keyence Stock Image
Keyence OP-84490 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence XR-HT15MD Keyence
Sale price 32,018.00 kr
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence VJ-3302 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence VS-C1500CX Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

VS-C1500CX

Storage

Internal storage

7 GB

microSD card (external)

Max. 64 GB *1

Image sensor

Image size

1.1"

Pixel size

2.5 μm 0.10 Mil

Frame rate

40 fps

Lens

Mount

C-mount

I/O connection

Number of inputs

1 (insulated)

Number of outputs

3 (insulated)

Number of inputs/outputs

2 (insulated) (input and output switched via settings)

I/F

Ethernet

PoE IEEE 802.3at, M12 X cable × 1

I/O

1 In/3 Out/2 In, Out M12 A cable × 1

Lighting interface

Dedicated lighting connection interface × 1

External media

microSD card slot × 1

Functions

Output image pixels

4400 × 3296

Exposure time

0.008 msec to 1000 msec

Image correction functions

Gain, Offset, Gamma correction, White balance, Fine HDR

Indicators

OLED display, Status LED, Ethernet LED (LINK/ACT), SD card access indicator

Buttons

Operation buttons × 3

Installation support functions

Angle monitor

Power supply

Power voltage

24 V +25%/−20% or PoE (IEEE802.3at Power Class 4)

Current consumption (camera only)

0.97 A, 18.7 W (for 19.2 V)/0.78 A, 18.7 W (for 24 V)

Current consumption (including lighting)

4.7 A, 89.7 W (for 19.2 V)/3.8 A, 89.7 W (for 24 V)

Current consumption (With CA-DEx10X connected)

11.3 A, 216.7 W (for 19.2 V)/9.1 A, 216.7 W (for 24 V) *2

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.05 G2/Hz; X, Y, and Z directions, 0.5 hours (IEC60068-2-64)

Shock resistance

50 G, 3 times in each of the 6 directions (IEC60068-2-27)

Size (H×W×D)

93.2 mm × 52.6 mm × 66 mm 3.67" × 2.07" × 2.60"

Case temperature

0°C to 65°C 32 to 149°F *3

Standard certifications

CE, FCC, NRTL, KC, UKCA

Material

Case: Aluminum die-casting, Front cover: Glass *4

Weight

Approx. 420 g 14.83 oz

*1 Using the configuration software, format the media before use.
*2 Maximum instantaneous current. Average current is below current consumption (including lighting).
*3 Reference - Case temperature 65°C 149°F with 200 mm × 200 mm × 10 mm 7.87" × 7.87" × 0.39" aluminum board and at ambient temperature of 40°C 104°F.
*4 ESD-Safe, IEC61340-5-1 compliant.

keyence Stock Image
Keyence OP-87604 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-87604

Type

Display panel cable

Length

10 m 32.8'

Cable min. bending R

24 mm 0.94"

Environmental resistance

Enclosure rating

None

Material

PVC

Weight

Approx. 700 g

keyence Stock Image
Keyence FU-98 Keyence
Sale price 5,111.00 kr
Only 1 unit left

Specifications

Model

FU-98*1

Type

Thrubeam

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø2.2

Minimum bend radius

R40 mm1.575"

Minimum detectable object

Opaque material with a diameter of 0.2 mm0.008"*2

Tightening torque

0.75 or less (when attaching the OP-87095)

Environmental resistance

Enclosure rating

IP67*3

Ambient temperature

-40 to +70 °C -40 to 158 °F (No condensation and no freezing)*4

Relative humidity

35 to 85 % RH (No freezing and No condensation)*4

Material

Main unit case : PFA, tube : PTFE*3

Accessories

Fiber cutter

Weight

Approx. 70 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.
*3 Using this product in high-temperature liquids or steam may lead to penetration of the fluorocarbon polymers, which may cause fluctuations in the received light intensity and damage to the internal components.
*4 Use this product under the condition that if the ambient temperature exceeds 60 °C 140 °F, the absolute humidity is 60 °C 140 °F 85 % RH or less.

keyence Stock Image
Keyence FD-EPH7 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

FD-EPH7

Pipe size

Outer diameter of pipe

1/4” (Approx.
6.35 mm 0.25") *1

Compatible outer diameter range

Polyurethane

6.35 ±0.15 mm
0.25" ±0.006"

Nylon

6.35 ±0.1 mm
0.25" ±0.004"

Pipe materials

Resin pipe connectible to a one-touch coupling

Supported gases

Air, nitrogen, argon, and non-corrosive gases*2

Supported gas temperature

−10°C to +60°C 14 to 140°F

Pressure resistance

1 MPa

Flow rate detection principle

Ultrasonic transmission time difference method

Flow rate specifications

Rated flow rate

(volume flow rate)

60 L/min 2.12 CFM

(20°C 68°F, atmospheric pressure conversion) * Initial display

Gas at 20°C 68°F, 0.0 MPa

Gas at 20°C 68°F, 0.2 MPa

180 L/min 6.35 CFM

Gas at 20°C 68°F, 0.4 MPa

300 L/min 10.59 CFM

Gas at 20°C 68°F, 0.6 MPa

420 L/min 14.8 CFM

Measurement accuracy

±(2.0% of RD+1.0% of F.S.)*3*4

Repeatability

Response time of 250 ms: ±2.5% of F.S.*3*5

Pressure specifications

Rated pressure

−100 kPa to +0.75 MPa * However, the flow rate cannot be measured in the range of −100 to −50 kPa.

Overall accuracy

±2.0% of F.S.*3

Repeatability

Response time of 2.5 ms: ±0.4% of F.S.

Display resolution

Instantaneous flow

0.01/0.1 L/min

Accumulated flow

0.01/0.1/1/10/100 L

Pressure

0.1/1 kPa

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient temperature

−10°C to +60°C 14 to 140°F (no freezing)

Relative humidity

35%RH to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes

Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material

Sensor unit (parts that do not contact the gas)

PBT/PAR/iron/Brass electroless nickel plating/POM/NBR/stainless steel

Flow channel (parts that contact the gas)

PBT/Brass electroless nickel plating/NBR/nylon

Weight

Approx. 129 g 4.55 oz

*1 To ensure stable detection, it is recommended to use a pipe inner diameter that is at least equivalent to the inner diameter of this product.
*2 Gases that transmit ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.
*3 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the condition and type of pipes as well as the temperature and type of gas.
*4 This specification is valid when sufficient straight sections of pipe are provided and the flow velocity distribution is stable. This value does not take into account the effects of fluctuations in flow velocity distribution due to facility factors.
*5 Accuracy improves with longer response times. As a rule, this is by a proportion of √(250 ms/response time)x.

Keyence Stock Image
Keyence SV2-075L2 Keyence
Sale price 7,336.00 kr
Only 2 units left

Specifications

Model

SV2-075L2

General specifications

Capacity

750 W

Input power supply

Voltage/frequency

Main circuit

3-phase (or single phase) 200 to 240 VAC +10 to -15%, 50/60 Hz
270 to 324 VDC *1

Control circuit

Single-phase 200 to 240 VAC +10 to -15%, 50/60 Hz
270 to 324 VDC *1

Allowable frequency fluctuation

Main circuit/control circuit

No more than ±5%

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method

Feedback

22-bit serial encoder (absolute) communication,
fully closed control serial communication, analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20

Pollution degree

Pollution degree: 2 (in an IP54 or higher control panel)
However, usage under the following requirements required:
• No corrosive gas or flammable gas present
• No exposure to water, oil, or chemicals
• No dust present

Operating ambient temperature

-5 to +60°C 23 to 140°F (no freezing; reduced ratings at +55°C 131°F or more)

Storage ambient temperature

-20 to +85°C -4 to +185°F (no freezing)

Operating/storage ambient temperature

95% RH or less (no condensation)

Altitude

2000 m 6561.7' or less above sea level (usable at reduced ratings at 1000 m 3280.8' or more)

Vibration resistance

4.9 m/s2 16.1'/s2 (JIS C60068-2-6 compliant)

Impact resistance

19.6 m/s2 64.3'/s2 ( JIS C60068-2-27 compliant)

Other

No static electricity noise, strong electric fields, magnetic fields, or radiation present

Min. insulation resistance

500 VDC, 1 MΩ or more with insulation resistance tester

Applied standard

UL/CSA standards

UL61800-5-1, CSA22.2 No.274

CE marking

Low-voltage directive

EN61800-5-1, EN50178

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part15 B, ICES-003. Class A

Structure

Type

Attached to base mount

Safety function

STO function (STO/EN61800-5-2)

Safety function

Safety parameters

SIL3/EN61508, SIL CL 3/EN62061,
PLe (Category3) / EN ISO13849-1: 2008

Response time

8 ms (max.)

Input

STO1, STO2: Base block signal for power module
Internal impedance: 4.7 kΩ
Operable voltage range: +24 V ±20%
Max. delay time: 8 ms
(Time from turning STO1, STO2 off until motor current cutoff)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 8 ms
(Time from changing STO1, STO2 until EDM change)

Applied standard

EN61800-5-2, EN ISO13849-1: 2008, EN61508, EN62061, EN60204-1, EN61326-3-1

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative abnormalities, etc.

Insulation withstand voltage

1500 VAC or more (between primary side and ground)
3000 VAC or more (between primary side and secondary side)
350 VAC: Between secondary circuit and ground

Weight

Approx. 1.6 kg

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/Single phase 200 V

Max. applicable motor capacity

750 W

Power supply capacity for 1 amplifier

Three-phase 200 V: 1.6 kVA, Single phase 200 V: 1.9 kVA

Output current

Continuous

5.5 Arms

Max.

16.9 Arms

Main circuit power loss

43.8 W

Regenerative resistor power loss

8 W

Control circuit power loss

17 W

Total power loss

68.8 W

Rated input current

Main circuit

Three-phase 200 V: 4.1 Arms, Single phase 200 V: 8.7 Arms

Control circuit

0.2 Arms

Rush current

Main circuit

34 A

Control circuit

Performance specifications

Performance

Speed control range

1:5000 (load torque ≤ rated torque conditions)

Speed fluctuation rate

At load fluctuation

±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed)

At main circuit voltage change

0% with ±10% of rated voltage (at rated rotation speed)

At ambient temperature change

±0.1% or less with ambient temperatures of 0 to +50°C 32 to 122°F (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Speed frequency response frequency

2.6 kHz

Dynamic brake

Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: 50 W to 400 W ... not installed
750 W to 5.0 kW ... installed
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW *2)

Display Function

Panel function

7-segment LED
Rotary switch ×2 (16 ch)
Slide switch ×1 (4 ch)

Status display LED

CHARGE: For notification of main circuit power supply input (orange)
POWER: For notification of control circuit power supply input (green)
CONNECT: For notification of connection (green)
LINK1, LINK2: For notification of MECHATROLINK communication (green)

Auxiliary function

Gain control, alarm history, Z-phase search, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed input, 4 general input)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Min. OFF current/voltage

High-speed input: 0.6 mA, general input: 0.3 mA

Common point mode

7 points/1 common point (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.5 mA, general input: 3.7 mA

Input impedance

Approx. 4.7 kΩ

Assignable input signals

Full signal assignment, logic-settable forced stop (FSTOP),
external latch signals 1 to 3 (EXT1, EXT2, EXT3),
origin return deceleration switch (DEC), forward limit switch (LSP),
reverse limit switch (LSN), forward torque limit selection (PTL),
reverse torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC / 50 mA

Leakage current when OFF

0.1 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Individual signal assignment excluding ALARM signal, logic-settable alarm (ALARM),
in position (INPOS), speed matching (VCMP), zero speed detection (ZSP),
operation preparation complete (RDY), torque limiting (TLM),
speed limiting (VLM), electromagnetic brake timing (BRAKE),
warning (WARN), Positioning proximity (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±10 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

Phase A (A+/A−), phase B(B+/B−), phase Z (Z+/Z−): Differential line-driver output

Line driver

SN75ALS174 (T.I.) or equivalent

Output frequency

1.6 Mbps (with 2-phase, 4 times multiplication, 6.4 MHz or equivalent) *3

Analog monitor output

No. of channels

2 ch

Output range

±10 V (linearity valid range ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

MECHATROLINK-III communication

Communication protocol

MECHATROLINK-III

Station address

03H to EFH (Max. number of connectable slaves: 62)

Transmission speed

100 Mbps

Transmission frequency

125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms)

Communication cycle

Support for values starting at transmission frequency × 1

Number of transmitted bytes

32 bytes/station, 48 bytes/station (selectable with slide switch)

Transmission media/cable

Category 5e-compliant, STP cross cable

Operating specifications

Position control / speed control / torque control

Command input

MECHATROLINK-III command
(sequence, motion, monitor, adjustment, etc.)

Max. transmission distance

50 m 164.0' *4

USB communication

Connected device

PC

Communication standard

USB 2.0-compliant

Function

Status display, parameter setting, tuning, etc.

*1 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*2 Use of 2 kW, 3 kW, and 5 kW servo amplifiers is possible depending on the operating conditions.
*3 The division ratio can be set arbitrarily with a parameter.
*4 For instances with 30 m 98.4' or more, use ferrite cores (OP-84409) with 2 turn-winding.

keyence Stock Image
Keyence CL-L030 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CL-L030 *1

Type

Sensor head (30 mm ・Quad type)

*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit.

keyence Stock Image
Keyence DX-UC1M Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence LS-5040 Keyence
Sale price 52,850.00 kr
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence GP-M001 Keyence
Sale price 7,206.00 kr
Only 8 units left

Specifications

Model

GP-M001

Rated pressure

-14.50 to +14.50 PSI
(-100 to +100 kPa)

Possible display range

-17.40 to +17.40 PSI
(-120.0 to +120.0 kPa)

Zero-cut pressure value

±0.5% of F.S.

Burst pressure

217.5 PSI (1500 kPa)

Display resolution

kPa

0.1

MPa

None

PSI

0.01

bar

0.001

kgf/cm2

Fluid type

Gas or liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure

Precision

±1.0% of F.S. or less*1

Repeatability

±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C 50°F

Connection port

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Medium temperature

-20 to +100°C -4°F to +212°F (no freezing/condensation)*3

Power voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)

Hysteresis

During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)

Response

Control output

Selectable from 3 to 5000 ms

Analog output

As above + 2 ms (90% response)

Output

Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analog output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5

Environmental resistance

Enclosure rating

IP67

Pressure resistance

400 kPa (4 bar)

Ambient temperature

-20 to +80 °C -4 to 176 °F (No freezing and no condensation)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axis)

Shock resistance

IEC60068-2-27 50G (11 ms, 3 times for each of X, Y and Z direction)

Material
properties

Wetted part

Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin

Weight

Approx. 150 g

*1 This is the value when considering linearity + hysteresis + repeatability in a stable environment of 23°C 73°F.
*2 The repeatability, based on consistent conditions, is the variation in the value that will be displayed.
*3 When the temperature of the piping exceeds 80°C 176°F, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω

keyence Stock Image
Keyence CA-DRR5 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence GS-H01 Keyence
Sale price 5,719.00 kr
Only 2 units left

Specifications

Model

GS-H01

Weight

Approx. 1070 g

keyence Stock Image
Keyence SJ-H204A Keyence
Sale price 16,299.00 kr
Only 1 unit left

Specifications

Model

SJ-H204A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

2040 mm 80.31" *3

No. ofelectrodes

32

Static elimination bar length

2000 mm 78.74"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

2000 g 70.55 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence AP-C33W Keyence
Sale price0.00 kr
Sold Out
Buy the Keyence AP-C33W - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence AP-C33W is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence OP-88003 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-3107 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-3107

Overview

Teflon cap with M14 inner diameter. Protect from weld spatter.

Applicable product

EH-114

Material

PTFE

keyence Stock Image
Keyence NR-CM01 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

NR-CM01

Type

Standard model

PC interface

USB communications standard

USB2.0 High Speed

Supported OS

Windows® 11 Home/Pro/Enterprise
Windows® 10 Home/Pro/Enterprise

Power supply

USB bus power

Power consumption

650 mW max.

Image sensor

Color CMOS

Image resolution

Up to 1920 × 1080

Frame rate

Up to 30 fps

Optical performance

Field of view

At 150 mm 5.91" distance:
280 × 160 mm 11.02" × 6.30"
At 300 mm 11.81" distance:
570 × 320 mm 22.44" × 12.60"
At 1000 mm 39.37" distance:
1900 × 1070 mm 74.80" × 42.13"
*1

Installation distance

150 mm 5.91" or more

Environmental resistance

Enclosure rating

IP67

Ambient temperature

−20 to 55°C −4°F to 131°F (no freezing)

Relative humidity

85% RH or less (no condensation)

Material

Body: Aluminum, Window: Acrylic, Connector: Brass (nickel plated)

Weight

Approx. 120 g 4.23 oz

*1 Fields of view are reference values.

keyence Stock Image
Keyence CL-EC100 Keyence
Sale price 40,536.00 kr
Only 2 units left

Specifications

Model

CL-EC100

EtherCAT communication specifications

Conforming standard

IEEE802.3u (100BASE-TX)*1

Communication speed

100 Mbps (100BASE-TX)*1

Communication period

Shortest 125 µs*1

Connection cable

STP/UTP cable, category 5e or above*1

Inter-node distance

100 m 328.1'*1

Communications port

RJ45 × 2*1

Supported functions

Process Data Object (PDO)
communication (Cyclic communication:
Process data communication)
Service Data Object (SDO) communication
(Non-cyclic communication: Mailbox
communication)
CoE
Distributed Clock
Explicit Device Identification*1

Environmental resistance

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

20% RH to 85% RH (no condensation)

Weight

Approx. 330 g

*1 Cannot be used when using EtherNet/IP™, PROFINET or PLC Link. • Cannot be used simultaneously with an encoder unit.

Keyence New Stock Image
Keyence LV-NH62 Keyence
Sale price 2,800.00 kr
In stock, 11 units

Specifications

Model

LV-NH62

Type

Standard

FDA (CDRH) Part 1040.10

Class 1

IEC 60825-1

Light source

Visible semiconductor laser, Wavelength: 660 nm

Detecting
distance

MEGA

8 m 26.2'

ULTRA

7 m 23.0'

SUPER

6 m 19.7'

TURBO

5 m 16.4'

FINE

3.5 m 11.5'

HSP

2 m 6.6'

Environmental resistance

Ambient temperature

-10 to +55°C 14°F to 131°F (No freezing)

Relative humidity

35 to 85% RH (No condensation)

Material

Case

Glass-reinforced plastic

Lens cover

Norbornene plastic

Reflective mirror

Polycarbonate, Acrylic

Weight

Approx. 65 g 2.29 oz

keyence Stock Image
Keyence OP-42323 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-42323

Type

Single Light Guide for Coaxial Micro Lens

Overview

Single-type light guide for mounting optical fiber lighting.

Applicable product

CV-F10, CA-LMAx

keyence Stock Image
Keyence GL-RC20M Keyence
Sale price 3,646.00 kr
Only 3 units left

Specifications

Model

GL-RC20M

Type

Extension Cable

Applicable product

GL-R Series

Number included

1 cable

Cable end

M14 connector (12-pin female) - Loose wires

Length

20 m 65.62'

Material

Connector for extension: PVC/nickel-plated brass, Cable: PVC

Note

Extension cable for the GL-R Series. Use this together with the main unit connection cable (for extension).
Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2)

Weight

Approx. 910 g

Keyence Stock Image
Keyence GL-R06L Keyence
Sale price 6,213.00 kr
Only 10 units left

Specifications

Model

GL-R06L

Detection capability

ø1.77" ø45 mm

Total length

9.45" 240mm

No. of beam

6

Detection height

7.87" 200mm

Protection height

11.22" 285mm

Beam axis spacing/Lens diameter

40 mm / ø5 1.57" / ø0.20"

Detecting distance

0.66 to 49.21' 0.2 to 15 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

6.6

OFF→ON

48.7*2

All blocked→ON

63.1*3

Optical synchronization system
(Channel A or B)

ON→OFF

6.9

OFF→ON

49.1*2

All blocked→ON

64.2*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

39

Receiver

67

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

320 g

Receiver

330 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.