Contactors

10178 products

Showing 10105 - 10128 of 10178 products

Showing 10105 - 10128 of 10178 products
View
General Electric Stock Image
General Electric CR124Y0A28274 General Electric
Sale price 2,668.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

General Electric Stock Image
General Electric CR205G000DFC General Electric
Sale price 10,594.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

General Electric Stock Image
General Electric CR208C100DMD General Electric
Sale price 2,287.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

General Electric Stock Image
General Electric CR151D20108 General Electric
Sale price 2,472.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

General Electric Stock Image
General Electric CR307F2044EFBTL General Electric
Sale price 13,814.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

General Electric Stock Image
General Electric CR308C1042TAATLJ General Electric
Sale price 10,540.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

General Electric Stock Image
General Electric CR206J100ACA General Electric
Sale price 2,271.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Eaton Stock Image
Eaton DILM400-S Eaton
Sale price 13,814.00 kr
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Cutler Hammer Stock Image
Cutler Hammer XTCE300M22TD Cutler Hammer
Sale price 17,945.00 kr
Only 3 units left
Buy the Cutler-Hammer XTCE300M22TD Contactor/Motor Starter - an industrial motor switching device for reliable AC motor start/stop control. Features high mechanical and electrical endurance, auxiliary contacts, and standard mounting. The Cutler-Hammer XTCE300M22TD is a direct replacement for existing motor control installations.
Cutler Hammer Stock Image
Cutler Hammer AN16GN0AC Cutler Hammer
Sale price 13,455.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Cutler Hammer Stock Image
Cutler Hammer C25LNE3360A Cutler Hammer
Sale price 75,024.00 kr
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Cutler Hammer Stock Image
Cutler Hammer AN16NN0 Cutler Hammer
Sale price 96,459.00 kr
Only 9 units left
Motor Starter NEMA Size 4
Cutler Hammer Stock Image
Cutler Hammer AN16TN0A Cutler Hammer
Sale price 120,560.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Cutler Hammer Stock Image
Cutler Hammer AN16UN0A Cutler Hammer
Sale price 261,685.00 kr
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Cutler Hammer Stock Image
Cutler Hammer XTCE185H22C Cutler Hammer
Sale price 13,738.00 kr
Only 5 units left
Buy the Cutler-Hammer XTCE185H22C - a genuine Cutler-Hammer industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Cutler-Hammer XTCE185H22C is a direct drop-in replacement for existing installations and ships ready for integration.
Cutler Hammer Stock Image
Cutler Hammer XTCE225H22T Cutler Hammer
Sale price 10,289.00 kr
Only 3 units left
Buy the Cutler-Hammer XTCE225H22T Contactor/Motor Starter - an industrial motor switching device for reliable AC motor start/stop control. Features high mechanical and electrical endurance, auxiliary contacts, and standard mounting. The Cutler-Hammer XTCE225H22T is a direct replacement for existing motor control installations.
Cutler Hammer Stock Image
Cutler Hammer AN16TN0AB Cutler Hammer
Sale price 120,560.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Cutler Hammer Stock Image
Cutler Hammer XTCE185H22A Cutler Hammer
Sale price0.00 kr
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Cutler Hammer Stock Image
Cutler Hammer AN56GN0AB Cutler Hammer
Sale price 35,194.00 kr
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

