Keyence Stock Image
Keyence GL-VM28HP Keyence
Sale price €604,95
Only 10 units left

Specifications

Model

GL-VM28HP

Beam axis spacing/Lens diameter

20 mm 0.79": ø5 ø0.197"

Number of beam axes

28

Total length

560 mm 22.05"

Detection height

540 mm 21.26"

Protection height

585 mm 23.03"

Minimum detectable object size

ø25 mm ø0.98" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

5.0

OFF→ON

48.6 *3

All blocked→ON

55.4 *4

With channel A or B

ON→OFF

13.7

OFF→ON

60.8 *3

All blocked→ON

79.6 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

87 *5

Receiver

98 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

53 *5

Receiver

59 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

370 g 13.06 oz

Receiver

380 g 13.41 oz

Total

750 g 26.47 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

keyence Stock Image
Keyence CL-L015N Keyence
Sale price €4.918,95
Only 3 units left

Specifications

Model

CL-L015N

Type

Optical unit

Head

CL-L015 *1

Reference distance

15 mm 0.59"

Reference measurement range

Measurement range

±1.3 mm ±0.05"

Linearity

±0.49 μm ±0.000019" *2

High precision measurement range

Measurement range

±0.5 mm ±0.02"

Linearity

±0.41 μm ±0.000016" *2

Resolution

0.25 μm 0.000010" *3

Spot diameter

ø300 μm ø0.0118"

Laser class

Optical unit

Class I

Sampling cycle

100/200/500/1000 μs (Adjustable 4-stage)

Environmental resistance

Enclosure rating

Head

IP67 (IEC60529)

Ambient light

Target surface illuminance: 30000 lux (Incandescent lamp)

Ambient temperature

0 to 50°C 32 to 122°F

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Head

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Optical unit

10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes

Shock resistance

15 G, 6 ms

Temperature characteristic

Head

0.005% of F.S./°C

Optical unit

0.015% of F.S./°C

Material

Head

Front: SUS, Rear: Aluminum

Optical unit

Polycarbonate

Weight

Head

Approx. 180 g 6.35 oz

Optical unit

Approx. 1600 g 3.53 lb

*1 Sensor head and optical unit are a matched pair. Not cross compatible.
*2 Value measured in displacement mode with KEYENCE reference workpiece (mirrored surface).
*3 Value measured using 16,384 average cycles with KEYENCE reference workpiece (mirrored surface).

FS-N41P Keyence
Keyence FS-N41P Keyence
Sale price €197,95
In stock, 24 units

Specifications

Model

FS-N41P

Type

Cable

Output

PNP

Main unit/expansion unit

Main unit

Response time

23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)

Number of control outputs

1

Number of external inputs

Light source LED

Transmitter side: Red, four-element LED (wavelength: 660 nm)

Control output

Open-collector, 30 V or less 100 mA or less per output,
100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit)
Residual voltage: 1.6 V or less (output current: 10 mA or less) /2.2 V or less (output current: 10 to 100 mA)

External input

Input time: 2 ms (ON) /20 ms (OFF) or longer*3

Unit expansion

Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

Mutual interference prevention

S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)

Power supply

Power voltage

10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4

Power consumption

During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)
ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V)
ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*5

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less

Ambient temperature

-20 °C -4 °F to +55 °C +131 °F (no freezing)*6

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes

Shock resistance

500 m/s2; 3 times each for X, Y, and Z axes

Case material

Main unit and cover: polycarbonate

Weight

Approx. 78 g

*1 Restrictions when S-HSPD is selected
Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.
Output timer, Limit Detection, and Display Gain cannot be used.
FULL cannot be selected for the ECO function.
*2 Restrictions when HSPD is selected
Display Gain cannot be used.
*3 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.
*4 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.
*5 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.
*6 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.
When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.
The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.
Exercise special care when installing the product in an airtight space.

Keyence Stock Image
Keyence OP-73880 Keyence
Sale price €105,95
Only 9 units left

Specifications

Model

OP-73880

Overview

Fixing bracket to fix DIN amplifier.

Applicable product

FS-V30/FS-N10/LV-N10/PS-N10 Series

Material

Polycarbonate

keyence Stock Image
Keyence OP-84388 Keyence
Sale price €484,95
Only 3 units left

Specifications

Model

OP-84388

Overview

Relay substrate unit for the replacement of dedicated SL-T11R for the relay terminal SL-V.

Applicable product

SL-T11R

Keyence Stock Image
Keyence CB-B3 Keyence
Sale price €189,95
In stock, 12 units

Specifications

Model

CB-B3*1

Type

Head cable

Cable min. bending R

22 mm 0.87"

Cable length

3 m 9.84'

Environmental resistance

Enclosure rating

IP67 (IEC60529)*2

Material

PVC

Weight

Approx. 250 g

*1 Regarding cable extension between the head and controller: Up to 2 cables can be connected with the CB-BxxE, and these cables should be kept to a total length of 30 m 98.4' or less.
*2 This value is from a case in which the sensor head has been connected. However, the controller side connector is not included.

keyence Stock Image
Keyence FD-XC8R3 Keyence
Sale price €462,95
Only 5 units left

Specifications

Model

FD-XC8R3

Supported diameter

Outer diameter of pipe: ø 8 0.31 "
Attachable range: ø 7.5 to 8.5 0.27 " to 0.33 "

Weight

Approx. 60 g

Keyence New Stock Image
Keyence OP-88305 Keyence
Sale price €189,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence FW-H10R Keyence
Sale price €300,95
Only 5 units left

Specifications

Model

FW-H10R

Type

Long range

Detecting area

150 to 1000 mm 5.9" to 39.4"*1

Response speed

1,000 ms

Temperature characteristics

0.06% of F.S./°C*2

Indicator lamp

Operation indicator (orange) x1 (Turns on when the target is within the detecting range.)

Dimensions

M18 x P1, Length= 104 mm 4.09"

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +70 °C -13 to 158 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Brass-nickel plating, PBT, Polyurethane, Polyamide resin

Accessories

M18 nut: 2, Head cable: 2 m 6.6', Standard Mounting Bracket (FW-B01)

Weight

Approx. 106 g

*1 Less stable zones of approx. 2% of F.S. exist at both ends of the detecting range.
*2 The errors for the indicated value at 25°C 77°F.

Keyence New Stock Image
Keyence GL-R1UB Keyence
Sale price €296,95
In stock, 12 units

Specifications

Model

GL-R1UB

Type

Interface Unit

Overview

Optional accessory that is necessary for performing GL-R settings and monitoring with a PC.

Applicable product

GL-R Series

Number included

1 unit

Material

Polycarbonate

Note

The USB cable to use in connecting the interface unit and a PC is not included. Use an A to miniB type USB cable (sold separately).

Weight

Approx. 10 g

Keyence Stock Image
Keyence GS-MA5M Keyence
Sale price €168,95
Only 10 units left

Specifications

Model

GS-MA5M

Type

Coding level: Low

Applicable model

Standard model GS-M5 Series

Keyence New Stock Image
Keyence NQ-MP8L Keyence
Sale price €555,95
Only 5 units left

Specifications

Model

NQ-MP8L

Network Specifications

Compatible Networks

EtherNet/IP™, PROFINET, Modbus/TCP

Communication Speed

10 Mbps/100 Mbps

Connector

M12 4-pin female D-code

Power Supply Specifications

Connector Type

Power supply port IN: M12 5-pin male L-code
Power supply port OUT: M12 5-pin female L-code

Power Voltage

18 to 30 VDC
(During IO-Link communication: 20.4 V to 28.8 V)

Allowable Current

V1 and V2: max. 9 A each
V1 and V2: 11 A in total

Current Consumption

V1: max. 180 mA
V2: max. 90 mA

Sensor Connection Specifications

Connector Type

M12 5-pin female A-code

V1 Power Supply Capacity

Ports 1 and 5: Each port max. 4 A, with short-circuit protection
Ports 2 to 4, 6 to 8: Each port max. 2 A, with short-circuit protection

V2 Power Supply Capacity

Ports 5 and 6: Each port max. 4 A, with short-circuit protection
Ports 7 and 8: Each port max. 2 A, with short-circuit protection

IO-Link Specifications

Number of Connectable Devices

8

Compliant Standards

Ver1.1

Transmission Speed

COM1: 4.8 kbps
COM2: 38.4 kbps
COM3: 230.4 kbps

Port type

Ports 1 to 4: Class A
Ports 5 to 8: Class B*1

Process Data Size

Input: Max. 32 bytes/Output: Max. 32 bytes

Digital Input (DI) Specifications

Number of Inputs

Max. 12 (when using DI mode)

