This Modicon MCM safe output expansion module has 2 start/restart interlock inputs, 2 output OSSD pairs and 2 status outputs and is fitted with captive screw clamp terminals. It is designed to monitor remotely your safe I/O. It is furnished with screw clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. This safe I/O module figures configurable filters and delays for each single input, configurable output activation and de-activation delays, independent control of pairs of outputs, and configurable diagnostic output signals. This module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, input and output status). This safe I/O module is connected to the safety controller via the backplane expansion connector. It weighs 0.23kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This safe I/O module is certified by RCM, CULus and TÃV. It can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PLe conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL3 conforming to IEC 62061. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe output expansion module |
| Device short name | XPSMCM |
| Electrical Connection | Screw terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Input type | 2 digital external device monitoring |
| Output type | 2 safety outputs OSSD contactor/drive connection 2 configurable diagnostic connection |
| Discrete input type | Isolated |
| Discrete output type | PNP |
| Function of module | Monitoring safety actuators discrete output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power Consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Number of terminal blocks | 4 |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block 1 captive screw clamp terminals, removable terminal block |
| Load type | Resistive load |
| Group of channels | 2 dual channel load 400mA/output |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Discrete input voltage | 24 V DC |
| Discrete output voltage | 24 V DC |
| Discrete output current | 400 mA 100 mA |
| Output load | 60 Ohm |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 2 LEDs green/red OUT output status 2 LEDs yellow RST restart signal 2 LEDs yellow STATUS output status |
| Cable cross section | 0.0003â¦0.002 in² (0.2â¦1.5 mm²) - AWG 24...AWG 16 flexible without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.002 in² (0.25â¦1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0008â¦0.002 in² (0.5â¦1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel 0.0003â¦0.002 in² (0.2â¦1 mm²) - AWG 24...AWG 18 solid without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Depth | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Width | 4.5 in (114.5 mm) |
| Product Weight | 0.51 lb(US) (0.23 kg) |

This Modicon MCM safe speed monitoring module has 2 inputs for proximity switches (with terminal blocks for wiring) and is fitted with captive screw clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.23kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe speed monitoring module |
| Device short name | XPSMCM |
| Electrical Connection | Screw terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Discrete input voltage | 24 V DC |
| Function of module | Speed monitoring |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power Consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Type 4 IEC 61496-1 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Number of terminal blocks | 4 |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 2 LEDs yellow PROX proximity sensors connection status 2 LEDs yellow SH speed monitoring status |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block 1 captive screw clamp terminals, removable terminal block |
| Maximum input frequency | 5 kHz sensor |
| Sensor Type | Inductive proximity sensor |
| Electrical connection | 2 connectors RJ45 EIA/TIA-568-A |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) flexible without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) solid without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) flexible with cable end, without bezel 0.0003â¦0.002 in² (0.2â¦1.5 mm²) flexible without cable end 0.0004â¦0.002 in² (0.25â¦1 mm²) flexible with cable end, without bezel 0.0008â¦0.002 in² (0.5â¦1.5 mm²) flexible with cable end, with double bezel 0.0003â¦0.002 in² (0.2â¦1 mm²) solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Depth | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Width | 4.5 in (114.5 mm) |
| Product Weight | 0.51 lb(US) (0.23 kg) |

This Modicon MCM safe speed monitoring module has 2 HTL encoder inputs (with RJ45 connectors) and 2 proximity sensor inputs (connection via terminal) and is fitted with captive screw clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe speed monitoring module |
| Device short name | XPSMCM |
| Electrical Connection | Screw terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Discrete input voltage | 24 V DC |
| Function of module | Speed monitoring |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power Consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Type 4 IEC 61496-1 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Number of terminal blocks | 4 |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 2 LEDs yellow PROX proximity sensors connection status 2 LEDs yellow SH speed monitoring status 2 LEDs yellow ENC encoder connection status |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block 1 captive screw clamp terminals, removable terminal block |
| Maximum input frequency | 5 kHz sensor 300 kHz encoder HTL |
| Sensor Type | Inductive proximity sensor |
| Electrical connection | 2 connectors RJ45 EIA/TIA-568-A |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.002 in² (0.2â¦1.5 mm²) - AWG 24...AWG 16 flexible without cable end 0.0004â¦0.002 in² (0.25â¦1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel 0.0008â¦0.002 in² (0.5â¦1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel 0.0003â¦0.002 in² (0.2â¦1 mm²) - AWG 24...AWG 18 solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Depth | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Width | 4.5 in (114.5 mm) |
| Product Weight | 0.7 lb(US) (0.3 kg) |

This Modicon MCM safe input expansion module has 16 digital inputs, 4 test output and is fitted with captive spring clamp terminals. It is designed to monitor remotely your safe I/O. It provides 16 isolated digital inputs and 4 PNP test outputs for line control. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. This safe I/O module figures configurable filters and delays for each single input. This module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, input and output status). This safe I/O module is connected to the safety controller via the backplane expansion connector. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This safe I/O module is certified by RCM, CULus and TÃV. It can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PLe conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL3 conforming to IEC 62061. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe input expansion module |
| Device short name | XPSMCM |
| Electrical Connection | Spring terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Input type | 16 digital |
| Output type | 4 test line control |
| Discrete input type | Isolated |
| Discrete output type | PNP |
| Function of module | Monitoring safety detection discrete input Monitoring safety dialogue discrete input |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power Consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Number of terminal blocks | 6 |
| Connections - terminals | 1 spring clamp terminals, removable terminal block 2 spring clamp terminals, removable terminal block |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Discrete input voltage | 24 V DC |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 16 LEDs yellow IN input status |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0008â¦0.002 in² (0.5â¦1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Depth | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Width | 4.5 in (114.5 mm) |
| Product Weight | 0.55 lb(US) (0.25 kg) |

This Modicon MCM safe RS485 bus expansion module for remote extension has 2-channel transmitter/receiver network connection and is fitted with captive spring clamp terminals. It enables the connection of modular safety controllers type XPSMCMCP0802 and XPSMCMC10804 with the expansion modules placed at distances up to 50m (164ft.) using RS485 shielded cables. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. Combined with safe RS485 bus expansion module type XPSMCMCO0000S2, It allows to create up to 6 decentralized I/O islands. This module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors). This safe bus expansion module is connected to other I/O modules via the backplane expansion connector, and uses a RS485 serial interface shielded cable to connect to safe RS485 bus expansion module and create decentralized I/O islands. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring up to five decentralized safety related islands with a distance of 50 meters (164.04 ft) between each island on a single Safety controller CPU. Embedding a safe communication between decentralized I/Oâs. The safe RS485 bus expansion module Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe RS485 bus expansion module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon MCM |
| Product or Component Type | Safe communication expansion module |
| Device short name | XPSMCM |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power dissipation in W | 3 W |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 Can reach SILCL 3 IEC 62061 |
| Quality labels | CE |
| Range Compatibility | Preventa XPSMCM |
| Connector type | 4 ways RS485 |
| Number of port | 2 |
| Communication Port Protocol | RS485 |
| Current Consumption | 0.125 mA |
| Maximum cable distance between devices | 164.04 ft (50 m) |
| Local signalling | LED green PWR power ON LED green RUN operating LED red E IN internal error LED red E EX external error |
| Connections - terminals | 4 spring clamp terminals, removable terminal block |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0008â¦0.002 in² (0.5â¦1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Depth | 4.5 in (114.5 mm) |
| Product Weight | 0.7 lb(US) (0.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Twido |
| Product or component type | Discrete input module |
| Discrete input number | 16 |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| I/O connection | HE-10 connector |
| Number of common point | 1 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Input voltage limits | 20.4...28.8 V |
| Discrete input logic | Sink or source |
| Discrete input current | 5 mA |
| Input impedance | 4.4 kOhm |
| Filter time | 8 ms at state 0 8 ms at state 1 |
| Insulation between channel and internal logic | 1500 Vrms for 1 min (by photocoupler) |
| Current consumption | 35 mA at 5 V DC at state 1 for all inputs 5 mA at 5 V DC at state 0 for all inputs |
| Marking | CE |
| Product weight | 0.065 kg |

This Modicon MCM standard ("non-safe") communication module has one Universal Serial Bus connection with a Mini USB connector. It is designed to monitor remotely your safety system with the commonly used Universal Serial Bus protocol, without additional gateways. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The non-safe communication modules are designed for diagnostics connection and data communication purposes to machine field bus or network systems. Its transmission rate is 12Mbit/s. This communication module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. The maximum cable distance between two devices is 5m. This Modicon MCM standard ("non-safe") communication module is certified by RCM, CULus and TÃV. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Modicon MCM |
| Product or component type | Non-safe communication module |
| Device short name | XPSMCM |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power dissipation in W | 3 W |
| Quality labels | CE |
| Range compatibility | Preventa XPSMCM |
| Connector type | mini B USB |
| Number of port | 1 |
| Method of access | Server |
| Transmission rate | 12 Mbit/s |
| Communication port protocol | USB |
| Current consumption | 0.125 mA |
| Maximum cable distance between devices | 5 m |
| Local signalling | LED green with CONNECT marking for operating |
| Connections - terminals | 2 spring clamp terminals, removable terminal block |
| Cable cross section | 0.2â¦2.5 mm² - AWG 24...AWG 14 flexible cablewithout cable end 0.25â¦2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, with bezel 0.25â¦2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, without bezel 0.2â¦2.5 mm² - AWG 24...AWG 14 solid cablewithout cable end 0.5â¦1 mm² - AWG 20...AWG 18 flexible cablewith cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail conforming to EN 50022 |
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Product weight | 0.3 kg |

This Modicon MCM safe output expansion module has 4 start/restart interlock inputs, 4 output OSSD pairs and 4 status outputs and is fitted with captive screw clamp terminals. It is designed to monitor remotely your safe I/O. It is furnished with screw clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. This safe I/O module figures configurable filters and delays for each single input, configurable output activation and de-activation delays, independent control of pairs of outputs, and configurable diagnostic output signals. This module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, input and output status). This safe I/O module is connected to the safety controller via the backplane expansion connector. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This safe I/O module is certified by RCM, CULus and TÃV. It can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PLe conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL3 conforming to IEC 62061. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe output expansion module |
| Device short name | XPSMCM |
| Electrical Connection | Screw terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Input type | 4 digital external device monitoring |
| Output type | 4 safety outputs OSSD contactor/drive connection 4 configurable diagnostic connection |
| Discrete input type | Isolated |
| Discrete output type | PNP |
| Function of module | Monitoring safety actuators discrete output |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power Consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Number of terminal blocks | 6 |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block 1 captive screw clamp terminals, removable terminal block |
| Load type | Resistive load |
| Group of channels | 4 dual channel load 400mA/output |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Discrete input voltage | 24 V DC |
| Discrete output voltage | 24 V DC |
| Discrete output current | 400 mA 100 mA |
| Output load | 60 Ohm |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 4 LEDs green/red OUT output status 4 LEDs yellow RST restart signal 4 LEDs yellow STATUS output status |
| Cable cross section | 0.0003â¦0.002 in² (0.2â¦1.5 mm²) - AWG 24...AWG 16 flexible without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.002 in² (0.25â¦1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0008â¦0.002 in² (0.5â¦1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel 0.0003â¦0.002 in² (0.2â¦1 mm²) - AWG 24...AWG 18 solid without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Depth | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Width | 4.5 in (114.5 mm) |
| Product Weight | 0.55 lb(US) (0.25 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Lexium 32i |
| Product or Component Type | Connector module |
| Accessory / separate part category | Connection accessories |
| Electrical Connection | Industrial connector |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product compatibility | Drive control unit LXM32i CANopen |
| Accessory / separate part destination | Motor BMI with drive control unit Lexium 32i |
| Range Compatibility | Lexium 32i |
| Communication interface | CANmotion CANopen DS402 |
| Input/output type | 2 discrete inputs |
| Discrete input logic | Sink |
| Safety Function | STO (safe torque off) |
| Product Weight | 0.481 lb(US) (0.218 kg) |

This Modicon MCM safe speed monitoring module has 1 Sin/Cos encoder input (with RJ45 connector) and 2 proximity sensor inputs (connection via terminal) and is fitted with captive screw clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.28kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÃD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe speed monitoring module |
| Device short name | XPSMCM |
| Electrical Connection | Screw terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Discrete input voltage | 24 V DC |
| Function of module | Speed monitoring |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power Consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Type 4 IEC 61496-1 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Number of terminal blocks | 4 |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 1 LED yellow ENC encoder connection status 2 LEDs yellow PROX proximity sensors connection status 2 LEDs yellow SH speed monitoring status |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block 1 captive screw clamp terminals, removable terminal block |
| Maximum input frequency | 5 kHz sensor 500 kHz encoder SinCos |
| Sensor Type | Inductive proximity sensor |
| Electrical connection | 1 connector RJ45 EIA/TIA-568-A |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.002 in² (0.2â¦1.5 mm²) - AWG 24...AWG 16 flexible without cable end 0.0004â¦0.002 in² (0.25â¦1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel 0.0008â¦0.002 in² (0.5â¦1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel 0.0003â¦0.002 in² (0.2â¦1 mm²) - AWG 24...AWG 18 solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Depth | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Width | 4.5 in (114.5 mm) |
| Product Weight | 0.62 lb(US) (0.28 kg) |

This Modicon MCM safe input expansion module has 12 digital inputs, 8 test outputs for 4 wires safety mats and is fitted with captive spring clamp terminals. It is designed to monitor remotely your safe I/O. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. This safe I/O module figures configurable filters and delays for each single input, configurable output activation and de-activation delays, independent control of pairs of outputs, and configurable diagnostic output signals. This module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, input and output status). This safe I/O module is connected to the safety controller via the backplane expansion connector. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This safe I/O module is certified by RCM, CULus and TÃV. It can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PLe conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL3 conforming to IEC 62061. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Safe input expansion module |
| Device short name | XPSMCM |
| Electrical Connection | Spring terminal |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
| Input type | 12 digital |
| Output type | 8 test line control |
| Discrete input type | PNP |
| Discrete output type | PNP |
| Function of module | Safety mat monitoring discrete input |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power Consumption in W | 3 W |
| Power dissipation in W | 3 W |
| Integrated connection type | Backplane expansion bus |
| Number of terminal blocks | 6 |
| Connections - terminals | 1 spring clamp terminals, removable terminal block 2 spring clamp terminals, removable terminal block |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061 |
| Quality labels | CE |
| Discrete input voltage | 24 V DC |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 12 LEDs yellow IN input status |
| Cable cross section | 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0008â¦0.002 in² (0.5â¦1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Depth | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Width | 4.5 in (114.5 mm) |
| Product Weight | 0.55 lb(US) (0.25 kg) |

This Modicon MCM standard ("non-safe") communication module has one Universal Serial Bus connection with a Mini USB connector. It is designed to monitor remotely your safety system with the commonly used Universal Serial Bus protocol, without additional gateways. It is furnished with screw clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The non-safe communication modules are designed for diagnostics connection and data communication purposes to machine field bus or network systems. Its transmission rate is 12Mbit/s. This communication module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. The maximum cable distance between two devices is 5m. This Modicon MCM standard ("non-safe") communication module is certified by RCM, CULus and TÃV. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon MCM |
| Product or Component Type | Non-safe communication module |
| Device short name | XPSMCM |
| [Us] rated supply voltage | 24 V - 20...20 % DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power dissipation in W | 3 W |
| Quality labels | CE |
| Range Compatibility | Preventa XPSMCM |
| Connector type | mini B USB |
| Number of port | 1 |
| Method of access | Server |
| Transmission rate | 12 Mbit/s |
| Communication Port Protocol | USB |
| Current Consumption | 0.125 mA |
| Maximum cable distance between devices | 16.4 ft (5 m) |
| Local signalling | LED green CONNECT operating |
| Connections - terminals | 2 captive screw clamp terminals, removable terminal block |
| Cable cross section | 0.0003â¦0.002 in² (0.2â¦1.5 mm²) - AWG 24...AWG 16 flexible without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004â¦0.002 in² (0.25â¦1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004â¦0.004 in² (0.25â¦2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0008â¦0.002 in² (0.5â¦1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel 0.0003â¦0.002 in² (0.2â¦1 mm²) - AWG 24...AWG 18 solid without cable end 0.0003â¦0.004 in² (0.2â¦2.5 mm²) - AWG 24...AWG 14 solid without cable end |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (99 mm) |
| Depth | 4.5 in (114.5 mm) |
| Product Weight | 0.7 lb(US) (0.3 kg) |