Filters

Measurement Sensors

719 products

Showing 193 - 216 of 719 products

Showing 193 - 216 of 719 products
View
keyence Stock Image
Keyence CL-C10 Keyence
Sale price 8,846.00 kr
Only 1 unit left

Specifications

Model

CL-C10

Length

10 m 32.8'

Weight

850 g

keyence Stock Image
Keyence CL-AC2 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-AC2

Length

2 m 6.6'

Weight

400 g

keyence Stock Image
Keyence CL-AC1 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-AC1

Length

1 m 3.3'

Weight

200 g

keyence Stock Image
Keyence CL-V050N Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-V050N

Type

Optical unit

Head

CL-V050 *1

Reference distance

50 mm1.97"

Reference measurement range

Measurement range

±4 mm ±0.16"

Linearity

±1.4 μm ±0.000055" *2

High precision measurement range

Measurement range

±1.6 mm ±0.06"

Linearity

±1.3 μm ±0.000051" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø40 μm ø0.0016"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP40 degassed structure for vacuum environments *4

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 200°C -4 to 392°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Ultra-high-vacuum environments *5

Explosion-proof

performance

Head

None

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.015% of F.S./°C *6

Optical unit

0.015% of F.S./°C

Material

Head

SUS304

Optical unit

Polycarbonate

Weight

Head

Approx. 100 g 3.53 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 The enclosure rating is equivalent to IP50 when the included sticker is attached.
*5 Operation verification has been performed in environments of 10^-6 Pa.
*6 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-V050G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-V050G

Type

Optical unit

Head

CL-V050 *1

Reference distance

50 mm1.97"

Reference measurement range

Measurement range

±4 mm ±0.16"

Linearity

±1.25 μm ±0.000049" *2

High precision measurement range

Measurement range

±1.6 mm ±0.06"

Linearity

±1.15 μm ±0.000045" *2

Resolution

0.03 μm 0.000001" *3

Spot diameter

ø40 μm ø0.0016"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP40 degassed structure for vacuum environments *4

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 200°C -4 to 392°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Ultra-high-vacuum environments *5

Explosion-proof

performance

Head

None

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.015% of F.S./°C *6

Optical unit

0.015% of F.S./°C

Material

Head

SUS304

Optical unit

Polycarbonate

Weight

Head

Approx. 100 g 3.53 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 The enclosure rating is equivalent to IP50 when the included sticker is attached.
*5 Operation verification has been performed in environments of 10^-6 Pa.
*6 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-V020N Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-V020N

Type

Optical unit

Head

CL-V020 *1

Reference distance

20 mm 0.79"

Reference measurement range

Measurement range

±1.3 mm ±0.05"

Linearity

±0.45 μm ±0.000018" *2

High precision measurement range

Measurement range

±0.5 mm ±0.02"

Linearity

±0.38 μm ±0.000015" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø20 μm ø0.0008"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP40 degassed structure for vacuum environments *4

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 200°C -4 to 392°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Ultra-high-vacuum environments *5

Explosion-proof

performance

Head

None

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.013% of F.S./°C *6

Optical unit

0.015% of F.S./°C

Material

Head

SUS304

Optical unit

Polycarbonate

Weight

Head

Approx. 100 g 3.53 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 The enclosure rating is equivalent to IP50 when the included sticker is attached.
*5 Operation verification has been performed in environments of 10^-6 Pa.
*6 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-V020G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-V020G

Type

Optical unit

Head

CL-V020 *1

Reference distance

20 mm 0.79"

Reference measurement range

Measurement range

±1.3 mm ±0.05"

Linearity

±0.3 μm ±0.000012" *2

High precision measurement range

Measurement range

±0.5 mm ±0.02"

Linearity

±0.23 μm ±0.000009" *2

Resolution

0.01 μm *3

Spot diameter

ø20 μm ø0.0008"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP40 degassed structure for vacuum environments *4

