
Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
1
3
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NC 6 A
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(400 V) Three Phase, NC 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NC 17.25 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NC 17.25 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NC 2.7 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NC 3 Hp
(440 ... 480 V AC) Single Phase, NC 0.5 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NC 2 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NC 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NC 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524202
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538605
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707579

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.225 kg
Technical
2
0
0
0
2P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NO 1.3 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.23 kg
4013614524219
48 piece
280 mm
395 mm
210 mm
11.5 kg
4013614538612
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190264

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
2
2
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524226
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538629
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707575
4190260
3210565

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.23 kg
Technical
3
0
0
0
3P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.23 kg
4013614524233
48 piece
280 mm
395 mm
210 mm
11.5 kg
4013614538636
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
3
1
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524240
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538643
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707577
4190268
3210567

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
4
0
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524257
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538650
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707571
4190249
3210561

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
2
2
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
400 ... 415 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524295
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538698
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190261

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
3
1
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
400 ... 415 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524318
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538711
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190269

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
4
0
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
400 ... 415 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524325
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538728
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190250

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.245 kg
Technical
2
2
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
12 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.245 kg
4013614524363
48 piece
280 mm
395 mm
210 mm
12.3 kg
4013614538766
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190262

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.245 kg
Technical
3
1
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
12 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.245 kg
4013614524394
48 piece
280 mm
395 mm
210 mm
12.3 kg
4013614538780
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190270

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.245 kg
Technical
4
0
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
12 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.245 kg
4013614524400
48 piece
280 mm
395 mm
210 mm
12.3 kg
4013614538797
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190251

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.25 kg
Technical
4
0
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
4 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.25 kg
4013614524431
48 piece
280 mm
395 mm
210 mm
12.5 kg
4013614538827
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707805

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
3
0
0
0
3P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
4 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524530
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538926
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707809
4190245

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.24 kg
Technical
3
1
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
4 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.24 kg
4013614524547
48 piece
280 mm
395 mm
210 mm
12 kg
4013614538933
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707808

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.24 kg
Technical
4
0
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
4 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 ... 240 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.24 kg
4013614524554
48 piece
280 mm
395 mm
210 mm
12 kg
4013614538940
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707806
4190244

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.37 kg
Technical
2
0
0
0
2P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 40 A
(230 V) Single Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.37 kg
4013614524592
32 piece
280 mm
395 mm
210 mm
12.2 kg
4013614538988
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707588

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.405 kg
Technical
2
2
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 30 A
(NO) 40 A
(NC) 30 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.405 kg
4013614524608
32 piece
280 mm
395 mm
210 mm
12.96 kg
4013614538995
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707582

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.385 kg
Technical
3
0
0
0
3P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.385 kg
4013614524615
32 piece
280 mm
395 mm
210 mm
12.32 kg
4013614539008
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707586

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.405 kg
Technical
3
1
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 30 A
(NO) 40 A
(NC) 30 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.405 kg
4013614524622
32 piece
280 mm
395 mm
210 mm
12.96 kg
4013614539015
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707584

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.405 kg
Technical
4
0
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.405 kg
4013614524639
32 piece
280 mm
395 mm
210 mm
12.96 kg
4013614539022
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707580
4190276
3210570

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.37 kg
Technical
2
0
0
0
2P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 40 A
(230 V) Single Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.37 kg
4013614524783
32 piece
280 mm
395 mm
210 mm
12.2 kg
4013614539176
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707589

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.405 kg
Technical
2
2
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 30 A
(NO) 40 A
(NC) 30 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.405 kg
4013614524790
32 piece
280 mm
395 mm
210 mm
12.96 kg
4013614539183
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707583

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.405 kg
Technical
3
1
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 30 A
(NO) 40 A
(NC) 30 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NO 22 A
(400 V) Three Phase, NO 22 A
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(400 V) Three Phase, NO 27.7 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
(230 V) Single Phase, NO 3.7 kW
(400 V) Three Phase, NO 11 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(220 ... 240 V AC) Three Phase, NO 7.5 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(440 ... 480 V AC) Three Phase, NO 15 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(220 ... 240 V AC) Three Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
(440 ... 480 V AC) Three Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.405 kg
4013614524813
32 piece
280 mm
395 mm
210 mm
12.96 kg
4013614539206
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707585
