| Product | |
| Article Number (Market Facing Number) | 3TK28231CB30 | 3TK28231CB30 |
| Product Description | SIRIUS safety relay with relay enabling circuits (EC) 24 V AC/DC, 22.5 mm Screw terminal EC instantaneous: 2 NO EC delayed: 0 NO SC: 0 NC monitored start Basic device Maximum achieved SIL: 3, PL: e |
| Product family | Not available |
| Product Lifecycle (PLM) | PM490:Start of final year of support |
| Additional Product Information | |
| EAN | 4011209380660 |
| UPC | 754554482910 |
| Commodity Code | 85364900 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Product Group | 5837 |
| Group Code | R711 |
| Country of origin | Germany |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 0.538 lb |
| Package size unit of measure | Inch |
| Packaging Quantity | 1 |

| Product | |
| Article Number (Market Facing Number) | 3SK11211AB40 | 3SK11211AB40 |
| Product Description | |
| Product family | SIRIUS 3SK1 Advanced basic units |
| Product Lifecycle (PLM) | PM300:Active Product |
| Additional Product Information | |
| EAN | 4011209913585 |
| UPC | Not available |
| Commodity Code | 85371098 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Product Group | 3761 |
| Group Code | R711 |
| Country of origin | Germany |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 0.595 lb |
| Package size unit of measure | in |
| Packaging Quantity | 1 |

| Product | |
| Article Number (Market Facing Number) | 6GT28012BA10 | 6GT28012BA10 |
| Product Description | SIMATIC RF300; Reader RF340R (GEN2); RS422 interface (3964R); IP67, -25 to +70 °C, 75x 75x 41 mm with integrated antenna . |
| Product family | RF340R |
| Product Lifecycle (PLM) | PM300:Active Product |
| Additional Product Information | |
| EAN | 4047622417959 |
| UPC | 804766348686 |
| Commodity Code | 84719000 |
| LKZ_FDB/ CatalogID | ID10.M |
| Product Group | 9471 |
| Group Code | R322 |
| Country of origin | Germany |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 0.661 lb |
| Package size unit of measure | Inch |
| Packaging Quantity | 1 |

| Product | |
| Article Number (Market Facing Number) | 3TK28212CB30 | 3TK28212CB30 |
| Product Description | SIRIUS safety relay with relay enabling circuits (EC) 24 V AC/DC, 22.5 mm Spring-type terminal EC instantaneous: 3 NO EC delayed: 0 NO SC: 1NC Autostart/manual start Basic device Maximum achieved SIL: 1, PL: c as expansion unit up to maximum achieved SIL: 3, PL: e |
| Product family | Not available |
| Product Lifecycle (PLM) | PM490:Start of final year of support |
| Additional Product Information | |
| EAN | 4011209445314 |
| UPC | 754554653358 |
| Commodity Code | 85364900 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Product Group | 5837 |
| Group Code | R711 |
| Country of origin | Germany |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 0.529 lb |
| Package size unit of measure | Inch |
| Packaging Quantity | 1 |

| Product | |
| Article Number (Market Facing Number) | 7ML11061BA200A | 7ML11061BA200A |
| Product Description | EchoMax XRS-5 Ultrasonic level transducer: continuous, non-contact, 8 m (26 ft) range, for liquids and slurries. Mounting thread: 1" NPT (Taper), ANSI/ASME B1.20.1 Cable length: 10 m (32.81 ft) Facing: Standard (CSM rubber) Approvals: CSA Class I, Div. 2, Groups A, B, C, D; CSA Class II, Div. 1, Groups E, F, G; FM Class I, Zone 1, AEx m IIC, T6; FM Class II, III, Div. 1, Groups E, F, G T6; ATEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; ATEX II 2GD Ex tb IIIC T85°C Db; UKEX II 2GD Ex mb IIC T6 Gb, Ta = -20°C to +65°C; UKEX II 2GD Ex tb IIIC T85°C Db; IECEx Ex mb IIC T6 Gb, Ta = -20°C to +65°C; IECEx Ex tb IIIC T85°C Db; INMETRO Ex mb IIC T6 Gb, IP66/IP68, -20°C ≤ Ta ≤ +65°C; INMETRO Ex tb IIIC T85°C Db, IP66/IP68; CE, UKCA, RCM, KC, EAC Ex . . Flange: Without mounting flange |
| Product family | EchoMax XRS-5 |
| Product Lifecycle (PLM) | PM300:Active Product |
| Additional Product Information | |
| EAN | 4019169849524 |
| UPC | Not available |
| Commodity Code | 9032900000 |
| LKZ_FDB/ CatalogID | FI01-4 |
| Product Group | 4710 |
| Group Code | R3P0 |
| Country of origin | Canada |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 3.307 lb |
| Package size unit of measure | Inch |
| Packaging Quantity | 1 |

motor mechanism, MT 400-630, Compact NSX400/630, PowerPact Multistandard L, 220 to 240 VAC 50/60 Hz, 208 to 277 VAC 60 Hz

Harmony XVB, Audible unit for modular tower lights, plastic, �70, buzzer, continuous or intermitten tone,70... 90 dB, 12...48 V AC/DC

Time delay auxiliary contact block, TeSys D, 1NO + 1NC, on delay 0.3-3 s, front mounting, screw terminals

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon Premium Automation platform |
| Product or Component Type | Discrete output module |
| Discrete output number | 32 |
| Discrete output type | Solid state protected |
| Discrete output voltage | 24 V DC positive EN/IEC 61131-2 19...30 V |
Complementary
| Characteristic | Value(s) |
|---|---|
| Current per channel | 0.1 A |
| Maximum current per module | 3.2 A |
| Maximum leakage current | 0.1 mA 30 V |
| Maximum tungsten load | 1.2 W |
| [Ures] residual voltage | 1.5 V |
| Response time | 1.2 ms |
| Paralleling of outputs | Yes : 3 maximum |
| Output overvoltage protection | By transil diode |
| Reverse polarity protection | Reverse mounted diode |
| Output overload protection | Automatic trip |
| Short-circuit protection | Automatic trip |
| Minimum load impedance | 220 W at state 1 |
| isalotion resistance | > 10 MOhm 500 V |
| Power dissipation | (1.6 W + 0.1 W x No of outputs) |
| Product Compatibility | Dial and Power |
| Marking | CE |
| Electrical connection | 2 connectors HE-10 |
| Current consumption | 140 mA 5 V DC |
| Module format | Standard |
| Product Weight | 0.7 lb(US) (0.3 kg) |

The PowerLogic PM8000 series meters are compact, cost-effective multifunction power meters that will help you ensure reliability and efficiency of your power-critical facility. They reveal and provide understanding of complex power quality conditions enabling action to be taken to mitigate any issue. The PowerLogic PM8000 series meters have the versatility to perform nearly any job you need a meter to do, wherever you need it! The modular, flexible ION technology architecture enables a simple, building block approach for customizing each meter to any application. With patented Disturbance Direction Detection, revenue grade accuracy, multiple communication ports, onboard power quality analysis, web interface and a color graphical display. Certified by third party labs for energy accuracy (IEC 62052-11, IEC 62052-22, IEC 62052-24) and power quality (IEC 62586-2, IEC 61000-4-30 Class S). The PowerLogic PM8000 series provides data quality confidence you can count on. Cybersecurity features include secure protocols (HTTPS, SFTP), security event logging, Syslog protocol. Ability to enable/disable communication ports, and 50 user configurable accounts. With 512 MB of memory to support 50 data logs, 50+ user-definable alarms, waveform captures, 1/2 cycle RMS logging, custom web pages, min/max logs, energy trends, and Time of Use. The ability to timestamp events to +/-1 ms utilizing time synchronization method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function. 3 digital inputs and one digital output, plus the ability to add up to 4 option modules. I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs. Wide control power range of 90-415 VAC / 110-415 VDC. Operating environment of -25 to +70C; Humidity rating of 5% to 95%; Altitude up to 3000 m. DIN rail mounting with remote display.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | PowerLogic PM8000 |
| Product or Component Type | Power meter |
| Device short name | PM8244 |
| Market segment | Buildings large building cost management: billing: sub feeder Buildings small building network management: main incomer Buildings medium building network management: main incomer Buildings large building network management: main incomer Buildings large building network management: sub feeder Buildings multi-site network management: main incomer Buildings multi-site network management: sub feeder Data center network management: main incomer Data center network management: sub feeder Healthcare network management: main incomer Healthcare network management: sub feeder Industry network management: main incomer Industry network management: sub feeder Utility: sub feeder |
| model type | Standard |
Complementary
| Characteristic | Value(s) |
|---|---|
| Power quality analysis | EN 50160 2010 compliance report IEEE 519 2014 compliance report IEC 61000-4-30 class S power quality measurement up to the 63rd harmonic harmonic distortion waveform capture voltage sag and swell detection programmablity (logic and math functions) IEC 62586 power quality monitoring disturbance direction detection rapid voltage change |
| Device Application | WAGES metering Power monitoring |
| Type of measurement | Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms |
| supply voltage | 90...415 V AC 45...65 Hz +/- 10 % 110...415 V DC +/- 10 % |
| Network Frequency | 50 Hz 60 Hz |
| Line Rated Current | 10 A 5 A 1 A |
| Poles description | 3P 1P + N 3P + N |
| Power Consumption in VA | 16 VA 230 V AC |
| Display Type | Remote LCD display |
| Display Resolution | 320 x 240 pixels QVGA |
| Sampling rate | 256 samples/cycle |
| Measurement current | 50â¦10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm) Current (impedance 0.3 mOhm) |
| Measurement voltage | 57â¦400 V AC 42...69 Hz between phase and neutral 100â¦690 V AC 42...69 Hz between phases |
| Frequency measurement range | 42â¦69 Hz |
| Number of inputs | 3 digital 30 V AC 3 digital 60 V DC |
| Measurement accuracy | Current +/- 0.1 % Voltage +/- 0.1 % Active energy +/- 0.2 % |
| Accuracy class | Class 0.2S active energy IEC 62053-22 Class 0.2 active energy ANSI C12.20 Class 0.2 active power IEC 61557-12 Class 0.5S reactive energy IEC 62053-24 Class 0.5 power factor IEC 61557-12 Class 0.2 voltage IEC 61557-12 Class 0.2 current IEC 61557-12 |
| Number of Outputs | 1 pulse |
| Information displayed | Voltage Current Frequency Power Energy consumption Harmonic distortion |
| Communication port protocol | Modbus RTU 115 kbauds - 2-wire ION 115 kbauds - 2-wire DNP3 IEC 61850 Modbus TCP/IP Ethernet Modbus TCP/IP daisy chain 10/100 Mbit/s RSTP 801.1d 2004 |
| Communication port support | ETHERNET Screw terminal block RS485 |
| Communication Network Type | IPv6 (internet protocol) |
| Data recording | Sequence of event recording Event logs Min/max of instantaneous values Harmonics logs Alarm logs GPS synchronisation Waveform logs Data logs Time stamping Trending/forecasting Sag and swell logs 50 data recorders |
| Memory capacity | 512 MB |
| Web services | Customizable home page File upload/download via FTP File upload/download via SFTP Web server Alarm notification by e-mail Viewing of captured waveform (FTP) Viewing of captured waveform (web) HTTPS server |
| Communication Service | SMTP e-mail notification RSTP support NTP time synchronization DHCP PTP time synchronization |
| Cybersecurity | Password protection Syslog protocol support Port hardening Robust security logs Enable/disable communication ports |
| Mounting Mode | Flush-mounted Clip-on |
| Mounting support | DIN rail meter device Framework remote display |
| Provided Equipment | Remote display |
| Installation category | III |
| Safety Construction | III400â¦690 V conforming to IEC 61010-1:ed. 3 III400â¦690 V conforming to EN 61010-1:ed. 3 III347â¦600 V conforming to UL 61010-1:ed. 3 III347â¦600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Standards | IEC 62053-22 IEC 62053-24 IEC 62052-11 IEC 61557-12 IEEE 1588 IEC 62586-2 IEC 61326-1 |
| Product certifications | CE CULus N998 |
| Width | 3.6 in (90.5 mm) |
| Depth | 3.6 in (90.8 mm) |
| Height | 3.6 in (90.5 mm) |
| Product Weight | 18.6 oz (528 g) |

