Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys |
| product name | TeSys T |
| Device short name | LTMR |
| Product or Component Type | Motor controller |
| Device Application | Equipment monitoring and control |
| Measurement current | 5â¦100 A |
| [Us] rated supply voltage | 24 V DC |
| Current Consumption | 56...127 mA |
| Supply voltage limits | 20.4â¦26.24 V DC |
| Communication Port Protocol | CANopen |
| Bus type | CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 |
| [Uimp] rated impulse withstand voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
| Short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Associated fuse rating | 4 A gG output 0.5 A gG control circuit |
| Protection Type | Thermal protection Reverse polarity protection Phase unbalance Phase failure Overload (long time) Thermal overload protection Load fluctuation Power factor variation Earth-leakage protection Locked rotor Overload |
| Network and machine diagnosis type | Motor control command recording Trip context information Starting current and time Event recording Fault recording Remaining operating time before overload tripping Phase fault and earth fault trip counters Waiting time after overload tripping Running hours counter/operating time Trip history information |
| Logic input number | 6 |
| Input current | 7 mA |
| Current state 0 guaranteed | Logic input < 5 V <= 15 mA 5 ms |
| Current state 1 guaranteed | Logic input < 15 V 2...15 mA 15 ms |
| maximum output switching frequency | 2 Hz |
| Load current | 5 A 250 V AC logic output 5 A 30 V DC logic output |
| Permissible power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Maximum operating rate | 1800 cyc/h |
| Contacts type and composition | 1 NO + 1 NC fault signal 3 NO |
| Metering type | Imbalance current Earth-fault current Temperature Phase current I1, I2, I3 RMS Average current Iavg |
| Measurement accuracy | 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02 current |
| Overvoltage category | III |
| Connection pitch | 0.20 in (5.08 mm) |
| Connections - terminals | Control circuit connector 1 0.0004â¦0.004 in² (0.25â¦2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003â¦0.004 in² (0.2â¦2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004â¦0.004 in² (0.25â¦2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003â¦0.004 in² (0.2â¦2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008â¦0.002 in² (0.5â¦1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1 mm²) AWG 24...AWG 14)solid without cable end |
| Tightening torque | Control circuit: 4.4â¦5.3 lbf.in (0.5â¦0.6 N.m) flat screwdriver 0.1 in (3 mm) |
| pollution degree | 3 |
| Electromagnetic compatibility | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 |
| Width | 3.6 in (91 mm) |
| Height | 2.4 in (61 mm) |
| Depth | 4.8 in (122.5 mm) |
| Product Weight | 1.17 lb(US) (0.53 kg) |
| Web services | Web server |
| Compatibility code | LTMR |
All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.
If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.
In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.
PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.
Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.
PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.


"Fast service for obsolete parts"
Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!
Buyer at GE Health

"Helping us move projects forward"
With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.
Buyer at E-Merge Systems – A Rockwell Integrator