Schneider_New_Products

5001 products

Showing 4321 - 4344 of 5001 products

Showing 4321 - 4344 of 5001 products
View
Schneider New Stock Image
Schneider LC1FF43 Schneider
Sale price €466,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F800FW Schneider
Sale price€0,00
Sold Out

TeSys F contactor, 3 poles (3NO), 800A/1000V AC-3, for motor applications up to 450kW@400V. It provides a low sealed consumption 110/120V DC coil, bolt terminals for bars or cables with lugs. For high operating rates until 600 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Resistive load
Motor control
Utilisation category AC-3
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Uc] control circuit voltage 110...125 V DC
100...120 V AC 40...400 Hz
[Ie] rated operational current 1000 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
800 A (at <131 °F (55 °C)) at <= 440 V AC AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 1000 A (at 104 °F (40 °C))
Rated breaking capacity 6400 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 5500 A 104 °F (40 °C) - 10 s
4600 A 104 °F (40 °C) - 30 s
3600 A 104 °F (40 °C) - 1 min
2600 A 104 °F (40 °C) - 3 min
1700 A 104 °F (40 °C) - 10 min
Associated fuse rating 1000 A gG at <= 440 V
800 A aM at <= 440 V
Average impedance 0.12 mOhm - Ith 1000 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 120 W AC-1
77 W AC-3
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 450 kW at 1000 V AC 50/60 Hz (AC-3)
450 kW at 500 V AC 50/60 Hz (AC-3)
475 kW at 660...690 V AC 50/60 Hz (AC-3)
110 kW at 400 V AC 50/60 Hz (AC-4)
450 kW at 380...400 V AC 50/60 Hz (AC-3)
450 kW at 415 V AC 50/60 Hz (AC-3)
450 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 220...230 V AC 50/60 Hz (AC-3)
Control circuit voltage limits Operational 0.85...1.1 Uc 131 °F (55 °C))
Drop-out 0.3...0.5 Uc 131 °F (55 °C))
Mechanical durability 5 Mcycles
Inrush power in W 1900 W 68 °F (20 °C))
Hold-in power consumption in W 12 W 68 °F (20 °C)
Maximum operating rate 600 cyc/h 131 °F (55 °C)
Operating time 40...50 ms opening
60...80 ms closing
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 60 x 5 mm
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 513.3 lbf.in (58 N.m)
Mounting Support Plate
Heat dissipation 12 W
motor power range 250…500 kW 200…240 V 3 phase
250…500 kW 380…440 V 3 phase
110…220 kW 200…240 V 3 phase
250…500 kW 480…500 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 110 V DC standard
125 V DC standard
110 V AC standard
115 V AC standard
120 V AC standard
Standards EN 60947-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-1
JIS C8201-4-1
Product Certifications ABS
RMRoS
CCC
UL
CB
CSA
UKCA
Compatibility code LC1F
Control circuit type DC standard
AC 40...400 Hz
Schneider New Stock Image
Schneider LC1F630U7 Schneider
Sale price €5.416,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F780F7 Schneider
Sale price €3.755,95
Only 3 units left

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-1
AC-3
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Uc] control circuit voltage 110 V AC 40...400 Hz
[Ie] rated operational current 1600 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
780 A (at <131 °F (55 °C)) at <= 440 V AC AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 1600 A (at 104 °F (40 °C))
Rated breaking capacity 6240 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 3000 A 104 °F (40 °C) - 3 min
6250 A 104 °F (40 °C) - 10 s
5600 A 104 °F (40 °C) - 30 s
4600 A 104 °F (40 °C) - 1 min
2200 A 104 °F (40 °C) - 10 min
Associated fuse rating 1600 A gG at <= 440 V
800 A aM at <= 440 V
Average impedance 0.1 mOhm - Ith 1600 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 250 W AC-1
60 W AC-3
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 450 kW at 1000 V AC 50/60 Hz (AC-3)
400 kW at 380...400 V AC 50/60 Hz (AC-3)
425 kW at 415 V AC 50/60 Hz (AC-3)
425 kW at 440 V AC 50/60 Hz (AC-3)
450 kW at 500 V AC 50/60 Hz (AC-3)
475 kW at 660...690 V AC 50/60 Hz (AC-3)
220 kW at 220...230 V AC 50/60 Hz (AC-3)
110 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))
Drop-out 0.2...0.4 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability 5 Mcycles
Inrush power in VA 2100 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA 50 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate 600 cyc/h 131 °F (55 °C)
Operating time 40...80 ms closing
130...230 ms opening
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 100 x 5 mm
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 513.3 lbf.in (58 N.m)
Mounting Support Plate
Heat dissipation 44 W
motor power range 250…500 kW 380…440 V 3 phase
110…220 kW 200…240 V 3 phase
250…500 kW 480…500 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 110 V AC standard
120 V AC standard
Standards EN 60947-1
JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
Product Certifications UL
RINA
ABS
CB
RMRoS
CSA
LROS (Lloyds register of shipping)
DNV
BV
UKCA
Compatibility code LC1F
Control circuit type AC 40...400 Hz
Schneider New Stock Image
Schneider LC1F630N7 Schneider
Sale price €4.987,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F630G7 Schneider
Sale price €1.533,95
Only 1 unit left