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 200°C -4 to 392°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Ultra-high-vacuum environments *5

Explosion-proof

performance

Head

None

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.013% of F.S./°C *6

Optical unit

0.015% of F.S./°C

Material

Head

SUS304

Optical unit

Polycarbonate

Weight

Head

Approx. 100 g 3.53 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 The enclosure rating is equivalent to IP50 when the included sticker is attached.
*5 Operation verification has been performed in environments of 10^-6 Pa.
*6 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-S015N Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-S015N

Type

Optical unit

Head

CL-S015 *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.0 mm ±0.04"

Linearity

±0.35 μm ±0.000014" *2

High precision measurement range

Measurement range

-0.2 mm/-1.0 mm -0.01/-0.04"

Linearity

±0.25 μm ±0.000010" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø10 μm ø0.0004"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP50

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 70°C -4 to 158°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Vacuum environments

Explosion-proof

performance

Head

None

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.005% of F.S./°C *4

Optical unit

0.015% of F.S./°C

Material

Head

SUS303/304

Optical unit

Polycarbonate

Weight

Head

Approx. 350 g 12.36 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-S015G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-S015G

Type

Optical unit

Head

CL-S015 *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.0 mm ±0.04"

Linearity

±0.2 μm ±0.000008" *2

High precision measurement range

Measurement range

-0.2 mm/-1.0 mm -0.01/-0.04"

Linearity

±0.1 μm ±0.000004" *2

Resolution

0.003 μm *3

Spot diameter

ø10 μm ø0.0004"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP50

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 70°C -4 to 158°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Vacuum environments

Explosion-proof

performance

Head

None

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.005% of F.S./°C *4

Optical unit

0.015% of F.S./°C

Material

Head

SUS303/304

Optical unit

Polycarbonate

Weight

Head

Approx. 350 g 12.36 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-S015EXN Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-S015EXN

Type

Optical unit

Head

CL-S015EX *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.0 mm ±0.04"

Linearity

±0.35 μm ±0.000014" *2

High precision measurement range

Measurement range

-0.2 mm/-1.0 mm -0.01/-0.04"

Linearity

±0.25 μm ±0.000010" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø10 μm ø0.0004"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP50

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 70°C -4 to 158°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Vacuum environments

Explosion-proof

performance

Head

IECEx: Ex op is IIC T6 Ga
ATEX: II 1 G Ex op is IIC T6 Ga
NRTL/ACO: Class I, Zone 0, AEx op is IIC T6 Ga Class I, Division 1, Groups A, B, C, D, T6

Optical unit

IECEx: [Ex op is IIC T6 Ga]
ATEX: II (1) G [Ex op is IIC T6 Ga]
NRTL/ACO: Class I, Zone 0, [AEx op is IIC T6 Ga] Class I, Division 1, Groups A, B, C, D, T6

Zone/Division

Head

IECEx: Zone 0
ATEX: Zone 0
NRTL/ACO: Zone 0/Division 1

Optical unit

Do not install in a hazardous location (associated equipment)

Ambient temperature

Head

-20°C ≤ Ta ≤ 70°C -4°F ≤ Ta ≤ 158°F

Optical unit

0°C ≤ Ta ≤ 50°C 32°F ≤ Ta ≤ 122°F

Certification number

IECEx: IECEx CSAE 23.0033X
ATEX: CSANe 23ATEX1133X
NRTL/ACO: 23CA80171819X

Temperature characteristic

Head

0.005% of F.S./°C *4

Optical unit

0.015% of F.S./°C

Material

Head

SUS303/304

Optical unit

Polycarbonate

Weight

Head

Approx. 350 g 12.36 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-S015EXG Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-S015EXG

Type

Optical unit

Head

CL-S015EX *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.0 mm ±0.04"

Linearity

±0.2 μm ±0.000008" *2

High precision measurement range

Measurement range

-0.2 mm/-1.0 mm -0.01/-0.04"

