Safety
763 products
Showing 1 - 24 of 763 products

Specifications
Model |
GC-1000 |
|||
Input/output points |
Safety inputs |
16 |
||
Safety outputs |
6 |
|||
Safety relay output |
- |
|||
AUX outputs |
4 |
|||
Test outputs | ||||
Maximum number of connectable expansion units |
10*1 |
|||
Maximum number of connectable remote I/O modules |
4 |
|||
GC-Link ports |
2 ports |
|||
Safety input specifications |
Input device |
Contact output device or PNP output device |
||
Input type |
Type3 |
|||
ON level (voltage/current) |
Min. 11 V/2 mA |
|||
OFF level (voltage/current) |
Max. 5 V/1.5 mA |
|||
Short-circuit current |
Si 0 to 3: Approx. 5 mA |
|||
Protection circuit |
Surge protection circuit, wrong wiring protection circuit |
|||
Maximum cable length |
Max. 100 m 328.1' |
|||
Safety output specifications |
Output type |
PNP transistor output (DC-13, Type 0.5, Protected outputs)*2 |
||
Maximum load current |
500 mA |
|||
Residual voltage (during ON) |
Max. 2.0 V |
|||
Leakage current (during OFF) |
Max. 0.5mA |
|||
Maximum capacitive load |
0.5 µF |
|||
Load wiring resistance |
Max. 2.5Ω |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 30 m 98.4' |
|||
Safety relay output specifications |
Output type |
- |
||
Rated load (resistance load) | ||||
Rated load (inductive load) | ||||
Relay output mechanical life | ||||
Maximum cable length | ||||
B10d | ||||
Test output specifications |
Output type |
PNP transistor output*3 |
||
Maximum load current |
100 mA |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 100 m 328.1'*4 |
|||
AUX output specifications |
Output type |
Transistor output (PNP/NPN selectable by wiring) |
||
Maximum load current |
PNP: 100 mA, NPN: 20 mA |
|||
Residual voltage (during ON) |
Max. 2.0 V |
|||
Leakage current (during OFF) |
Max. 0.5 mA |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 30 m 98.4' |
|||
Communication interface |
USB |
USB2.0 |
||
Ethernet |
100BASE-TX |
|||
Network functionality |
EtherNet/IP™ *5, PROFINET, Modbus/TCP, MC protocol, UDP |
|||
Others |
LCD display |
1.77-inch color LCD |
||
Display buttons |
4 points (3 operation keys + 1 BACK key) |
|||
Applicable standards |
EMC |
EMS: IEC 61131-2/-6, EN61131-2/-6 |
||
Safety |
IEC 61508, EN 61508 SIL3 |
|||
Dimensions |
60×95×90 mm 2.36"× 3.74"×3.54" (W×D×H) |
|||
Power supply |
Power voltage |
24 VDC (-30 to +20%) Class 2 |
||
Power consumption |
Max. 200 mA |
|||
Environmental resistance |
Ambient temperature |
−10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
5 to 85% (No condensation) |
|||
Storage temperature |
−25 to +70 °C -13 to 158 °F (No freezing) |
|||
Operating altitude |
Max. 2000 m 6561.7' |
|||
Overvoltage category |
II |
|||
Pollution degree |
2 |
|||
Vibration resistance |
Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14" |
|||
Shock resistance |
Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 260 g |
|||
*1 The bus extension unit “GC-B30” is not included in this number, and only one set of “GC-B30” can be used per setup. | ||||
Scroll

Specifications
Model |
SL-T11R |
|||
Combined light curtain |
SL-V Series |
|||
Output |
FSD1、2 |
230 VAC/4 A, 30 VDC/2 A (Resistance load) |
||
Life-span |
Mechanical life: 10 million cycles or more/Electrical life: 0.1 million cycle or more*1 |
|||
Response time (ms) |
ON→OFF |
+6 ms |
||
OFF→ON |
+15 ms |
|||
Approved standards |
EMC |
EMS |
UL61496-1, IEC61496-1, EN61496-1 |
|
EMI |
FCC Part15B Class A, ICES-003 Class A, EN55011 Class A |
|||
Safety |
UL61496-1, IEC61496-1, EN61496-1 (Type 4 ESPE), ISO 13849-1: 2015 (Cat 4 PLe), UL508, EN50178 |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
100 mA or less (at 24 VDC, SL-T11R alone) |
|||
Environmental resistance |
Enclosure rating |
IP20 (IEC60529), Set inside control panel with IP54 or more |
||
Pollution degree |
2 |
|||
Overvoltage category |
III |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 330 g |
|||
*1 For the specifications for the outputs other than FSD and for each input, refer to the SL-V Instruction Manual. | ||||
Scroll

