Filters

Process Controls / Process Sensors

586 products

Showing 577 - 586 of 586 products

Showing 577 - 586 of 586 products
View
keyence Stock Image
Keyence FD-HCB10G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

FD-HCB10G

Cable end

M12, 8-pin female - 6-core cable

Length

10 m 32.8'

Material

PVC

Weight

Approx. 420 g

keyence Stock Image
Keyence FD-HB1 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

FD-HB1

Material

SUS304

Weight

Approx. 65 g 2.29 oz

Keyence Stock Image
Keyence FD-XA2 Keyence
Sale price 7,541.00 kr
Only 5 units left

Specifications

Model

FD-XA2

Type

DIN rail type, expansion unit

Display method

Output indicator, 4-digit 7 segment display, OLED, Stability level display

Display refresh frequency

Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second

Response time

50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms)

Integration data storage interval

Written to the memory every 10 seconds

Memory back up

EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more) *1

Detection mode

ch.1

Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable)

ch.2

Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable)

Input/output

Output

NPN/PNP setting switch
Open collector output: 30 V or lower, main unit: 50 mA or lower/ch.*2/expansion unit: 20 mA or lower/ch., residual voltage: 2 V or lower

Analog output

-

External input

Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable)
Short circuit current: NPN 1 mA or lower/PNP 2 mA or lower, input time: 20 ms or longer

Network support

Supports NU series

Unit expansion

Up to 7*3 per main unit

Protection circuit

Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection

Power supply

Power voltage

20 to 30 VDC including 10 % ripple (P-P) , Class 2

Power consumption

185 mA or lower (including the sensor head, excluding the load current)

Environmental resistance

Ambient temperature

-10 to +50 °C (No freezing) 14 to 122 °F

Relative humidity

35 % to 85 %RH (No condensation)

Vibration resistance

10 - 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

Shock resistance

100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction

Material

Main body case/front sheet: PC, Key top: POM, Cable: PVC

Weight

Approx. 180 g

*1 Internal data from full time recording can be read via USB (Ver.2.0) communication.
*2 20 mA or lower/ch when adding expansion units.
*3 Refer to the Instruction Manual for the number of connected units to N-bus devices.

Keyence Stock Image
Keyence OP-26751 Keyence
Sale price 1,122.00 kr
Only 9 units left

Specifications

Model

OP-26751

Type

End unit

Overview

Used to secure the amplifier when main and expansion units are additionally set.

Applicable product

Expansion type sensor amplifier including FS-N10 Series.

Number included

2 pcs.

Material

Polycarbonate, stainless steel, Screw: Steel (Nickel plated)

Note

When adding sensor amplifier, use DIN rail and surely use end unit at both ends.

Keyence New Stock Image
Keyence MU-N12 Keyence
Sale price 3,860.00 kr
Only 5 units left

Specifications

Model

MU-N12

Main unit/Expansion unit

Expansion unit

Response time

Depends on the connected sensor model*1

Expansion units

Up to 4 expansion units*2

I/O

Control output

4 max.,
NPN open collector/PNP open collector selectable,
24 V or less,
Main unit: 50 mA or less*3,
Expansion unit: 20 mA or less,
Residual voltage: 2 V or less,
N.O./N.C. selectable
*1*4

External input

5 max.,
Short-circuit current: NPN: 1 mA or less,
PNP: 2 mA or less,
For the applied voltage, see wiring diagrams
(page 3 of the instruction manual)
*1*4

Analog output

-

Protection circuit

Protection against reverse power connection,
power supply surge, output overcurrent,
output surge, and reverse output connection

Power supply

Power voltage

24 VDC, ripple (P-P) 10% or less, Class 2 or LPS

Current consumption

55 mA or less (without load)*5

Sensor
connection
specification

Allowable sensor current

150 mA or less

N-bus
connection
specification

Allowable passing
current

900 mA or less

Environmental resistance

Ambient temperature

-20 to +50 °C -4 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case and dust cover: Polycarbonate
Buttons: Polyacetal
Display panel: PMMA

Weight

Approx. 70 g

*1 The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model.
For details, see the specific "MU-N Series User's Manual" for the model that will be connected.
*2 Up to 5 N-bus devices, including the main unit (or network unit), can be linked together.
*3 20 mA or less: When using the expansion unit.
*4 For more information on Control output, External input, and Analog output wire allocation, please refer to the table of "Power Cable Pin Layout" on page 3 of this manual.
*5 1185 mA or less when a sensor is attached, 4 outputs (with loads) are used, and expansion units are connected.

Keyence New Stock Image
Keyence MU-N11 Keyence
Sale price 3,816.00 kr
Only 6 units left

Specifications

Model

MU-N11

Main unit/Expansion unit

Main unit

Response time

Depends on the connected sensor model*1

Expansion units

Up to 4 expansion units*2

I/O

Control output

4 max.,
NPN open collector/PNP open collector selectable,
24 V or less,
Main unit: 50 mA or less*3,
Expansion unit: 20 mA or less,
Residual voltage: 2 V or less,
N.O./N.C. selectable
*1*4

External input

5 max.,
Short-circuit current: NPN: 1 mA or less,
PNP: 2 mA or less,
For the applied voltage, see wiring diagrams
(page 3 of the instruction manual)
*1*4

Analog output

1 max.,
Current output/ Voltage output selectable,
Current output: 4 to 20 mA,
Max. load resistance: 450 Ω,
Voltage output: 0 to 10 V,
External load resistance: 5 kΩ or more
*1*4

Protection circuit

Protection against reverse power connection,
power supply surge, output overcurrent,
output surge, and reverse output connection

Power supply

Power voltage

24 VDC, ripple (P-P) 10% or less, Class 2 or LPS

Current consumption

70 mA or less (without load)*5

Sensor
connection
specification

Allowable sensor current

150 mA or less

N-bus
connection
specification

Allowable passing
current

1200 mA or less

Environmental resistance

Ambient temperature

-20 to +50 °C -4 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case and dust cover: Polycarbonate
Buttons: Polyacetal
Display panel: PMMA

Weight

Approx. 70 g

*1 The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model.
For details, see the specific "MU-N Series User's Manual" for the model that will be connected.
*2 Up to 5 N-bus devices, including the main unit (or network unit), can be linked together.
*3 20 mA or less: When using the expansion unit.
*4 For more information on Control output, External input, and Analog output wire allocation, please refer to the table of "Power Cable Pin Layout" on page 3 of this manual.
*5 1500 mA or less when a sensor is attached, 4 outputs (with loads) are used, and expansion units are connected.

Keyence New Stock Image
Keyence FD-XS1E Keyence
Sale price 22,292.00 kr
Only 5 units left

Specifications

Model

FD-XS1E

Supported pipe materials

Metal pipes, Plastic pipes (soft/hard) *1

Supported fluids

Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1

Supported fluid temperature

0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)

Clamp set model

Plastic pipe/tube attachment

FD-XC1R1, FD-XC1R2

Metal pipe attachment

FD-XC1M*2

Maximum rated flow rate

1000 mL/min

Zero cut flow rate

50 mL/min*3 (variable, default)

Display resolution

Instantaneous flow rate

1/10 mL/min (Displayed on controller)

Repeatability

Response time 50 ms: ±20 % of RD
Response time 500 ms: ±15 % of RD

Hysteresis

Variable

Display method

Status indicator

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529) , IP68G (JIS C0920) *4

Ambient temperature

0 to 60 °C 32 to 140 °F (No freezing)

Relative humidity

35 % to 85 %RH (No condensation)

Vibration resistance

10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

Shock resistance

50 G 11 ms 3 times each for X,Y,Z direction

Material

Sensor head

Head body: PPS/PPSU, relay amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM

Clamp set

For plastic pipe

Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7

For metal pipe

Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7

Weight

Approx. 230 g

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
*2 When using stainless steel or iron pipes, the ideal pipe wall thickness is as follows, FD-XS1E: approx. 0.5 mm 0.02", FD-XS8E: approx. 1 mm 0.04", FD-XS20E: approx. 1 0.04" to 2 mm 0.08". FD-X signal strength and stability will decrease as the thickness of the pipe wall increases or decreases from the suggested size.
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 The connector part of the sensor head cable is IP65/IP67.

Keyence New Stock Image
Keyence FD-Q20C Keyence
Sale price 4,853.00 kr
In stock, 11 units

Specifications

Model

FD-Q20C

Supported pipe diameter

1/2" (15 A), ø18 to ø23 (mm)
3/4" (20 A), ø23 to ø28 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1/2" (15 A): 60 L/min, 15.9 G/min
3/4" (20 A): 100 L/min, 26.4 G/min

Zero cut flow rate

2.5 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.1/ 1 (Default : 0.1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

100 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/SUSXM7

Weight

Approx. 400 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

FS-MC8P Keyence
Keyence FS-MC8P Keyence
Sale price 2,946.00 kr
In stock, 54 units

Specifications

Model

FS-MC8P

Output

PNP

Response time

Depends on the response time settings of the connected expansion units

External input

Input time of the connected expansion units +11 ms

Number of inputs and outputs

Separate control outputs: 8, common output: 1, common input: 1

Unit expansion

Up to 8 expansion units can be connected. (However, each dual output type will be treated as 2 expansion units.) Allowable passing current: 1200 mA or less

Indicators

STATUS indicator (green and red two-color display) MEMORY indicator (orange) LOCK indicator (orange)

Separate control output,
common output

PNP open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.6 V or less

Protection circuit

Protection against reverse power connection, reverse output connection, output overcurrent, and output surge

Power supply

Power voltage

10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*1

Power consumption

690 mW or less (when used as a solitary unit) (26 mA or less at 24 V/38 mA or less at 12 V [excluding the load current] )*2

Environmental resistance

Ambient temperature

-20 °C -4 °F to +55 °C +131 °F (no freezing)

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Shock resistance

500 m/s2; 3 times each for X, Y, and Z axes

Case material

Main unit and cover: polycarbonate

Weight

Approx. 110 g

*1 Match the rated power supply voltage of the expansion units to be connected to the system.
*2 The power consumption including the load when the maximum number of units are connected is 38 W max.

FS-MC8N Keyence
Keyence FS-MC8N Keyence
Sale price 2,477.00 kr
In stock, 45 units

Specifications

Model

FS-MC8N

Output

NPN

Response time

Depends on the response time settings of the connected expansion units

External input

Input time of the connected expansion units +11 ms

Number of inputs and outputs

Separate control outputs: 8, common output: 1, common input: 1

Unit expansion

Up to 8 expansion units can be connected. (However, each dual output type will be treated as 2 expansion units.) Allowable passing current: 1200 mA or less

Indicators

STATUS indicator (green and red two-color display) MEMORY indicator (orange) LOCK indicator (orange)

Separate control output,
common output

NPN open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.4 V or less

Protection circuit

Protection against reverse power connection, reverse output connection, output overcurrent, and output surge

Power supply

Power voltage

10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*1

Power consumption

690 mW or less (when used as a solitary unit) (26 mA or less at 24 V/38 mA or less at 12 V [excluding the load current] )*2

Environmental resistance

Ambient temperature

-20 °C -4 °F to +55 °C +131 °F (no freezing)

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Shock resistance

500 m/s2; 3 times each for X, Y, and Z axes

Case material

Main unit and cover: polycarbonate

Weight

Approx. 110 g

*1 Match the rated power supply voltage of the expansion units to be connected to the system.
*2 The power consumption including the load when the maximum number of units are connected is 38 W max.

Recently viewed