This Harmony RM22JA control relay allows monitoring of current control. This modular control relay is ideal for monitoring of electrical values and current variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony Control Relays |
| Relay Type | Current control relay |
| Product or Component Type | Current control relay |
| Relay name | RM22JA |
| Relay monitored parameters | Overcurrent or undercurrent detection Overcurrent or undercurrent in window mode |
| time delay | Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Switching capacity in VA | 2000 VA |
| Minimum switching current | 10 mA 5 V DC |
| Maximum switching current | 8 A AC |
| Maximum power consumption in VA | 3.5 VA |
| Measurement range | 4 mA...1 A current AC/DC 50/60 Hz |
| Utilisation category | AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1 |
| Contacts type and composition | 2 C/O |
Complementary
| Characteristic | Value(s) |
|---|---|
| Reset time | 1500 ms at maximum voltage |
| Maximum switching voltage | 250 V AC |
| Supply voltage limits | 20.4â¦264 V AC/DC |
| operating voltage tolerance | - 15 % + 10 % Un |
| Maximum power consumption in W | 1.5 W DC |
| Resistance across terminals | 2.5 Ohm E1-M terminals 0.5 Ohm E2-M terminals 0.1 Ohm E3-M terminals |
| Output contacts | 2 C/O |
| nominal output current | 8 A |
| Maximum measuring cycle | 100 ms measurement cycle as true rms value |
| Internal input resistance | 0.5 Ohm 2.5 Ohm 0.1 Ohm |
| Setting accuracy of the switching threshold | +/- 10 % of the full scale |
| Switching threshold drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range |
| Setting accuracy of time delay | 10 P |
| Time delay drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range |
| Hysteresis | 5â¦50 % adjustable threshold setting 3 % fixed full scale for window mode |
| delay at power up | 0.3 s |
| Repeat accuracy | +/- 0.5 % input and measurement circuit +/- 0.2 % time delay |
| Measurement error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
| Response time | <= 500 ms |
| Threshold setting | 10...100 % |
| Overvoltage category | III conforming to IEC 60664-1 III conforming to UL 508 |
| Insulation resistance | > 100 MOhm 500 V DC IEC 60255-27 |
| Insulation | Between supply and measurement |
| Connections - terminals | Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end |
| Tightening torque | 5.3â¦8.9 lbf.in (0.6â¦1 N.m) IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Local signalling | LED (yellow) for relay ON LED (green) for power ON |
| Mounting support | 35 mm DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 10000000 cycles |
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
| Safety reliability data | MTTFd = 296.8 years B10d = 270000 |
| Contacts material | Cadmium free |
| Width | 0.9 in (22.5 mm) |
| Control Type | With test button |
| Product Weight | 0.24 lb(US) (0.11 kg) |
All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.
If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.
In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.
PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.
Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.
PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.


"Fast service for obsolete parts"
Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!
Buyer at GE Health

"Helping us move projects forward"
With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.
Buyer at E-Merge Systems – A Rockwell Integrator