Specifications
Model |
GS-71P5 |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 560 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-51PC |
|||
Lock type |
Power-to-release type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
220 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-11PC |
|||
Type |
Standard type |
|||
Operating distance |
Front |
Sao(OFF→ON) |
10 mm 0.39" |
|
Sar(ON→OFF) |
18 mm 0.71" |
|||
Side |
Sao(OFF→ON) |
6 mm 0.24" |
||
Sar(ON→OFF) |
14 mm 0.55" |
|||
Response time |
Detection |
Detect→Not detect |
20 ms + 2 ms × (number of units cascaded -1)*1 |
|
Not detect→Detect |
30 ms + 25 ms × (number of units cascaded -1)*1 |
|||
Door operation |
Acceptable operation frequency |
3 Hz |
||
Cascading |
Standard |
Max. 30 units |
||
Using Y-shaped connector |
Max. 4 units*2 |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 500 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max.2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx. 1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508 (SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
0.8 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250) |
||
Operating ambient temperature |
-20°C to +55°C -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*3 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
Zinc die cast (Nickel chrome plating), PBT, PAR |
|
Cable |
PVC |
|||
Actuator |
Case |
SUS430, SUS304, PBT |
||
Weight |
Approx. 80 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-10PC |
|||
Type |
Simple function type |
|||
Operating distance |
Front |
Sao(OFF→ON) |
10 mm 0.39" |
|
Sar(ON→OFF) |
18 mm 0.71" |
|||
Side |
Sao(OFF→ON) |
6 mm 0.24" |
||
Sar(ON→OFF) |
14 mm 0.55" |
|||
Response time |
Detection |
Detect→Not detect |
20 ms + 2 ms × (number of units cascaded -1)*1 |
|
Not detect→Detect |
30 ms + 25 ms × (number of units cascaded -1)*1 |
|||
Door operation |
Acceptable operation frequency |
3 Hz |
||
Cascading |
Standard |
- |
||
Using Y-shaped connector | ||||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 500 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max.2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
- |
||
Reset/EDM input | ||||
Applicable Standards (Safety) |
EN 61508, IEC 61508 (SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
0.8 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250) |
||
Operating ambient temperature |
-20°C to +55°C -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*2 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
Zinc die cast (Nickel chrome plating), PBT, PAR |
|
Cable |
PVC |
|||
Actuator |
Case |
SUS430, SUS304, PBT |
||
Weight |
Approx. 80 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-MA5M |
|||
Type |
Coding level: Low |
|||
Applicable model |
Standard model GS-M5 Series |
|||
Scroll

Specifications
Model |
GC-S84 |
|||
Input/output points |
Safety inputs |
8 |
||
Safety outputs |
4 (PNP) |
|||
Safety relay output |
- |
|||
AUX outputs | ||||
Test outputs |
2 |
|||
Safety input specifications |
Input device |
Contact output device or PNP output device |
||
Input type |
Type3 |
|||
ON level (voltage/current) |
Min. 11 V/2 mA |
|||
OFF level (voltage/current) |
Max. 5 V/1.5 mA |
|||
Short-circuit current |
Approx. 3 mA |
|||
Protection circuit |
Surge protection circuit, wrong wiring protection circuit |
|||
Maximum cable length |
Max. 100 m 328.1' |
|||
Safety output specifications |
Output type |
PNP transistor output (DC-13, Type 0.5, Protected outputs)*1 |
||
Maximum load current |
500 mA |
|||
Residual voltage (during ON) |
Max. 2.0 V |
|||
Leakage current (during OFF) |
Max. 0.5 mA |
|||
Maximum capacitive load |
0.5 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 30 m 98.4' |
|||
Safety relay output specifications |
Output type |
- |
||
Rated load (resistance load) | ||||
Rated load (inductive load) | ||||
Relay output mechanical life | ||||
Maximum cable length | ||||
B10d | ||||
Test output specifications |
Output type |
PNP transistor output*2 |
||
Maximum load current |
100 mA*2 |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit*2 |
|||
Maximum cable length |
Max. 100 m 328.1'*3*2 |
|||
AUX output specifications |
Output type |
- |
||
Maximum load current | ||||
Residual voltage (during ON) | ||||
Leakage current (during OFF) | ||||
Protection circuit | ||||
Maximum cable length | ||||
Applicable standards |
EMC |
EMS: IEC 61131-2/-6, EN61131-2/-6,EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A |
||
Safety |
IEC 61508, EN 61508 SIL3, IEC62061 SIL CL3, ISO/EN 13849-1:2015 Cat. 4, PL e, UL1998 |
|||
Dimensions |
22.2×95×90 mm 0.87"×3.74"×3.54" (W×D×H) |
|||
Power supply |
Power voltage |
24 VDC (-20 to +20%) Class 2 |
||
Power consumption |
Max. 60 mA |
|||
Environmental resistance |
Ambient temperature |
−10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
5 to 85% (No condensation) |
|||
Storage temperature |
-25 to +70 °C -13 to 158 °F (No freezing) |
|||
Operating altitude |
Max. 2000 m 6561.7' |
|||
Overvoltage category |
II |
|||
Pollution degree |
2 |
|||
Vibration resistance |
Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14" |
|||
Shock resistance |
Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 130 g |
|||
*1 Paragraph 6.4.6 Temporary overload of IEC 61131-2 supports up to 1.2 times the maximum load current. | ||||
Scroll

Specifications
Model |
GC-S1R |
|||
Input/output points |
Safety inputs |
- |
||
Safety outputs | ||||
Safety relay output |
1 (3a) |
|||
AUX outputs |
- |
|||
Test outputs | ||||
Safety input specifications |
Input device |
|||
Input type | ||||
ON level (voltage/current) | ||||
OFF level (voltage/current) | ||||
Short-circuit current | ||||
Protection circuit | ||||
Maximum cable length | ||||
Safety output specifications |
Output type |
|||
Maximum load current | ||||
Residual voltage (during ON) | ||||
Leakage current (during OFF) | ||||
Maximum capacitive load | ||||
Load wiring resistance | ||||
Protection circuit | ||||
Maximum cable length | ||||
Safety relay output specifications |
Output type |
Relay (3a) (Externally-protected outputs)*1 |
||
Rated load (resistance load) |
250 VAC 6A / 30 VDC 6A*2 |
|||
Rated load (inductive load) |
240 VAC 2A (AC-15) / 24 VDC 1A (DC-13) |
|||
Relay output mechanical life |
Resistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 times |
|||
Maximum cable length |
Max. 100 m 328.1' |
|||
B10d |
With rated load: 400,000 |
|||
Test output specifications |
Output type |
- |
||
Maximum load current | ||||
Protection circuit | ||||
Maximum cable length | ||||
AUX output specifications |
Output type |
|||
Maximum load current | ||||
Residual voltage (during ON) | ||||
Leakage current (during OFF) | ||||
Protection circuit | ||||
Maximum cable length | ||||
Applicable standards |
EMC |
EMS: IEC 61131-2/-6, EN61131-2/-6,EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A |
||
Safety |
IEC 61508, EN 61508 SIL3, IEC62061 SIL CL3, ISO/EN 13849-1:2015 Cat. 4, PL e, UL1998 |
|||
Dimensions |
39.6×95×90 mm 1.56"×3.74"×3.54" (W×D×H) |
|||
Power supply |
Power voltage |
- |
||
Power consumption |
Max. 80 mA |
|||
Environmental resistance |
Ambient temperature |
−10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
5 to 85% (No condensation) |
|||
Storage temperature |
-25 to +70 °C -13 to 158 °F (No freezing) |
|||
Operating altitude |
Max. 2000 m 6561.7' |
|||
Overvoltage category |
II (III for relay output part) |
|||
Pollution degree |
2 |
|||
Vibration resistance |
Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14" |
|||
Shock resistance |
Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 180 g |
|||
*1 To comply with the requirements of IEC61131-2, connect 10 A fast blow fuse (IEC 60217) in series to each contact. | ||||
Scroll

Specifications
Model |
GS-ML51P |
|||
Type |
For sliding door M12 Connector Standard |
|||
Holding force when locked |
500N |
|||
Holding force when unlocked |
Approx. 30N *1 |
|||
Cascading |
Max. 20 units |
|||
Operating distance |
Sao(OFF→ON) |
0.1 mm 0.004" *2 |
||
Sar(ON → OFF) |
15 mm 0.59" *2 |
|||
Response time (ms) |
Lock→Unlock |
250 ms *3 |
||
Unlock→Lock | ||||
Detect→ Not detect |
20 ms + 2 ms × (number of cascaded unit -1) *3 |
|||
Not detect→ Detect |
300 ms + 25 ms × (number of cascaded unit -1) *3 |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
150 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
0.8 μF |
|||
Load wiring resistance |
Max. 2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V(with a cable of 5 m 16.4') |
|||
External input (Short-circuit current) |
Safety input |
Approx. 1.5 mA × 2 |
||
Reset/EDM input |
Approx. 5 mA |
|||
Lock control input |
Approx. 2.5 mA |
|||
OSSD operation switching input |
Approx. 2.5 mA |
|||
Applicable Standards (Safety) |
EN61508, IEC61508(SIL3), EN ISO13849-1:2015(PL e, Category 4), |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10% or less, Class2) |
||
Power consumption |
5 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC60529) |
||
Operating ambient temperature |
-20 to 55°C -4 to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25 to 70°C -13 to 158°F(No freezing) *4 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis |
|||
Material |
Main unit |
PBT, PET/PAR, TPC, PC, Nickel-plated steel |
||
Actuator |
PBT, SUS304, Nickel-plated steel |
|||
Mounting bracket |
Aluminum, Painted steel (screw: Steel) |
|||
Weight |
Main unit |
Approx.240 g |
||
Actuator |
Approx.130 g 4.59 oz |
|||
*1 When the actuator is pulled first after unlocked, the holding force increases. | ||||
Scroll

Specifications
Model |
GC-1000R |
|||
Input/output points |
Safety inputs |
14 |
||
Safety outputs |
4 |
|||
Safety relay output |
1 (3a) |
|||
AUX outputs |
4 |
|||
Test outputs | ||||
Maximum number of connectable expansion units |
- |
|||
Maximum number of connectable remote I/O modules | ||||
GC-Link ports |
2 ports |
|||
Safety input specifications |
Input device |
Contact output device or PNP output device |
||
Input type |
Type3 |
|||
ON level (voltage/current) |
Min. 11 V/2 mA |
|||
OFF level (voltage/current) |
Max. 5 V/1.5 mA |
|||
Short-circuit current |
Si 0 to 3: Approx. 5 mA |
|||
Protection circuit |
Surge protection circuit, wrong wiring protection circuit |
|||
Maximum cable length |
Max. 100 m 328.1' |
|||
Safety output specifications |
Output type |
PNP transistor output (DC-13, Type 0.5, Protected outputs)*1 |
||
Maximum load current |
500 mA |
|||
Residual voltage (during ON) |
Max. 2.0 V |
|||
Leakage current (during OFF) |
Max. 0.5mA |
|||
Maximum capacitive load |
0.5 µF |
|||
Load wiring resistance |
Max. 2.5Ω |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 30 m 98.4' |
|||
Safety relay output specifications |
Output type |
Relay (3a) (Externally-protected outputs)*2 |
||
Rated load (resistance load) |
250 VAC 6A / 30 VDC 6A*3 |
|||
Rated load (inductive load) |
240 VAC 2A (AC-15) / 24 VDC 1A (DC-13) |
|||
Relay output mechanical life |
Resistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 times |
|||
Maximum cable length |
Max. 100 m 328.1' |
|||
B10d |
With rated load: 400,000 times |
|||
Test output specifications |
Output type |
PNP transistor output*4 |
||
Maximum load current |
100 mA |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 100 m 328.1'*5 |
|||
AUX output specifications |
Output type |
Transistor output (PNP/NPN selectable by wiring) |
||
Maximum load current |
PNP: 100 mA, NPN: 20 mA |
|||
Residual voltage (during ON) |
Max. 2.0 V |
|||
Leakage current (during OFF) |
Max. 0.5 mA |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 30 m 98.4' |
|||
Communication interface |
USB |
USB2.0 |
||
Ethernet |
- |
|||
Network functionality | ||||
Others |
LCD display |
1.77-inch color LCD |
||
Display buttons |
4 points (3 operation keys + 1 BACK key) |
|||
Applicable standards |
EMC |
EMS: IEC 61131-2/-6, EN61131-2/-6 |
||
Safety |
IEC 61508, EN 61508 SIL3 |
|||
Dimensions |
85×95×90 mm 3.35"×3.74"×3.54" (W×D×H) |
|||
Power supply |
Power voltage |
24 VDC (-20 to +20%) Class 2 |
||
Power consumption |
Max. 200 mA |
|||
Environmental resistance |
Ambient temperature |
−10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
5 to 85% (No condensation) |
|||
Storage temperature |
−25 to +70 °C -13 to 158 °F (No freezing) |
|||
Operating altitude |
Max. 2000 m 6561.7' |
|||
Overvoltage category |
II |
|||
Pollution degree |
2 |
|||
Vibration resistance |
Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14" |
|||
Shock resistance |
Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 360 g |
|||
*1 Paragraph 6.4.6 Temporary overload of IEC 61131-2 supports up to 1.2 times the maximum load current. | ||||
Scroll

Specifications
Model |
GS-M51P |
|||
Type |
For hinged door Small M12 Connector Standard |
|||
Holding force when locked |
500N |
|||
Holding force when unlocked |
Approx. 30N *1 |
|||
Cascading |
Max. 20 units |
|||
Operating distance |
Sao(OFF→ON) |
0.1 mm 0.004" *2 |
||
Sar(ON → OFF) |
15 mm 0.59" *2 |
|||
Response time (ms) |
Lock→Unlock |
250 ms *3 |
||
Unlock→Lock | ||||
Detect→ Not detect |
20 ms + 2 ms × (number of cascaded unit -1) *3 |
|||
Not detect→ Detect |
300 ms + 25 ms × (number of cascaded unit -1) *3 |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
150 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
0.8 μF |
|||
Load wiring resistance |
Max. 2.5Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V(with a cable of 5 m 16.4') |
|||
External input (Short-circuit current) |
Safety input |
Approx. 1.5 mA × 2 |
||
Reset/EDM input |
Approx. 5 mA |
|||
Lock control input |
Approx. 2.5 mA |
|||
OSSD operation switching input |
Approx. 2.5 mA |
|||
Applicable Standards (Safety) |
EN61508, IEC61508(SIL3), EN ISO13849-1:2015(PL e, Category 4), |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10% or less, Class2) |
||
Power consumption |
5 W |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC60529) |
||
Operating ambient temperature |
-20 to 55°C -4 to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25 to 70°C -13 to 158°F(No freezing) *4 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis |
|||
Material |
Main unit |
PBT, PET/PAR, TPC, PC, Nickel-plated steel |
||
Actuator |
PBT, SUS304, Nickel-plated steel |
|||
Mounting bracket |
Aluminum (Plate and screw: Steel) |
|||
Weight |
Main unit |
Approx.250 g |
||
Actuator |
Approx.160 g 5.64 oz |
|||
*1 When the actuator is pulled first after unlocked, the holding force increases. | ||||
Scroll

Specifications
Model |
SZ-04M |
|||
Type |
Multi-function type |
|||
Detection |
Minimum detectable object size |
Diameter 30 mm 1.18"/40 mm 1.58", 50 mm 1.97", 70 mm 2.76", 150 mm 5.91" (depends on the setting) |
||
Detectable angle |
270° (-45° to 225°) |
|||
Response time |
General scan cycle (Scan cycle A) |
60 ms (2 scans) to 480 ms (16 scans) |
||
Specific scan cycle (Scan cycle B) |
66 ms (2 scans) to 528 ms (16 scans) |
|||
Response time |
General scan cycle (Scan cycle A) |
Response time of ON to OFF +125 ms |
||
Specific scan cycle (Scan cycle B) | ||||
Max. |
Minimum detectable object size: 70 mm 2.76"/150 mm 5.91" |
4.2 m 13.78' (-5° to 185°), 2.8 m 9.19' (-45° to -5°, 185° to 225°) |
||
Minimum detectable object size: 50 mm 1.97" |
3.0 m 9.84' (-5° to 185°), 2.0 m 6.56' (-45° to -5°, 185° to 225°) |
|||
Minimum detectable object size: 40 mm 1.58" |
2.4 m 7.87' (-5° to 185°), 1.6 m 5.25' (-45° to -5°, 185° to 225°) |
|||
Minimum detectable object size: 30 mm 1.18" |
1.8 m 5.91' (-5° to 185°), 1.2 m 3.94' (-45° to -5°, 185° to 225°) |
|||
Max. |
Minimum detectable object size: 70 mm 2.76"/150 mm 5.91" |
10.0 m 32.18' (-5° to 185°), 7.0 m 22.97' (-45° to -5°, 185° to 225°)*1 |
||
Minimum detectable object size: 50 mm 1.97" |
7.5 m 24.61' (-5° to 185°), 5.0 m 16.4' (-45° to -5°, 185° to 225°)*1 |
|||
Minimum detectable object size: 40 mm 1.58" |
6.0 m 19.69' (-5° to 185°), 4.0 m 13.12' (-45° to -5°, 185° to 225°)*1 |
|||
Minimum detectable object size: 30 mm 1.18" |
4.5 m 14.76' (-5° to 185°), 3.0 m 9.84' (-45° to -5°, 185° to 225°)*1 |
|||
Additional safety distance |
100 mm 3.94"*2 |
|||
Light source |
Type, wavelength |
Infrared laser diode, 905 nm |
||
Laser class |
Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10 *3) |
|||
OSSD output |
Output |
PNP or NPN (Selectable according to the connector cable) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF-state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 1 mA*5 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100Ω) |
|||
Load wiring resistance |
Max. 2.5Ω*6 |
|||
Input |
Input resistance |
4.4 kΩ (for Input 1, 3, 4, and 5) |
||
Non |
Output |
PNP/NPN totem pole output |
||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
Muting lamp |
(AUX6 output can be assigned for the |
Can be connected to the |
||
Cable length |
30 m 98.43' or less *7 |
|||
Approved |
EMC |
EMS |
IEC61496-1, EN61496-1, UL 61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL 61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR) |
|||
Rating |
Power voltage |
When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Power consumption |
Max. 9.5 W (without load) |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529)*8 |
||
Ambient light |
Incandescent lamp: 1,500 lux or less*9 |
|||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Operating relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
35 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum die casting, SPHC (Bottom) |
||
Window |
Polycarbonate |
|||
Weight |
Approx. 1.6 kg |
|||
*1 20% or more reflectance is necessary for the minimum detectable object in the warning zone. | ||||
Scroll

Specifications
Model |
SZ-V04 *1 |
|||
Type |
Multi-function Type |
|||
Detection capability |
Minimum detectable object size |
Diameter 20, 30, 40, 50, 70, 150 mm 0.79", 1.18", 1.57", 1.97", 2.76", 5.91" (depends on the setting) Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max. *2 |
||
Detectable angle |
190° ( -5° to 185° ) |
|||
Response time (ON to OFF) |
Standard Mode |
Scan Cycle A |
160 ms (2scans) to 1280 ms (16scans) *3 *4 |
|
Scan Cycle B |
168 ms (2scans) to 1344 ms (16scans) *3 *4 |
|||
Scan Cycle C |
176 ms (2scans) to 1408 ms (16scans) *3 *4 |
|||
High Speed Mode |
Scan Cycle A |
80 ms (2scans) to 640 ms (16scans) *3 *4 |
||
Scan Cycle B |
84 ms (2scans) to 672 ms (16scans) *3 *4 |
|||
Scan Cycle C |
88 ms (2scans) to 704 ms (16scans) *3 *4 |
|||
Response time (OFF to ON) |
Response time (ON to OFF) + 150 ms |
|||
Protection zone |
Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" |
8.4 m 27.56' (Standard Mode) 5.7 m 18.70' (High Speed Mode) |
||
Minimum detectable object size: 50 mm 1.97" |
5.6 m 18.37' (Standard Mode) 3.8 m 12.47' (High Speed Mode) |
|||
Minimum detectable object size: 40 mm 1.57" |
4.3 m 14.11' (Standard Mode) 2.9 m 9.51' (High Speed Mode) |
|||
Minimum detectable object size: 30 mm 1.18" |
2.9 m 9.51' (Standard Mode) 2.0 m 6.56' (High Speed Mode) |
|||
Minimum detectable object size: 20 mm 0.79" |
1.6 m 5.25' (Standard Mode) 1.1 m 3.61' (High Speed Mode) |
|||
Warning zone |
Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" |
26 m 85.30' (Standard Mode) 23 m 75.46' (High Speed Mode) *5 |
||
Minimum detectable object size: 50 mm 1.97" |
25 m 82.02' (Standard Mode) 21 m 68.90' (High Speed Mode) *5 |
|||
Minimum detectable object size: 40 mm 1.57" |
24 m 78.74' (Standard Mode) 20 m 65.62’ (High Speed Mode) *5 |
|||
Minimum detectable object size: 30 mm 1.18" |
23 m 75.46' (Standard Mode) 18 m 59.06' (High Speed Mode) *5 |
|||
Minimum detectable object size: 20 mm 0.79" |
21 m 68.90' (Standard Mode) 15 m 49.21' (High Speed Mode) *5 |
|||
Additional safety distance |
100 mm 3.94" *6 |
|||
Maximum measurement distance |
60 m 196.85' *7 |
|||
Maximum number of banks |
Max. 4 banks |
|||
Multiple scanner heads |
Max. 3 scanner heads |
|||
Camera monitoring area |
Monitor area: over 190° (-5° to 185°) *8 |
|||
Display |
QVGA 2.2inch color LCD |
|||
Light source |
Type, wavelength |
Infrared laser diode, 905 nm |
||
Laser Class |
IEC |
Class1 IEC/EN60825-1 |
||
FDA |
Class1 FDA 21CFR 1040.10, 1040.11 (Laser Notice) *9 |
|||
JIS |
Class1 JIS C6802 |
|||
Control output (OSSD) |
Output |
Transistor outputs (NPN or PNP is selected in the software) |
||
Number of outputs |
4 outputs |
|||
Max. load current |
500 mA *10 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF-state voltage |
Max. 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 1 mA *11 |
|||
Max. capacitive load |
2.2 μF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Inputs |
PNP |
ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) |
||
NPN |
ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM) |
|||
Non-safety related output (AUX output) |
Output type |
Transistor outputs (NPN or PNP is selected by the dedicated PC software) |
||
Number of outputs |
6 outputs |
|||
Max. load current |
Max. 50 mA |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 5 m 16.40') |
|||
Muting lamp |
Incandescent lamp (24 VDC, 1 to 5.5 W) or LED lamp (load current: 10 to 230 mA) can be connected |
|||
Interface |
USB |
USB2.0 |
||
Ethernet |
Standard |
- |
||
Transmission rate | ||||
Cable | ||||
Connector | ||||
Network function | ||||
Cable length |
Power and I/O cable |
30 m 98.43' or less *12 |
||
Between scanner head and display unitc |
20 m 65.62' or less each *13 |
|||
Ethernet cable |
- |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE) |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR), IEC61508, EN61508, |
|||
Rating |
Power consumption |
11.8 W (without load), 55.0 W (with load) *14 |
||
Power voltage |
24 VDC ±10% (Ripple P-P 10% or less): When using a converter power supply, 24 VDC +20%/-30%: When using a battery |
|||
Environmental resistance |
Enclosure rating |
IP65(IEC60529) |
||
Ambient light |
Incandescent lamp: 1500 lux or less *15 |
|||
Operating ambient temperature |
-10 to +50°C 14 to 122°F (No freezing) |
|||
Operating relative humidity |
35% to 85% RH (No condensation) |
|||
Storage temperature |
-25 to +60°C -13 to +140°F (No freezing) |
|||
Storage relative humidity |
35% to 95% RH |
|||
Vibration resistance |
10 to 55 Hz, 0.7 mm 0.03" compound amplitude, 20 sweeps each in X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 328.08 ft/s2 (Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1000 times each axis |
|||
Material |
Scanner head |
Main unit case |
Magnesium |
|
Window |
Polycarbonate, PEI |
|||
Indicator part |
Aluminum, PES |
|||
Display unit |
Case |
Magnesium, PPS, Polycarbonate |
||
System memory |
Aluminum, PPE |
|||
Weight |
Approx. 2100 g |
|||
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). | ||||
Scroll

