Filters

Sensors

1788 products

Showing 1753 - 1776 of 1788 products

Showing 1753 - 1776 of 1788 products
View
keyence Stock Image
Keyence OP-88543 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88543

Type

Connector Set for Sensor Head Connection

Appearance

Pack of 2

Weight

Approx. 2 g

keyence Stock Image
Keyence OP-88542 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88542

Appearance

Amplifier Holder for Standard Models (Includes M3 Screws × 2)

Material

SUS304 Other

Weight

Approx. 32 g

keyence Stock Image
Keyence OP-88504 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88504

Appearance

Pitch-Conversion Mounting Bracket (Includes Sensor Head Fastening Screws × 2)

Material

SUS316L Other

Weight

Approx. 9 g

keyence Stock Image
Keyence OP-88503 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88503

Appearance

Adjustable Bracket Locking Post (65 mm 2.56")

Material

SUS316L Other

Weight

Approx. 21 g

keyence Stock Image
Keyence OP-88502 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88502

Appearance

Adjustable Bracket B (Includes Sensor Head Fastening Screw × 2)

Material

SUS316L Other

Weight

Approx. 20 g

keyence Stock Image
Keyence OP-88501 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88501

Appearance

Adjustable Bracket A (Includes Sensor Head Fastening Screw × 2)

Material

SUS316L Other

Weight

Approx. 15 g

keyence Stock Image
Keyence OP-88500 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88500

Appearance

Rear Mounting Bracket (Includes Sensor Head Fastening Screws × 2)

Material

SUS316L Other

Weight

Approx. 17 g

keyence Stock Image
Keyence OP-88499 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88499

Appearance

L-Type Mounting Bracket (Includes Sensor Head Fastening Screws × 2)

Material

SUS316L Other

Weight

Approx. 9 g

keyence Stock Image
Keyence OP-88296 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88296

Type

Loose wires/M12 adapter

Applicable product

FD-XA1/XA5 cables, or cables with cross sectional area 0.14 to 0.34 mm2
and outer diameter ø 3.5 to 6 mm 0.14 " to 0.24 "

Frequency of connections between conductors of the same cross section

10

Insertion/withdrawal cycles

More than 100 times

Wire diameter including insulation

ø 0.7 to 1.6 mm 0.028 " to 0.06 "

enclosure rating

IP65/67

Ambient temperature

-25 °C to +80 °C -13 to 176 °F

Note

A connector that converts loose wires to a M12 4-pin connector. Useful for connecting to IO-Link compatible master units.

Weight

Approx. 12 g 0.42 oz

Keyence Stock Image
Keyence OP-88245 Keyence
Sale price €99,95
Only 7 units left

Specifications

Model

OP-88245

Type

Amplifier securing bracket (for main unit)

Overview

It can be mounted without the DIN rail.

keyence Stock Image
Keyence LR-XB1 Keyence
Sale price€0,00
Sold Out

Specifications

Model

LR-XB1

Appearance

Fine-Tuning Mounting Bracket (Includes Sensor Head Fastening Screws × 2 Mounting Bracket Locking Screws × 2/Plate Nut × 1)

Material

Zinc Nickel Plating SUS304 PPS Other

Weight

Approx. 30 g

keyence Stock Image
Keyence OP-88716 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88715 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88714 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88507 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88507

Type

High-flex

Sensor Side

M8 4-Pin Straight

Cable Connector

Loose wires

Length

10 m 32.8'

Material

Cable: PVC, Connector: Nickel-plated brass

Weight

Approx. 370 g

keyence Stock Image
Keyence OP-88506 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-88506

Type

High-flex

Sensor Side

M8 4-Pin Straight

Cable Connector

Loose wires

Length

5 m 16.4'

Material

Cable: PVC, Connector: Nickel-plated brass

Weight

Approx. 190 g

keyence Stock Image
Keyence OP-88505 Keyence
Sale price €556,95
Only 2 units left

Specifications

Model

OP-88505

Type

High-flex

Sensor Side

M8 4-Pin Straight

Cable Connector

Loose wires

Length

2 m 6.6'

Material

Cable: PVC, Connector: Nickel-plated brass

Weight

Approx. 80 g

Keyence Stock Image
Keyence OP-26751 Keyence
Sale price €102,95
Only 9 units left

Specifications

Model

OP-26751

Type

End unit

Overview

Used to secure the amplifier when main and expansion units are additionally set.

Applicable product

Expansion type sensor amplifier including FS-N10 Series.

Number included

2 pcs.

Material

Polycarbonate, stainless steel, Screw: Steel (Nickel plated)

Note

When adding sensor amplifier, use DIN rail and surely use end unit at both ends.

Keyence New Stock Image
Keyence LR-XH50 Keyence
Sale price €407,95
Only 10 units left

Specifications

Model

LR-XH50

Type

Cable Length: 2 m 6.6'

Detecting Distance

25.0 to 50.0 mm 0.98" to 1.97"

Standard Detectable Deviation

0.5 mm 0.02"

Display Resolution

0.1 mm 0.004"

Spot Size

Approx. 0.2 mm × 1.5 mm 0.008" × 0.06"
(at a detecting distance of 50 mm 1.97")

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 16,000 lux or less, Sunlight: 16000 lux or less

Ambient temperature

-10°C to +50°C 14°F to 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G); 6 times each for X, Y, and Z axes

Material

Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)

Accessories

Laser warning label

Weight

approx. 75 g

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.