TeSys F contactor, 3 poles (3NO), 630A/1000V AC-3, for motor applications up to 250kW@400V. It provides a low sealed consumption 120/127V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 1200 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Motor control
Resistive load
Utilisation category AC-1
AC-4
AC-3
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Uc] control circuit voltage 120 V AC 40...400 Hz
[Ie] rated operational current 1000 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
630 A (at <131 °F (55 °C)) at <= 440 V AC AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 1000 A (at 104 °F (40 °C))
1250 A
Rated breaking capacity 5040 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 5050 A 104 °F (40 °C) - 10 s
4400 A 104 °F (40 °C) - 30 s
3400 A 104 °F (40 °C) - 1 min
2200 A 104 °F (40 °C) - 3 min
1600 A 104 °F (40 °C) - 10 min
Associated fuse rating 1000 A gG at <= 440 V
630 A aM at <= 440 V
Average impedance 0.12 mOhm - Ith 1000 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 120 W AC-1
48 W AC-3
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 335 kW at 380...400 V AC 50/60 Hz (AC-3)
375 kW at 415 V AC 50/60 Hz (AC-3)
400 kW at 440 V AC 50/60 Hz (AC-3)
400 kW at 500 V AC 50/60 Hz (AC-3)
450 kW at 660...690 V AC 50/60 Hz (AC-3)
450 kW at 1000 V AC 50/60 Hz (AC-3)
200 kW at 220...230 V AC 50/60 Hz (AC-3)
100 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))
Drop-out 0.25...0.5 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability 5 Mcycles
Inrush power in VA 1650 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA 22 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate 1200 cyc/h 131 °F (55 °C)
Operating time 40...80 ms closing
100...200 ms opening
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 60 x 5 mm
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 513.3 lbf.in (58 N.m)
Mounting Support Plate
Heat dissipation 20 W
Standards JIS C8201-4-1
IEC 60947-4-1
IEC 60947-1
EN 60947-4-1
EN 60947-1
Product Certifications LROS (Lloyds register of shipping)
RINA
CCC
BV
ABS
UL
DNV
CB
RMRoS
UKCA
Compatibility code LC1F
Control circuit type AC 40...400 Hz
Schneider New Stock Image
Schneider LC1F500U7 Schneider
Sale price €4.331,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F500G7 Schneider
Sale price €3.126,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F400S011 Schneider
Sale price €451,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F500FD Schneider
Sale price €1.711,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F400G7 Schneider
Sale price €1.682,95
Only 2 units left