This product is part of the Modicon M221 range, an offer of programmable logic controllers for hardwired architectures. This logic controller provides 8 discrete, 4 fast inputs, 8 transistor, 2 fast outputs with PNP transistor output with 10bit resolution. It is a Modicon logic controller with a rated supply/output voltage of 24V DC, an output current of 0.5A with sink or source input logic and positive output logic. This product requires minimal installation and offers tremendous versatility. Integrated connections are USB port with mini B USB 2.0 connector, non isolated serial link serial 1 with RJ45 connector and RS485 interface and non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface. It is a Modicon M221 controller with 256kB for user application and data RAM, internal variables RAM, 256kB built-in flash memory and a SD card memory capacity of 2GB. It is an IP20 rated product. Its dimensions are 70mm (Width) x 70mm (Depth) x 90mm (Height). It weighs 0.264kg. This product is certified by CE, IACS E10, CSA, RCM, LR, ABS, DNV-GL, EAC and CULus. It meets EN/IEC 61010-2-201, EN/IEC 61131-2 and EN/IEC 60664-1 standards. It supports DIN rail mount. Achieve benchmark performance while increasing profitability with the Modicon M221 through intuitive machine programming with SoMachine Basic, ready-to-use applications and function blocks
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon M221 |
| Product or Component Type | Logic controller |
| [Us] rated supply voltage | 24 V DC |
| Discrete input number | 8, discrete input 4 fast input IEC 61131-2 Type 1 |
| Analogue input number | 2 0...10 V |
| Discrete output type | Transistor |
| Discrete output number | 8 transistor 2 fast output |
| Discrete output voltage | 24 V DC |
| Discrete output current | 0.5 A |
Complementary
| Characteristic | Value(s) |
|---|---|
| Discrete I/O number | 16 |
| Maximum number of I/O expansion module | 7 (local I/O-Architecture) 14 (remote I/O-Architecture) |
| Supply voltage limits | 20.4â¦28.8 V |
| Inrush current | 35 A |
| Maximum power consumption in W | 22 W 24 V with max number of I/O expansion module) 3.2 W 24 V without I/O expansion module) |
| Power supply output current | 0.52 A 5 V expansion bus 0.49 A 24 V expansion bus |
| Discrete input logic | Sink or source (positive/negative) |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| Analogue input resolution | 10 bits |
| LSB value | 10 mV |
| Conversion time | 1 ms per channel + 1 controller cycle time analog input |
| Permitted overload on inputs | +/- 30 V DC 5 min maximum)analog input +/- 13 V DC permanent)analog input |
| Voltage state 1 guaranteed | >= 15 V input |
| Voltage state 0 guaranteed | <= 5 V input |
| Discrete input current | 7 mA discrete input 5 mA fast input |
| Input impedance | 100 kOhm analog input 3.4 kOhm input 4.9 kOhm fast input |
| Response time | 35 µs turn-off, I2...I5 input 5 µs turn-on, I0, I1, I6, I7 fast input 35 µs turn-on, other terminals input 5 µs turn-off, I0, I1, I6, I7 fast input 100 µs turn-off, other terminals input 5 µs turn-on, turn-off, Q0...Q1 output 50 µs turn-on, turn-off, Q2...Q3 output 300 µs turn-on, turn-off, other terminals output |
| Configurable filtering time | 0 ms input 3 ms input 12 ms input |
| Discrete output logic | Positive logic (source) |
| Maximum current per output common | 4 A |
| Output frequency | 100 kHz fast output (PWM/PLS mode) Q0...Q1 5 kHz output Q2...Q3 0.1 kHz output Q4...Q6 |
| Absolute accuracy error | +/- 1 % of full scale analog input |
| Maximum leakage current | 0.1 mA transistor output |
| Maximum voltage drop | <1 V |
| Mechanical durability | 20000000 cycles transistor output |
| Maximum tungsten load | <12 W output and fast output |
| Protection type | Short-circuit and overload protection with automatic reset Short-circuit protection on output Overload and short-circuit protection 1 A |
| Reset time | 1 s automatic reset |
| Memory capacity | 256 kB user application and data RAM 10000 instructions 256 kB internal variables RAM |
| Data backed up | 256 kB built-in flash memory backup of application and data |
| Data storage equipment | 2 GB SD card optional) |
| Battery type | BR2032 or CR2032X lithium non-rechargeable |
| Backup time | 1 year 77 °F (25 °C) by interruption of power supply) |
| Execution time for 1 KInstruction | 0.3 ms event and periodic task 0.7 ms other instruction |
| Execution time per instruction | 0.2 µs Boolean |
| Exct time for event task | 60 µs response time |
| Application structure | 8 interrupt tasks 1 cyclic auxiliary task 1 configurable freewheeling/cyclic master task |
| Maximum size of object areas | 8000 %MW memory words 255 %C counters 512 %KW constant words 255 %TM timers 512 %M memory bits |
| Realtime clock | With |
| Clock drift | <= 30 s/month 77 °F (25 °C) |
| Regulation loop | Adjustable PID regulator up to 14 simultaneous loops |
| Positioning functions | PTO 2 pulse/direction 100 kHz) PTO 1 CW/CCW 100 kHz) |
| Function Available | Frequency generator PWM PLS |
| Counting input number | 4 fast input (HSC mode) 100 kHz 32 bits |
| counter function | Single phase Pulse/direction A/B |
| Integrated connection type | USB port mini B USB 2.0 Non isolated serial link serial 1 RJ45 RS485 Non isolated serial link serial 2 RJ45 RS232/RS485 |
| Supply | Serial 1)serial link supply 5 V, <200 mA |
| Transmission rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232 480 Mbit/s USB |
| Communication port protocol | USB port USB - SoMachine-Network Non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network |
| Communication Service | Modbus master Modbus slave |
| Local signalling | 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED (green) for SL2 1 LED per channel (green) for I/O state |
| Electrical connection | terminal block, 3 for connecting the 24 V DC power supply connector, 4 for analogue inputs Mini B USB 2.0 connector for a programming terminal removable screw terminal block, 10 for inputs removable screw terminal block, 11 for outputs |
| Maximum cable distance between devices | Shielded cable <32.8 ft (10 m) fast input Unshielded cable <98.4 ft (30 m) output Unshielded cable <98.4 ft (30 m) digital input Unshielded cable <3.3 ft (1 m) analog input Shielded cable <9.8 ft (3 m) fast output |
| Insulation | Between input and internal logic 500 V AC Between fast input and internal logic 500 V AC Non-insulated between inputs Between output and internal logic 500 V AC Between output groups 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs Between fast output and internal logic 500 V AC Non-insulated between outputs |
| Marking | CE |
| Mounting support | Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 plate or panel with fixing kit |
| Height | 3.5 in (90 mm) |
| Depth | 2.8 in (70 mm) |
| Width | 2.8 in (70 mm) |
| Product Weight | 0.582 lb(US) (0.264 kg) |


