keyence Stock Image
Keyence LK-H2 Keyence
Sale price 8,401.00 kr
Only 2 units left

Specifications

Model

LK-H2*1

Operating System

Windows 11 Pro
Windows 10 *2
Windows 7 (SP1 or later)*3
Windows Vista (SP2 or later)*4
Windows XP (SP3 or later)*5

CPU

Pentium III 1 GHz or higher (1.7 GHz or higher recommended)

Memory capacity

256 MB or more (1 GB or more recommended)

Available hard disk space

1 GB

Display

1024 x 768 pixels, 24-bit full color or better

PC interface

The PC must be equipped with one of these interfaces:
USB: Revision 2.0 HighSpeed (USB1.1 compatible full speed)*6
LAN: 100BASE-TX, 10BASE-T*7
RS-232C (serial port)

*1 Windows is a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries.
Pentium is a registered trademark of Intel Corporation.
*2 Compatible with each edition of Home, Pro, and Enterprise.
*3 Compatible with each edition of Home Premium, Professional and Ultimate.
*4 Editions supported: Ultimate, Business, Home Premium, Home Basic.
*5 Supports Professional and Home Edition.
*6 Does not support connection via a USB hub.
*7 Does not support connection via private LANs or routers. Use in a 1:1 or local connection.

keyence Stock Image
Keyence LK-DN100 Keyence
Sale price 32,016.00 kr
Only 4 units left

Specifications

Model

LK-DN100

Type

DeviceNet® communication unit dedicated to LK-G5000 Series

Network connection

Master unit

ODVA-certified master unit

Maximum trunk line cable length

Thick cable: 500 m 1640.4' (at transmission speed of 125 kbps)/250 m 820.21' (at 250 kbps)/
125 m 410.11' (at 500 kbps) Thin cable: 100 m 328.08' (at all transmission speed settings)

Communication protocol

DeviceNet®*1 compliant

Transmission speed

500 kbps, 250 kbps, 125 kbps

Device type

Generic

Transmission medium

Dedicated 5 cables (2 signal cables, 2 power supply cables, 1 shielding cable)

Communication type

I/O communication (Poll) Explicit message communication

Power supply

11 to 25 VDC

Current consumption

10 mA max. (when network power supply 24 V is applied)

Power supply

Power supply voltage

24 VDC ±10% (supplied from controller)

Maximum current consumption

200mA or less

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 300 g

*1 DeviceNet® is a registered trademark of ODVA (Open DeviceNet® Vendor Association).

keyence Stock Image
Keyence LK-CC100 Keyence
Sale price 23,214.00 kr
Only 1 unit left

Specifications

Model

LK-CC100

Type

CC-Link communication unit dedicated to LK-G5000 Series

Network connection

Supported CCLink version

Ver. 1.10 (Extended cyclic setting: Single) Ver. 2.00 (Extended cyclic setting: Double or more)*1*2

Master unit

CLPA-certified master unit (CC-Link Ver. 2.00/Ver. 1.10)

No. of occupied stations

1 to 4

Communication speed

156kbps、625kbps、2.5Mbps、5Mbps、10Mbps

Connection cable

Dedicated CC-Link cable supporting Ver. 1.10 (Shielded 3-core twisted-pair cable: OP-79426, OP-79427)

Maximum total cable extension length

156kbps…1200m、 625kbps…900m、 2.5Mbps…400m、 5Mbps…160m、 10Mbps…100m

Station type

Remote device station

Power supply

Power supply voltage

24 VDC ±10 % (supplied from controller)

Maximum current consumption

200mA or less

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 300 g

*1 The LK-G5000 Series supports the "extended cyclic transmission" and "station-to-station cable length relaxation" of CC-Link Ver. 2.00.
*2 CC-Link is a registered trademark of Mitsubishi Electric Corporation.

