Machine Vision Systems

5768 products

Showing 481 - 504 of 5768 products

Showing 481 - 504 of 5768 products
View
keyence Stock Image
Keyence OP-87984 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence XG-H200C Keyence
Sale price 12,454.00 kr
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence RK-10IM Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence TM-X5120 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

TM-X5120

Transmitter/receiver distance

436.7 mm 17.19"

Measuring range

Field of view

High-accuracy measurement area

ø60 mm ø2.36"

Measurement area

ø124 mm ø4.88"

Depth of field

High-accuracy measurement area

20 mm 0.79"

Measurement area

40 mm 1.57"

Exposure time

25/50/100 μs (Adjustable 3-stage)

Imaging time (Trigger interval)

Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes)
Approx. 3 ms (at “4/16” vertical/horizontal measurement range sizes)

Light source

InGaN green LED

Measurement position accuracy

High-accuracy measurement area

±2.5 μm ±0.000098" *1

Measurement area

±3.5 μm 0.000138" *1

Repeatability

±0.2 μm ±0.000008" *2

Pixel resolution

Approx. 66 μm 0.002598"

Environmental resistance

Enclosure rating

IP64 *3

Ambient temperature

0 to +45°C 32 to 113°F

Relative humidity

85% RH or less (No condensation)

Material

Aluminum/PBT

Weight

Transmitter: Approx. 5900 g 13.01 lb
Receiver: Approx. 7900 g 17.42 lb
Base: Approx. 4300 g 9.48 lb

*1 Error when measuring width of KEYENCE standard object (glass calibration scale).
*2 Average value of ±2σ measuring the width of a KEYENCE standard object (glass calibration scale) 16 times in the center of the measurement area.
*3 Excluding connectors and cable boxes.

Keyence Stock Image
Keyence FU-95Z Keyence
Sale price 5,853.00 kr
Only 8 units left

Specifications

Model

FU-95Z

Type

Liquid-level detection fiber unit

Detecting method

Pipe mounting type

Mounting transparent tube diameter

ø4 to 26 mmø0.157" to 1.024"

No. of beam axes

1 mm0.039"

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.0×2

Minimum bend radius

R2 mm0.079" Tough-Flex

Environmental resistance

Ambient temperature

-40 to +50 °C -40 to 122 °F

Accessories

Binding band × 2, nonslip rubber × 2, spacer × 2, screw × 2, nut × 2

Weight

Approx. 7 g

Keyence Stock Image
Keyence SJ-M040 Keyence
Sale price 7,612.00 kr
In stock, 12 units

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

FS-N11N Keyence
Keyence FS-N11N Keyence
Sale price 1,447.00 kr
In stock, 34 units

Specifications

Model

FS-N11N

Type

Standard 1 output
Cable

Output

NPN

Main unit/expansion unit

Main unit

Control output

1
NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

Monitor output (1-5 V)

-

External input

Light source LED

Red, 4-element LED

APC

ON/OFF switchable (Factory setting: OFF)

Response time

50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Number of interference prevention units

0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)

Unit expansion

Up to 16 units can be connected total (two output type is treated as two units)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current Consumption

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1
Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1
Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less

Ambient temperature

-20 to +55 °C -4 to +131 °F (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Both main unit and expansion unit housing material: Polycarbonate

Weight

Approx. 75 g

*1 Increases 100 mW (4.0 mA) for High Speed mode
*2 One or two more units connected: -20 to +55 °C (-4 to +131 °F); 3 to 10 more units connected: -20 to +50 °C (-4 to +122 °F); 11 to 16 more units connected: -20 to +45 °C (-4 to +113 °F).
When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.

Keyence New Stock Image
Keyence KV-10AR Keyence
Sale price 4,366.00 kr
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence FU-56TZ Keyence
Sale price 8,979.00 kr
Only 5 units left

Specifications

Model

FU-56TZ*1

Type

fibre unit

Shape

Thrubeam

Minimum bend radius

R2 mm

Minimum detectable object

Opaque material with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-40 to +50 °C -40 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 20 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

keyence Stock Image
Keyence KV-SSC02 Keyence
Sale price 7,367.00 kr
Only 5 units left

Specifications

Model

KV-SSC02

Type

High-speed counter unit

Input frequency

Single phase 4 MHz (16 MHz during 2-phase, 4-multiplication)

Counting range

32 bits

Number of channels

2 ch

Mode

Input selection

External terminal (CH0, CH1), internal clock (0.05 μs, 1 μs, 10 μs, 100 μs), other CH coincidence output, communication: EnDat2.2/22, BiSS (C-mode), YASKAWA serial

Input mode

1-pulse with/without direction, 2-pulse addition/subtraction operation, 2-phase 1-multiplication/2-multiplication/4-multiplication

Counting operation mode

• Up-down counting mode • Enable counting mode • Preset counting mode • Set timer counting mode • Enable accumulative counting mode

Counting mode

Linear, ring

Frequency, revolution counter operation mode

• Frequency counting mode • Revolution counter B mode (1-revolution time measurement) • Revolution counter A mode (pulse interval measurement)

Input

Count input

A-phase/B-phase/Z-phase (preset), 3 points for each channel, 6 points in total
5/12/24 VDC input possible, line driver input possible, photocoupler insulation

Control input

Enable (also used for input capture) input, 1 point for each channel, 2 points in total
12 to 24 VDC input possible, photocoupler insulation
Input capture input, 2 points for each (4 points in total)
12 to 24 VDC input possible, photocoupler insulation

Output

Comparator coincidence output

2 points for each channel, 4 points in total, photocoupler insulation
Rated load: 30 VDC, 0.2 A or less

Input capture function

By external input (max. 4 points)

Buffering function

Buffering period: 1 μs or more

Input filter function

Input time constant switching (6 types of counting/9 types of control)

Preset function

Possible to select from preset (Z-phase) input and internal relay-based rising edge/falling edge/level (only when an external input is used)

Serial encoder communication function

Supported encoder

Absolute encoders that support EnDat2.2/22, BiSS (C-mode), and YASKAWA serial

Communication cycle

EnDat2.2/22: 50 μs, BiSS (C-mode): 50 μs, YASKAWA serial: 62.5 μs

Input

Equivalent to a differential line receiver that meets the EIA RS485 standard

Output

Equivalent to a differential line driver that meets the EIA RS485 standard

Encoder 5 V power

5 VDC (±5%), 300 mA or less

Others

Unit interrupt, inter-unit synchronization

Internal current consumption

190 mA or less

Weight

Approx. 130 g

keyence Stock Image
Keyence CA-DBB8 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CA-DBB8

Type

Bar Light

LED color

Blue

Diffusion plate

OP-87042

Polarizing plate

OP-87043

Power consumption

4.8 W

Input voltage

12 VDC

Weight

Approx. 60 g

keyence Stock Image
Keyence SV2-D20AG Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SV2-D20AG

Type

Motor power cable, Hi-flex robotic cable with electromagnetic brake

Length

20 m 65.6'

Note

for 50 W / 100 W motor

keyence Stock Image
Keyence GS-71P10 Keyence
Sale price 4,751.00 kr
Only 5 units left

Specifications

Model

GS-71P10

Lock type

Power-to-lock type

Type

Standard type

Response time

Lock

Lock→Unlock

320 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 770 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

keyence Stock Image
Keyence OP-88100 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88100

Type

Vertical Mounting Bracket

Applicable product

AI-H010, AI-H020

Note

Short range, for Separate amplifier models

Keyence Stock Image
Keyence KV-NC32ET Keyence
Sale price 12,516.00 kr
Only 4 units left

Specifications

Model

KV-NC32ET

Expansion output unit

External connectionmethod

MOSFET (With overcurrent protection function)*1*2

External connection method

Connector

Rated load

30 VDC. 0.2 A *3

Leakage current (when output is OFF)

100 μA or less

Residual voltage (at ON)

0.6 VDC or less

ON resistance

Common method

32 points/1 common (2 terminals)*4*5

Response time

OFF to ON

100 μs or less (with a load of 1 mA or more)

ON to OFF

200 μs or less (with a load of 1 mA or more)

Relay life

Relay replacement

Internal current consumption

50 mA or less

Weight

Approx. 110 g

*1 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic recovery are repeated for all outputs within the shared common (The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 015 or 100 to 115 for the KV-NC32ET(P).) , until the cause of the problem is removed.
*2 MOSFET (N-ch) output for the sink output type; and MOSFET (P-ch) output for the source output type.
*3 The rated load per common terminal is 1.6 A for the KV-NC16ET(P) or KV-NC32ET(P) and 3.2 A for the KV-NC16ET(P)E.
*4 The COM terminals of the KV-NC16ET(P), KV-NC16ET(P)E and KV-NC32ET(P) are shorted internally.
*5 The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 015 or 100 to 115 for the KV-NC32ET(P).

Keyence Stock Image
Keyence LS-5501 Keyence
Sale price 77,720.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence XG-8002P Keyence
Sale price 13,298.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence PX-H61 Keyence
Sale price 5,115.00 kr
Only 5 units left

Specifications

Model

PX-H61

Type

M12 Reflective Standard

Light source LED

Red 4-element LED
(Wavelength:635 nm)

Detecting distance

TURBO

400 mm 15.7"

SUPER

600 mm 23.6"

ULTRA

1200 mm 47.2"

MEGA

2000 mm 78.7"

Detectable object

Spot diameter

Approx. 15 x 15 mm 0.59"
at 100 mm 3.94"
Approx. 65 x 65 mm 2.56"
at 500 mm 19.69"

Environmental resistance

Enclosure rating

IEC: IP68/JEM: IP68g/NEMA: 4X, 6P, 13/DIN: IP69K

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Case material

Housing :SUS303 (Plastic parts:PMP, POM) Lens :BK7

Accessories

Screw nut x 2,
toothed washer x 1

Weight

Approx. 80 g*1 (Including cable)

*1 The PX-H71G, H72G and H61G have SUS304 spiral protective tube on the cables.

keyence Stock Image
Keyence GL-SA36S Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GL-SA36S

Type

Protection cover Slim type for 36 beam axes

Overview

This protective case protects the main unit from impacts.

Applicable product

GL-S36SH

Number included

1

Length

742.6 mm 29.24"

Material

aluminum

Note

2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm).

Weight

230 g

keyence Stock Image
Keyence LV-B102 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

LV-B102

Type

Mounting Bracket for Landscape Orientation

Applicable product

LV-NH100/NH110/H100/H110

keyence Stock Image
Keyence SV-C3F Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

SV-C3F

Type

Motor power cable, Standard

Length

3 m 9.8'

Note

for 3 kW / 5 kW motor

keyence Stock Image
Keyence GL-VM10LP Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

GL-VM10LP

Beam axis spacing/Lens diameter

40 mm 1.57": ø5 ø0.197"

Number of beam axes

10

Total length

400 mm 15.75"

Detection height

360 mm 14.17"

Protection height

445 mm 17.52"

Minimum detectable object size

ø45 mm ø1.77" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

4.3

OFF→ON

46.2 *3

All blocked→ON

51.9 *4

With channel A or B

ON→OFF

10.7

OFF→ON

54.8 *3

All blocked→ON

69.0 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

71 *5

Receiver

85 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

49 *5

Receiver

56 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

270 g 9.53 oz

Receiver

Total

540 g 19.06 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

Keyence Stock Image
Keyence CA-DBRS Keyence
Sale price 3,249.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence KV-L21V Keyence
Sale price 5,800.00 kr
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed