Process Controls / Process Sensors
586 products
Showing 577 - 586 of 586 products

Specifications
Model |
FD-HCB10G |
|||
Cable end |
M12, 8-pin female - 6-core cable |
|||
Length |
10 m 32.8' |
|||
Material |
PVC |
|||
Weight |
Approx. 420 g |
|||
Scroll

Specifications
Model |
FD-XA2 |
|||
Type |
DIN rail type, expansion unit |
|||
Display method |
Output indicator, 4-digit 7 segment display, OLED, Stability level display |
|||
Display refresh frequency |
Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second |
|||
Response time |
50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms) |
|||
Integration data storage interval |
Written to the memory every 10 seconds |
|||
Memory back up |
EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more) *1 |
|||
Detection mode |
ch.1 |
Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable) |
||
ch.2 |
Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable) |
|||
Input/output |
Output |
NPN/PNP setting switch |
||
Analog output |
- |
|||
External input |
Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable) |
|||
Network support |
Supports NU series |
|||
Unit expansion |
Up to 7*3 per main unit |
|||
Protection circuit |
Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10 % ripple (P-P) , Class 2 |
||
Power consumption |
185 mA or lower (including the sensor head, excluding the load current) |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C (No freezing) 14 to 122 °F |
||
Relative humidity |
35 % to 85 %RH (No condensation) |
|||
Vibration resistance |
10 - 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction |
|||
Shock resistance |
100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction |
|||
Material |
Main body case/front sheet: PC, Key top: POM, Cable: PVC |
|||
Weight |
Approx. 180 g |
|||
*1 Internal data from full time recording can be read via USB (Ver.2.0) communication. | ||||
Scroll

Specifications
Model |
OP-26751 |
|||
Type |
End unit |
|||
Overview |
Used to secure the amplifier when main and expansion units are additionally set. |
|||
Applicable product |
Expansion type sensor amplifier including FS-N10 Series. |
|||
Number included |
2 pcs. |
|||
Material |
Polycarbonate, stainless steel, Screw: Steel (Nickel plated) |
|||
Note |
When adding sensor amplifier, use DIN rail and surely use end unit at both ends. |
|||
Scroll

Specifications
Model |
MU-N12 |
|||
Main unit/Expansion unit |
Expansion unit |
|||
Response time |
Depends on the connected sensor model*1 |
|||
Expansion units |
Up to 4 expansion units*2 |
|||
I/O |
Control output |
4 max., |
||
External input |
5 max., |
|||
Analog output |
- |
|||
Protection circuit |
Protection against reverse power connection, |
|||
Power supply |
Power voltage |
24 VDC, ripple (P-P) 10% or less, Class 2 or LPS |
||
Current consumption |
55 mA or less (without load)*5 |
|||
Sensor |
Allowable sensor current |
150 mA or less |
||
N-bus |
Allowable passing |
900 mA or less |
||
Environmental resistance |
Ambient temperature |
-20 to +50 °C -4 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case and dust cover: Polycarbonate |
|||
Weight |
Approx. 70 g |
|||
*1 The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model. | ||||
Scroll

Specifications
Model |
MU-N11 |
|||
Main unit/Expansion unit |
Main unit |
|||
Response time |
Depends on the connected sensor model*1 |
|||
Expansion units |
Up to 4 expansion units*2 |
|||
I/O |
Control output |
4 max., |
||
External input |
5 max., |
|||
Analog output |
1 max., |
|||
Protection circuit |
Protection against reverse power connection, |
|||
Power supply |
Power voltage |
24 VDC, ripple (P-P) 10% or less, Class 2 or LPS |
||
Current consumption |
70 mA or less (without load)*5 |
|||
Sensor |
Allowable sensor current |
150 mA or less |
||
N-bus |
Allowable passing |
1200 mA or less |
||
Environmental resistance |
Ambient temperature |
-20 to +50 °C -4 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case and dust cover: Polycarbonate |
|||
Weight |
Approx. 70 g |
|||
*1 The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model. | ||||
Scroll

Specifications
Model |
FD-XS1E |
|||
Supported pipe materials |
Metal pipes, Plastic pipes (soft/hard) *1 |
|||
Supported fluids |
Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1 |
|||
Supported fluid temperature |
0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature) |
|||
Clamp set model |
Plastic pipe/tube attachment |
FD-XC1R1, FD-XC1R2 |
||
Metal pipe attachment |
FD-XC1M*2 |
|||
Maximum rated flow rate |
1000 mL/min |
|||
Zero cut flow rate |
50 mL/min*3 (variable, default) |
|||
Display resolution |
Instantaneous flow rate |
1/10 mL/min (Displayed on controller) |
||
Repeatability |
Response time 50 ms: ±20 % of RD |
|||
Hysteresis |
Variable |
|||
Display method |
Status indicator |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) , IP68G (JIS C0920) *4 |
||
Ambient temperature |
0 to 60 °C 32 to 140 °F (No freezing) |
|||
Relative humidity |
35 % to 85 %RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction |
|||
Shock resistance |
50 G 11 ms 3 times each for X,Y,Z direction |
|||
Material |
Sensor head |
Head body: PPS/PPSU, relay amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM |
||
Clamp set |
For plastic pipe |
Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7 |
||
For metal pipe |
Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7 |
|||
Weight |
Approx. 230 g |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe. | ||||
Scroll

Specifications
Model |
FD-Q20C |
|||
Supported pipe diameter |
1/2" (15 A), ø18 to ø23 (mm) |
|||
Supported pipe materials |
Metal pipe/Resin pipe*1 |
|||
Supported fluids |
Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 |
|||
Supported fluid temperature |
0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2 |
|||
Maximum rated flow |
1/2" (15 A): 60 L/min, 15.9 G/min |
|||
Zero cut flow rate |
2.5 L/min (Default)*3 |
|||
Display method |
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
0.1/ 1 (Default : 0.1) (L/min) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, |
|||
Repeatability |
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time)) |
|||
Hysteresis |
Variable |
|||
Integrated flow unit display |
0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L) |
|||
Integrated flow data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) |
|||
Power I/O connector |
M12 4-pin connector |
|||
Input/Output (Selectable) |
Output (ch.1/ch.2) |
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), |
||
Analog output (ch.2) |
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5 |
|||
External input (ch.2) |
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), |
|||
Power supply |
Power voltage |
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
||
Current consumption |
100 mA or less (Load current excluded)*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Sensor main unit |
PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
||
Sensor surface |
Rubber |
|||
Mounting bracket |
SUS304/PA/SUSXM7 |
|||
Weight |
Approx. 400 g (including mounting bracket) |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) | ||||
Scroll

Specifications
Model |
FS-MC8P |
|||
Output |
PNP |
|||
Response time |
Depends on the response time settings of the connected expansion units |
|||
External input |
Input time of the connected expansion units +11 ms |
|||
Number of inputs and outputs |
Separate control outputs: 8, common output: 1, common input: 1 |
|||
Unit expansion |
Up to 8 expansion units can be connected. (However, each dual output type will be treated as 2 expansion units.) Allowable passing current: 1200 mA or less |
|||
Indicators |
STATUS indicator (green and red two-color display) MEMORY indicator (orange) LOCK indicator (orange) |
|||
Separate control output, |
PNP open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.6 V or less |
|||
Protection circuit |
Protection against reverse power connection, reverse output connection, output overcurrent, and output surge |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*1 |
||
Power consumption |
690 mW or less (when used as a solitary unit) (26 mA or less at 24 V/38 mA or less at 12 V [excluding the load current] )*2 |
|||
Environmental resistance |
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing) |
||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 110 g |
|||
*1 Match the rated power supply voltage of the expansion units to be connected to the system. | ||||
Scroll

Specifications
Model |
FS-MC8N |
|||
Output |
NPN |
|||
Response time |
Depends on the response time settings of the connected expansion units |
|||
External input |
Input time of the connected expansion units +11 ms |
|||
Number of inputs and outputs |
Separate control outputs: 8, common output: 1, common input: 1 |
|||
Unit expansion |
Up to 8 expansion units can be connected. (However, each dual output type will be treated as 2 expansion units.) Allowable passing current: 1200 mA or less |
|||
Indicators |
STATUS indicator (green and red two-color display) MEMORY indicator (orange) LOCK indicator (orange) |
|||
Separate control output, |
NPN open-collector, 30 V or less, 20 mA or less per output, residual voltage: 1.4 V or less |
|||
Protection circuit |
Protection against reverse power connection, reverse output connection, output overcurrent, and output surge |
|||
Power supply |
Power voltage |
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*1 |
||
Power consumption |
690 mW or less (when used as a solitary unit) (26 mA or less at 24 V/38 mA or less at 12 V [excluding the load current] )*2 |
|||
Environmental resistance |
Ambient temperature |
-20 °C -4 °F to +55 °C +131 °F (no freezing) |
||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
500 m/s2; 3 times each for X, Y, and Z axes |
|||
Case material |
Main unit and cover: polycarbonate |
|||
Weight |
Approx. 110 g |
|||
*1 Match the rated power supply voltage of the expansion units to be connected to the system. | ||||
Scroll