TeSys F contactor, 3 poles (3NO), 400A/1000V AC-3, for motor applications up to 200kW@400V. It provides a low sealed consumption 120/127V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Motor control
Resistive load
Utilisation category AC-4
AC-3
AC-1
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Uc] control circuit voltage 120 V AC 40...400 Hz
[Ie] rated operational current 500 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
400 A (at <131 °F (55 °C)) at <= 440 V AC AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 500 A (at 104 °F (40 °C))
Rated breaking capacity 3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 3600 A 104 °F (40 °C) - 10 s
2400 A 104 °F (40 °C) - 30 s
1700 A 104 °F (40 °C) - 1 min
1200 A 104 °F (40 °C) - 3 min
1000 A 104 °F (40 °C) - 10 min
Associated fuse rating 400 A aM at <= 440 V
500 A gG at <= 440 V
Average impedance 0.26 mOhm - Ith 500 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 65 W AC-1
42 W AC-3
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 75 kW at 400 V AC 50/60 Hz (AC-4)
200 kW at 380...400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
257 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660...690 V AC 50/60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
110 kW at 220...230 V AC 50/60 Hz (AC-3)
Control circuit voltage limits Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))
Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability 10 Mcycles
Inrush power in VA 1075 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA 15 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate 2400 cyc/h 131 °F (55 °C)
Operating time 40...65 ms closing
100...170 ms opening
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 30 x 5 mm
Power circuit lugs-ring terminals 2 0.2 in² (150 mm²)
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 309.8 lbf.in (35 N.m)
Mounting Support Plate
Heat dissipation 14 W
motor power range 110…220 kW 480…500 V 3 phase
110…220 kW 380…440 V 3 phase
110…220 kW 200…240 V 3 phase
250…500 kW 480…500 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 120 V AC standard
Standards JIS C8201-4-1
EN 60947-1
IEC 60947-1
EN 60947-4-1
IEC 60947-4-1
Product Certifications ABS
DNV
RMRoS
LROS (Lloyds register of shipping)
UL
BV
CB
CSA
RINA
UKCA
Compatibility code LC1F
Control circuit type AC 40...400 Hz
Schneider New Stock Image
Schneider LC1F265U7 Schneider
Sale price €1.404,95
Only 1 unit left

TeSys F contactor, 3 poles (3NO), 265A/1000V AC-3, for motor applications up to 132kW@400V. It provides a low sealed consumption 240V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Resistive load
Motor control
Utilisation category AC-3
AC-1
AC-4
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC-1
<= 690 V AC-3
<= 690 V AC-4
<= 460 V DC
[Uc] control circuit voltage 240 V AC 40...400 Hz
[Ie] rated operational current 350 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
265 A (at <131 °F (55 °C)) at <= 440 V AC AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 350 A (at 104 °F (40 °C))
Rated breaking capacity 2120 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 2200 A 104 °F (40 °C) - 10 s
1230 A 104 °F (40 °C) - 30 s
950 A 104 °F (40 °C) - 1 min
620 A 104 °F (40 °C) - 3 min
480 A 104 °F (40 °C) - 10 min
Associated fuse rating 315 A aM at <= 440 V
400 A gG at <= 440 V
Average impedance 0.3 mOhm - Ith 350 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 37 W AC-1
21 W AC-3
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 132 kW at 380...400 V AC 50/60 Hz (AC-3)
140 kW at 415 V AC 50/60 Hz (AC-3)
140 kW at 440 V AC 50/60 Hz (AC-3)
160 kW at 500 V AC 50/60 Hz (AC-3)
160 kW at 660...690 V AC 50/60 Hz (AC-3)
147 kW at 1000 V AC 50/60 Hz (AC-3)
75 kW at 220...230 V AC 50/60 Hz (AC-3)
51 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))
Drop-out 0.15...0.2 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability 10 Mcycles
Inrush power in VA 650 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA 10 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate 2400 cyc/h 131 °F (55 °C)
Operating time 40...65 ms closing
100...170 ms opening
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 32 x 4 mm
Power circuit lugs-ring terminals 1 0.4 in² (240 mm²)
Power circuit connector 1 0.4 in² (240 mm²)
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 309.8 lbf.in (35 N.m)
Mounting Support Plate
Heat dissipation 8 W
motor power range 55…100 kW 200…240 V 3 phase
110…220 kW 480…500 V 3 phase
110…220 kW 380…440 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 240 V AC standard
Standards IEC 60947-4-1
EN 60947-4-1
JIS C8201-4-1
IEC 60947-1
EN 60947-1
Product Certifications UL
DNV
ABS
LROS (Lloyds register of shipping)
RINA
CB
CSA
BV
RMRoS
UKCA
Compatibility code LC1F
Control circuit type AC 40...400 Hz
Schneider New Stock Image
Schneider LC1F4002 Schneider
Sale price €1.775,95
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F330S121 Schneider
Sale price €288,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F265S121 Schneider
Sale price €528,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F265GD Schneider
Sale price €1.468,95
Only 2 units left

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-1
AC-4
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC-1
<= 690 V AC-3
<= 690 V AC-4
<= 460 V DC
[Uc] control circuit voltage 125 V DC
[Ie] rated operational current 350 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
265 A (at <131 °F (55 °C)) at <= 440 V AC AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 350 A (at 104 °F (40 °C))
Rated breaking capacity 2120 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 2200 A 104 °F (40 °C) - 10 s
1230 A 104 °F (40 °C) - 30 s
950 A 104 °F (40 °C) - 1 min
620 A 104 °F (40 °C) - 3 min
480 A 104 °F (40 °C) - 10 min
Associated fuse rating 315 A aM at <= 440 V
400 A gG at <= 440 V
Average impedance 0.3 mOhm - Ith 350 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 37 W AC-1
21 W AC-3
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 132 kW at 380...400 V AC 50/60 Hz (AC-3)
140 kW at 415 V AC 50/60 Hz (AC-3)
140 kW at 440 V AC 50/60 Hz (AC-3)
160 kW at 500 V AC 50/60 Hz (AC-3)
160 kW at 660...690 V AC 50/60 Hz (AC-3)
147 kW at 1000 V AC 50/60 Hz (AC-3)
75 kW at 220...230 V AC 50/60 Hz (AC-3)
51 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational 0.85...1.1 Uc 131 °F (55 °C))
Drop-out 0.15...0.2 Uc 131 °F (55 °C))
Mechanical durability 10 Mcycles
Inrush power in W 750 W 68 °F (20 °C))
Hold-in power consumption in W 5 W 68 °F (20 °C)
Maximum operating rate 2400 cyc/h 131 °F (55 °C)
Operating time 40...50 ms closing
40...65 ms opening
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 32 x 4 mm
Power circuit lugs-ring terminals 1 0.4 in² (240 mm²)
Power circuit connector 1 0.4 in² (240 mm²)
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 309.8 lbf.in (35 N.m)
Mounting Support Plate
Heat dissipation 5 W
motor power range 55…100 kW 200…240 V 3 phase
110…220 kW 480…500 V 3 phase
110…220 kW 380…440 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 125 V DC standard
Standards EN 60947-1
JIS C8201-4-1
IEC 60947-1
IEC 60947-4-1
EN 60947-4-1
Product Certifications BV
ABS
RMRoS
RINA
UL
DNV
CB
LROS (Lloyds register of shipping)
CSA
UKCA
Compatibility code LC1F
Control circuit type DC standard
Schneider New Stock Image
Schneider LC1F265E7 Schneider
Sale price€0,00
Sold Out

TeSys F contactor, 3 poles (3NO), 265A/1000V AC-3, for motor applications up to 132kW@400V. It provides a low sealed consumption 48V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Resistive load
Motor control
Utilisation category AC-3
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage <= 1000 V AC-1
<= 690 V AC-3
<= 690 V AC-4
<= 460 V DC
[Uc] control circuit voltage 48 V AC 40...400 Hz
[Ie] rated operational current 350 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
265 A (at <131 °F (55 °C)) at <= 440 V AC AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 350 A (at 104 °F (40 °C))
Rated breaking capacity 2120 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 2200 A 104 °F (40 °C) - 10 s
1230 A 104 °F (40 °C) - 30 s
950 A 104 °F (40 °C) - 1 min
620 A 104 °F (40 °C) - 3 min
480 A 104 °F (40 °C) - 10 min
Associated fuse rating 315 A aM at <= 440 V
400 A gG at <= 440 V
Average impedance 0.3 mOhm - Ith 350 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 37 W AC-1
21 W AC-3
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 132 kW at 380...400 V AC 50/60 Hz (AC-3)
140 kW at 415 V AC 50/60 Hz (AC-3)
140 kW at 440 V AC 50/60 Hz (AC-3)
160 kW at 500 V AC 50/60 Hz (AC-3)
160 kW at 660...690 V AC 50/60 Hz (AC-3)
147 kW at 1000 V AC 50/60 Hz (AC-3)
75 kW at 220...230 V AC 50/60 Hz (AC-3)
51 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))
Drop-out 0.15...0.2 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability 10 Mcycles
Inrush power in VA 650 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA 10 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate 2400 cyc/h 131 °F (55 °C)
Operating time 40...65 ms closing
100...170 ms opening
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 32 x 4 mm
Power circuit lugs-ring terminals 1 0.4 in² (240 mm²)
Power circuit connector 1 0.4 in² (240 mm²)
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 309.8 lbf.in (35 N.m)
Mounting Support Plate
Heat dissipation 8 W
motor power range 55…100 kW 200…240 V 3 phase
110…220 kW 480…500 V 3 phase
110…220 kW 380…440 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 48 V AC standard
Standards IEC 60947-4-1
EN 60947-1
EN 60947-4-1
JIS C8201-4-1
IEC 60947-1
Product Certifications RINA
RMRoS
CB
CSA
BV
ABS
LROS (Lloyds register of shipping)
DNV
UL
UKCA
Compatibility code LC1F
Control circuit type AC 40...400 Hz
Schneider New Stock Image
Schneider LC1F265G7 Schneider
Sale price €869,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F2600 Schneider
Sale price €14.863,95
Only 2 units left

Main

Characteristic Value(s)
Range TeSys
product name TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Resistive load
Utilisation category AC-1
Poles description 3P
power pole contact composition 3 NO
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
[Ie] rated operational current 2600 A 140 °F (60 °C)) <= 440 V AC AC-1

Complementary

Characteristic Value(s)
[Uc] control circuit voltage 110...500 V AC 40...400 Hz with LX1/LX9 coil
110...440 V DC with LX4 coil
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
[Ith] conventional free air thermal current 2600 A (at 140 °F (60 °C))
Irms rated making capacity 3900 A AC conforming to IEC 60947-4-1
Rated breaking capacity 3900 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 12000 A 104 °F (40 °C) - 10 s
9000 A 104 °F (40 °C) - 30 s
7000 A 104 °F (40 °C) - 1 min
6000 A 104 °F (40 °C) - 3 min
4000 A 104 °F (40 °C) - 10 min
Associated fuse rating 2500 A gG at <= 440 V
Average impedance 0.1 mOhm - Ith 2600 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
Power dissipation per pole 250 W AC-1
Control circuit voltage limits Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil
Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil
Operational: 0.85...1.1 Uc DC with LX4 coil
Drop-out: 0.2...0.35 Uc DC with LX4 coil
Heat dissipation 25 W
Operating time 40...80 ms closing with LX1/LX9 coil
100...200 ms opening with LX1/LX9 coil
60...70 ms closing with LX4 coil
40...50 ms opening with LX4 coil
Mounting Support Plate
Standards IEC 60947-1
IEC 60947-4-1
EN 60947-4-1
JIS C8201-4-1
EN 60947-1
Product Certifications cETLus
CCC
CSA
CB
UKCA
Connections - terminals Power circuit bar 3 100 x 10 mm
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)
Tightening torque Power circuit 513.3 lbf.in (58 N.m)
Control circuit 10.6 lbf.in (1.2 N.m)
Mechanical durability 0.5 Mcycles
Inrush power in VA 2200…2700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil
2130…2880 VA (at 68 °F (20 °C))with LX4 coil
Hold-in power consumption in VA 37.4…50.6 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil
13…25 VA (at 68 °F (20 °C))with LX4 coil
Maximum operating rate 600 cyc/h 131 °F (55 °C)
Compatibility code LC1F
Schneider New Stock Image
Schneider LC1F225BD Schneider
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F185U7 Schneider
Sale price €1.213,95
Only 1 unit left

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Resistive load
Motor control
Utilisation category AC-4
AC-1
AC-3
Poles description 3P
[Ue] rated operational voltage <= 460 V DC
<= 690 V AC 50/60 Hz
[Uc] control circuit voltage 240 V AC 40...400 Hz
[Ie] rated operational current 275 A (at <104 °F (40 °C)) at <= 440 V AC-1
185 A (at <131 °F (55 °C)) at <= 440 V AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 275 A (at 104 °F (40 °C))
Rated breaking capacity 1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 1500 A 104 °F (40 °C) - 10 s
920 A 104 °F (40 °C) - 30 s
740 A 104 °F (40 °C) - 1 min
500 A 104 °F (40 °C) - 3 min
400 A 104 °F (40 °C) - 10 min
Associated fuse rating 200 A aM at <= 440 V
315 A gG at <= 440 V
Average impedance 0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 12 W AC-3
25 W AC-1
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 90 kW at 380...400 V AC 50/60 Hz (AC-3)
100 kW at 415 V AC 50/60 Hz (AC-3)
100 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 660...690 V AC 50/60 Hz (AC-3)
55 kW at 220...230 V AC 50/60 Hz (AC-3)
33 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))
Drop-out 0.2...0.55 Uc 40...400 Hz 131 °F (55 °C))
Mechanical durability 10 Mcycles
Inrush power in VA 1070 VA, 40...400 Hz 0.9 68 °F (20 °C))
Hold-in power consumption in VA 9.9 VA, 40...400 Hz 0.9 68 °F (20 °C))
Maximum operating rate 2400 cyc/h 131 °F (55 °C)
Operating time 35 ms closing at Uc)
130 ms opening at Uc)
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 25 x 3 mm
Power circuit lugs-ring terminals 1 0.2 in² (150 mm²)
Power circuit connector 1 0.2 in² (150 mm²)
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 159.3 lbf.in (18 N.m)
Mounting Support Plate
Heat dissipation 8…9.8 W
motor power range 30…50 kW 200…240 V 3 phase
55…100 kW 200…240 V 3 phase
55…100 kW 380…440 V 3 phase
55…100 kW 480…500 V 3 phase
110…220 kW 480…500 V 3 phase
Motor starter type Direct on-line contactor
Contactor coil voltage 240 V AC standard
Standards IEC 60947-1
JIS C8201-4-1
EN 60947-1
IEC 60947-4-1
EN 60947-4-1
Product Certifications LROS (Lloyds register of shipping)
UL
CSA
BV
CB
DNV
RMRoS
RINA
ABS
UKCA
Compatibility code LC1F
Control circuit type AC 40...400 Hz
Schneider New Stock Image
Schneider LC1F185U6 Schneider
Sale price €1.053,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LC1F185Q5 Schneider
Sale price €660,95
Only 1 unit left