1SBL236005R2100 ABB - AF26Z-30-00K-21
ABB 1SBL236005R2100 ABB - AF26Z-30-00K-21
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
45 mm
Product Net Depth / Length:
86 mm
Product Net Height:
92.3 mm
Product Net Weight:
0.355 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 45 A
(690 V) 60 °C 40 A
(690 V) 70 °C 32 A
(690 V) 40 °C 45 A
(690 V) 60 °C 40 A
(690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 26 A
(440 V) 60 °C 26 A
(500 V) 60 °C 23 A
(690 V) 60 °C 17 A
(380 / 400 V) 60 °C 26 A
(220 / 230 / 240 V) 60 °C 26 A
(415 V) 60 °C 26 A
(440 V) 60 °C 26 A
(500 V) 60 °C 23 A
(690 V) 60 °C 17 A
(380 / 400 V) 60 °C 26 A
(220 / 230 / 240 V) 60 °C 26 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 26 A
(440 V) 60 °C 26 A
(500 V) 60 °C 23 A
(690 V) 60 °C 17 A
(380 / 400 V) 60 °C 26 A
(220 / 230 / 240 V) 60 °C 26 A
(415 V) 60 °C 26 A
(440 V) 60 °C 26 A
(500 V) 60 °C 23 A
(690 V) 60 °C 17 A
(380 / 400 V) 60 °C 26 A
(220 / 230 / 240 V) 60 °C 26 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 45 A
(110 V) 2 Poles in Series, 60 °C 40 A
(110 V) 2 Poles in Series, 70 °C 32 A
(110 V) 3 Poles in Series, 40 °C 45 A
(110 V) 3 Poles in Series, 60 °C 40 A
(110 V) 3 Poles in Series, 70 °C 32 A
(220 V) 3 Poles in Series, 40 °C 45 A
(220 V) 3 Poles in Series, 60 °C 40 A
(220 V) 3 Poles in Series, 70 °C 32 A
(72 V) 1-Pole, 40 °C 45 A
(72 V) 1-Pole, 60 °C 40 A
(72 V) 1-Pole, 70 °C 32 A
(72 V) 2 Poles in Series, 40 °C 45 A
(72 V) 2 Poles in Series, 60 °C 40 A
(72 V) 2 Poles in Series, 70 °C 32 A
(72 V) 3 Poles in Series, 40 °C 45 A
(72 V) 3 Poles in Series, 60 °C 40 A
(72 V) 3 Poles in Series, 70 °C 32 A
(110 V) 2 Poles in Series, 40 °C 45 A
(110 V) 2 Poles in Series, 60 °C 40 A
(110 V) 2 Poles in Series, 70 °C 32 A
(110 V) 3 Poles in Series, 40 °C 45 A
(110 V) 3 Poles in Series, 60 °C 40 A
(110 V) 3 Poles in Series, 70 °C 32 A
(220 V) 3 Poles in Series, 40 °C 45 A
(220 V) 3 Poles in Series, 60 °C 40 A
(220 V) 3 Poles in Series, 70 °C 32 A
(72 V) 1-Pole, 40 °C 45 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 45 A
(110 V) 2 Poles in Series, 60 °C 40 A
(110 V) 2 Poles in Series, 70 °C 32 A
(110 V) 3 Poles in Series, 40 °C 45 A
(110 V) 3 Poles in Series, 60 °C 40 A
(110 V) 3 Poles in Series, 70 °C 32 A
(220 V) 3 Poles in Series, 40 °C 45 A
(220 V) 3 Poles in Series, 60 °C 40 A
(220 V) 3 Poles in Series, 70 °C 32 A
(72 V) 1-Pole, 40 °C 45 A
(72 V) 1-Pole, 60 °C 40 A
(72 V) 1-Pole, 70 °C 32 A
(72 V) 2 Poles in Series, 40 °C 45 A
(72 V) 2 Poles in Series, 60 °C 40 A
(72 V) 2 Poles in Series, 70 °C 32 A
(72 V) 3 Poles in Series, 40 °C 45 A
(72 V) 3 Poles in Series, 60 °C 40 A
(72 V) 3 Poles in Series, 70 °C 32 A
(110 V) 2 Poles in Series, 40 °C 45 A
(110 V) 2 Poles in Series, 60 °C 40 A
(110 V) 2 Poles in Series, 70 °C 32 A
(110 V) 3 Poles in Series, 40 °C 45 A
(110 V) 3 Poles in Series, 60 °C 40 A
(110 V) 3 Poles in Series, 70 °C 32 A
(220 V) 3 Poles in Series, 40 °C 45 A
(220 V) 3 Poles in Series, 60 °C 40 A
(220 V) 3 Poles in Series, 70 °C 32 A
(72 V) 1-Pole, 40 °C 45 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 45 A
(110 V) 2 Poles in Series, 60 °C 40 A
(110 V) 2 Poles in Series, 70 °C 32 A
(110 V) 3 Poles in Series, 40 °C 45 A
(110 V) 3 Poles in Series, 60 °C 40 A
(110 V) 3 Poles in Series, 70 °C 32 A
(220 V) 3 Poles in Series, 40 °C 20 A
(220 V) 3 Poles in Series, 60 °C 20 A
(220 V) 3 Poles in Series, 70 °C 20 A
(72 V) 1-Pole, 40 °C 20 A
(72 V) 1-Pole, 60 °C 20 A
(72 V) 1-Pole, 70 °C 20 A
(72 V) 2 Poles in Series, 40 °C 45 A
(72 V) 2 Poles in Series, 60 °C 40 A
(72 V) 2 Poles in Series, 70 °C 32 A
(72 V) 3 Poles in Series, 40 °C 45 A
(72 V) 3 Poles in Series, 60 °C 40 A
(72 V) 3 Poles in Series, 70 °C 32 A
(110 V) 2 Poles in Series, 40 °C 45 A
(110 V) 2 Poles in Series, 60 °C 40 A
(110 V) 2 Poles in Series, 70 °C 32 A
(110 V) 3 Poles in Series, 40 °C 45 A
(110 V) 3 Poles in Series, 60 °C 40 A
(110 V) 3 Poles in Series, 70 °C 32 A
(220 V) 3 Poles in Series, 40 °C 20 A
(220 V) 3 Poles in Series, 60 °C 20 A
(220 V) 3 Poles in Series, 70 °C 20 A
(72 V) 1-Pole, 40 °C 20 A
Rated Operational Power AC-3 (Pe):
(415 V) 11 kW
(440 V) 15 kW
(500 V) 15 kW
(690 V) 15 kW
(380 / 400 V) 11 kW
(220 / 230 / 240 V) 6.5 kW
(415 V) 11 kW
(440 V) 15 kW
(500 V) 15 kW
(690 V) 15 kW
(380 / 400 V) 11 kW
(220 / 230 / 240 V) 6.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 11 kW
(440 V) 15 kW
(500 V) 15 kW
(690 V) 15 kW
(380 / 400 V) 11 kW
(220 / 230 / 240 V) 6.5 kW
(415 V) 11 kW
(440 V) 15 kW
(500 V) 15 kW
(690 V) 15 kW
(380 / 400 V) 11 kW
(220 / 230 / 240 V) 6.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Power Loss:
at Rated Operating Conditions AC-1 per Pole 2 W
at Rated Operating Conditions AC-3 per Pole 0.66 W
at Rated Operating Conditions AC-1 per Pole 2 W
at Rated Operating Conditions AC-3 per Pole 0.66 W
Operate Time:
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 1 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 6 mm²
Flexible 1/2x 1 ... 6 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 4 ... 10 mm²
Flexible with Ferrule 1/2x 1 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 6 mm²
Flexible 1/2x 1 ... 6 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 4 ... 10 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm²
Flexible 1/2x 0.5 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.5 ... 1.5 mm²
Flexible 1/2x 0.5 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 14 mm
Control Circuit 10 mm
Main Circuit 14 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type:
Push-in Spring Terminals
Product Name:
Block Contactor

Technical UL/CSA

NEMA Size:
1
Continuous Current Rating NEMA:
27 A
Horsepower Rating NEMA:
(115 V AC) Single Phase 2 Hp
(200 V AC) Three Phase 7-1/2 Hp
(230 V AC) Single Phase 3 Hp
(230 V AC) Three Phase 7-1/2 Hp
(460 V AC) Three Phase 10 Hp
(575 V AC) Three Phase 10 Hp
(115 V AC) Single Phase 2 Hp
(200 V AC) Three Phase 7-1/2 Hp
(230 V AC) Single Phase 3 Hp
(230 V AC) Three Phase 7-1/2 Hp
(460 V AC) Three Phase 10 Hp
(575 V AC) Three Phase 10 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 42 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 2 hp
(200 ... 208 V AC) Three Phase 7-1/2 hp
(220 ... 240 V AC) Three Phase 7-1/2 hp
(240 V AC) Single Phase 3 hp
(440 ... 480 V AC) Three Phase 15 hp
(550 ... 600 V AC) Three Phase 20 hp
(120 V AC) Single Phase 2 hp
(200 ... 208 V AC) Three Phase 7-1/2 hp
(220 ... 240 V AC) Three Phase 7-1/2 hp
(240 V AC) Single Phase 3 hp
(440 ... 480 V AC) Three Phase 15 hp
(550 ... 600 V AC) Three Phase 20 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-8 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-8 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Full Load Amps Motor Use:
(120 V AC) Single Phase 24 A
(200 ... 208 V AC) Three Phase 25.3 A
(220 ... 240 V AC) Three Phase 22 A
(240 V AC) Single Phase 17 A
(440 ... 480 V AC) Three Phase 21 A
(550 ... 600 V AC) Three Phase 22 A
(120 V AC) Single Phase 24 A
(200 ... 208 V AC) Three Phase 25.3 A
(220 ... 240 V AC) Three Phase 22 A
(240 V AC) Single Phase 17 A
(440 ... 480 V AC) Three Phase 21 A
(550 ... 600 V AC) Three Phase 22 A

Environmental

Ambient Air Temperature:
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Vibrations:
4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard - 86 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28 %

Certificates and Declarations

UL Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
93 mm
Package Level 1 Depth / Length:
86 mm
Package Level 1 Height:
45 mm
Package Level 1 Gross Weight:
0.37 kg
Package Level 1 EAN:
3471523156418
Package Level 2 Units:
box 21 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
315 mm
Package Level 2 Gross Weight:
16.65 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707898
E-Number (Sweden):
3210617
1SBL181001R8610 ABB - A16-30-10 400-415V 50Hz / 415-440V 60Hz

A16-30-10 400-415V 50Hz / 415-440V 60Hz Contactor

1SBL387001R1300 ABB - AF65-30-00-13
ABB 1SBL387001R1300 ABB - AF65-30-00-13
Sale price 1,620.00 kr
Only 6 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
55 mm
Product Net Depth / Length:
111 mm
Product Net Height:
125.5 mm
Product Net Weight:
0.95 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
(690 V) 40 °C 105 A
(690 V) 60 °C 90 A
(690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current AC-3e (Ie):
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
(415 V) 60 °C 65 A
(440 V) 60 °C 65 A
(500 V) 60 °C 55 A
(690 V) 60 °C 39 A
(380 / 400 V) 60 °C 65 A
(220 / 230 / 240 V) 60 °C 65 A
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
(72 V) 1-Pole, 60 °C 90 A
(72 V) 1-Pole, 70 °C 80 A
(72 V) 2 Poles in Series, 40 °C 105 A
(72 V) 2 Poles in Series, 60 °C 90 A
(72 V) 2 Poles in Series, 70 °C 80 A
(72 V) 3 Poles in Series, 40 °C 105 A
(72 V) 3 Poles in Series, 60 °C 90 A
(72 V) 3 Poles in Series, 70 °C 80 A
(110 V) 2 Poles in Series, 40 °C 105 A
(110 V) 2 Poles in Series, 60 °C 90 A
(110 V) 2 Poles in Series, 70 °C 80 A
(110 V) 3 Poles in Series, 40 °C 105 A
(110 V) 3 Poles in Series, 60 °C 90 A
(110 V) 3 Poles in Series, 70 °C 80 A
(220 V) 3 Poles in Series, 40 °C 105 A
(220 V) 3 Poles in Series, 60 °C 90 A
(220 V) 3 Poles in Series, 70 °C 80 A
(72 V) 1-Pole, 40 °C 105 A
Rated Operational Power AC-3 (Pe):
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(400 V) 30 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Operational Power AC-3e (Pe):
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
(415 V) 37 kW
(440 V) 37 kW
(500 V) 37 kW
(690 V) 37 kW
(380 / 400 V) 30 kW
(220 / 230 / 240 V) 18.5 kW
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
6 kV
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Loss:
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
at Rated Operating Conditions AC-1 per Pole 7 W
at Rated Operating Conditions AC-3 per Pole 2.7 W
Operate Time:
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw Driver:
Pozidriv PZ
Tightening Torque:
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
General Use Rating UL/CSA:
(600 V AC) 90 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
(120 V AC) Single Phase 5 hp
(200 ... 208 V AC) Three Phase 20 hp
(220 ... 240 V AC) Three Phase 25 hp
(240 V AC) Single Phase 15 hp
(440 ... 480 V AC) Three Phase 50 hp
(550 ... 600 V AC) Three Phase 60 hp
Connecting Capacity Main Circuit UL/CSA:
Rigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSA:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Full Load Amps Motor Use:
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(120 V AC) Single Phase 56 A
(200 ... 208 V AC) Three Phase 62.1 A
(220 ... 240 V AC) Three Phase 68 A
(240 V AC) Single Phase 68 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A

Environmental

Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations:
3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
e9b43d1b-dd25-4049-9500-e96dae069812 France
Simplified SCIP:
4f8f9097-4d3f-40f2-ab71-de08f01520c1 Poland
3c9c39cd-1f36-40cb-bd2e-cbdb489ca0d3 Norway
7ee99c18-1a43-42d9-8de2-80aefe2bc295 Spain
5c5a0e9f-1f11-470e-a9eb-5d5eae2ce325 Germany
49cec99c-43cf-4caf-a582-f7fddb48fa78 Finland
242d911d-693f-4802-9162-38f75bfbf158 Italy
034afccd-5d3c-4f17-a5d4-41c3d33662aa Germany
a7cbf824-baa3-405d-b1f0-9b43b9a5c174 Netherlands
9112a6a0-74e8-4e47-89ba-c82c10a2be98 Greece
7b2d5a1d-bfe8-4627-b7a9-4817986425e5 Denmark
d83d4331-2a05-4711-a887-a739649a699a Germany
2c45b13f-ccd4-438b-893d-a1fd3a931798 Czech Republic
4935f90b-1a61-4100-9d9b-b7f0480976a4 Poland
2d663d0b-9e40-4dcd-b3b3-908840fa7414 Sweden
26f7d5b6-c240-4975-ad30-c60b9a55b4ec Poland
cb6c25f4-3570-4f71-9b53-994499d0f1f5 France
a031f8e6-578e-42c3-85bd-8ce5128a8b44 Portugal
22cf40dd-3fdc-46aa-aa67-9a7c3429b359 Hungary
5b11f3b5-236c-45a1-bf65-22616ac89baf Belgium
c918f036-cd2d-40ce-9a0a-0d21cc7e8ede Bulgaria
48dcdcfb-6ae6-4ee9-8d97-071323301bbd Sweden
7f440d90-9fa6-45bc-8dd8-3fc8af21a148 Germany
3bada221-ca3f-45e1-be5a-cc897c807c4d Germany
4f8f9097-4d3f-40f2-ab71-de08f01520c1 Poland
3c9c39cd-1f36-40cb-bd2e-cbdb489ca0d3 Norway
7ee99c18-1a43-42d9-8de2-80aefe2bc295 Spain
5c5a0e9f-1f11-470e-a9eb-5d5eae2ce325 Germany
49cec99c-43cf-4caf-a582-f7fddb48fa78 Finland
242d911d-693f-4802-9162-38f75bfbf158 Italy
034afccd-5d3c-4f17-a5d4-41c3d33662aa Germany
a7cbf824-baa3-405d-b1f0-9b43b9a5c174 Netherlands
9112a6a0-74e8-4e47-89ba-c82c10a2be98 Greece
7b2d5a1d-bfe8-4627-b7a9-4817986425e5 Denmark
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutions:
Yes
End Of Life Disassembling Instructions:
Sustainable Material Content in Packaging (wt. %):
FSC Recycled Paper - 94.6 %
Sustainable Material Content in Product (wt. %):
Recycled Metal - 28.2 %

Certificates and Declarations

A2L Certificate – UL:
BV Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
150 mm
Package Level 1 Depth / Length:
150 mm
Package Level 1 Height:
97 mm
Package Level 1 Gross Weight:
1.05 kg
Package Level 1 EAN:
3471523132634
Package Level 2 Units:
box 10 piece
Package Level 2 Width:
250 mm
Package Level 2 Depth / Length:
300 mm
Package Level 2 Height:
300 mm
Package Level 2 Gross Weight:
10.5 kg

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
ETIM 9:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E-Number (Finland):
3707048
E-Number (Sweden):
3210045
1SBL411022R5800 ABB - UA75-30-00 660-690V 50Hz

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Popular Downloads

Dimensions

Product Net Width:
70 mm
Product Net Depth / Length:
108 mm
Product Net Height:
110 mm
Product Net Weight:
1.16 kg

Technical

Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Number of Poles:
3P
Standards:
IEC/EN 60947-1, IEC/EN 60947-4-1
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power AC-6b (Pe):
(230 / 240 V) 40 °C, 50 / 60 Hz 30 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 30 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 22 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 50 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 39 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 50 kvar
(440 V) 40 °C, 50 / 60 Hz 55 kvar
(440 V) 55 °C, 50 / 60 Hz 53 kvar
(440 V) 70 °C, 50 / 60 Hz 43 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 62 kvar
(500 / 550 V) 55 °C, 50 / 60 Hz 62 kvar
(500 / 550 V) 70 °C, 50 / 60 Hz 47.5 kvar
(690 V) 40 °C, 50 / 60 Hz 75 kvar
(690 V) 55 °C, 50 / 60 Hz 75 kvar
(690 V) 70 °C, 50 / 60 Hz 65 kvar
(230 / 240 V) 40 °C, 50 / 60 Hz 30 kvar
(230 / 240 V) 55 °C, 50 / 60 Hz 30 kvar
(230 / 240 V) 70 °C, 50 / 60 Hz 22 kvar
(400 / 415 V) 40 °C, 50 / 60 Hz 50 kvar
(400 / 415 V) 70 °C, 50 / 60 Hz 39 kvar
(400 / 415 V) 55 °C, 50 / 60 Hz 50 kvar
(440 V) 40 °C, 50 / 60 Hz 55 kvar
(440 V) 55 °C, 50 / 60 Hz 53 kvar
(440 V) 70 °C, 50 / 60 Hz 43 kvar
(500 / 550 V), 40 °C, 50 / 60 Hz 62 kvar
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Mechanical Durability:
10 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (Uc):
50 Hz 660 ... 690 V
Coil Consumption:
Average Holding Value 50 Hz 18 V·A
Average Pull-in Value 50 Hz 180 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Average Holding Value 50 Hz 18 V·A
Average Pull-in Value 50 Hz 180 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A
Operate Time:
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 8 ... 27 ms
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) :
2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit:
Flexible with Cable End 6 ... 16 mm²
Rigid Cable 6 ... 25 mm²
Flexible with Cable End 6 ... 16 mm²
Rigid Cable 6 ... 25 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles:
M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
Terminal Type:
Screw Terminals
Product Name:
Block Contactor

Environmental

Ambient Air Temperature:
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Near Contactor for Operation in Free Air (Uc) -40 ... 70 °C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Pollution Degree:
3

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

GOST Certificate:
UL Listing Card:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
140 mm
Package Level 1 Depth / Length:
146 mm
Package Level 1 Height:
96 mm
Package Level 1 Gross Weight:
1.16 kg
Package Level 1 EAN:
3471522097583

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC001079 - Capacitor contactor
ETIM 8:
EC001079 - Capacitor contactor
ETIM 9:
EC001079 - Capacitor contactor
eClass:
V11.0 : 27371006
UNSPSC:
39121529
1SBN060100R1000 ABB - RA4
ABB 1SBN060100R1000 ABB - RA4
Sale price0.00 kr
Sold Out

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900

Dimensions

Product Net Width:
44.8 mm
Product Net Depth / Length:
31.16 mm
Product Net Height:
40.5 mm
Product Net Weight:
0.04 kg

Technical

Standards:
IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1-13, CSA C22.2 No. 60947-5-1-14
Rated Frequency (f):
Control Circuit 50 / 60 Hz
Rated Insulation Voltage (Ui):
acc. to IEC 60947-5-1 250 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 250 V AC 50/60 Hz
acc. to IEC 60947-5-1 250 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 250 V AC 50/60 Hz
Electrical Durability:
2000000 cycle
Maximum Electrical Switching Frequency:
600 cycles per hour
Rated Control Circuit Voltage (Uc):
DC Operation 24 V
Connecting Capacity Control Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length:
Control Circuit 10 mm
Recommended Screw Driver:
Control Circuit Pozidriv 2
Control Circuit Flat Ø 5.5 mm
Control Circuit Pozidriv 2
Control Circuit Flat Ø 5.5 mm
Tightening Torque:
Control Circuit 1.2 N·m
Terminal Type:
Screw Terminals
Suitable For:
AF09
AF09Z
AF12
AF12Z
AF16
AF16Z
AF26
AF26Z
AF30
AF30Z
AF38
AF38Z
AF40
AF52
AF65
AF80
AF96
NF22E
NFZ22E
NF31E
NFZ31E
NF40E
NFZ40E
NF44E
NFZ44E
NF53E
NFZ53E
NF62E
NFZ62E
NF71E
NFZ71E
NF80E
NFZ80E
NF33/11
NF51/11
AF09
AF09Z
AF12
AF12Z
AF16
AF16Z
AF26
AF26Z
AF30
AF30Z
Product Name:
Interface Relay

Technical UL/CSA

Connecting Capacity UL/CSA:
Conductor 18 ... 14 AWG
Tightening Torque UL/CSA:
Control Circuit 11 in·lb

Environmental

Ambient Air Temperature:
Close to Contactor for Storage -40 ... 70 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -25 ... +60 °C
Near Contactor for Operation in Free Air (Uc) at 24 VDC -25 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -25 ... +60 °C
Near Contactor for Operation in Free Air (Uc) at 24 VDC -25 ... 70 °C
Climatic Withstand:
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible:
Without Derating 3000 m
Pollution Degree:
3

Material Compliance

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
54 mm
Package Level 1 Depth / Length:
54 mm
Package Level 1 Height:
47 mm
Package Level 1 Gross Weight:
0.04 kg
Package Level 1 EAN:
3471523131149

External Classifications and Standards

ETIM 7:
EC002498 - Accessories for low-voltage switch technology
ETIM 8:
EC002498 - Accessories/spare parts for low-voltage switch technology
ETIM 9:
EC002498 - Accessories/spare parts for low-voltage switch technology
UNSPSC:
39122331
IDEA Granular Category Code (IGCC):
5367 >> Control relay

Recently viewed