Specifications
Model |
GS-71PC |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GL-R1UB |
|||
Type |
Interface Unit |
|||
Overview |
Optional accessory that is necessary for performing GL-R settings and monitoring with a PC. |
|||
Applicable product |
GL-R Series |
|||
Number included |
1 unit |
|||
Material |
Polycarbonate |
|||
Note |
The USB cable to use in connecting the interface unit and a PC is not included. Use an A to miniB type USB cable (sold separately). |
|||
Weight |
Approx. 10 g |
|||
Scroll

Specifications
Model |
GL-R52H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Total length |
40.94" 1040mm |
|||
No. of beam |
52 |
|||
Detection height |
40.16" 1020mm |
|||
Protection height |
41.93" 1065mm |
|||
Beam axis spacing/Lens diameter |
20 mm / ø5 0.79" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
10 |
|
OFF→ON |
53.9*2 |
|||
All blocked→ON |
77*3 |
|||
Optical synchronization system |
ON→OFF |
14.3 |
||
OFF→ON |
60.3*2 |
|||
All blocked→ON |
94.2*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
69 |
||
Receiver |
80 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1440 g |
||
Receiver |
1450 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||
Scroll

Specifications
Model |
SL-U2 |
|||
System |
Switching type |
|||
Input power supply voltage |
100 to 240 VAC ±10 % (50/60 Hz) |
|||
Ripple/noise |
240 mV p-p or less |
|||
Output capacity |
1.8 A |
|||
Supply voltage interruption |
10 ms max. |
|||
Approved standards |
EMC |
EMI |
EN61000-6-2, EN55011 Class A, FCC Part15 Class A |
|
Safety |
EN62368-1, EN62477-1, UL 60950-1, CSA 60950-1 |
|||
Rating |
Power voltage |
24 VDC ±10 %, Class 2 |
||
Power consumption |
135 VA |
|||
Environmental resistance |
Pollution degree |
2 |
||
Overvoltage category |
II |
|||
Insulation resistance |
At least 50 MΩ (500 VDC mega, between all external terminals and case) |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,500 VAC, 1 min. (between all external terminals and case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 240 g |
|||
Scroll

Specifications
Model |
GS-71P10 |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 770 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-71N5 |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 100 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 560 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-71N10 |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 100 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 770 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-53PCSO(3196) |
|||
Lock type |
Power-to-release type |
|||
Type |
Advanced function type |
|||
Response time |
Lock |
Lock→Unlock |
220 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
2 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
Approx. 10 mA × 1 |
|||
Lock control input |
Approx. 2.5 mA × 2 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll

Specifications
Model |
GS-53PC |
|||
Lock type |
Power-to-release type |
|||
Type |
Advanced function type |
|||
Response time |
Lock |
Lock→Unlock |
220 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
2 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
Approx. 10 mA × 1 |
|||
Lock control input |
Approx. 2.5 mA × 2 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||
Scroll