Linearity

±0.1 μm ±0.000004" *2

Resolution

0.003 μm *3

Spot diameter

ø10 μm ø0.0004"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP50

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

-20 to 70°C -4 to 158°F

Optical unit

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

Vacuum environments

Explosion-proof

performance

Head

IECEx: Ex op is IIC T6 Ga
ATEX: II 1 G Ex op is IIC T6 Ga
NRTL/ACO: Class I, Zone 0, AEx op is IIC T6 Ga Class I, Division 1, Groups A, B, C, D, T6

Optical unit

IECEx: Ex op is IIC T6 Ga
ATEX: II (1) G [Ex op is IIC T6 Ga]
NRTL/ACO: Class I, Zone 0, [AEx op is IIC T6 Ga] Class I, Division 1, Groups A, B, C, D, T6

Zone/Division

Head

IECEx: Zone 0
ATEX: Zone 0
NRTL/ACO: Zone 0/Division 1

Optical unit

Do not install in a hazardous location (associated equipment)

Ambient temperature

Head

-20°C ≤ Ta ≤ 70°C -4°F ≤ Ta ≤ 158°F

Optical unit

0°C ≤ Ta ≤ 50°C 32°F ≤ Ta ≤ 122°F

Certification number

IECEx: IECEx CSAE 23.0033X
ATEX: CSANe 23ATEX1133X
NRTL/ACO: 23CA80171819X

Temperature characteristic

Head

0.005% of F.S./°C *4

Optical unit

0.015% of F.S./°C

Material

Head

SUS303/304

Optical unit

Polycarbonate

Weight

Head

Approx. 350 g 12.36 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-PT010N Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-PT010N

Type

Optical unit

Head

CL-PT010 *1

Reference distance

10 mm 0.39"

Reference measurement range

Measurement range

±0.3 mm ±0.01"

Linearity

±0.22 μm ±0.000009" *2

High precision measurement range

Measurement range

±0.15 mm ±0.01"

Linearity

±0.2 μm ±0.000008" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø3.5 μm ø0.000138"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP64 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

0 to 50°C 32 to 122°F

Optical unit

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

None

Explosion-proof

performance

Head

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.1% of F.S./°C *4

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 1100 g 2.43 lb

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*4 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-PT010G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-PT010G

Type

Optical unit

Head

CL-PT010 *1

Reference distance

10 mm 0.39"

Reference measurement range

Measurement range

±0.3 mm ±0.01"

Linearity

±0.11 μm ±0.000004" *2

High precision measurement range

Measurement range

±0.15 mm ±0.01"

Linearity

±0.09 μm ±0.000004" *3

Resolution

0.001 μm *4

Spot diameter

ø3.5 μm ø0.000138"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP64 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Operating ambient temperature

Head

0 to 50°C 32 to 122°F

Optical unit

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Vacuum

None

Explosion-proof

performance

Head

Optical unit

Zone/Division

Head

Optical unit

Ambient temperature

Head

Optical unit

Certification number

Temperature characteristic

Head

0.1% of F.S./°C *5

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 1100 g 2.43 lb

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface) .
*3 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*4 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).
*5 These figures are based on the case where a jig made of SUS303 (or SUS304) is fixed between the head and the object.

keyence Stock Image
Keyence CL-P150N Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-P150N

Type

Optical unit

Head

CL-P150 *1

Reference distance

150 mm 5.91"

Reference measurement range

Measurement range

±35 mm ±1.38"

Linearity

±5.65 μm ±0.000222" *2

High precision measurement range

Measurement range

±15 mm ±0.59"

Linearity

±4.65 μm ±0.000183" *2

Resolution

0.25 μm 0.000010"

Spot diameter

ø75 μm ø0.0030"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 380 g 13.41 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).

keyence Stock Image
Keyence CL-P150G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-P150G

Type

Optical unit

Head

CL-P150 *1

Reference distance

150 mm 5.91"

Reference measurement range

Measurement range

±35 mm ±1.38"

Linearity

±5.5 μm ±0.000217" *2

High precision measurement range

Measurement range

±15 mm ±0.59"

Linearity

±4.5 μm ±0.000177" *2

Resolution

0.1 μm 0.000004" *3

Spot diameter

ø75 μm ø0.0030"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 380 g 13.41 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).

keyence Stock Image
Keyence CL-P070N Keyence
Sale price 25,317.00 kr
Only 1 unit left

Specifications

Model

CL-P070N

Type

Optical unit

Head

CL-P070 *1

Reference distance

70 mm 2.76"

Reference measurement range

Measurement range

±10 mm ±0.39"

Linearity

±2.2 μm ±0.000087" *2

High precision measurement range

Measurement range

±3.0 mm ±0.12"

Linearity

±2.0 μm ±0.000079" *2

Resolution

0.25 μm 0.000010"

Spot diameter

ø50 μm ø0.0020"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 280 g 9.88 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).

keyence Stock Image
Keyence CL-P070G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-P070G

Type

Optical unit

Head

CL-P070 *1

Reference distance

70 mm 2.76"

Reference measurement range

Measurement range

±10 mm ±0.39"

Linearity

±2.0 μm ±0.000079" *2

High precision measurement range

Measurement range

±3.0 mm ±0.12"

Linearity

±1.9 μm ±0.000075" *2

Resolution

0.025 μm 0.000001" *3

Spot diameter

ø50 μm ø0.0020"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 280 g 9.88 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface) .
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).

Keyence Stock Image
Keyence CL-P030N Keyence
Sale price 20,270.00 kr
In stock, 11 units

Specifications

Model

CL-P030N

Type

Optical unit

Head

CL-P030 *1

Reference distance

30 mm 1.18"

Reference measurement range

Measurement range

±3.7 mm ±0.15"

Linearity

±0.94 μm ±0.000037" *2

High precision measurement range

Measurement range

±1.0 mm ±0.04"

Linearity

±0.72 μm ±0.000028" *2

Resolution

0.25 μm 0.000010"

Spot diameter

ø38 μm ø0.0015"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 200 g 7.06 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).

Keyence Stock Image
Keyence CA-E200LJ Keyence
Sale price 18,013.00 kr
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-86930 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-84384 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence CL-P030G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-P030G

Type

Optical unit

Head

CL-P030 *1

Reference distance

30 mm 1.18"

Reference measurement range

Measurement range

±3.7 mm ±0.15"

Linearity

±0.81 μm ±0.000032" *2

High precision measurement range

Measurement range

±1.0 mm ±0.04"

Linearity

±0.59 μm ±0.000023" *2

Resolution

0.015 μm 0.000001" *3

Spot diameter

ø38 μm ø0.0015"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 200 g 7.06 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface) .
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).

keyence Stock Image
Keyence CL-P015N Keyence
Sale price 58,401.00 kr
Only 2 units left

Specifications

Model

CL-P015N

Type

Optical unit

Head

CL-P015 *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.3 mm ±0.05"

Linearity

±0.49 μm ±0.000019" *2

High precision measurement range

Measurement range

±0.5 mm ±0.02"

Linearity

±0.41 μm ±0.000016" *2

Resolution

0.25 μm 0.000010"

Spot diameter

ø25 μm ø0.0010"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 180 g 6.35 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).

keyence Stock Image
Keyence CL-P015G Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-P015G

Type

Optical unit

Head

CL-P015 *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.3 mm ±0.05"

Linearity

±0.36 μm ±0.000014" *2

High precision measurement range

Measurement range

±0.5 mm ±0.02"

Linearity

±0.28 μm ±0.000011" *2

Resolution

0.003 μm *3

Spot diameter

ø25 μm ø0.0010"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 180 g 6.35 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface) .
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).

Recently viewed