Keyence New Stock Image
Keyence LR-XH250 Keyence
Sale price €424,95
In stock, 12 units

Specifications

Model

LR-XH250

Type

Cable Length: 2 m 6.6'

Detecting Distance

30 to 250 mm 1.18" to 9.84"

Standard Detectable Deviation

30 to 180 mm: 9 mm, 180 to 250 mm: 18 mm
1.18" to 7.09": 0.35", 7.09" to 9.84": 0.71

Display Resolution

1 to 2 mm 0.04" to 0.08"

Spot Size

Approx. 0.8 mm × 1.2 mm 0.03" × 0.05"
(at a detecting distance of 250 mm 9.84")

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 8000 lux or less, Sunlight: 8000 lux or less

Ambient temperature

-10°C to +50°C 14°F to 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G); 6 times each for X, Y, and Z axes

Material

Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)

Accessories

Laser warning label

Weight

approx. 75 g

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.

Keyence Stock Image
Keyence LR-XH100(10M) Keyence
Sale price€0,00
Sold Out

Specifications

Model

LR-XH100(10M)

Type

Cable Length: 10 m 32.8'

Detecting Distance

25.0 to 100.0 mm 0.98" to 3.94"

Standard Detectable Deviation

1.0 mm 0.04"

Display Resolution

0.1 mm 0.004"

Spot Size

Approx. 0.3 mm × 2 mm 0.012" × 0.08"
(at a detecting distance of 100 mm 3.94")

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 16,000 lux or less, Sunlight: 16000 lux or less

Ambient temperature

-10°C to +50°C 14°F to 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G); 6 times each for X, Y, and Z axes

Material

Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)

Accessories

Laser warning label, sensor head connector

Weight

approx. 250 g

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.

Keyence New Stock Image
Keyence LR-XH100 Keyence
Sale price €348,95
Only 10 units left

Specifications

Model

LR-XH100

Type

Cable Length: 2 m 6.6'

Detecting Distance

25.0 to 100.0 mm 0.98" to 3.94"

Standard Detectable Deviation

1.0 mm 0.04"

Display Resolution

0.1 mm 0.004"

Spot Size

Approx. 0.3 mm × 2 mm 0.012" × 0.08"
(at a detecting distance of 100 mm 3.94")

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 16,000 lux or less, Sunlight: 16000 lux or less

Ambient temperature

-10°C to +50°C 14°F to 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G); 6 times each for X, Y, and Z axes

Material

Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)

Accessories

Laser warning label

Weight

approx. 75 g

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.

Keyence New Stock Image
Keyence LR-XN11C Keyence
Sale price €348,95
In stock, 17 units

Specifications

Model

LR-XN11C

Type

NPN Output/PNP Output (Selectable output)

Cable/Connector

M8 connector*1

Main Unit/Expansion Unit

Main Unit (expansion not possible)

No. of Control Outputs

2*2

No. of External Inputs

1*2

Response Time

500 µs*3/1 ms/3 ms/10 ms/200 ms Selectable

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

Open collector, 30 VDC or lower, N.O./N.C.
100 mA or lower for 1 output; 100 mA or lower in total for 2 outputs
Residual voltage NPN: 1.4 V or lower (output current: 10 mA or lower)/2 V or lower (output current: 10 to 100 mA), PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA)

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable
Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower
Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)

Unit Expansion

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

Power supply

Power voltage

16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current)

Environmental resistance

Ambient temperature

−20 to +55°C -4°F to 131°F (no freezing)*5

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 (50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

Accessories

Instruction manual

Weight

Approx. 22 g

*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.
*2 Output 2 and the external input are selectable.
*3 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*4 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*5 Expansion by 1 or 2 units: −20 to +55°C -4°F to 131°F; Expansion by 3 to 10 units: -20 to +50°C -4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C -4°F to 113°F

Keyence Stock Image
Keyence LR-XN10 Keyence
Sale price €226,95
Only 9 units left

Specifications

Model

LR-XN10

Type

Cable/Connector

Main Unit/Expansion Unit

Expansion Unit

No. of Control Outputs

None*1

No. of External Inputs

Response Time

500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable

IO-Link

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

External Input

Unit Expansion

Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series.

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

OFF/4 units/8 units selectable*3

Power supply

Power voltage

16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V)

Environmental resistance

Ambient temperature

−20 to +55°C -4°F to 131°F (no freezing)*5

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 (50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

Accessories

Instruction manual

Weight

Approx. 21 g

*1 This counts as 1 output when expanding with multiple units to the FS-MC8N/MC8P and NU Series.
*2 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*3 Selecting four or eight interference prevention units causes the response time to change as follows: 4 Units selected: 6 ms/18 ms/60 ms/1.2 s selectable; 8 Units selected: 12 ms/36 ms/120 ms/2.4 s selectable.
*4 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*5 Expansion by 1 or 2 units: −20 to +55°C -4°F to 131°F; Expansion by 3 to 10 units: -20 to +50°C -4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C -4°F to 113°F

Recently viewed