PLC Systems

351 products

Showing 337 - 351 of 351 products

Showing 337 - 351 of 351 products
View
XPSMC32ZC Schneider Electric
Schneider XPSMC32ZC Schneider Electric
Sale price 25,540.00 kr
Only 5 units left

This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for serial link communication with Modbus protocol. Transmission rate are 1200/2400/4800/9600 and 19200bps, and another SUB-D 9-pin male port for CANopen communication. Transmission rate are 20/50/125 and 250kbps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÜV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Configurable safety controller
Safety module name XPSMC
Safety use category Category 4 maximum EN 954-1/EN/ISO 13849-1
PLE maximum ISO 13849-1
SIL 3 maximum IEC 61508
Type of start Configurable
Standards IEC 60947-5-1
EN 574/ISO 13851
EN 1760-1/ISO 13856-1
IEC 61496-1
IEC 61508
EN 954-1/EN/ISO 13849-1
IEC 60204-1
Product Certifications UL
TÜV
CSA
[Us] Rated Supply Voltage 24 V DC - 20...20 %
Number of inputs 32
Communication port protocol CANopen 1 SUB-D 9-pin male, serial link 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps
Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
Safety level Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1
Can reach SIL 3 IEC 61508

Complementary

Characteristic Value(s)
Function of module Dynamic monitoring of hydraulic valves on linear presses
Eccentric press
Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring
Enabling switch monitoring, 2 or 3 contacts
Foot switch monitoring
Guard monitoring for injection presses and blowing machines
Guard monitoring with 1 or 2 limit switches
Hydraulic press
Magnetic switch monitoring category 4 EN/IEC 61496
Monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851
Muting function of light curtains
Position selector
Safety mat monitoring
Safety time delays
Shaft/chain breaking monitor
Zero speed detection
Light curtain monitoring category 4 IEC 61496
Two-hand control category 3 EN 574/ISO 13851
Synchronisation time between inputs Depending on configuration selected
Power Consumption in W 12 W
Input protection type External fuse 16 A
[Uc] control circuit voltage 28.8 V
Maximum line resistance 100 Ohm <6561.7 ft (2000 m)
Output type 2 relays, 2 NO contacts (4 NO total)
Solid state, 6, volt-free
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 2 A 24 V static output circuit
1.5 A 24 V DC-13)50 ms relay output
Output thermal current 4 A for both outputs simultaneously
6 A for 1 output and 2 A for the other relay output
[Ith] conventional free air thermal current 16 A relay output
6.5 A static output circuit
Associated fuse rating 16 A gL power supply
4 A gL relay output
6 A fast blow relay output
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Response Time Configurable : 20 ms or 30 ms with software XPSMCWIN
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Method of access Slave
Exchange size 14 words
Number of addresses 1…127 CANopen
1…247 Modbus
Parity Even Modbus
No Modbus
Odd Modbus
Data format 1 start bit/8 data bits
1 stop bit even or odd
2 stop bits without parity
RTU (Remote Terminal Unit) mode
Supported modbus function 01 8-bit output data/32-bit input data
02 32-bit input data/8-bit output data
03 information and errors
Local signalling 48 LEDs
Mounting Support Mounting plate
Depth 6.02 in (153 mm)
Height 6.0 in (151.5 mm)
Width 2.9 in (74 mm)
Product Weight 1.85 lb(US) (0.84 kg)
XPSMC32ZP Schneider Electric
Schneider XPSMC32ZP Schneider Electric
Sale price 9,441.00 kr
Only 5 units left

This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for a serial link communication with Modbus protocol. The transmission rate are 1200bps, 2400bps, 4800bps, 9600bps or 19200bps, and 1 SUB-D 9-pin female port for PROFIBUS communication. The transmission rate is 12Mbps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÜV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Configurable safety controller
Safety module name XPSMC
Safety use category Category 4 maximum EN 954-1/EN/ISO 13849-1
PLE maximum ISO 13849-1
SIL 3 maximum IEC 61508
Type of start Configurable
Standards EN 954-1/EN/ISO 13849-1
IEC 61496-1
IEC 61508
IEC 60204-1
EN 1760-1/ISO 13856-1
EN 574/ISO 13851
IEC 60947-5-1
Product Certifications CSA
UL
TÜV
[Us] Rated Supply Voltage 24 V DC - 20...20 %
Number of inputs 32
Communication port protocol Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
Profibus 1 SUB-D 9-pin female, serial link 12 Mbps
Safety level Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1
Can reach SIL 3 IEC 61508

Complementary

Characteristic Value(s)
Function of module Dynamic monitoring of hydraulic valves on linear presses
Eccentric press
Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring
Enabling switch monitoring, 2 or 3 contacts
Foot switch monitoring
Guard monitoring for injection presses and blowing machines
Guard monitoring with 1 or 2 limit switches
Hydraulic press
Magnetic switch monitoring category 4 EN/IEC 61496
Monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851
Muting function of light curtains
Position selector
Safety mat monitoring
Safety time delays
Shaft/chain breaking monitor
Zero speed detection
Light curtain monitoring category 4 IEC 61496
Two-hand control category 3 EN 574/ISO 13851
Synchronisation time between inputs Depending on configuration selected
Power Consumption in W 12 W
Input protection type External fuse 16 A
[Uc] control circuit voltage 28.8 V
Maximum line resistance 100 Ohm <6561.7 ft (2000 m)
Output type 2 relays, 2 NO contacts (4 NO total)
Solid state, 6, volt-free
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 2 A 24 V static output circuit
1.5 A 24 V DC-13)50 ms relay output
Output thermal current 4 A for both outputs simultaneously
6 A for 1 output and 2 A for the other relay output
[Ith] conventional free air thermal current 16 A relay output
6.5 A static output circuit
Associated fuse rating 16 A gL power supply
4 A gL relay output
6 A fast blow relay output
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Response Time Configurable : 20 ms or 30 ms with software XPSMCWIN
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Method of access Slave
Exchange size 14 words
Number of addresses 1…125 Profibus
1…247 Modbus
Parity Even Modbus
No Modbus
Odd Modbus
Data format 1 start bit/8 data bits
1 stop bit even or odd
2 stop bits without parity
RTU (Remote Terminal Unit) mode
Supported modbus function 01 8-bit output data/32-bit input data
02 32-bit input data/8-bit output data
03 information and errors
Local signalling 48 LEDs
Mounting Support Mounting plate
Depth 6.02 in (153 mm)
Height 6.0 in (151.5 mm)
Width 2.9 in (74 mm)
Product Weight 1.85 lb(US) (0.84 kg)
XPSMC32ZPACK Schneider Electric
Schneider XPSMC32ZPACK Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Kit configurable safety controller
Safety module name XPSMC
Safety use category Category 4 maximum EN 954-1/EN/ISO 13849-1
PLE maximum EN/ISO 13849-1
SIL 3 maximum IEC 61508
Type of start Configurable
Standards EN 954-1/EN/ISO 13849-1
EN/IEC 60947-5-1
EN/IEC 60204-1
EN/IEC 61496-1
IEC 61508
EN 574/ISO 13851
EN 1760-1/ISO 13856-1
Product Certifications UL
CSA
TÜV
[Us] Rated Supply Voltage 24 V DC - 20...20 %
Number of inputs 32
Communication port protocol Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
Safety level Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1
Can reach SIL 3 IEC 61508

Complementary

Characteristic Value(s)
Kit composition Safety controller
Ethernet cable 2m
Configuration software
Connection cable
Set of cage clamp terminals
USB/RS485 converter
Set of screw terminals
Packaging small model for software configuration
VDE slot screwdriver 2.5 x 75 mm
Printed packaging label 80 x 50 mm
Function of module Dynamic monitoring of hydraulic valves on linear presses
Eccentric press
Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring
Enabling switch monitoring, 2 or 3 contacts
Foot switch monitoring
Guard monitoring for injection presses and blowing machines
Guard monitoring with 1 or 2 limit switches
Hydraulic press
Magnetic switch monitoring
Monitoring safety stop at top dead centre on eccentric press
Muting function of light curtains
Position selector
Safety mat monitoring
Safety time delays
Shaft/chain breaking monitor
Zero speed detection
Light curtain monitoring category 4 EN/IEC 61496
Two-hand control category 3 EN 574/ISO 13851
Synchronisation time between inputs Depending on configuration selected
Power Consumption in W 12 W
Input protection type External fuse 16 A
[Uc] control circuit voltage 28.8 V
Maximum line resistance 100 Ohm <6561.7 ft (2000 m)
Output type 2 relays, 2 NO contacts (4 NO total)
Solid state, 6, volt-free
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 2 A 24 V static output circuit
1.5 A 24 V DC-13)50 ms relay output
Output thermal current 4 A for both outputs simultaneously
6 A for 1 output and 2 A for the other relay output
[Ith] conventional free air thermal current 16 A relay output
6.5 A static output circuit
Associated fuse rating 16 A gL power supply
4 A gL relay output
6 A fast blow relay output
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Response Time Configurable : 20 ms or 30 ms with software XPSMCWIN
[Ui] rated insulation voltage 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Method of access Slave
Exchange size 14 words
Number of addresses 1…247 Modbus
Parity Even Modbus
No Modbus
Odd Modbus
Data format 1 start bit/8 data bits
1 stop bit even or odd
2 stop bits without parity
RTU (Remote Terminal Unit) mode
Supported modbus function 01 8-bit output data/32-bit input data
02 32-bit input data/8-bit output data
03 information and errors
Local signalling 46 LEDs
Mounting Support Mounting plate
Depth 6.02 in (153 mm)
Height 6.0 in (151.5 mm)
Width 2.9 in (74 mm)
Product Weight 1.85 lb(US) (0.84 kg)
XPSMCMCP0802 Schneider Electric
Schneider XPSMCMCP0802 Schneider Electric
Sale price 7,105.00 kr
Only 7 units left

This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 2 start/restart interlock inputs, 2 output OSSD pairs, 4 test outputs and 2 status outputs and is fitted with captive screw clamp terminals. It embeds a Mini USB 2.0 connector to receive the configuration done with the software EcoStruxure Machine Expert - HVAC. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It can be used as standalone or with fourteen expansion modules. The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Main

Characteristic Value(s)
Range of Product Modicon Safety automation
Device short name XPSMCM
Electrical Connection Screw terminal
Product or Component Type Safety controller CPU
[Us] rated supply voltage 24 V - 20...20 % DC
Number of inputs 8 digital input connection
2 digital interlock start/restart or external device monitoring
Number of outputs 2 safety outputs OSSD contactor/drive connection
4 test line control outputs
2 configurable diagnostic connection
Discrete input voltage 24 V
Discrete output current 400 mA
Discrete input current 400 mA
Discrete input type Safety input
PNP
Discrete output type PNP
Function of module Emergency stop ISO 13850
Guard monitoring EN/ISO 14119
Enabling switch monitoring IEC 60947-5-1
Light curtain monitoring IEC 61496-1
Foot switch monitoring IEC 60947-5-1
Magnetic switch monitoring EN/ISO 14119
Two-hand control EN 574
Safety mat monitoring EN/ISO 14119
Enabling switch monitoring IEC 61326-1
Muting function of light curtains IEC 60947-5-1
Counter functions IEC 61800-5-2
Speed monitoring IEC 61800-5-2
Backplane connector Without

Complementary

Characteristic Value(s)
Synchronisation time between inputs < 0.5 ms
Power dissipation in W 3 W
Maximum number of I/O expansion module 14 128 input
14 16 output
Integrated connection type Backplane expansion bus
USB 2.0 port
Data storage equipment SD card optional)
Inductive load 30 mH
Load capacitance 0.82 µF
Safety level Can reach category 4 ISO 13849-1
Can reach PL = e ISO 13849-1
Type 4 IEC 61496-1
SILCL 3 IEC 62061
Quality labels CE
Local signalling 1 LED green PWR power ON
1 LED green RUN RUN (status)
1 LED red E IN internal error
1 LED red E EX external error
1 LED orange COM communication
1 LED blue EN master enable
8 LEDs yellow IN input status
2 LEDs green/red OUT output status
2 LEDs yellow RST restart signal
2 LEDs yellow STATUS output channel
Connections - terminals 6 captive screw terminals, removable terminal block
Cable cross section 0.0003…0.002 in² (0.2…1.5 mm²) - AWG 24...AWG 16 flexible without cable end
0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 flexible without cable end
0.0004…0.002 in² (0.25…1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel
0.0004…0.004 in² (0.25…2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel
0.0004…0.002 in² (0.25…1.5 mm²) - AWG 23...AWG 16 flexible with cable end, without bezel
0.0008…0.002 in² (0.5…1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel
0.0003…0.002 in² (0.2…1 mm²) - AWG 24...AWG 18 solid without cable end
0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 solid without cable end
Mounting support Omega 35 mm DIN rail EN 50022
Depth 4.5 in (114.5 mm)
Height 3.9 in (99 mm)
Width 0.9 in (22.5 mm)
Product Weight 0.55 lb(US) (0.25 kg)
XPSMCMCP0802BC Schneider
Schneider XPSMCMCP0802BC Schneider
Sale price0.00 kr
Sold Out

This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 2 start/restart interlock inputs, 2 output OSSD pairs, 4 test outputs and 2 status outputs and is fitted with captive screw clamp terminals. It embeds a Mini USB 2.0 connector to receive the configuration done with the software SoSafe Configurable. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It can be used as standalone or with fourteen expansion modules. The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. It weighs 0.26kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The kit includes 1 x safety controller CPU and 1 x backplane expansion connector. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.

Main

Characteristic Value(s)
Range of Product Modicon Safety automation
Device short name XPSMCM
Electrical Connection Screw terminal
Product or Component Type Modular safety controller CPU kit
[Us] rated supply voltage 24 V - 20...20 % DC
Number of inputs 8 digital input connection
2 digital interlock start/restart or external device monitoring
Number of outputs 2 safety outputs OSSD contactor/drive connection
4 test line control outputs
2 configurable diagnostic connection
Discrete input voltage 24 V
Discrete output current 400 mA
Discrete input current 400 mA
Discrete input type PNP
Safety input
Discrete output type PNP
Kit composition 1 safety controller CPU
1 backplane expansion connector
Function of module Emergency stop ISO 13850
Guard monitoring EN/ISO 14119
Enabling switch monitoring IEC 60947-5-1
Light curtain monitoring IEC 61496-1
Foot switch monitoring IEC 60947-5-1
Magnetic switch monitoring EN/ISO 14119
Two-hand control EN 574
Safety mat monitoring EN/ISO 14119
Enabling switch monitoring IEC 61326-1
Muting function of light curtains IEC 60947-5-1
Counter functions IEC 61800-5-2
Speed monitoring IEC 61800-5-2
Backplane connector With

Complementary

Characteristic Value(s)
Synchronisation time between inputs < 0.5 ms
Power dissipation in W 3 W
Maximum number of I/O expansion module 14 128 input
14 16 output
Integrated connection type Backplane expansion bus
USB 2.0 port
Data storage equipment SD card optional)
Inductive load 30 mH
Load capacitance 0.82 µF
Safety level Can reach category 4 ISO 13849-1
Can reach PL = e ISO 13849-1
Type 4 IEC 61496-1
SILCL 3 IEC 62061
Quality labels CE
Local signalling 1 LED green PWR power ON
1 LED green RUN RUN (status)
1 LED red E IN internal error
1 LED red E EX external error
1 LED orange COM communication
1 LED blue EN master enable
8 LEDs yellow IN input status
2 LEDs green/red OUT output status
2 LEDs yellow RST restart signal
2 LEDs yellow STATUS output channel
Connections - terminals 2 captive screw terminals, removable terminal block
1 captive screw terminals, removable terminal block
Cable cross section 0.0003…0.002 in² (0.2…1.5 mm²) - AWG 24...AWG 16 flexible without cable end
0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 flexible without cable end
0.0004…0.002 in² (0.25…1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel
0.0004…0.004 in² (0.25…2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel
0.0004…0.002 in² (0.25…1.5 mm²) - AWG 23...AWG 16 flexible with cable end, without bezel
0.0008…0.002 in² (0.5…1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel
0.0003…0.002 in² (0.2…1 mm²) - AWG 24...AWG 18 solid without cable end
0.0003…0.004 in² (0.2…2.5 mm²) - AWG 24...AWG 14 solid without cable end
Mounting support Omega 35 mm DIN rail EN 50022
Depth 4.5 in (114.5 mm)
Height 3.9 in (99 mm)
Width 0.9 in (22.5 mm)
Product Weight 0.57 lb(US) (0.26 kg)
XPSMCMCP0802BCG Schneider
Schneider XPSMCMCP0802BCG Schneider
Sale price0.00 kr
Sold Out

Safety Controller CPU spring term. combined with backplane expansion connector

XPSMCMCP0802G Schneider
Schneider XPSMCMCP0802G Schneider
Sale price 3,656.00 kr
Only 1 unit left

Controller with 8 inputs 2 outputs monitors expansion modules with spring term

XPSMF3542 Schneider Electric
Schneider XPSMF3542 Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety PLC compact
Safety module name XPSMF35
Safety module application For numerous machine safety functions and for the protection of personnel
Safety use category Category 4 EN 954-1/ISO 13849-1
SIL 3 IEC 61508
Structure type 10BASE-T/100BASE-TX, Modbus TCP/IP
10BASE-T/100BASE-TX, safe Ethernet

Complementary

Characteristic Value(s)
Function of module Closed circuit scanning of input channels analogue input circuit
Measuring 0 to 20 mA currents using shunt analogue input circuit
Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Single-pole measuring of 0 to 10 V voltages analogue input circuit
[Us] Rated Supply Voltage 24 V DC - 15...20 %
No load current 0.75 A
Protection Type Internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response Time Depending on size of application
Memory description User logic 250 kB application
User logic 250 kB data
Discrete input number 24 not isolated
Voltage state 0 guaranteed <= 5 V discrete input
Voltage state 1 guaranteed 24...30 V discrete input
Current state 0 guaranteed 1...1.5 mA discrete input)
Current state 1 guaranteed 3.5...4.5 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Input protection type Protected against short-circuit to earth
Protected against short-circuit
Input overvoltage protection 500 V discrete input IEC 61000-4-5
-4…15 V analogue input circuit
Discrete output number 8
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 4 and 8)
2 A 122 °F (50 °C) channels 4 and 8)
0.5 A 140 °F (60 °C) channels 1 to 3 and 5 to 7)
<= 7 mA all channels)
Minimum load 2 mA per discrete output
Maximum leakage current 1 mA 2 V at state 0 discrete output
Overload protection Shutdown of outputs concerned with cyclic reconnection
Analogue input number 8
Analogue Output Type Not isolated
External resistance 250 Ohm analogue input circuit
500 Ohm analogue input circuit
Analogue input range 0...20 mA 500 Ohm
0...10 V
Input voltage limits 0.1...11.5 V analogue input circuit
Input current limits 0.4…23 mA 500 Ohm analogue input circuit
Analogue input resolution 12 bits
Safety accuracy +/- 2 % analogue input circuit
Maximum internal input resistance 500 MOhm for signal source analogue input circuit
1 kOhm analogue input circuit
3.7 Ohm counting inputs
Counting input number 2
Counting input type Non isolated
Counting frequency 100 kHz
Operating threshold 0...0.05 V, 5 V low counting inputs
13...33 V, 24 V high counting inputs
-3...5 V, 24 V low counting inputs
4...6 V, 5 V high counting inputs
Counter inputs resolution 24 bits
DV/dt 1 V/µs counting inputs
Communication port protocol Modbus TCP/IP 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Safe Ethernet 4 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Modbus RTU 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Exchange mode Half duplex, full duplex, autonegotiation Modbus TCP/IP
Half duplex, full duplex, autonegotiation safe Ethernet
Method of access Slave Modbus
Slave Modbus TCP/IP
Slave Profibus
Number of addresses 122 Modbus
Concept Transparent Ready, Modbus TCP/IP
Web server Class A10, Modbus TCP/IP
Web services Modbus identification request, Modbus TCP/IP
Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP
Modbus TCP/IP server, Modbus TCP/IP
Standard 502, Modbus TCP/IP
Operating distance <= 500 m between station) shielded dual twisted pair cable counting inputs
<= 100 m between station) discrete input
<= 100 m between station) discrete output
<= 300 m between station) analogue input circuit
Number of terminal blocks 1 counting inputs
1 power supply
2 discrete output
4 analogue input circuit
5 discrete input
Connections - terminals Analogue input circuit captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end
Counting inputs captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible with cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 22...AWG 16) flexible without cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.25...2 x 1 mm² AWG 22...AWG 18) flexible without cable end
Power supply captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² AWG 22...AWG 16) flexible with cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Counting inputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end
Counting inputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) solid without cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end
Counting inputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 22...AWG 20) flexible with cable end
Analogue input circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end
Counting inputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 22...AWG 16) flexible without cable end
Analogue input circuit captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end
Counting inputs captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² AWG 28...AWG 20) solid without cable end
Analogue input circuit captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end
Counting inputs captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² AWG 28...AWG 18) flexible without cable end
Analogue input circuit captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end
Counting inputs captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² AWG 22) flexible without cable end
Tightening torque 1.95…2.21 lbf.in (0.22…0.25 N.m)
Wire stripping length 0.4 in (9 mm)
Current consumption 9 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 2.6 in (66.5 mm)
Height 4.4 in (113 mm)
Width 10.0 in (253 mm)
Product Weight 2.6 lb(US) (1.2 kg)
XPSMF4000 Schneider Electric
Schneider XPSMF4000 Schneider Electric
Sale price0.00 kr
Sold Out

Preventa safety PLC compact - Safe Ethernet

XPSMF4002 Schneider Electric
Schneider XPSMF4002 Schneider Electric
Sale price0.00 kr
Sold Out

Preventa safety PLC compact - Safe Ethernet, Modbus TCP/IP

XPSMF4020 Schneider Electric
Schneider XPSMF4020 Schneider Electric
Sale price0.00 kr
Sold Out

Preventa safety PLC compact - Safe Ethernet, Modbus RTU

XPSMF4022 Schneider Electric
Schneider XPSMF4022 Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety PLC compact
Safety module name XPSMF40
Safety module application F use with numerous machine safety functions and for the protection of personel
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Structure type 10BASE-T/100BASE-TX, Modbus TCP/IP
10BASE-T/100BASE-TX, safe Ethernet

Complementary

Characteristic Value(s)
Function of module Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Monitoring short-circuit and line break line control outputs
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
No load current 0.5 A
Protection Type 10 A internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response Time Depending on size of application
Memory description User logic 250 kB application
User logic 250 kB data
Group of channels 2 groups of 4 line control outputs
Discrete I/O number 24 configurable
Maximum discrete input number 24 not isolated
Voltage state 0 guaranteed <= 24 V discrete input
Voltage state 1 guaranteed 24...30 V discrete input
Current state 0 guaranteed <= 1.5 mA discrete input)
Current state 1 guaranteed 3.5...4.5 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Maximum input resistance 7 kOhm
Input overvoltage protection -10…35 V discrete input
Maximum discrete output number 24 not isolated
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24)
2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24)
0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23)
<= 7 A all channels)
Minimum load 2 mA per discrete output
Maximum leakage current 1 mA 2 V at state 0 discrete output
Overload protection Shutdown of outputs concerned with cyclic reconnection
Output voltage 20 V line control outputs
Nominal output current 60 mA line control outputs
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Modbus TCP/IP 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Modbus RTU 1 RJ45, RS485 shielded dual twisted pair cable
Exchange mode Half duplex, full duplex, autonegotiation Modbus TCP/IP
Half duplex, full duplex, autonegotiation safe Ethernet
Method of access Slave Modbus TCP/IP
Slave V0 Modbus serial
Number of addresses 122 Modbus serial
Concept Transparent Ready, Modbus TCP/IP
Web server Class A10, Modbus TCP/IP
Web services Modbus identification request, Modbus TCP/IP
Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP
Modbus TCP/IP server, Modbus TCP/IP
Standard 502, Modbus TCP/IP
Maximum number of connections 1 to 20, Modbus TCP/IP
Operating distance <= 300 m between station discrete input
<= 300 m between station discrete output
Number of terminal blocks 1 power supply
2 line control outputs
6 discrete input/output circuit
8 line control outputs
Connections - terminals Discrete input/output circuit captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Line control outputs captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible with cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible with cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible without cable end
Tightening torque Discrete input/output circuit 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Line control outputs 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Power supply 4.4 lbf.in (0.5 N.m) captive screw clamp terminals
Wire stripping length 0.4 in (10 mm) power supply captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive spring terminals
0.4 in (9 mm) line control outputs captive screw clamp terminals
0.4 in (9 mm) line control outputs captive spring terminals
0.4 in (9 mm) power supply captive spring terminals
Current consumption 8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 6.02 in (153 mm)
Height 6.0 in (151.5 mm)
Width 2.9 in (74 mm)
Product Weight 2.2 lb(US) (1 kg)
XPSMF4040 Schneider Electric
Schneider XPSMF4040 Schneider Electric
Sale price0.00 kr
Sold Out

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety PLC compact
Safety module name XPSMF40
Safety module application F use with numerous machine safety functions and for the protection of personel
Safety use category Category 4 maximum EN 954-1
Performance level e EN/ISO 13849-1
SIL 3 EN/IEC 61508
Structure type 10BASE-T/100BASE-TX, safe Ethernet

Complementary

Characteristic Value(s)
Function of module Monitoring safety actuators discrete output
Monitoring safety detection discrete input
Monitoring safety dialogue discrete input
Monitoring safety dialogue discrete output
Monitoring short-circuit and line break line control outputs
[Us] Rated Supply Voltage 24 V DC - 15...20 %
Supply SELV or PELV EN/IEC 60950
No load current 0.5 A
Protection Type 10 A internal fuse
Clock With, supplied by backup capacitor for 1 week following loss of supply
Response Time Depending on size of application
Memory description User logic 250 kB application
User logic 250 kB data
Group of channels 2 groups of 4 line control outputs
Discrete I/O number 24 configurable
Maximum discrete input number 24 not isolated
Voltage state 0 guaranteed <= 24 V discrete input
Voltage state 1 guaranteed 24...30 V discrete input
Current state 0 guaranteed <= 1.5 mA discrete input)
Current state 1 guaranteed 3.5...4.5 mA discrete input)
Discrete input voltage 20 V
Discrete input current 100 mA
Maximum input resistance 7 kOhm
Input overvoltage protection -10…35 V discrete input
Maximum discrete output number 24 not isolated
Discrete output voltage 24 V DC
Output voltage tolerance +/- 2%
Discrete output current 1 A 140 °F (60 °C) channels 4, 8, 12, 16, 20 and 24)
2 A 122 °F (50 °C) channels 4, 8, 12, 16, 20 and 24)
0.5 A 140 °F (60 °C) channels 1 to 3, 5 to 7, 9 to 11,13 to 15, 17 to 19, 21 to 23)
<= 7 A all channels)
Minimum load 2 mA per discrete output
Maximum leakage current 1 mA 2 V at state 0 discrete output
Overload protection Shutdown of outputs concerned with cyclic reconnection
Output voltage 20 V line control outputs
Nominal output current 60 mA line control outputs
Communication port protocol Safe Ethernet 2 RJ45 100 Mbps, 10 Mbps dual twisted pair cable, category 5D or better
Profibus 1 SUB-D 9-pin female, RS485 shielded dual twisted pair cable
Exchange mode Half duplex, full duplex, autonegotiation safe Ethernet
Method of access Slave V0 Profibus
Operating distance <= 300 m between station discrete input
<= 300 m between station discrete output
Number of terminal blocks 1 power supply
2 line control outputs
6 discrete input/output circuit
8 line control outputs
Connections - terminals Discrete input/output circuit captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Line control outputs captive spring terminals, 1 x 0.5 mm² AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 25...AWG 15) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² AWG 28...AWG 16) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² AWG 23...AWG 20) flexible with cable end
Discrete input/output circuit captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Line control outputs captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² AWG 23...AWG 15) flexible without cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible with cable end
Power supply captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 14) flexible without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 16) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.14...1 x 1.5 mm² AWG 26...AWG 17) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible without cable end
Power supply captive spring terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) solid without cable end
Discrete input/output circuit captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Line control outputs captive spring terminals, 1 x 0.25...1 x 0.34 mm² AWG 22) flexible without cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible with cable end
Power supply captive spring terminals, 1 x 0.25...1 x 2.5 mm² AWG 23...AWG 12) flexible without cable end
Tightening torque Discrete input/output circuit 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Line control outputs 1.95…2.21 lbf.in (0.22…0.25 N.m) captive screw clamp terminals
Power supply 4.4 lbf.in (0.5 N.m) captive screw clamp terminals
Wire stripping length 0.4 in (10 mm) power supply captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive screw clamp terminals
0.4 in (9 mm) discrete input/output circuit captive spring terminals
0.4 in (9 mm) line control outputs captive screw clamp terminals
0.4 in (9 mm) line control outputs captive spring terminals
0.4 in (9 mm) power supply captive spring terminals
Current consumption 8 A 24 V DC on power supply
Mounting Support 35 mm symmetrical DIN rail
Depth 6.02 in (153 mm)
Height 6.0 in (151.5 mm)
Width 2.9 in (74 mm)
Product Weight 2.2 lb(US) (1 kg)
XPSMP11123 Schneider Electric
Schneider XPSMP11123 Schneider Electric
Sale price 9,411.00 kr
Only 1 unit left

This XPSMP safety contoller can handle 2 independent safety functions. This safety controller with pre-defined functions meets the requirements of PL e/Category 4 conforming EN ISO 13849-1 and SILCL 3 conforming to EN/IEC 61508 and EN/IEC 62061. It enables two independent safety functions (selected from a choice of 15 pre-defined configurations) to be performed using the same product. It complies with the most stringent functional safety requirements thanks to multiple configurable safety functions. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Safety controller with pre-defined function
Safety module name XPSMP
Safety module application 2 independent functions
Safety use category Category 4 maximum EN/IEC 60954-1
Type of start Automatic or unmonitored 1)
Automatic or unmonitored 10)
Automatic or unmonitored 11)
Automatic or unmonitored 14)
Automatic or unmonitored 3)
Automatic or unmonitored 5)
Automatic or unmonitored 7)
Monitored 12)
Monitored 13)
Monitored 15)
Monitored 2)
Monitored 4)
Monitored 6)
Monitored 8)
Monitored 9)
Checks Configuration 10)
Configuration 13)
Configuration 3)
Configuration 4)
Configuration 5)
Configuration 6)
Configuration 9)
Standards EN/IEC 60947-1 + A11
EN/IEC 60947-5-1
EN/IEC 60204-1
DIN V VDE 801 + A1
Product Certifications UL
CSA
BIA
[Us] Rated Supply Voltage 24 V DC - 20...20 %
Connections - terminals Captive screw clamp terminals flexible 0.14...0.75 mm² without cable end, 2 wires
Captive screw clamp terminals solid 0.14...0.75 mm² without cable end, 2 wires
Captive screw clamp terminals flexible 0.14...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals solid 0.14...2.5 mm² without cable end, 1 wire
Captive screw clamp terminals flexible 0.25...1 mm² with cable end, without bezel, 2 wires
Captive screw clamp terminals flexible 0.25...1.5 mm² with cable end, with bezel, 1 wire
Captive screw clamp terminals flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire
Captive screw clamp terminals flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires
Safety level Can reach PL e/category 4 EN/ISO 13849-1
Can reach SIL 3 EN/IEC 62061

Complementary

Characteristic Value(s)
Function of module 0 functions disabled (factory setting)
1 emergency stop monitoring 1-channel wiring, category 2
10 enabling grip switch monitoring (3-position switch), category 4
11 sensing mat and edges monitoring, category 3
12 sensing mat and edges monitoring, category 3
13 relay output safety light curtain monitoring, category 4
14 coded magnetic switch monitoring, category 4
15 coded magnetic switch monitoring, category 4
2 emergency stop monitoring 1-channel wiring, category 2
3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
9 guard monitoring for injection presses and blowing machines, category 4
Synchronisation time between inputs 0.5 s 13)
1.5 s 14)
1.5 s 15)
1.5 s 5)
1.5 s 6)
1.5 s 9)
Unlimited 3)
Unlimited 4)
Unlimited 7)
Unlimited 8)
Power Consumption in W 5 W
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V
Maximum line resistance 100 Ohm <6561.7 ft (2000 m)
Number of safety circuits 3 NO relays per function (6 NO total), volt-free
Number of additional circuits 3 solid state outputs
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 20 mA 24 V static output circuit
1.5 A 24 V DC-13)50 ms relay output
Output thermal current 2 A for 1 output and 4 A for the other 2 outputs relay
3.3 A for all 3 outputs relay simultaneously
6 A for 1 output and 2 A for the other 2 outputs relay
[Ith] conventional free air thermal current 20 A
Associated fuse rating 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Maximum response time on input open 30 ms
[Ui] rated insulation voltage 300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Uimp] rated impulse withstand voltage 4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Local signalling 12 LEDs
Mounting Support 35 mm symmetrical DIN rail
Depth 4.5 in (114 mm)
Height 3.9 in (99 mm)
Width 1.8 in (45 mm)
Product Weight 0.71 lb(US) (0.32 kg)
XPSMP11123P Schneider Electric
Schneider XPSMP11123P Schneider Electric
Sale price 5,944.00 kr
Only 3 units left

module XPS-MP - 2 independent functions - 24 V DC