This Lexium 32 Servo Drive Works At A Rated Supply Voltage From 208V Ac To 480V Ac. It Can Feed 3-Phase Synchronous Motors Bmh Or Bsh, Its Continuous Output Current Is 10A At 8Khz. The Compact Size Of The Servo Drive And Associated Servo Motor Provides Maximum Power In The Minimum Space. This Servo Drive Is Specifically Designed For Industrial Machines. It Offers High Performance, Power And Simplicity Of Use In Motion Control Applications. It Complies With International Standards Iec/En 61800-5-1, Iec/En 61800-3, And Is Ul And Csa And Is Ul And Csa Certified And Ce Marked. It Has Been Developed To Meet The Requirements Of Directives Regarding Protection Of The Environment (Rohs).

| Product | |
| Article Number (Market Facing Number) | 3RP25601SW30 | 3RP25601SW30 |
| Product Description | time relay, electronic with star-delta function 1-20 s, delay time 30-600 s 3 NO contacts with common potential 12-240 V AC/DC at 50/60 Hz AC screw terminal 0.85 ...1.1 Us |
| Product family | SIRIUS 3RP25 timing relays 17.5 mm and 22.5 mm |
| Product Lifecycle (PLM) | PM300:Active Product |
| Additional Product Information | |
| EAN | 4011209943834 |
| UPC | 887621915162 |
| Commodity Code | 85364900 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Product Group | 4952 |
| Group Code | R711 |
| Country of origin | Germany |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 0.381 lb |
| Package size unit of measure | in |
| Packaging Quantity | 1 |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony XBTGT |
| Product or Component Type | Advanced touchscreen panel |
| Display Type | Backlit colour TFT LCD |
| Display colour | 256 colours |
| Display Resolution | 320 x 240 pixels QVGA |
| Display size | 3.8 inch |
| Software Type | Configuration software |
| Software Designation | Vijeo Designer |
| Operating System | Harmony |
| Processor name | CPU RISC |
| Processor frequency | 200 MHz |
| Memory description | 512 KB SRAM back up of data lithium battery 32 MB flash EPROM application memory |
| Integrated connection type | removable screw terminal block power supply RJ45 Ethernet TCP/IP RJ45 COM1 serial link RS232C/RS485 <= 115.2 kbits/s USB type A master port (V1.1) Modicon M340 terminal port communication |
| Resistance to electrostatic discharge | 6 kV IEC 61000-4-2 level 3 |
| Cut-out dimensions | 118 (+ 1/- 0) x 92.5 (+ 1/- 0) mm |
Complementary
| Characteristic | Value(s) |
|---|---|
| Touch panel | Analogue |
| Backlight lifespan | 40000 hours |
| Brightness | 16 levels |
| Character font | Korean ASCII Chinese (simplified Chinese) Japanese (ANK, Kanji) Taiwanese (traditional Chinese) |
| [Us] rated supply voltage | 24 V DC |
| Supply | External source |
| Supply voltage limits | 19.2â¦28.8 V |
| Inrush current | 60 A |
| Power Consumption in W | 13 W |
| Local signalling | 1 LED (green) for normal operation |
| Number of pages | Limited by internal memory capacity |
| Downloadable protocols | Telemecanique Modicon Modbus TCP Telemecanique Modicon Modbus Mitsubishi Melsec third party protocols Omron Sysmac third party protocols Rockwell Automation Allen-Bradley third party protocols Siemens Simatic third party protocols Telemecanique Modicon Uni-TE |
| Realtime clock | Built-in |
| Port Ethernet | 100BASE-TX |
| Product mounting | Flush mounting |
| Fixing Mode | By 4 screw clamps By 2 spring clips |
| Front material | PPT |
| Enclosure Material | PPT |
| Marking | CE |
| Width | 5.1 in (130 mm) |
| Height | 4.09 in (104 mm) |
| Depth | 1.6 in (40 mm) |
| Product Weight | 2.2 lb(US) (1 kg) |