 V or less or 19 V or more, voltage when product turned off: open or 9 V to 15 V (external off input)

Wiring length

10 m maximum (external off input)

Protection circuit

Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection

Approved standards

EMC

EMS

IEC 61496-1, EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A

Safety

ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508,*1

Rating

Power voltage

24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

1.3 A (at maximum load)

Environmental resistance

Enclosure rating

IP20 (IEC60529)
Must be installed within a control panel rated at IP54 or higher.

Pollution degree

2 (IEC60664/EN50178)

Overvoltage category

2 (IEC60664, EN50178)

Insulation resistance

100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-20 to +65 °C -4 to 149 °F (No freezing)

Storage relative humidity

35 to 85 % RH

Withstand voltage

1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Polycarbonate (UL94-V2)

Weight

160 g or less

*1 The following mark is displayed on the ratings indication label on the side of the main unit to identify it as a UL508-certified product.

keyence Stock Image
Keyence GS-51PCSO(3195) Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-51PCSO(3195)

Lock type

Power-to-release type

Type

Standard type

Response time

Lock

Lock→Unlock

220 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 380 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

Keyence New Stock Image
Keyence GS-51P5 Keyence
Sale price 3,120.00 kr
Only 7 units left

Specifications

Model

GS-51P5

Lock type

Power-to-release type

Type

Standard type

Response time

Lock

Lock→Unlock

220 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 560 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

Keyence Stock Image
Keyence GS-51P10 Keyence
Sale price 9,083.00 kr
Only 5 units left

Specifications

Model

GS-51P10

Lock type

Power-to-release type

Type

Standard type

Response time

Lock

Lock→Unlock

220 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 770 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-51N5 Keyence
Sale price 10,608.00 kr
Only 2 units left

Specifications

Model

GS-51N5

Lock type

Power-to-release type

Type

Standard type

Response time

Lock

Lock→Unlock

220 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 100 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 560 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-51N10 Keyence
Sale price 15,909.00 kr
Only 3 units left

Specifications

Model

GS-51N10

Lock type

Power-to-release type

Type

Standard type

Response time

Lock

Lock→Unlock

220 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 100 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 770 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-13PC Keyence
Sale price 10,282.00 kr
Only 5 units left

Specifications

Model

GS-13PC

Type

Advanced function type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

-

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

Approx. 5.0 mA × 1

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 80 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-13P5 Keyence
Sale price 4,149.00 kr
Only 1 unit left

Specifications

Model

GS-13P5

Type

Advanced function type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

-

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

Approx. 5.0 mA × 1

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 280 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-11PCSO(3194) Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-11PCSO(3194)

Type

Standard type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

Max. 4 units*2

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

-

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*3

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 80 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When AUX outputs of each unit are not used, it is possible to cascade up to 10 units.
*3 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

Keyence New Stock Image
Keyence GS-11P5 Keyence
Sale price 6,450.00 kr
Only 7 units left

Specifications

Model

GS-11P5

Type

Standard type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

-

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

-

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 270 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

Keyence Stock Image
Keyence GS-11P10 Keyence
Sale price 3,120.00 kr
Only 8 units left

Specifications

Model

GS-11P10

Type

Standard type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

-

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

-

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 480 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-11N5 Keyence
Sale price 4,835.00 kr
Only 5 units left

Specifications

Model

GS-11N5

Type

Standard type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

-

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 100 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

-

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 270 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-11N10 Keyence
Sale price 5,456.00 kr
Only 4 units left

Specifications

Model

GS-11N10

Type

Standard type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

Max. 30 units

Using Y-shaped connector

-

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 100 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

-

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 480 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-10PCSO(3193) Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-10PCSO(3193)

Type

Simple function type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

-

Using Y-shaped connector

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

-

Reset/EDM input

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 80 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence GS-Y13N Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-Y13N

Type

End Terminal for NPN models

Weight

Approx.10 g 0.35 oz

keyence Stock Image
Keyence GS-MB31 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-MB31

Type

Sliding door
mounting bracket

Applicable model

for GS-ML5 Series

Frame size

30 - 40 mm 1.18" - 1.57"

Weight

Approx. 270 g 9.52 oz

keyence Stock Image
Keyence GS-MB23 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-MB23

Type

Hinged door
mounting bracket

Applicable model

for GS-M9 Series

Frame size

40 - 45 mm 1.57" - 1.77"

Weight

Approx. 90 g 3.17 oz

keyence Stock Image
Keyence GS-MB22 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-MB22

Type

Hinged door
mounting bracket

Applicable model

for GS-M9 Series

Frame size

30 - 40 mm 1.18" - 1.57"

Weight

Approx. 120 g 4.23 oz

keyence Stock Image
Keyence GS-MB21 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-MB21

Type

Hinged door
mounting bracket

Applicable model

for GS-M9 Series

Frame size

30 - 40 mm 1.18" - 1.57"

Weight

Approx. 85 g 3.00 oz

keyence Stock Image
Keyence GS-MB13 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GS-MB13

Type

Hinged door
mounting bracket

Applicable model

for GS-M5 Series

Frame size

40 - 45 mm 1.57" - 1.77"

Weight

Approx. 130 g 4.59 oz

keyence Stock Image
Keyence GS-MB12 Keyence
Sale price 5,963.00 kr
Only 1 unit left

Specifications

Model

GS-MB12

Type

Hinged door
mounting bracket

Applicable model

for GS-M5 Series

Frame size

30 - 40 mm 1.18" - 1.57"

Weight

Approx. 110 g 3.88 oz

Keyence Stock Image
Keyence GS-MB11 Keyence
Sale price 1,612.00 kr
Only 9 units left

Specifications

Model

GS-MB11

Type

Hinged door
mounting bracket

Applicable model

for GS-M5 Series

Frame size

30 - 40 mm 1.18" - 1.57"

Weight

Approx. 120 g 4.23 oz

keyence Stock Image
Keyence GS-MAL5U Keyence
Sale price 9,170.00 kr
Only 2 units left

Specifications

Model

GS-MAL5U

Type

Coding level: High

Applicable model

Sliding door model GS-ML5 Series

keyence Stock Image
Keyence GS-MAL5M Keyence
Sale price 10,612.00 kr
Only 3 units left

Specifications

Model

GS-MAL5M

Type

Coding level: Low

Applicable model

Sliding door model GS-ML5 Series

Recently viewed