Input Type

PNP

ON Voltage/ON Current

11 V or higher/2 mA or higher

OFF Voltage/OFF Current

Less than 5 V/less than 1.5 mA

Input Current

Pin 2: approx. 7 mA, Pin 4: approx. 12 mA

Digital Output (DO) Specifications

Number of Outputs

Max. 4

Output Type

PNP

Maximum Load Current

Each port max. 2 A

Short-Circuit Protection Circuit

Yes

Leakage Current

0.1 mA or lower

Residual Voltage

1 V or lower

Environmental resistance

Enclosure rating

IP65/IP67/IP69K

Ambient temperature

-40°C to +70°C -40°F to +158°F (no freezing)

Vibration resistance

5 to 150 Hz/20 G/10 sweeps each in X, Y, and Z axes

Shock resistance

15 G/11 ms/3 times each in X, Y, and Z axes

Case Material

Housing: PA6-GF30
IP address settings switch cover: PEI
Connector: SUS303

Weight

Approx. 530 g 18.69 oz

*1 When using Class B, V1 and V2 each require a power supply.

Keyence New Stock Image
Keyence SZ-04M Keyence
Sale price €2.258,95
Only 5 units left

Specifications

Model

SZ-04M

Type

Multi-function type

Detection
capability

Minimum detectable object size

Diameter 30 mm 1.18"/40 mm 1.58", 50 mm 1.97", 70 mm 2.76", 150 mm 5.91" (depends on the setting)
Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max.

Detectable angle

270° (-45° to 225°)

Response time
(ON to OFF)

General scan cycle (Scan cycle A)

60 ms (2 scans) to 480 ms (16 scans)

Specific scan cycle (Scan cycle B)

66 ms (2 scans) to 528 ms (16 scans)

Response time
(OFF to ON)

General scan cycle (Scan cycle A)

Response time of ON to OFF +125 ms

Specific scan cycle (Scan cycle B)

Max.
protection
zone

Minimum detectable object size: 70 mm 2.76"/150 mm 5.91"

4.2 m 13.78' (-5° to 185°), 2.8 m 9.19' (-45° to -5°, 185° to 225°)

Minimum detectable object size: 50 mm 1.97"

3.0 m 9.84' (-5° to 185°), 2.0 m 6.56' (-45° to -5°, 185° to 225°)

Minimum detectable object size: 40 mm 1.58"

2.4 m 7.87' (-5° to 185°), 1.6 m 5.25' (-45° to -5°, 185° to 225°)

Minimum detectable object size: 30 mm 1.18"

1.8 m 5.91' (-5° to 185°), 1.2 m 3.94' (-45° to -5°, 185° to 225°)

Max.
warning zone
(non safety
related)

Minimum detectable object size: 70 mm 2.76"/150 mm 5.91"

10.0 m 32.18' (-5° to 185°), 7.0 m 22.97' (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 50 mm 1.97"

7.5 m 24.61' (-5° to 185°), 5.0 m 16.4' (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 40 mm 1.58"

6.0 m 19.69' (-5° to 185°), 4.0 m 13.12' (-45° to -5°, 185° to 225°)*1

Minimum detectable object size: 30 mm 1.18"

4.5 m 14.76' (-5° to 185°), 3.0 m 9.84' (-45° to -5°, 185° to 225°)*1

Additional safety distance

100 mm 3.94"*2

Light source

Type, wavelength

Infrared laser diode, 905 nm

Laser class

Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10 *3)

OSSD output

Output

PNP or NPN (Selectable according to the connector cable)
4 outputs

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

OFF-state voltage

Max. 2.0 V (with a cable length of 5 m 16.4')

Leakage current

Max. 1 mA*5

Max. capacitive load

2.2 µF (with a load resistance of 100Ω)

Load wiring resistance

Max. 2.5Ω*6

Input
(safety-related)

Input resistance

4.4 kΩ (for Input 1, 3, 4, and 5)
2.2 kΩ (for Input 2 and 6)

Non
safety-related
output
(AUX output)

Output

PNP/NPN totem pole output
6 outputs

Max. load current

50 mA

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

Muting lamp
output

(AUX6 output can be assigned for the
muting lamp output)

Can be connected to the
incandescent lamp
(24 V DC, 1 to 5.5 W) and LED
lamp (load current 10 to 230 mA)

Cable length

30 m 98.43' or less *7

Approved
standards

EMC

EMS

IEC61496-1, EN61496-1, UL 61496-1

EMI

EN55011 Class A, FCC Part15B Class A

Safety

IEC61496-1, EN61496-1, UL 61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR)
IEC61508, EN61508, IEC62061, EN62061 (SIL2), EN ISO13849-1:2015 (PL d, Category 3) UL508, UL1998

Rating

Power voltage

When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less
When using a battery: 24 VDC +20 %/-30 %

Power consumption

Max. 9.5 W (without load)
Max. 50 W (with load)

Environmental resistance

Enclosure rating

IP65 (IEC60529)*8

Ambient light

Incandescent lamp: 1,500 lux or less*9

Operating ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Operating relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

35 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum die casting, SPHC (Bottom)

Window

Polycarbonate

Weight

Approx. 1.6 kg

*1 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
*2 If there is a high reflective background within 1.5 m 4.921' from the boundary of the protection zone, 200 mm 7.87" must be added as supplementary necessary distance to the protection zone in case of calculation of the minimum safety distance.
*3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*4 For the load current calculation of the OSSD output and the AUX output, make sure it is 1.5 A or less when using converter power supply (or 1.0 A or less when the cable length is 25 m 82.02' or more),
and 1.0 A or less when using a battery (or 0.5 A or less when the cable length is 5 m 16.40' or more)
*5 This also takes into account the situations when power is either off or disconnected.
*6 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operation. However, it must be 1.0 Ω or less if the load current is 300 mA or more.
*7 It must be 10 m 32.81' or less if the power is supplied by battery.
*8 When the setting cover is open, or the connector cable is not connected, the IP65 certification cannot be met. In addition, the SZ-16D doesn't fulfill the requirements of IP65 degree of protection with the connector cable for the RS-422A communication unattached..
*9 The SZ should not be installed so as to have light interference within ±5° to the detection plane.

keyence Stock Image
Keyence GS-71P5 Keyence
Sale price €265,95
Only 5 units left

Specifications

Model

GS-71P5

Lock type

Power-to-lock type

Type

Standard type

Response time

Lock

Lock→Unlock

320 ms*1*2

Unlock→Lock

220 ms*1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm ±0.08"

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz*4

Door radius

Min. 250 mm 9.84"

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

-

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

-

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

3.4 W*6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified),
Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55C° -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*7

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminum alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminum alloy, SUS303

Weight

Approx. 560 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm 0.12", Sar(OFF→ ON) = 10.5 mm 0.41".
*5 Do not apply excessive torque (0.45N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

Keyence Stock Image
Keyence FU-69X Keyence
Sale price €125,95
Only 7 units left

Specifications

Model

FU-69X*1

Size

M3

Fibre unit length

1 m39.37" cannot be cut

Minimum bend radius

R4 mm0.157" high-flex

Minimum detectable object

Gold wire with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 3 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

Keyence New Stock Image
Keyence GS-10PC Keyence
Sale price €306,95
Only 8 units left

Specifications

Model

GS-10PC

Type

Simple function type

Operating distance

Front

Sao(OFF→ON)

10 mm 0.39"

Sar(ON→OFF)

18 mm 0.71"

Side

Sao(OFF→ON)

6 mm 0.24"

Sar(ON→OFF)

14 mm 0.55"

Response time

Detection

Detect→Not detect

20 ms + 2 ms × (number of units cascaded -1)*1

Not detect→Detect

30 ms + 25 ms × (number of units cascaded -1)*1

Door operation

Acceptable operation frequency

3 Hz

Cascading

Standard

-

Using Y-shaped connector

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 150 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

OFF state voltage

Max 2.0 V (with a cable length of 5 m 16.40')

Leakage current

Max. 500 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max.2.5Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m 16.40')

External input (Short-circuit current)

Safety input

-

Reset/EDM input

Applicable Standards (Safety)

EN 61508, IEC 61508 (SIL3)
EN 6206, IEC62061 (SIL CL3)
EN ISO13849-1: 2015 (PLe, Category 4)
EN ISO14119 (Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Power consumption

0.8 W

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C -4°F to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25°C to +70°C -13°F to 158°F (No freezing)*2

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

Zinc die cast (Nickel chrome plating), PBT, PAR

Cable

PVC

Actuator

Case

SUS430, SUS304, PBT

Weight

Approx. 80 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.

