This Acti9 iOF is a contact auxiliary for iSW. it has a changeover contact, rated current is 3A at 415VAC and 6A at 250VAC. Mounting is performed on the left of Acti9 iSW switches with operational current less than or equal to 32A. The width in 9mm pitches is 2. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. The dimensions are (W) 18mm x (H) 77mm x (D) 75mm.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Device short name | iOF |
| Product or component type | OC contact |
| Signal contacts composition | 1 C/O |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ie] rated operational current | 3 A at 415 V AC 6 A at 250 V AC |
| Mounting mode | Fixed |
| Mounting support | 35 mm DIN rail |
| 9 mm pitches | 2 |
| Height | 77 mm |
| Width | 18 mm |
| Depth | 75 mm |
| Colour | White |
| Range compatibility | Acti9 iSW |
| Auxiliary connection terminal | Screw terminal 10 mm² |

This Acti9 iMX+OF electrical tripping auxiliary for is a shunt trip release device with open/close auxiliary contact. It is dedicated to Acti9 iC60, iID, iDPN Vigi, iSW-NA. This device includes an open/close contact OF to indicated the position of the associated device. The width in 9mm pitches is 2. The Uc control circuit voltage is 48VAC or 48VDC. It can be mounted on a DIN rail for modular installation. The product color is white (RAL9003). The operating temperature is -25°C to + 50°C. The storage temperature is -40°C to + 85°C. This product complies with IEC/EN 60947-5-1 standards.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Product or component type | Shunt trip release with OC contact |
| Device short name | iMX+OF |
| Signal contacts composition | 1 C/O |
| [In] rated current | AC-12 2 A at 48 V, AC 50 Hz DC-12 2 A at 48 V, DC |
| [Uc] control circuit voltage | 48 V AC 50/60 Hz 48 V DC |
| 9 mm pitches | 2 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | Acti9 iC60H RCBO Acti9 iC60H RCBO PoN Acti9 iC60H2 RCBO Acti9 iC60N RCBO Acti9 iKQE RCBO |
| Local signalling | Action indicator |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top: YES |
| Width | 18 mm |
| Colour | White |
| Connections - terminals | Clamp terminal - 1 cable(s) 5 mm² - rigid Clamp terminal - 2 cable(s) 2.4 mm² - rigid Clamp terminal - 1 cable(s) 3 mm² - flexible Clamp terminal - 2 cable(s) 2.4 mm² - flexible with cable end |
| Tightening torque | 1 N.m |
| Compatibility code | IMX+OF |

This Acti 9 iACTs is reliable remote indication auxiliary. It has 1 changeover contact, it operates from 24VAC to 240VAC and 24VDC to 130VDC. Mounting is performed on the right of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is compatible with all Acti9 iCT Contactors. This product helps reporting the status of a contactor and is especially required in a connected environment. This product is compliant with EN 60947-5.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | ICT |
| Range | Acti9 |
| Device short name | iACTs |
| Product or component type | Remote indication auxiliary |
| Signal contacts composition | 1 C/O |
Complementary
| Characteristic | Value(s) |
|---|---|
| Signalling circuit voltage | 24 V AC/DC: 10 mA 230 V AC: 50/60 Hz 5 A 230 V AC: 50/60 Hz 2 A 130 V DC: 1 A |
| [Uc] control circuit voltage | 24...240 V AC 50/60 Hz 24...130 V DC |
| Range compatibility | Acti9 iCT |
| [Ui] rated insulation voltage | 440 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Mounting mode | Fixed, on the right of CT |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 1 |
| Height | 81 mm |
| Width | 9 mm |
| Depth | 68 mm |
| Colour | White |
| Auxiliary connection terminal | Tunnel type terminals 2 cable(s) flexible 2.5 mm² Tunnel type terminals 2 cable(s) rigid 1.5 mm² Tunnel type terminals 1 cable(s) rigid 1.5â¦2.5 mm² Tunnel type terminals 1 cable(s) flexible 1.5â¦2.5 mm² |
| Wire stripping length | 9 mm |
| Tightening torque | 0.8 N.m |
| Product compatibility | ICT |
| Market segment | Residential Small commercial |
| Compatibility code | IACTs |

This Acti 9 iTR 40VA safety transformer allows to obtain a very low voltage 12VAC or 24VAC from a network 230VAC. The transformer is safe meaning that primary and secondary circuits are perfectly insulated by each other. The power supply is 40VA. The operating frequency is 50Hz or 60Hz. The primary voltage is 230VAC +/-10%. The secondary voltage output is 12VAC or 24VAC +/-5%. It is resistant to short-circuit currents thanks to the built-in-device. The off load voltage is 14VAC for a 12VAC rated secondary voltage. The off load voltage is 28VAC for a 24VAC rated secondary voltage. It is a Class II device with terminal shield (optional). The safety transformer should be mounted on DIN rail in vertical position only. The width in 9mm pitches is 10. The weight is 1190g. The degree of protection under IEC 60529 standard is IP20 with terminal shield. The dimensions are (W) 90mm x (H) 89mm x (D) 60mm. The width in modules of 18mm is 5. The operating temperature is -20°C to 55°C. The storage temperature is -25°C to 80°C. This product complies with IEC/EN 61558-2-6 standard.
Main
| Characteristic | Value(s) |
|---|---|
| Transformer type | Safety transformer |
| Range | Acti9 |
| Range of product | Acti9 |
| product name | Acti9 iTR |
| Product or component type | Transformer |
| Device short name | iTR |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ue] rated operational voltage | 230 V AC 50/60 Hz |
| Output voltage | 12/24 V: +/-5 % on load 14/28 V: off load |
| Output short-circuit protection | Built-in |
| Rated power in VA | 40 VA |
| Temperature derating table | 40 VA 35 °C 38 VA 40 °C 32 VA 50 °C 24 VA 55 °C 18 VA 60 °C |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 10 |
| Height | 89 mm |
| Width | 90 mm |
| Depth | 60 mm |
| Colour | White |
| Auxiliary connection terminal | Tunnel type terminals 4 mm² |

This Acti9 iRTBT product is an extra low voltage relay. The Uc control circuit voltage is 12V to 24V in AC or DC networt type.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| product name | Acti9 iRTBT |
| Product or component type | Relay |
| Device short name | iRTBT |
| Device application | Extra low voltage interface relay |
| Function available | Actuation of LV circuits based on an extra low voltage order |
| Signal contacts composition | 1 C/O |
| [Uc] control circuit voltage | 12...24 V AC 12...24 V DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ie] rated operational current | 5 A at 250 V AC 0.01 A at 10 V DC |
| [Ui] rated insulation voltage | 4000 V |
| Local signalling | LED green for power ON |
| Supply holding power | 0.22 W |
| Supply inrush power | 0.11 W |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 2 |
| Colour | White |
| Electrical durability | 100000 cycles |
| Connections - terminals | Tunnel type terminals |

This Acti9 CT40 is a modular contactor. It is a 2P remote control device with 2 normally open contact. The rated current is 25A for AC-7a and 8.5A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 230VAC. This device could be used for control circuits. This product is compliant with EN/IEC 61095 standard. The maximum switching operations is 100 per day and 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 2.5kV. Pollution degree is 2. It is DIN rail mountable. Its width is 2 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 87mm x (H) 18mm x (D) 66mm. The weight is 110g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 60°C.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 CT40 |
| Product or component type | Contactor |
| Device short name | CT40 |
| Device application | Control circuit |
| Poles | 2P |
| [Ie] rated operational current | 25 A AC-7A 8.5 A AC-7B |
| Pole contact composition | 2 NO |
| Network type | AC |
| Utilisation category | AC-1 conforming to IEC 60947-4 |
| control type | Remote control |
| [Uc] control circuit voltage | 230 V AC 50 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 250 V AC 50 Hz |
| Maximum power | 3 W at 250 V AC |
| [Ui] rated insulation voltage | 500 V AC |
| [Uimp] rated impulse withstand voltage | 2.5 kV |
| Control signal type | Maintained |
| Switching frequency | 100 switching operations/day 6 switching operation/minute |
| Local signalling | Color indicator |
| Hold-in power consumption in VA | 3.8 VA |
| Inrush power in VA | 15 VA |
| Mounting mode | Clip-on |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 2 |
| Height | 87 mm |
| Width | 18 mm |
| Depth | 66 mm |
| Product weight | 110 g |
| Colour | White |
| Electrical durability | 100000 cycles IEC/EN 61095 25 A 50 Hz AC-7A 30000 cycles IEC/EN 61095 8.5 A 50 Hz AC-7B 30000 cycles IEC/EN 61095 50 Hz AC-7C 100000 cycles EN/IEC 60947-4-1 50 Hz AC-1 30000 cycles EN/IEC 60947-4-1 50 Hz AC-3 30000 cycles EN/IEC 60947-4-1 50 Hz AC-5a 30000 cycles EN/IEC 60947-4-1 50 Hz AC-5b |
| Connections - terminals | Power circuit: tunnel type terminals2 cable(s) 2.5 mm² flexible Power circuit: tunnel type terminals1 cable(s) 6 mm² rigid Control circuit: tunnel type terminals2 cable(s) 2.5 mm² flexible Control circuit: tunnel type terminals2 cable(s) 1.5 mm² rigid |
| Tightening torque | 0.8 N.m |
| Wire stripping length | 10 mm |
| Product compatibility | No auxiliary |
| Compatibility code | CT |

This Acti 9 iATLm is reliable latched control auxiliary. Is operates with 12VAC to 240VAC control voltage. Mounting is performed on the right of iTL impulse relay with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is associated with iTL impulse relays to allow latched type control orders from a changeover contact. This product is compliant with EN/IEC 60669-2-2.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Device short name | iATLm |
| Product or component type | Latched control auxiliary |
| [Uc] control circuit voltage | 12...240 V AC 50/60 Hz maintained |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 440 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Remote control type | 2 entries for switch |
| Mounting mode | Fixed, on right side of TL |
| Mounting support | DIN rail |
| 9 mm pitches | 1 |
| Height | 81 mm |
| Width | 9 mm |
| Depth | 69 mm |
| Colour | White |
| Connections - terminals | Tunnel type terminals0.5â¦4 mm² - rigid Tunnel type terminals0.5â¦4 mm² - rigid - with cable end Tunnel type terminals1â¦4 mm² - flexible Tunnel type terminals1â¦4 mm² - flexible - with cable end |
| Wire stripping length | 11 mm |
| Tightening torque | 1 N.m |
| Range compatibility | Acti9 iTL Acti9 iTLi Acti9 iTLs |
| Product compatibility | ITL (16 A) ITL (32 A) |