Keyence New Stock Image
Keyence LK-HA100 Keyence
Sale price 4,761.00 kr
Only 7 units left

Specifications

Model

LK-HA100

Separate type

Type

Head expansion unit

Sensor head compatibility

Compatible

No. of connectable sensor heads

1

Display interface

LED indicator

POWER ON, STABILITY, BRIGHT, DARK

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω

No. of analog outputs

1

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Power supply

Power supply voltage

24 VDC ±10 % (Supplied from the controller)

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 300 g

Keyence Stock Image
Keyence LK-HD1001 Keyence
Sale price 10,449.00 kr
Only 1 unit left

Specifications

Model

LK-HD1001

Type

LK-G5000 Series Touch Panel Display

Display panel

Display color

TFT color LCD

32,768 colors

Pixels

W 640 × H 480 pixels

Display area

W 170.9 × H 128.2 mm W 6.73' × H 5.04'

Displaypanel

Service life (normal temperature andhumidity)

Approx 50,000 hours

Backlight

Method

White LED

Duration

Approx 50,000 hours

Touch switch

Number of switches

40 × 30 per 1 image

Touchswitch

Method

Matrix resistance membrane mode

Operating force

0.98N or less

Life-span

More than one million times

Communication function

Available only with the LK-G5000 Series

Structure

Panel built-in type, IP65f equivalent dust-proof, waterjet-proof on only front panel

Power supply

Power supply voltage

24 VDC ±10%

Maximum current consumption

1 A or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)*1

Storage temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Storage relative humidity

35 to 85 % RH (No condensation)*1

Operating environment

No dust or corrosive gas

Vibration resistance

10 to 57 Hz, Double amplitude 0.3 mm 0.01"; 57 to 500 Hz, 2 G for 3 hours in each of the X, Y, and Z directions

Weight

Approx. 1,150 g

*1 When the ambient temperature is higher than 40 °C 104 °F, limit the absolute humidity to 85 % RH at 40 °C 104 °F.

LK-H157 Keyence
Keyence LK-H157 Keyence
Sale price 36,737.00 kr
Only 10 units left

Specifications

Model

LK-H157

Mounting mode

Diffuse reflective / Specular reflective*1

Reference distance

Diffuse reflective: 150 mm 5.91"
Specular reflective: 147.5 mm 5.81"

Measuring range

Diffuse reflective: ±40 mm ±1.57"
Specular reflective: -39.5 mm to +24.4 mm -1.56" to +0.96"*2

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

120 µm x 4,200 µm

Linearity

±0.02% of F.S. (F.S.= 80 mm 3.15")*3

Repeatability

0.25 µm*4

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S. (F.S.= 80 mm 3.15")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*5

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 300 g

*1 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2
*2 Measurement range when the sampling cycle is 20 µs or more.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*4 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*5 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

LK-H155 Keyence
Keyence LK-H155 Keyence
Sale price 36,737.00 kr
Only 5 units left

Specifications

Model

LK-H155

Mounting mode

Diffuse reflective

Reference distance

150 mm5.906"

Measuring range

±40 mm ±1.57"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

120 µm x 4,200 µm

Linearity

±0.02% of F.S. (F.S.= 80 mm 3.15")*2

Repeatability

0.25 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 80 mm 3.15")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 300 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

LK-H150 Keyence
Keyence LK-H150 Keyence
Sale price 36,737.00 kr
Only 8 units left

Specifications

Model

LK-H150

Mounting mode

Diffuse reflective

Reference distance

150 mm5.906"

Measuring range

±40 mm ±1.57"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

ø120 µm

Linearity

±0.02% of F.S. (F.S.= 80 mm 3.15")*2

Repeatability

0.25 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 80 mm 3.15")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 300 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

Keyence New Stock Image
Keyence LK-H087 Keyence
Sale price 27,488.00 kr
Only 10 units left

Specifications

Model

LK-H087

Mounting mode

Diffuse reflective / Specular reflective*1

Reference distance

Diffuse reflective: 80 mm 3.15"
Specular reflective: 76.7 mm 3.02"

Measuring range

Diffuse reflective: ±18 mm ±0.71"
Specular reflective: -17.6 mm to +14.5 mm -0.69" to +0.57"*2

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

70 µm x 2,500 µm

Linearity

±0.02% of F.S. (F.S.= 36 mm 1.42")*3

Repeatability

0.1 µm*4

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S. (F.S.= 36 mm 1.42")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*5

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 280 g

*1 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2
*2 Measurement range when the sampling cycle is 20 µs or more.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*4 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*5 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

Keyence Stock Image
Keyence LK-H085 Keyence
Sale price 26,134.00 kr
Only 10 units left

Specifications

Model

LK-H085

Mounting mode

Diffuse reflective

Reference distance

80 mm 3.15"

Measuring range

±18 mm ±0.71"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

70 µm x 2,500 µm

Linearity

±0.02% of F.S. (F.S.= 36 mm 1.42")*2

Repeatability

0.1 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 36 mm 1.42")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 280 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

Keyence New Stock Image
Keyence LK-H082 Keyence
Sale price 21,886.00 kr
In stock, 12 units

Specifications

Model

LK-H082

Mounting mode

Diffuse reflective / Specular reflective*1

Reference distance

Diffuse reflective: 80 mm 3.15"
Specular reflective: 76.7 mm 3.02"

Measuring range

Diffuse reflective: ±18 mm ±0.71"
Specular reflective: -17.6 mm to +14.5 mm -0.69" to +0.57"*2

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

ø70 µm

Linearity

±0.02% of F.S. (F.S.= 36 mm 1.42")*3

Repeatability

0.1 µm*4

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S. (F.S.= 36 mm 1.42")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*5

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 280 g

*1 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2
*2 Measurement range when the sampling cycle is 20 µs or more.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*4 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*5 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

Keyence Stock Image
Keyence LK-H080 Keyence
Sale price 19,818.00 kr
Only 9 units left

Specifications

Model

LK-H080

Mounting mode

Diffuse reflective

Reference distance

80 mm 3.15"

Measuring range

±18 mm ±0.71"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

ø70 µm

Linearity

±0.02% of F.S. (F.S.= 36 mm 1.42")*2

Repeatability

0.1 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 36 mm 1.42")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 280 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

LK-H057K Keyence
Keyence LK-H057K Keyence
Sale price 24,091.00 kr
In stock, 15 units

Specifications

Model

LK-H057K

Mounting mode

Specular reflective

Reference distance

46.3 mm1.823"

Measuring range

±5.2 mm ±0.20"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

50 µm x 2,000 µm

Linearity

±0.02% of F.S. (F.S.= 20 mm 0.79")*2

Repeatability

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S. (F.S.= 20 mm 0.79")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

LK-H057 Keyence
Keyence LK-H057 Keyence
Sale price 24,091.00 kr
In stock, 15 units

Specifications

Model

LK-H057

Mounting mode

Diffuse reflective

Reference distance

50 mm 1.97"

Measuring range

±10 mm ±0.39"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

50 µm x 2,000 µm

Linearity

±0.02% of F.S. (F.S.= 20 mm 0.79")*2

Repeatability

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 20 mm 0.79")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

LK-H055 Keyence
Keyence LK-H055 Keyence
Sale price 24,091.00 kr
Only 6 units left

Specifications

Model

LK-H055

Mounting mode

Diffuse reflective

Reference distance

50 mm 1.97"

Measuring range

±10 mm ±0.39"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

50 µm x 2,000 µm

Linearity

±0.02% of F.S. (F.S.= 20 mm 0.79")*2

Repeatability

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 20 mm 0.79")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

LK-H052K Keyence
Keyence LK-H052K Keyence
Sale price 27,752.00 kr
Only 8 units left

Specifications

Model

LK-H052K

Mounting mode

Specular reflective

Reference distance

46.3 mm1.823"

Measuring range

±5.2 mm ±0.20"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

ø50 µm

Linearity

±0.02% of F.S. (F.S.= 20 mm 0.79")*2

Repeatability

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S. (F.S.= 20 mm 0.79")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

LK-H052 Keyence
Keyence LK-H052 Keyence
Sale price 27,752.00 kr
In stock, 11 units

Specifications

Model

LK-H052

Mounting mode

Diffuse reflective

Reference distance

50 mm 1.97"

Measuring range

±10 mm ±0.39"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

ø50 µm

Linearity

±0.02% of F.S. (F.S.= 20 mm 0.79")*2

Repeatability

0.025 µm*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 20 mm 0.79")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 260 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

LK-H027K Keyence
Keyence LK-H027K Keyence
Sale price 24,091.00 kr
Only 8 units left

Specifications

Model

LK-H027K

Mounting mode

Specular reflective

Reference distance

16.1mm0.634"

Measuring range

±2.8 mm ±0.11"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

25 µm x 1,400 µm

Linearity

±0.02% of F.S. (F.S.= 6 mm 0.24")*2

Repeatability

0.02 µm (0.01 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm 0.24")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 230 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

LK-H027 Keyence
Keyence LK-H027 Keyence
Sale price 24,091.00 kr
In stock, 13 units

Specifications

Model

LK-H027

Mounting mode

Diffuse reflective

Reference distance

20mm0.787"

Measuring range

±3 mm ±0.12"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

25 µm x 1,400 µm

Linearity

±0.02%of F.S. (F.S.= 6 mm 0.24")*2

Repeatability

0.02 µm (0.01 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm 0.24")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 230 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

LK-H025 Keyence
Keyence LK-H025 Keyence
Sale price 24,091.00 kr
Only 4 units left

Specifications

Model

LK-H025

Mounting mode

Diffuse reflective

Reference distance

20mm0.787"

Measuring range

±3 mm ±0.12"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

25 µm x 1,400 µm

Linearity

±0.02%of F.S. (F.S.= 6 mm 0.24")*2

Repeatability

0.02 µm (0.01 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm 0.24")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 230 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

Keyence New Stock Image
Keyence LK-H022K Keyence
Sale price 58,458.00 kr
Only 5 units left

Specifications

Model

LK-H022K

Mounting mode

Specular reflective

Reference distance

16.1mm0.634"

Measuring range

±2.8 mm ±0.11"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

ø25 µm

Linearity

±0.02% of F.S. (F.S.= 6 mm 0.24")*2

Repeatability

0.02 µm (0.01 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm 0.24")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 230 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.

LK-H022 Keyence
Keyence LK-H022 Keyence
Sale price 27,752.00 kr
Only 5 units left

Specifications

Model

LK-H022

Mounting mode

Diffuse reflective

Reference distance

20mm0.787"

Measuring range

±3 mm ±0.12"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 2
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.95mW

Spot diameter (at standard distance)

ø25 µm

Linearity

±0.02% of F.S. (F.S.= 6 mm 0.24")*2

Repeatability

0.02 µm (0.01 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm 0.24")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 230 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

LK-H020 Keyence
Keyence LK-H020 Keyence
Sale price 26,531.00 kr
Only 9 units left

Specifications

Model

LK-H020

Mounting mode

Diffuse reflective

Reference distance

20mm0.787"

Measuring range

±3 mm ±0.12"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 3R
FDA(CDRH)21CFR Part 1040.10: Class IIIa

Output

4.8mW

Spot diameter (at standard distance)

ø25 µm

Linearity

±0.02% of F.S. (F.S.= 6 mm 0.24")*2

Repeatability

0.02 µm (0.01 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.01% of F.S./°C (F.S.= 6 mm 0.24")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 230 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

LK-H008W Keyence
Keyence LK-H008W Keyence
Sale price 16,769.00 kr
Only 5 units left

Specifications

Model

LK-H008W

Mounting mode

Specular reflective

Reference distance

8 mm0.315"

Measuring range

±0.5 mm ±0.02"*1

Light source

Type

Red semiconductor laser

Wavelength

655nm

Laser class

IEC 60825-1: Class 1
FDA(CDRH)21CFR Part 1040.10: Class II

Output

0.3mW

Spot diameter (at standard distance)

20 µm x 550 µm

Linearity

±0.05% of F.S. (F.S.= 1 mm 0.04")*2

Repeatability

0.005 µm (0.001 µm)*3

Sampling cycle

2.55/5/10/20/50/100/200/500/1000 µs (9 steps selectable)

Temperature characteristics

0.02% of F.S./°C (F.S.=1 mm 0.04")

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp or fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 240 g

*1 Measurement range when the sampling cycle is 20 µs or more.
*2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical e x ample of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs.
*4 When the ambient temperature rises to 40 °C 104 °F or more, mount this on a metal plate before use.

Recently viewed