Keyence New Stock Image
Keyence GS-ML51P Keyence
Sale price €399,95
Only 6 units left

Specifications

Model

GS-ML51P

Type

For sliding door M12 Connector Standard

Holding force when locked

500N

Holding force when unlocked

Approx. 30N *1

Cascading

Max. 20 units

Operating distance

Sao(OFF→ON)

0.1 mm 0.004" *2

Sar(ON → OFF)

15 mm 0.59" *2

Response time (ms)

Lock→Unlock

250 ms *3

Unlock→Lock

Detect→ Not detect

20 ms + 2 ms × (number of cascaded unit -1) *3

Not detect→ Detect

300 ms + 25 ms × (number of cascaded unit -1) *3

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

150 mA

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m 16.4')
Max. 3.5 V (with a cable length of 31 m 101.7')

OFF state voltage

Max. 2.0 V (with a cable length of 5 m 16.4')
Max. 3.0 V (with a cable length of 31 m 101.7')

Leakage current

Max. 0.5 mA

Max. capacitive load

0.8 μF

Load wiring resistance

Max. 2.5Ω

AUX (Non-safety related output)

Output

Transistor output
(Only advanced function type has two outputs.)

Max. load current

50 mA

Residual voltage (during ON)

Max. 2.5 V(with a cable of 5 m 16.4')
Max. 3.5 V(with a cable of 31 m 101.7')

External input (Short-circuit current)

Safety input

Approx. 1.5 mA × 2

Reset/EDM input

Approx. 5 mA
(For advanced function type only)

Lock control input

Approx. 2.5 mA

OSSD operation switching input

Approx. 2.5 mA
(For advanced function type only)

Applicable Standards (Safety)

EN61508, IEC61508(SIL3), EN ISO13849-1:2015(PL e, Category 4),
EN ISO14119(Type4), IEC60947-5-3, EN60947-5-3, UL 60947-5-2

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10% or less, Class2)

Power consumption

5 W

Environmental resistance

Enclosure rating

IP65/67 (IEC60529)

Operating ambient temperature

-20 to 55°C -4 to 131°F (No freezing)

Operating relative humidity

5% to 95%RH

Storage temperature

-25 to 70°C -13 to 158°F(No freezing) *4

Storage relative humidity

5% to 95%RH

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm 0.08",
5 minutes in each of the X, Y, and Z directions
(IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis
(IEC 60947-5-3)

Material

Main unit

PBT, PET/PAR, TPC, PC, Nickel-plated steel

Actuator

PBT, SUS304, Nickel-plated steel

Mounting bracket

Aluminum, Painted steel (screw: Steel)

Weight

Main unit

Approx.240 g
8.47 oz

Actuator

Approx.130 g 4.59 oz

*1 When the actuator is pulled first after unlocked, the holding force increases.
*2 Due to the flexible structure of the actuator, the guard can open 3.8 mm 0.15" larger than the "Sar". The clearance between the actuator and the main unit may be narrowed by a maximum of 2.3 mm 0.09" due to the magnet power built into the actuator.
*3 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of cascaded units -1).
*4 When stored for a long period of time, please store it at temperature of 55°C 131°F or lower.

Keyence New Stock Image
Keyence GC-S1R Keyence
Sale price €348,95
Only 7 units left

Specifications

Model

GC-S1R

Input/output points

Safety inputs

-

Safety outputs

Safety relay output

1 (3a)

AUX outputs

-

Test outputs

Safety input specifications

Input device

Input type

ON level (voltage/current)

OFF level (voltage/current)

Short-circuit current

Protection circuit

Maximum cable length

Safety output specifications

Output type

Maximum load current

Residual voltage (during ON)

Leakage current (during OFF)

Maximum capacitive load

Load wiring resistance

Protection circuit

Maximum cable length

Safety relay output specifications

Output type

Relay (3a) (Externally-protected outputs)*1

Rated load (resistance load)

250 VAC 6A / 30 VDC 6A*2

Rated load (inductive load)

240 VAC 2A (AC-15) / 24 VDC 1A (DC-13)

Relay output mechanical life

Resistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 times
Resistance load (250 VAC 1A/30 VDC 1 A): Min. 500,000 times
Inductive load (AC-15: 240 VAC 2 A): Min. 100,000 times (cosø = 0.3)
Inductive load (DC-13: 24 VDC 1 A): Min. 100,000 times (L/R = 48 ms)

Maximum cable length

Max. 100 m 328.1'

B10d

With rated load: 400,000
With low load: 2,000,000

Test output specifications

Output type

-

Maximum load current

Protection circuit

Maximum cable length

AUX output specifications

Output type

Maximum load current

Residual voltage (during ON)

Leakage current (during OFF)

Protection circuit

Maximum cable length

Applicable standards

EMC

EMS: IEC 61131-2/-6, EN61131-2/-6,EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A

Safety

IEC 61508, EN 61508 SIL3, IEC62061 SIL CL3, ISO/EN 13849-1:2015 Cat. 4, PL e, UL1998

Dimensions

39.6×95×90 mm 1.56"×3.74"×3.54" (W×D×H)

Power supply

Power voltage

-

Power consumption

Max. 80 mA

Environmental resistance

Ambient temperature

−10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

5 to 85% (No condensation)

Storage temperature

-25 to +70 °C -13 to 158 °F (No freezing)

Operating altitude

Max. 2000 m 6561.7'

Overvoltage category

II (III for relay output part)

Pollution degree

2

Vibration resistance

Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14"
Frequency: 9 to 150 Hz, Acceleration: 10 m/s2
10 times each in X, Y, Z directions

Shock resistance

Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions

Material

Polycarbonate

Weight

Approx. 180 g

*1 To comply with the requirements of IEC61131-2, connect 10 A fast blow fuse (IEC 60217) in series to each contact.
*2 Check the derating characteristics described later.

Keyence New Stock Image
Keyence VP-90 Keyence
Sale price €452,95
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence OP-87355 Keyence
Sale price €168,95
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence IV2-CP50 Keyence
Sale price €699,95
In stock, 19 units

Specifications

Model

IV2-CP50

Supported languages

English / Japanese / German / Chinese (Simplified) /Chinese (Traditional) / Korean /
Italian / French / Spanish / Portuguese / Czech / Hungarian / Polish / Thai*1

Display

5.7" TFT color LCD, 640 × 480 (VGA)

Backlight

Method

White LED

Duration

Approx. 50000 hours (25°C 77°F)

Touch panel

Method

Analog resistive

Actuating force

0.8 N or less

Indicators

PWR, SENSOR

Ethernet

Standard

100BASE-TX/10BASE-T*2

Connector

M12 4-pin connector*2

Expanded memory

USB memory*3

Rating

Power voltage

24 VDC ±10% (including ripple)

Current consumption

0.3 A or less

Environmental resistance

Enclosure rating

IP40

Ambient temperature

0 to +50°C 32 to 122°F (No freezing)

Relative humidity

35 to 85% RH (No condensation) *4

Drop resistance

1.3 m 4.3' onto concrete (2 times in an arbitrary direction)

Vibration resistance

10 to 55 Hz; double amplitude 0.7 mm 0.03"; 2 hours in each of the X, Y, and Z directions

Material

Main unit case: PC, Power connector: Brass + Ni plating, Ethernet connector: Zinc + Ni plating / PA,
USB connector cover: EDPM, Pen holder: PC, Adapter fixing hook: POM,
LED lamp cover: PC, Mounting adapter: PC, Stylus: POM

Weight

Main unit: Approx. 450 g
With wall mounting adapter and stylus attached: Approx. 485 g

*1 When connected to the IV2 Series. When connected to the IV Series, the supported languages are the same as the IV-M30.
*2 Dedicated for use in connecting to the IV2 Series and IV Series.
*3 Use only products recommended by KEYENCE.
*4 If the ambient operating temperature exceeds 40°C 104°F, use the product under conditions where the absolute humidity is 85% RH or less at 40°C 104°F.

Keyence Stock Image
Keyence FU-44TZ Keyence
Sale price €121,95
In stock, 11 units

Specifications

Model

FU-44TZ*1

Beam emitting direction

Top

Fibre unit length

1 m39.37" free-cut

Fibre unit diameter

ø1.0×2

Minimum bend radius

R2 mm0.079" Tough-Flex

Minimum detectable object

Gold wire with a diameter of 0.005 mm0.0002" *2

Environmental resistance

Ambient temperature

-40 to +50 °C -40 to 122 °F

Weight

Approx. 3 g

*1 For details on the detecting distance, see the fiber amplifier catalog.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

Keyence Stock Image
Keyence FU-10 Keyence
Sale price €140,95
Only 6 units left

Specifications

Model

FU-10

Type

Variable spot

Focal distance

10 to 30 mm0.394" to 1.181"

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.3×2

Environmental resistance

Ambient temperature

-40 to +70 °C -40 to 158 °F

Weight

Approx. 5 g

Keyence Stock Image
Keyence FD-G50 Keyence
Sale price €1.017,95
Only 6 units left

Specifications

Model

FD-G50

Pipe size

DN (Diameter Nominal)

32 A, 40 A, 50 A

NPS (Nominal Pipe Size)

1 1/4", 1 1/2", 2"

Outer diameter of pipe

ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44"

Pipe thickness

2.4 to 5.7 mm 0.09" to 0.22"

Supported pipe materials

Iron, steel, stainless steel

Supported fluids

Air, Nitrogen, other gases*1

Fluid temperature

0 to 60ºC 32 to 140 °F

Recommended pressure

0.4 MPa or greater (58 PSI or greater)

Rated velocity of flow range

Up to 15 m/s

Actual flow rate range (typical)

m3/h

Pipe size 32 A: 54.00
Pipe size 40 A: 72.00
Pipe size 50 A: 120.00

L/min

Pipe size 32 A: 900.0
Pipe size 40 A: 1200.0
Pipe size 50 A: 2000.0

CFM

Pipe size 32 A: 32.00
Pipe size 40 A: 42.00
Pipe size 50 A: 70.00

Standard flow rate range (typical) [CFM]

20°C 68°F 60 psi 0.41 MPa

Pipe size 32 A: 151.58
Pipe size 40 A: 198.95
Pipe size 50 A: 331.58

20°C 68°F 80 psi 0.55 MPa

Pipe size 32 A: 192.17
Pipe size 40 A: 252.22
Pipe size 50 A: 420.37

20°C 68°F 100 psi 0.69 MPa

Pipe size 32 A: 232.76
Pipe size 40 A: 305.49
Pipe size 50 A: 509.16

20°C 68°F 120 psi 0.83 MPa

Pipe size 32 A: 273.35
Pipe size 40 A: 358.77
Pipe size 50 A: 597.95

Display

QVGA 2.2" LCD color monitor

Display update cycle

Approx. 3 Hz

Display resolution

Instantaneous flow rate

0.01 m3/h, 0.1 L/min, 0.01 CFM

Consumption/leakage amount

0.01 m3, 1 L, 0.1 CF

Response time

1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)

Measurement accuracy

Between 10 and 100% of F.S.

±2.0% of RD*2*3*4*5

Between 1 and 10% of F.S.

±1.0% of F.S.*2*3*4*5

Zero point error

±0.15% of F.S.*2*6

Static leakage repeatability

±1.0% of RD*4*7

Hysteresis

Variable

Flow units

CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min

I/O wiring connection port

M12 4-pin connector (male)

Detection mode (switchable)

ch.1

Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8

ch.2

Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8

Standard I/O (switchable)

Control output (ch.1/ch.2)

NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less

Analog output (ch.2)

4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less

External input (ch.2)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output

Analog input (for volume conversion)

M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less

Power supplied to pressure sensor

Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)

Communication interface

USB

USB 2.0

Ethernet

Standard

IEEE 802.3u (100BASE-TX)

Transmission rate

100 Mbps

Cable

Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable

Connector

M12 connector (female, D-code)

Network function

Modbus TCP, EtherNet/IP™, IO-Link*9

Recording capacity

Consumption amount/ leakage amount

Approx. 5 years

Events

100

Power supply

Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2

Power consumption

350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),
550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)

Environmental resistance

Enclosure rating

IP65/67 (IEC 60529)*10

Ambient temperature

Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)

Relative humidity

5 to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes

Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material

Display unit

Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating

Detection head

Body: PPS/SUS304, rear surface: rubber

Mounting/damping bracket

SUS304

Weight

Approx. 2.7 kg

*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.
*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.
*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.
*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.
*5 The linearity error characteristic due to the pipe is not included in this value.
*6 It is possible to reduce zero point errors by performing an origin adjustment.
*7 This is the value within the range where measurement accuracy is guaranteed.
*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.
• ch.1: Pulse(+) mode
• ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input
*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 The IP65/67 enclosure rating is lost when a USB connection is established.