Specifications
Model |
SL-M64H |
|||
Detecting distance when using the SL-C Series |
When using SL-CH |
With 1 mirror: 8.1 m, with 2 mirrors: 7.2 m, with 3 mirrors: 6.5 m, with 4 mirrors: 5.9 m |
||
When using SL-CL | ||||
When using SL-CF |
With 1 mirror: 6.3 m, with 2 mirrors: 5.6 m, with 3 mirrors: 5.1 m, with 4 mirrors: 4.6 m |
|||
Reflective surface length |
1318 mm 51.89" |
|||
Supported: SL-C Series |
SL-C Series units that have a total length shorter than that of the reflective surface |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Material |
Main unit case |
Aluminum |
||
Mirror |
Back-side mirror |
|||
Mounting bracket |
SUS304 |
|||
Accessories |
Mounting bracket (3-piece set) |
|||
Weight |
Approx. 4.3 kg (including mounting bracket) |
|||

Specifications
Model |
SL-M80H |
|||
Type |
Corner Mirror |
|||
Overview |
This mirror reflects the light beam from the transmitter to an angle between 45° and 95°. Up to 4 mirrors can be used. |
|||
Applicable product |
GL-R72H, GL-R80H |
|||
Number included |
Mirror: 1, bracket: 8, hexagon socket bolt (M6, width across flat: 5 mm): 24, angle nut (M6): 8 |
|||
Material |
Mirror: back-side mirror, case: aluminum, bracket: SUS304, hexagon socket bolt (M6, width across flat: 5 mm): SUS304, angle nut (M6): SUS304 |
|||
Note |
For each single corner mirror, the detection distance will decrease by 10%. |
|||
Weight |
Approx. 5.4 kg (including mounting brackets) |
|||

Specifications
Model |
SL-M96H |
|||
Type |
Corner Mirror |
|||
Overview |
This mirror reflects the light beam from the transmitter to an angle between 45° and 95°. Up to 4 mirrors can be used. |
|||
Applicable product |
GL-R88H, GL-R96H |
|||
Number included |
Mirror: 1, bracket: 8, hexagon socket bolt (M6, width across flat: 5 mm): 24, angle nut (M6): 8 |
|||
Material |
Mirror: back-side mirror, case: aluminum, bracket: SUS304, hexagon socket bolt (M6, width across flat: 5 mm): SUS304, angle nut (M6): SUS304 |
|||
Note |
For each single corner mirror, the detection distance will decrease by 10%. |
|||
Weight |
Approx. 6.2 kg (including mounting brackets) |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.




PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.



Specifications
Model |
SL-T11R |
|||
Combined light curtain |
SL-V Series |
|||
Output |
FSD1、2 |
230 VAC/4 A, 30 VDC/2 A (Resistance load) |
||
Life-span |
Mechanical life: 10 million cycles or more/Electrical life: 0.1 million cycle or more*1 |
|||
Response time (ms) |
ON→OFF |
+6 ms |
||
OFF→ON |
+15 ms |
|||
Approved standards |
EMC |
EMS |
UL61496-1, IEC61496-1, EN61496-1 |
|
EMI |
FCC Part15B Class A, ICES-003 Class A, EN55011 Class A |
|||
Safety |
UL61496-1, IEC61496-1, EN61496-1 (Type 4 ESPE), ISO 13849-1: 2015 (Cat 4 PLe), UL508, EN50178 |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
100 mA or less (at 24 VDC, SL-T11R alone) |
|||
Environmental resistance |
Enclosure rating |
IP20 (IEC60529), Set inside control panel with IP54 or more |
||
Pollution degree |
2 |
|||
Overvoltage category |
III |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 330 g |
|||
*1 For the specifications for the outputs other than FSD and for each input, refer to the SL-V Instruction Manual. | ||||

Specifications
Model |
SL-U2 |
|||
System |
Switching type |
|||
Input power supply voltage |
100 to 240 VAC ±10 % (50/60 Hz) |
|||
Ripple/noise |
240 mV p-p or less |
|||
Output capacity |
1.8 A |
|||
Supply voltage interruption |
10 ms max. |
|||
Approved standards |
EMC |
EMI |
EN61000-6-2, EN55011 Class A, FCC Part15 Class A |
|
Safety |
EN62368-1, EN62477-1, UL 60950-1, CSA 60950-1 |
|||
Rating |
Power voltage |
24 VDC ±10 %, Class 2 |
||
Power consumption |
135 VA |
|||
Environmental resistance |
Pollution degree |
2 |
||
Overvoltage category |
II |
|||
Insulation resistance |
At least 50 MΩ (500 VDC mega, between all external terminals and case) |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,500 VAC, 1 min. (between all external terminals and case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 240 g |
|||


Specifications
Model |
SL-V08H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Beam axis spacing/Lens diameter |
20 mm/ø5 mm 0.79"/ø0.20" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 9 m |
|||
Response time (ms) |
ON→OFF |
7*1 |
||
OFF→ON |
47*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
56*6 |
|
Receiver |
70*6 |
|||
When the center indicator is OFF |
Transmitter |
52*6 |
||
Receiver |
65*6 |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
150 g |
||
Receiver |
155 g |
|||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||


Specifications
Model |
SL-V103F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Beam axis spacing/Lens diameter |
10 mm/ø4 mm 0.39"/ø0.16" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 7 m |
|||
Response time (ms) |
ON→OFF |
20.1*1 |
||
OFF→ON |
60.1*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
159*6 |
|
Receiver |
101*6 |
|||
When the center indicator is OFF |
Transmitter |
149*6 |
||
Receiver |
90*6 |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
760 g |
||
Receiver |
775 g |
|||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SL-V103FM |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Beam axis spacing/Lens diameter |
10 mm/ø4 mm 0.39"/ø0.16" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 7 m |
|||
Response time (ms) |
ON→OFF |
20.1*1 |
||
OFF→ON |
60.1*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
159*6 |
|
Receiver |
101*6 |
|||
When the center indicator is OFF |
Transmitter |
149*6 |
||
Receiver |
90*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
2,190 g |
||
Receiver |
2,200 g |
|||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||

Specifications
Model |
SL-V104H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Beam axis spacing/Lens diameter |
20 mm/ø5 mm 0.79"/ø0.20" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 7 m |
|||
Response time (ms) |
ON→OFF |
20.2*1 |
||
OFF→ON |
60.2*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
159*6 |
|
Receiver |
107*6 |
|||
When the center indicator is OFF |
Transmitter |
143*6 |
||
Receiver |
84*6 |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1,360 g |
||
Receiver |
1,405 g |
|||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||

Specifications
Model |
SL-V111F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Beam axis spacing/Lens diameter |
10 mm/ø4 mm 0.39"/ø0.16" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 7 m |
|||
Response time (ms) |
ON→OFF |
21.2*1 |
||
OFF→ON |
61.2*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
163*6 |
|
Receiver |
104*6 |
|||
When the center indicator is OFF |
Transmitter |
152*6 |
||
Receiver |
92*6 |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
810 g |
||
Receiver |
815 g |
|||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||

Specifications
Model |
SL-V111FM |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Beam axis spacing/Lens diameter |
10 mm/ø4 mm 0.39"/ø0.16" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 7 m |
|||
Response time (ms) |
ON→OFF |
21.2*1 |
||
OFF→ON |
61.2*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
163*6 |
|
Receiver |
104*6 |
|||
When the center indicator is OFF |
Transmitter |
152*6 |
||
Receiver |
92*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
2,330 g |
||
Receiver | ||||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||

Specifications
Model |
SL-V112H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Beam axis spacing/Lens diameter |
20 mm/ø5 mm 0.79"/ø0.20" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 7 m |
|||
Response time (ms) |
ON→OFF |
21.3*1 |
||
OFF→ON |
61.3*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
162*6 |
|
Receiver |
109*6 |
|||
When the center indicator is OFF |
Transmitter |
146*6 |
||
Receiver |
86*6 |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1,460 g |
||
Receiver |
1,505 g |
|||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||

Specifications
Model |
SL-V119F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Beam axis spacing/Lens diameter |
10 mm/ø4 mm 0.39"/ø0.16" |
|||
Effective aperture angle |
Max. ±2.5 ° (When operating distance is 3 m 98.23' or more) |
|||
Working distance |
0.1 to 7 m |
|||
Response time (ms) |
ON→OFF |
22.3*1 |
||
OFF→ON |
62.3*1 |
|||
Light source |
Infrared LED (850 nm) |
|||
Operation mode |
Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) |
|||
OSSD output |
Output |
2 outputs each for PNP and NPN. Can be changed by using the connector cable. |
||
Max. l oad current |
500 mA*2 |
|||
Residual vol tage (during ON) |
Max. 2.5 V (with a cable length of 7 m 22.97') |
|||
Leakage current |
Max. 100 µA*3 |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring resistance |
Max. 2.5 Ω*4 |
|||
Non safety-rel ated output |
AUX |
Output with automatic PNP/NPN switching function, 50 mA max. |
||
Interlock-reset-ready output | ||||
Alarm output | ||||
Clear/blocked output | ||||
State information output 1, 2 | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected |
|||
Input |
EDM input |
Short-circuit current 10 mA |
||
Wait input |
Short-circuit current 2.5 mA |
|||
Reset input | ||||
Muting input 1, 2 | ||||
Override input | ||||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Rating |
Power voltage |
24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less |
||
Current consumption (mA) |
When the center indicator is ON |
Transmitter |
166*6 |
|
Receiver |
106*6 |
|||
When the center indicator is OFF |
Transmitter |
156*6 |
||
Receiver |
93*6 |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Zinc die-cast |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
850 g |
||
Receiver |
855 g |
|||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of the response times of al l the individual SL-V units, but the response time (OFF to ON) is the same as that of a singl e SL-V unit. | ||||