Power Distribution & Protection

16320 products

Showing 13825 - 13848 of 16320 products

Showing 13825 - 13848 of 16320 products
View
GVAX415 Schneider Electric
Schneider GVAX415 Schneider Electric
Sale price0.00 kr
Sold Out

Undervoltage release (MN), TeSys GV2, 415-440V AC 50 Hz, safety device for use with GV2ME

LC2K0610B7 Schneider Electric
Schneider LC2K0610B7 Schneider Electric
Sale price0.00 kr
Sold Out

TeSys K reversing contactor - 3P - AC-3 <= 440 V 6 A - 1 NO - 24 V AC coil

GVAS226 Schneider Electric
Schneider GVAS226 Schneider Electric
Sale price0.00 kr
Sold Out

TeSys GV electrical trip, MX shunt release, 220-240V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Product or Component Type Shunt trip release
Device short name GVAS

Complementary

Characteristic Value(s)
Range compatibility TeSys GV2ME
TeSys GV2LE
TeSys GV2L
TeSys GV2P
TeSys GV3L
TeSys GV3P
TeSys Deca
[Uc] control circuit voltage 220...240 V AC 60 Hz
Control circuit voltage limits 0.7...1.1 Un
[Ui] rated insulation voltage 690 V AC IEC 60947-1
600 V AC UL 60947-4-1
600 V AC CSA C22.2 No 60947-4-1
Threshold tripping voltage 0.75...0.2 Un
Inrush power in VA 14 VA AC
Inrush power in W 10.5 W
Hold-in Power Consumption in VA 5 VA AC
Hold-in power consumption in W 1.6 W
Operating time 10...15 ms IEC 60947-1
On-load factor 100 %
Connections - terminals screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)solid
screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid
screw clamp terminals 1 0.001…0.004 in² (0.75…2.5 mm²)flexible without cable end
screw clamp terminals 2 0.001…0.004 in² (0.75…2.5 mm²)flexible without cable end
screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²)flexible with cable end
screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²)flexible with cable end
Tightening torque < 1.4 N.m screw clamp terminals
Mechanical durability 10000 cycles with GV3P and GV3L
30000 cycles with GV2ME and GV2P
Quantity per Set Set of 10
Height 3.5 in (89 mm)
Width 0.7 in (18 mm)
Depth 2.6 in (66 mm)
Product Weight 0.231 lb(US) (0.105 kg)
color Dark grey
A9N61501 Schneider Electric
Schneider A9N61501 Schneider Electric
Sale price0.00 kr
Sold Out

This Acti9 C60H-DC is a low voltage direct current miniature circuit breaker (MCB). It has 1P, rated current 1A and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VDC conforming to EN 60947-2 standard and 10kA at 220VDC conforming to EN 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. It offers VisiTrip for safety during maintenance and VisiSafe to reduce intervention time. The Acti9 C60H-DC is used in direct current circuit (industrial control and automation, transport, renewable energy). This device is dedicated to industrial control, automations, transport and renewable energy applications. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 250VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The weight is 0.128kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.

Main

Characteristic Value(s)
Range Acti9
product name Acti9 C60H-DC
Product or component type Miniature circuit-breaker
Device short name C60H-DC
Device application Distribution
Poles description 1P
Number of protected poles 1
[In] rated current 1 A at 25 °C
Network type DC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 10 kA Icu at 220 V DC conforming to EN 60947-2
10 kA Icu at 220 V DC conforming to IEC 60947-2
6 kA Icu at 250 V DC conforming to EN 60947-2
6 kA Icu at 250 V DC conforming to IEC 60947-2
20 kA Icu at 110 V DC conforming to EN 60947-2
20 kA Icu at 110 V DC conforming to IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Yes conforming to EN 60947-2
Standards EN 60947-2
IEC 60947-2

Complementary

Characteristic Value(s)
Network frequency 50/60 Hz
[Ue] rated operational voltage 250 V DC
[Ics] rated service breaking capacity 15 kA 75 % conforming to EN 60947-2 - 110 V DC
15 kA 75 % conforming to IEC 60947-2 - 110 V DC
4.5 kA 75 % conforming to EN 60947-2 - 250 V DC
4.5 kA 75 % conforming to IEC 60947-2 - 250 V DC
7.5 kA 75 % conforming to EN 60947-2 - 220 V DC
7.5 kA 75 % conforming to IEC 60947-2 - 220 V DC
[Ui] rated insulation voltage 500 V DC conforming to IEC 60947-2
500 V DC conforming to EN 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
Local signalling ON/OFF indication
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
Comb busbar and distribution block compatibility Top or bottom: standard
9 mm pitches 2
Product weight 0.128 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 3000 cycles L/R = 2 ms
Provision for padlocking Padlockable
Locking options description In position O
Tightening torque Power circuit: 2.5 N.m top or bottom
Earth-leakage protection Without
A9F90272 Schneider Electric
Schneider A9F90272 Schneider Electric
Sale price0.00 kr
Sold Out

This Acti9 iC60L is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 1.6A rated current and MA tripping curve. The rated short circuit breaking capacity goes up to 40kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 4 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 78.5mm. The weight is 0.25kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

Main

Characteristic Value(s)
Device application Motor
Range Acti9
product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60L
Poles description 2P
Number of protected poles 2
[In] rated current 1.6 A
Network type AC
Trip unit technology Magnetic
Curve code MA
Breaking capacity 15 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
40 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
Standards EN 60947-2
IEC 60947-2

Complementary

Characteristic Value(s)
Network frequency 50/60 Hz
Magnetic tripping limit 12 x In +/- 20 %
[Ics] rated service breaking capacity 10 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
7.5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz
10 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
7.5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz
20 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
20 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
control type Toggle
Local signalling Trip indicator
Mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 4
Height 85 mm
Width 36 mm
Depth 78.5 mm
Product weight 0.25 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Separate block
Schneider Stock Image
Schneider LC1F225G7 Schneider
Sale price 6,376.00 kr
Only 5 units left
Buy the Schneider Electric LC1F225G7 - a genuine Schneider Electric industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Schneider Electric LC1F225G7 is a direct drop-in replacement for existing installations and ships ready for integration.
Schneider Stock Image
Schneider LC2D2501 Schneider
Sale price0.00 kr
Sold Out
Buy the Schneider Electric LC2D2501 - a genuine Schneider Electric industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Schneider Electric LC2D2501 is a direct drop-in replacement for existing installations and ships ready for integration.
A9N61500 Schneider Electric
Schneider A9N61500 Schneider Electric
Sale price0.00 kr
Sold Out

miniature circuit breaker - C60H - 1 pole - 0.5 A - C curve

A9C20164 Schneider Electric
Schneider A9C20164 Schneider Electric
Sale price 5,366.00 kr
Only 1 unit left

iCT 63A 4NO 24V 50Hz contactor

GV3G364 Schneider Electric
Schneider GV3G364 Schneider Electric
Sale price0.00 kr
Sold Out

Linergy FT - Comb busbar for parallelling 3 contactors

A9D07232 Schneider Electric
Schneider A9D07232 Schneider Electric
Sale price0.00 kr
Sold Out

Acti9 iC60 RCBO - 2P - 32 A - C Curve - 10000A/15kA - 30 mA - AC type

A9C61325 Schneider Electric
Schneider A9C61325 Schneider Electric
Sale price0.00 kr
Sold Out

It is a 3P circuit breaker with protected poles, 25 A rated current and B tripping curve. As circuit breaker, its breaking capacity, according to IEC/EN 60947-2, is 20kA at 220VAC to 240VAC, and 10kA at 380VAC to 415VAC. It allows to execute remote control, to indicate the state of the control circuit and circuit breaker state information, to connect it to the Acti9 Smartlink thanks to the prefabricated cables.

Main

Characteristic Value(s)
Device application Distribution
Control
Range Acti9
product name Reflex iC60
Device short name Reflex iC60N
Product or component type Integrated control circuit breaker
Poles description 3P
Number of protected poles 3
Network type AC
Trip unit technology Thermal-magnetic
Curve code B

Complementary

Characteristic Value(s)
[In] rated current 25 A
Network frequency 50/60 Hz
Breaking capacity code N
Breaking capacity 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC
Contact position indicator Yes
control type Remote control by continuous command
Toggle
Remote control by pulse
ON/OFF button
Control signal type Maintained
Impulse
Maintained very low voltage
Local signalling Flashing LED: device ready
Green LED: device ON
Red LED: fault
Flashing LED: device overheat
Flashing LED: device tripped
[Uc] control circuit voltage 230 V AC 50/60 Hz
24 V AC 50/60 Hz
48 V AC 50/60 Hz
24 V DC
48 V DC
[Us] rated supply voltage 230 V AC at 50/60 Hz
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 11
Height 84 mm
Width 99 mm
Depth 77 mm
Colour White
Mechanical durability 50000 cycles
Electrical durability AC-1: 50000 cycles AC 50 Hz
Provision for padlocking Padlockable
Locking options description Padlock in OFF position
Earth-leakage protection Separate block
Product compatibility With PLC
GV2AP04 Schneider Electric
Schneider GV2AP04 Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range TeSys
Device short name GV2AP
Product or component type Rotary handle kit
Accessory / separate part category Control accessory
Handle colour Black
Handle front plate colour Black

Complementary

Characteristic Value(s)
Product compatibility GV2L
GV2P
Rotary handle mounting style Extended
Locking options description 1 to 3 padlocks
Back/door distance 150…290 mm
Product weight 0.104 kg
A9E18330 Schneider Electric
Schneider A9E18330 Schneider Electric
Sale price0.00 kr
Sold Out

Acti9 iIL single indicator light - Red - 12-48 Vac/dc

LC1D12FD Schneider Electric
Schneider LC1D12FD Schneider Electric
Sale price 3,839.00 kr
Only 1 unit left

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 110 V DC coil

LC1D115B7 Schneider Electric
Schneider LC1D115B7 Schneider Electric
Sale price 14,173.00 kr
Only 3 units left

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 24 V AC 50/60 Hz coil

A9C30115 Schneider Electric
Schneider A9C30115 Schneider Electric
Sale price0.00 kr
Sold Out

This Acti9 iTLi is a modular impulse relay. It is a changeover contact with 1 normally open and 1 normally close contact. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 24VAC or 12VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 5 switching operations/minute or 100 switching operations/day. The duration of the command order should be between 50ms to 1s. It is mainly used for lighting control applications. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 18mm x (H) 84mm x (D) 60mm. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -20°C to 50°C. The storage temperature is from -40°C to 70°C. This product is compliant with IEC/EN 60669-1 and IEC/EN 60669-2-2 standard.

Main

Characteristic Value(s)
range of product Acti9
product name Acti9 iTL
Product or component type Impulse relay
Device short name iTLi
Device application Changeover relay
Poles 2P
Pole contact composition 1 NO + 1 NC
[In] rated current 16 A
Network type AC
[Uc] control circuit voltage 24 V AC 50/60 Hz
12 V DC

Complementary

Characteristic Value(s)
Network frequency 50/60 Hz
[Ue] rated operational voltage 250 V AC 50/60 Hz
control type Remote and manual control
Coil deconnection
Control signal type Impulse
Switching frequency 5 switching operations/minute
100 switching operations/day
Impulse duration 50 ms...1 s
Remote control type Illuminated push-button 3 mA
Local signalling ON/OFF indication
Mounting mode Fixed
Mounting support DIN rail
9 mm pitches 2
Height 84 mm
Width 18 mm
Depth 60 mm
Electrical durability AC-21: 200000 cycles
AC-22: 100000 cycles
Connections - terminals Control circuit: tunnel type terminals 1 cable(s) 0.5…4 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 0.5…4 mm² rigid with cable end
Control circuit: tunnel type terminals 1 cable(s) 1…4 mm² flexible
Control circuit: tunnel type terminals 1 cable(s) 1…4 mm² flexible with ferrule
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² rigid
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² rigid with cable end
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² flexible
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² flexible with ferrule
Wire stripping length 11 mm
Tightening torque 1 N.m
Range compatibility Acti9 iATEt
Acti9 iATLc
Acti9 iATLc+s
Acti9 iATLm
Acti9 iATLs
Acti9 iETL iTL 16
Acti9 iATLc+c
GV4L80N6 Schneider Electric
Schneider GV4L80N6 Schneider Electric
Sale price0.00 kr
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 80 A, Icu 50 kA, magnetic, lugs terminals

LC1D128P7 Schneider Electric
Schneider LC1D128P7 Schneider Electric
Sale price0.00 kr
Sold Out

TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 - <= 440 V 25 A - 230 V AC coil

A9R24225 Schneider Electric
Schneider A9R24225 Schneider Electric
Sale price0.00 kr
Sold Out

Acti 9 iID - RCCB - 2P - 25A - 300mA - type A

LC2D65AB7 Schneider Electric
Schneider LC2D65AB7 Schneider Electric
Sale price 10,445.00 kr
Only 2 units left

TeSys Deca reversing contactor, 3 poles (3NO), for motor control applications up to 65A/590V AC-3 (30kW@400V). Rated 65A AC-3 30kW@400V, it includes a 24V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. It provides 24V 50/60Hz AC coils, 2NO+2NC built-in auxiliary contacts (NC mirror contacts), power connection by EverLink BTR screw connectors, control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (119mm width), DIN-rail mounting or screw fixing. With pre-wired reversing power connections, mechanical interlock (without electrical interlocking). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 24V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 1.6 million cycles at 65A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Power connections by EverLink BTR screw terminals providing constant tightening pressure.

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
product name TeSys D
TeSys Deca
Product or Component Type Reversing contactor
Device short name LC2D
Contactor application Resistive load
Motor control
Utilisation category AC-3
AC-1
AC-3e
Device presentation Preassembled with reversing power busbar
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz
Power circuit <= 300 V DC
[Ie] rated operational current 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
Motor power kW 18.5 kW at 220...230 V AC 50 Hz
30 kW at 380...400 V AC 50 Hz
37 kW at 415...440 V AC 50 Hz
37 kW at 500 V AC 50 Hz
37 kW at 660...690 V AC 50 Hz
motor power HP (UL / CSA) 40 hp at 460/480 V AC 60 Hz for 3 phase motors
5 hp at 115 V AC 60 Hz for 1 phase motors
10 hp at 230/240 V AC 60 Hz for 1 phase motors
20 hp at 200/208 V AC 60 Hz for 3 phase motors
20 hp at 230/240 V AC 60 Hz for 3 phase motors
50 hp at 575/600 V AC 60 Hz for 3 phase motors
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 24 V AC 50/60 Hz
Auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV IEC 60947
Overvoltage category III
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
80 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 520 A 104 °F (40 °C) - 10 s for power circuit
900 A 104 °F (40 °C) - 1 s for power circuit
110 A 104 °F (40 °C) - 10 min for power circuit
260 A 104 °F (40 °C) - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
[Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Electrical durability 1.45 Mcycles 65 A AC-3 <= 440 V
1.4 Mcycles 80 A AC-1 <= 440 V
1.45 Mcycles 65 A AC-3e <= 440 V
Power dissipation per pole 9.6 W AC-1
6.3 W AC-3
6.3 W AC-3e
Front cover With
Interlocking type Mechanical
Mounting Support Rail
Plate
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
Product Certifications UL
CSA
RINA
GOST
CCC
DNV
LROS (Lloyds register of shipping)
GL
BV
UKCA
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid
Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)flexible without cable end
Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)flexible without cable end
Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)flexible with cable end
Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)flexible with cable end
Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)solid
Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)solid
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Power circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm)
Power circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.002…0.04 in² (1…25 mm²) hexagonal 0.2 in (4 mm)
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 22.1 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Operating time 4...19 ms opening
12...26 ms closing
Safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 6 Mcycles
Maximum operating rate 3600 cyc/h 140 °F (60 °C)

Complementary

Characteristic Value(s)
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz
0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz
1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
160 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 4…5 W 50/60 Hz
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Insulation resistance > 10 MOhm for signalling circuit
A9XPV748 Schneider Electric
Schneider A9XPV748 Schneider Electric
Sale price0.00 kr
Sold Out

This Acti9 product is a cuttable horizontal comb busbar for Acti9 iC40 with 9mm auxiliary and vigi module. It is dedicated to (Auxiliary, Neutral, Line, Vigi) installations. The distribution type is (Aux, N, L1, Vigi). It is a set of 1 product. It is suitable for 18 devices with 3P+N pole and with associated auxiliaries and Vigi module. The length is 862mm. The total number of modules of 18mm is 48. The Ie rated operational current at 40°C is 80A. The Ui rated insulation voltage is 400VAC. The Ue rated operational voltage is 230VAC. The color of the device is white (RAL 9003). The pollution degree is 3. The degree of protection is IP20 with end-pieces and tooth covers. According to IEC 60695-2-1 standard, the fire resistance is self-extinguishing at 960°C within 30s. It complies with IEC 61439-1 standards.

Main

Characteristic Value(s)
Range Acti9
Product or component type Comb busbar
Mounting mode Horizontal
Accessory / separate part category Connection accessory
Lines description 3L + N
Length in 18 mm modules 48
Standards EN/IEC 61439-1

Complementary

Characteristic Value(s)
Number of ways 18 ways Aux + N + L + Vigi
Distribution type Aux N L1 Vigi Aux N L2 Vigi Aux N L3 Vigi
Poles configuration for 1 way 1 x 1P + N
Connection pitch 9 mm between phase and neutral
Connector type Tooth
Distance between way 45 mm
Marking N L1 N L2 N L3
Insulation Insulated
Device presentation Cuttable
[Ie] rated operational current 80 A at 40 °C
[Ue] rated operational voltage 230 V AC Ph/N
[Ui] rated insulation voltage 400 V AC conforming to IEC 61439-1
[Uimp] rated impulse withstand voltage 4 kV
Mounting location Top on tunnel type terminals
9 mm pitches 96
Height 29 mm
Width 862 mm
Depth 26 mm
Product weight 472 g
Colour White (RAL 9003)
Range compatibility Acti9 Acti9 C40
Acti9 Acti9 C40 Vigi
Acti9 Acti9 DT40
Acti9 Acti9 DT40 Vigi
Acti9 Acti9 iDPN
Acti9 Acti9 iDPN Vigi
Multi9 Multi9 N40 Vigi
Acti9 Acti9 iC40
Acti9 Acti9 iDT40
Acti9 Acti9 iDD40
Acti9 Acti9 iDD40 TG
Acti9 Vigi iTG40
Acti9 Acti9 iIG40
Acti9 Acti9 iCV40
Acti9 Vigi iCG40
Acti9 Acti9 iID40
Schneider Stock Image
Schneider LC1F185M6 Schneider
Sale price 8,381.00 kr
Only 3 units left
Buy the Schneider Electric LC1F185M6 - a genuine Schneider Electric industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Schneider Electric LC1F185M6 is a direct drop-in replacement for existing installations and ships ready for integration.
Schneider New Stock Image
Schneider LC1D50AF7C Schneider
Sale price 1,082.00 kr
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed