ABB

1SFA898210R7000 ABB

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Instructions and Manuals (Part 2):
Instructions and Manuals (Part 3):
EPLAN Data:
Wiring Diagram:

Dimensions

Product Net Width:
199 mm
Product Net Height:
377 mm
Product Net Depth / Length:
283 mm
Product Net Weight:
7 kg

Technical

Rated Operational Voltage:
208 ... 690 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
Rated Operational Current - In-Line Connection (Ie):
142 A
Rated Operational Power - Inside Delta Connection:
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
Rated Operational Current - Inside Delta Connection:
245 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 %
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Main Circuit:
Hole Diameter 8.5 mm
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 14 N·m
Product Main Type:
PSTX142
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 690 V
Tightening Torque UL/CSA:
Main Circuit 123.9

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
7ac58c93-1935-4f9a-a1cf-b53a16b37b9e Sweden
Simplified SCIP:
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
7f3a5266-46a0-4bd5-8956-4cb28cf71584 France
86667217-7850-4464-bc67-0989310e6d51 Belgium
8945c0b2-d687-4890-84ec-bfd8b63a6873 Belgium
8de00583-51c1-4c15-921d-cf224e8d6a7b Greece
95cdfb74-c4de-43c9-a407-a32f70a6bc98 Poland
99ee119e-fa5f-497c-961a-89051ecf6b00 Poland
b797e4b8-7518-46e0-ab6f-0e4d1c2aa87a Germany
bf3d4a73-1b3c-451a-b266-236ba7136eed Hungary
c0ef8ad3-55b8-4056-8a87-a33727de619c France
c6ec4ad1-bc67-4e74-b1bd-5e37556b8b4e Norway
c7da1248-c80a-4811-a6a8-195c040a4df8 Sweden
c83eb676-1ff4-412a-af63-9f6fe9b3a126 Poland
c93a6f14-01b7-4e10-8eaf-7b935d98e077 Germany
d0f38e66-e5ff-4c69-a6b4-db6ed0a1dc9b Netherlands
d236d276-4f52-41a5-aad1-8b8367bd7a2b Portugal
de94f801-93d2-454f-b5a5-8d39e3193292 Spain
fa967b40-4d4f-4609-80c5-d1098a8f5331 Hungary
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

Container Information

Package Level 1 Width:
263 mm
Package Level 1 Depth / Length:
323 mm
Package Level 1 Height:
454 mm
Package Level 1 Gross Weight:
8.7 kg
Package Level 1 EAN:
7320500501450
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter

Sale price€1.739,95
1-year warranty
FREE WORDWIDE SHIPPING
Est. delivery between and  
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Condition:
€1.739,95
€0,00
€0,00

Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa
Description
Warranty
Shipping and Return

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Instructions and Manuals (Part 2):
Instructions and Manuals (Part 3):
EPLAN Data:
Wiring Diagram:

Dimensions

Product Net Width:
199 mm
Product Net Height:
377 mm
Product Net Depth / Length:
283 mm
Product Net Weight:
7 kg

Technical

Rated Operational Voltage:
208 ... 690 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
Rated Operational Current - In-Line Connection (Ie):
142 A
Rated Operational Power - Inside Delta Connection:
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
Rated Operational Current - Inside Delta Connection:
245 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 %
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Main Circuit:
Hole Diameter 8.5 mm
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 14 N·m
Product Main Type:
PSTX142
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 690 V
Tightening Torque UL/CSA:
Main Circuit 123.9

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
7ac58c93-1935-4f9a-a1cf-b53a16b37b9e Sweden
Simplified SCIP:
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
7f3a5266-46a0-4bd5-8956-4cb28cf71584 France
86667217-7850-4464-bc67-0989310e6d51 Belgium
8945c0b2-d687-4890-84ec-bfd8b63a6873 Belgium
8de00583-51c1-4c15-921d-cf224e8d6a7b Greece
95cdfb74-c4de-43c9-a407-a32f70a6bc98 Poland
99ee119e-fa5f-497c-961a-89051ecf6b00 Poland
b797e4b8-7518-46e0-ab6f-0e4d1c2aa87a Germany
bf3d4a73-1b3c-451a-b266-236ba7136eed Hungary
c0ef8ad3-55b8-4056-8a87-a33727de619c France
c6ec4ad1-bc67-4e74-b1bd-5e37556b8b4e Norway
c7da1248-c80a-4811-a6a8-195c040a4df8 Sweden
c83eb676-1ff4-412a-af63-9f6fe9b3a126 Poland
c93a6f14-01b7-4e10-8eaf-7b935d98e077 Germany
d0f38e66-e5ff-4c69-a6b4-db6ed0a1dc9b Netherlands
d236d276-4f52-41a5-aad1-8b8367bd7a2b Portugal
de94f801-93d2-454f-b5a5-8d39e3193292 Spain
fa967b40-4d4f-4609-80c5-d1098a8f5331 Hungary
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

Container Information

Package Level 1 Width:
263 mm
Package Level 1 Depth / Length:
323 mm
Package Level 1 Height:
454 mm
Package Level 1 Gross Weight:
8.7 kg
Package Level 1 EAN:
7320500501450
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Description
Warranty
Shipping and Return

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Instructions and Manuals (Part 2):
Instructions and Manuals (Part 3):
EPLAN Data:
Wiring Diagram:

Dimensions

Product Net Width:
199 mm
Product Net Height:
377 mm
Product Net Depth / Length:
283 mm
Product Net Weight:
7 kg

Technical

Rated Operational Voltage:
208 ... 690 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
(230 V) 37 kW
(400 V) 75 kW
(500 V) 90 kW
(690 V) 132 kW
Rated Operational Current - In-Line Connection (Ie):
142 A
Rated Operational Power - Inside Delta Connection:
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
at 230 V 75 kW
at 400 V 132 kW
at 500 V 160 kW
at 690 V 220 kW
Rated Operational Current - Inside Delta Connection:
245 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 %
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Main Circuit:
Hole Diameter 8.5 mm
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 14 N·m
Product Main Type:
PSTX142
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
(200 ... 208 V AC) Three Phase 40 Hp
(220 ... 240 V AC) Three Phase 50 Hp
(440 ... 480 V AC) Three Phase 100 Hp
(550 ... 600 V AC) Three Phase 125 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 690 V
Tightening Torque UL/CSA:
Main Circuit 123.9

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP:
7ac58c93-1935-4f9a-a1cf-b53a16b37b9e Sweden
Simplified SCIP:
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
7f3a5266-46a0-4bd5-8956-4cb28cf71584 France
86667217-7850-4464-bc67-0989310e6d51 Belgium
8945c0b2-d687-4890-84ec-bfd8b63a6873 Belgium
8de00583-51c1-4c15-921d-cf224e8d6a7b Greece
95cdfb74-c4de-43c9-a407-a32f70a6bc98 Poland
99ee119e-fa5f-497c-961a-89051ecf6b00 Poland
b797e4b8-7518-46e0-ab6f-0e4d1c2aa87a Germany
bf3d4a73-1b3c-451a-b266-236ba7136eed Hungary
c0ef8ad3-55b8-4056-8a87-a33727de619c France
c6ec4ad1-bc67-4e74-b1bd-5e37556b8b4e Norway
c7da1248-c80a-4811-a6a8-195c040a4df8 Sweden
c83eb676-1ff4-412a-af63-9f6fe9b3a126 Poland
c93a6f14-01b7-4e10-8eaf-7b935d98e077 Germany
d0f38e66-e5ff-4c69-a6b4-db6ed0a1dc9b Netherlands
d236d276-4f52-41a5-aad1-8b8367bd7a2b Portugal
de94f801-93d2-454f-b5a5-8d39e3193292 Spain
fa967b40-4d4f-4609-80c5-d1098a8f5331 Hungary
2c12831e-d227-4343-89cd-8ad9d0598b61 Croatia
2c8d8687-c1c6-45eb-96a8-f71342d2e1f0 Finland
2ef72255-8a48-4f8e-a7b1-313f04b94f51 Germany
347da50a-f271-4da7-8510-8026f1acdea3 Germany
440607c6-b08e-4d6d-bd83-61d6cb8a5e26 Estonia
58839739-518f-4286-8ac2-834169918879 Germany
59a2564a-7755-4843-a2aa-a3a56004e5e9 Denmark
602979df-6621-44e7-8b07-d529d35e25de Czech Republic
6b121e93-34c0-4cc5-8588-2cfd914a2297 Bulgaria
6be3dec0-f89a-43ab-a9bf-4fd7d32b2cfe Italy
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

Container Information

Package Level 1 Width:
263 mm
Package Level 1 Depth / Length:
323 mm
Package Level 1 Height:
454 mm
Package Level 1 Gross Weight:
8.7 kg
Package Level 1 EAN:
7320500501450
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator

You may also like

Recently viewed