TeSys F contactor, 3 poles (3NO), 185A/690V AC-3, for motor applications up to 90kW@400V. It provides a 380V 50Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Range of Product TeSys F
Product or Component Type Contactor
Device short name LC1F
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage <= 460 V DC
<= 690 V AC 50/60 Hz
[Uc] control circuit voltage 380 V AC 50 Hz
[Ie] rated operational current 275 A (at <104 °F (40 °C)) at <= 440 V AC-1
185 A (at <131 °F (55 °C)) at <= 440 V AC-3

Complementary

Characteristic Value(s)
[Uimp] rated impulse withstand voltage 8 kV
[Ith] conventional free air thermal current 275 A (at 104 °F (40 °C))
Rated breaking capacity 1480 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 1500 A 104 °F (40 °C) - 10 s
920 A 104 °F (40 °C) - 30 s
740 A 104 °F (40 °C) - 1 min
500 A 104 °F (40 °C) - 3 min
400 A 104 °F (40 °C) - 10 min
Associated fuse rating 200 A aM at <= 440 V
315 A gG at <= 440 V
Average impedance 0.33 mOhm - Ith 275 A 50 Hz
[Ui] rated insulation voltage 1000 V IEC 60947-4-1
1500 V VDE 0110 group C
Power dissipation per pole 12 W AC-3
25 W AC-1
Overvoltage category III
power pole contact composition 3 NO
Motor power kW 90 kW at 380...400 V AC 50/60 Hz (AC-3)
100 kW at 415 V AC 50/60 Hz (AC-3)
100 kW at 440 V AC 50/60 Hz (AC-3)
110 kW at 500 V AC 50/60 Hz (AC-3)
110 kW at 660...690 V AC 50/60 Hz (AC-3)
55 kW at 220...230 V AC 50/60 Hz (AC-3)
33 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limits Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C))
Mechanical durability 10 Mcycles
Inrush power in VA 805 VA, 50 Hz 0.3 68 °F (20 °C))
Hold-in power consumption in VA 55 VA, 50 Hz 0.3 68 °F (20 °C))
Maximum operating rate 2400 cyc/h 131 °F (55 °C)
Operating time 20...35 ms closing
7...15 ms opening
Connections - terminals Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end
Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end
Power circuit bar 2 25 x 3 mm
Power circuit lugs-ring terminals 1 0.2 in² (150 mm²)
Power circuit connector 1 0.2 in² (150 mm²)
Power circuit bolted connection
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m)
Power circuit 159.3 lbf.in (18 N.m)
Mounting Support Plate
Heat dissipation 18…24 W
Standards EN 60947-1
JIS C8201-4-1
IEC 60947-1
EN 60947-4-1
IEC 60947-4-1
Product Certifications UL
LROS (Lloyds register of shipping)
RMRoS
CB
CCC
BV
ABS
RINA
DNV
Compatibility code LC1F
Control circuit type AC 50 Hz
Schneider New Stock Image
Schneider LC1F185G7 Schneider
Sale price €1.148,95
Only 4 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed