Process Controls / Process Sensors
586 products
Showing 1 - 24 of 586 products

Specifications
Model |
FD-Q32C |
|||
Supported pipe diameter |
1" (25 A), ø28 to ø37 (mm) |
|||
Supported pipe materials |
Metal pipe/Resin pipe*1 |
|||
Supported fluids |
Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 |
|||
Supported fluid temperature |
0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2 |
|||
Maximum rated flow |
1" (25 A): 200 L/min, 52.8 G/min |
|||
Zero cut flow rate |
5 L/min (Default)*3 |
|||
Display method |
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
0.1/ 1 (Default :1) (L/min) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, |
|||
Repeatability |
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time)) |
|||
Hysteresis |
Variable |
|||
Integrated flow unit display |
1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) |
|||
Integrated flow data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) |
|||
Power I/O connector |
M12 4-pin connector |
|||
Input/Output (Selectable) |
Output (ch.1/ch.2) |
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), |
||
Analog output (ch.2) |
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5 |
|||
External input (ch.2) |
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), |
|||
Power supply |
Power voltage |
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
||
Current consumption |
130 mA or less (Load current excluded)*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Sensor main unit |
PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
||
Sensor surface |
Rubber |
|||
Mounting bracket |
SUS304/PA/POM/SUSXM7 |
|||
Weight |
Approx. 530 g (including mounting bracket) |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) | ||||
Scroll

Specifications
Model |
FD-XA1 |
|||
Type |
DIN rail type, main unit |
|||
Display method |
Output indicator, 4-digit 7 segment display, OLED, Stability level display |
|||
Display refresh frequency |
Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second |
|||
Response time |
50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms) |
|||
Integration data storage interval |
Written to the memory every 10 seconds |
|||
Memory back up |
EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more) *1 |
|||
Detection mode |
ch.1 |
Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable) |
||
ch.2 |
Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable) |
|||
Input/output |
Output |
NPN/PNP setting switch |
||
Analog output |
4-20 mA/0-20 mA (selectable) load resistance: 500 ohms or lower |
|||
External input |
Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable) |
|||
Network support |
IO-Link*3 |
|||
Unit expansion |
Up to 7*4 per main unit |
|||
Protection circuit |
Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10 % ripple (P-P) , Class 2 |
||
Power consumption |
195 mA or lower (including the sensor head, excluding the load current) |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C (No freezing) 14 to 122 °F |
||
Relative humidity |
35 % to 85 %RH (No condensation) |
|||
Vibration resistance |
10 - 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction |
|||
Shock resistance |
100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction |
|||
Material |
Main body case/front sheet: PC, Key top: POM, Cable: PVC |
|||
Weight |
Approx. 210 g |
|||
*1 Internal data from full time recording can be read via USB (Ver.2.0) communication. | ||||
Scroll

Specifications
Model |
FD-Q10C |
|||
Supported pipe diameter |
1/4" (8 A), ø13 to ø16 (mm) |
|||
Supported pipe materials |
Metal pipe/Resin pipe*1 |
|||
Supported fluids |
Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 |
|||
Supported fluid temperature |
0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2 |
|||
Maximum rated flow |
1/4" (8 A): 20 L/min, 5.2 G/min |
|||
Zero cut flow rate |
1.0 L/min (Default)*3 |
|||
Display method |
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
0.01/0.1/1 (Default : 0.1) (L/min) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, |
|||
Repeatability |
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time)) |
|||
Hysteresis |
Variable |
|||
Integrated flow unit display |
0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L) |
|||
Integrated flow data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) |
|||
Power I/O connector |
M12 4-pin connector |
|||
Input/Output (Selectable) |
Output (ch.1/ch.2) |
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), |
||
Analog output (ch.2) |
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5 |
|||
External input (ch.2) |
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), |
|||
Power supply |
Power voltage |
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
||
Current consumption |
100 mA or less (Load current excluded)*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Sensor main unit |
PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
||
Sensor surface |
Rubber |
|||
Mounting bracket |
SUS304/PA/SUSXM7 |
|||
Weight |
Approx. 340 g (including mounting bracket) |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) | ||||
Scroll

Specifications
Model |
FT-H20 |
|||
Type |
Mid to low temperature, Mid-range |
|||
Rated temperature range |
32 to 932°F (0 to 500°C) *1 |
|||
Displayable temperature range |
-58 to +968°F (-50 to +520°C) |
|||
Detecting distance |
Unlimited *2 |
|||
Measuring distance / |
60/ø8.5 mm 2.36"/ø0.33" |
|||
Sight |
2-point visible laser beam *3 |
|||
Detecting element |
Thermopile |
|||
Detecting wavelength |
8 to 14 μm |
|||
Repeatability |
±0.9°F (±0.5°C) |
|||
Emissivity (ε) correction |
0.10 to 1.99 (0.01 step) |
|||
Environmental resistance |
Ambient temperature |
14 to 131°F (-10 to 55°C), No freezing |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions |
|||
Shock resistance |
500 m/s2, 10 times in each direction of each axis (X, Y, Z), 60 times in total |
|||
Material |
Case: Reinforced glass plastic, |
|||
Accessory |
Mounting bracket |
|||
Weight |
Approx. 120g |
|||
*1 Repeatability is guaranteed within the rated temperature range. | ||||
Scroll

Specifications
Model |
FW-H10R |
|||
Type |
Long range |
|||
Detecting area |
150 to 1000 mm 5.9" to 39.4"*1 |
|||
Response speed |
1,000 ms |
|||
Temperature characteristics |
0.06% of F.S./°C*2 |
|||
Indicator lamp |
Operation indicator (orange) x1 (Turns on when the target is within the detecting range.) |
|||
Dimensions |
M18 x P1, Length= 104 mm 4.09" |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +70 °C -13 to 158 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Brass-nickel plating, PBT, Polyurethane, Polyamide resin |
|||
Accessories |
M18 nut: 2, Head cable: 2 m 6.6', Standard Mounting Bracket (FW-B01) |
|||
Weight |
Approx. 106 g |
|||
*1 Less stable zones of approx. 2% of F.S. exist at both ends of the detecting range. | ||||
Scroll

Specifications
Model |
FD-G50 |
|||
Pipe size |
DN (Diameter Nominal) |
32 A, 40 A, 50 A |
||
NPS (Nominal Pipe Size) |
1 1/4", 1 1/2", 2" |
|||
Outer diameter of pipe |
ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44" |
|||
Pipe thickness |
2.4 to 5.7 mm 0.09" to 0.22" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||
Rated velocity of flow range |
Up to 15 m/s |
|||
Actual flow rate range (typical) |
m3/h |
Pipe size 32 A: 54.00 |
||
L/min |
Pipe size 32 A: 900.0 |
|||
CFM |
Pipe size 32 A: 32.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 32 A: 151.58 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 32 A: 192.17 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 32 A: 232.76 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 32 A: 273.35 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
Instantaneous flow rate |
0.01 m3/h, 0.1 L/min, 0.01 CFM |
||
Consumption/leakage amount |
0.01 m3, 1 L, 0.1 CF |
|||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||
Zero point error |
±0.15% of F.S.*2*6 |
|||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||
Hysteresis |
Variable |
|||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||
I/O wiring connection port |
M12 4-pin connector (male) |
|||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||
Communication interface |
USB |
USB 2.0 |
||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||
Connector |
M12 connector (female, D-code) |
|||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||
Events |
100 |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||
Relative humidity |
5 to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||
Mounting/damping bracket |
SUS304 |
|||
Weight |
Approx. 2.7 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. | ||||
Scroll

Specifications
Model |
FD-XC8R3 |
|||
Supported diameter |
Outer diameter of pipe: ø 8 0.31 " |
|||
Weight |
Approx. 60 g |
|||
Scroll

Specifications
Model |
FD-Q50C |
|||
Supported pipe diameter |
1 1/2" (40 A), ø44 to ø52 (mm) |
|||
Supported pipe materials |
Metal pipe/Resin pipe*1 |
|||
Supported fluids |
Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 |
|||
Supported fluid temperature |
0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2 |
|||
Maximum rated flow |
1 1/2" (40 A): 400 L/min, 105.7 G/min |
|||
Zero cut flow rate |
25 L/min (Default)*3 |
|||
Display method |
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
0.1/ 1 (Default :1) (L/min) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, |
|||
Repeatability |
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time)) |
|||
Hysteresis |
Variable |
|||
Integrated flow unit display |
1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) |
|||
Integrated flow data storage cycle |
Save to memory every 10 seconds |
|||
Memory backup |
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) |
|||
Power I/O connector |
M12 4-pin connector |
|||
Input/Output (Selectable) |
Output (ch.1/ch.2) |
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), |
||
Analog output (ch.2) |
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5 |
|||
External input (ch.2) |
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), |
|||
Power supply |
Power voltage |
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
||
Current consumption |
130 mA or less (Load current excluded)*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Sensor main unit |
PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
||
Sensor surface |
Rubber |
|||
Mounting bracket |
SUS304/PA/POM/SUSXM7 |
|||
Weight |
Approx. 640 g (including mounting bracket) |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) | ||||
Scroll

Specifications
Model |
OP-88076 |
|||
Overview |
This is a relay connector cable with M12 on both ends. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M12 connector sensor |
|||
Cable end |
M12 straight connector - M12 straight connector |
|||
Length |
5 m 16.40' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 170 g 6.00 oz |
|||
Scroll

Specifications
Model |
OP-88075 |
|||
Overview |
This is a relay connector cable with M12 on both ends. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M12 connector sensor |
|||
Cable end |
M12 straight connector - M12 straight connector |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 80 g 2.82 oz |
|||
Scroll

Specifications
Model |
OP-88072 |
|||
Type |
Cable for Separate Amplifier Models: For Amplifier (Connector Type) |
|||
Overview |
This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M8 connector sensor |
|||
Cable end |
M8 - M12 straight |
|||
Length |
5 m 16.4' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 130 g 4.58 oz |
|||
Scroll

Specifications
Model |
OP-88071 |
|||
Type |
Cable for Separate Amplifier Models: For Amplifier (Connector Type) |
|||
Overview |
This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M8 connector sensor |
|||
Cable end |
M8 - M12 straight |
|||
Length |
2 m 6.6' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 70 g 2.46 oz |
|||
Scroll


Specifications
Model |
OP-87626 |
|||
Type |
Connector Cable M8 Straight 10m Standard |
|||
Cable end |
M8 4-pin Straight |
|||
Length |
10 m 32.8' |
|||
Material |
Cable: PVC, |
|||
Weight |
Approx. 260 g |
|||
Scroll

Specifications
Model |
OP-87625 |
|||
Length |
2 m 6.6' |
|||
Material |
Cable: PVC |
|||
Weight |
Approx. 70 g |
|||
Scroll

Specifications
Model |
OP-85504 |
|||
Overview |
Connector cable with M12 on the both edges for connection. |
|||
Applicable product |
M12 connector sensor |
|||
Cable end |
M12 straight - M12 straight |
|||
Length |
5 m 16.40' |
|||
Material |
Cable: Polyvinyl chloride (PVC) |
|||
Weight |
Approx. 130 g 4.58 oz |
|||
Scroll

Specifications
Model |
FD-HCC2 |
|||
Cable end |
M12, 8-pin female to M12, 4-pin male |
|||
Length |
2 m 6.6' |
|||
Material |
PVC |
|||
Weight |
Approx. 120 g |
|||
Scroll

Specifications
Model |
FD-HCC0 |
|||
Cable end |
M12, 8-pin female to M12, 4-pin male |
|||
Weight |
Approx. 20 g |
|||
Scroll

Specifications
Model |
FD-HCB2 |
|||
Cable end |
M12, 8-pin female - 6-core cable |
|||
Length |
2 m 6.6' |
|||
Material |
PVC |
|||
Weight |
Approx. 110 g |
|||
Scroll

Specifications
Model |
FD-HCB10 |
|||
Cable end |
M12, 8-pin female - 6-core cable |
|||
Length |
10 m 32.8' |
|||
Material |
PVC |
|||
Weight |
Approx. 460 g |
|||
Scroll

Specifications
Model |
FI-1000 |
|||
Display |
QVGA 2.0 model: color LCD, status indicator light |
|||
Display update cycle |
Approx. 10 times/second |
|||
Network support |
IO-Link*1 |
|||
Heat calculation function |
Unit |
MJ/h, kW, kBTU/h, GJ/h, MW, MBTU/h*2 |
||
Display resolution |
Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*2 |
|||
Pulse output increments (MJ) |
0.02–999.99*2 |
|||
Data accumulation |
Accumulation period |
Approx. 1 year |
||
Data reading |
USB2.0 |
|||
Power I/O connector |
M12 8-pin connector (male) |
|||
I/O (switchable) |
Output (Ch1/2/3/4) |
NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/ch or less, residual voltage 2.5 V or less |
||
Analog output (Ch1/2) |
4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less |
|||
External input (Ch2/3) |
Short circuit current: 1.5 mA or less; input time: 20 ms or more |
|||
Power supply |
Power voltage |
20–30 VDC, ripple (P-P) 10% included, Class 2/LPS |
||
Current consumption |
55 mA or less (display unit standalone, excluding load current)*3 |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output short circuits, and output surges |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529)*4 |
||
Ambient temperature |
–20°C to +50°C –4°F to +122°F (no freezing) |
|||
Relative humidity |
35–85% RH (no condensation) |
|||
Vibration resistance |
10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Material |
Body: PPS / PET / POM; Display window: PAR |
|||
Weight |
Approx. 120 g 4.23 oz |
|||
*1 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO). | ||||
Scroll