Schneider
Schneider

Schneider

25001 products

Showing 1321 - 1344 of 25001 products

Showing 1321 - 1344 of 25001 products
View
A9D17220 Schneider Electric
Schneider A9D17220 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 20 A - C Curve - 10000A/15kA - 30 mA - A type

A9D17225 Schneider Electric
Schneider A9D17225 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 25 A - C Curve - 10000A/15kA - 30 mA - A type

A9D17232 Schneider Electric
Schneider A9D17232 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 32 A - C Curve - 10000A/15kA - 30 mA - A type

Schneider Stock Image
Schneider A9D19820 Schneider
Sale price €327,95
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

A9D27210 Schneider Electric
Schneider A9D27210 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 10 A - C Curve - 10000A/15kA - 30 mA - SI type

A9D27216 Schneider Electric
Schneider A9D27216 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 16 A - C Curve - 10000A/15kA - 30 mA - SI type

A9D27220 Schneider Electric
Schneider A9D27220 Schneider Electric
Sale price€0,00
Sold Out

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P RCBO with 2 protected poles, rated current is 20A, and operating voltage is 220VAC to 240VAC. The earth leakage protection class is A-SI type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 220VAC to 240VAC is 10000A according to EN/IEC 61009-2-1. Breaking capacity at 220VAC to 240VAC is 15kA according to EN/IEC 60947-2. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 86mm x (D) 78mm. The weight is 273g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.

Main

Characteristic Value(s)
Range Acti9
product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60 RCBO
Device application Distribution
Poles description 2P
Number of protected poles 2
[In] rated current 20 A
Network type AC
Network frequency 50 Hz
Trip unit technology Thermal-magnetic
Curve code C
Earth-leakage sensitivity 30 mA
Suitability for isolation No conforming to IEC 60947-1
Quality labels NF
KEMA-KEUR
IMQ
VDE

Complementary

Characteristic Value(s)
Device location in system Outgoer
[Ue] rated operational voltage 220...240 V AC 50 Hz
Magnetic tripping limit 5...10 x In
Residual current tripping technology Voltage independent
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A-SI (Super Immunised)
Breaking capacity 10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
[Ics] rated service breaking capacity 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class 3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 3000 A
Contact position indicator No
control type Toggle
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
Bottom: biconnect
Connection pitch 9 mm between poles
9 mm pitches 4
Height 86 mm
Width 36 mm
Depth 78 mm
Product weight 273 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid
Tunnel type terminal top or bottom 1…25 mm² flexible
Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 12 mm for top or bottom connection
Tightening torque 2 N.m
Earth-leakage protection Integrated
A9D27225 Schneider Electric
Schneider A9D27225 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 25 A - C Curve - 10000A/15kA - 30 mA - SI type

A9D27232 Schneider Electric
Schneider A9D27232 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 32 A - C Curve - 10000A/15kA - 30 mA - SI type

Schneider Stock Image
Schneider A9D31620 Schneider
Sale price €366,95
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

A9D47210 Schneider Electric
Schneider A9D47210 Schneider Electric
Sale price€0,00
Sold Out

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P RCBO with 2 protected poles, rated current is 10A, and operating voltage is 220VAC to 240VAC. The earth leakage protection class is A-SI type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 220VAC to 240VAC is 10000A according to EN/IEC 61009-2-1. Breaking capacity at 220VAC to 240VAC is 15kA according to EN/IEC 60947-2. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 86mm x (D) 78mm. The weight is 273g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.

Main

Characteristic Value(s)
Range Acti9
product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60 RCBO
Device application Distribution
Poles description 2P
Number of protected poles 2
[In] rated current 10 A
Network type AC
Network frequency 50 Hz
Trip unit technology Thermal-magnetic
Curve code B
Earth-leakage sensitivity 30 mA
Suitability for isolation No conforming to IEC 60947-1
Quality labels IMQ
NF
VDE
KEMA-KEUR

Complementary

Characteristic Value(s)
Device location in system Outgoer
[Ue] rated operational voltage 220...240 V AC 50 Hz
Magnetic tripping limit 3...5 x In
Residual current tripping technology Voltage independent
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A-SI (Super Immunised)
Breaking capacity 10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
[Ics] rated service breaking capacity 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class 3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 3000 A
Contact position indicator No
control type Toggle
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
Bottom: biconnect
Connection pitch 9 mm between poles
9 mm pitches 4
Height 86 mm
Width 36 mm
Depth 78 mm
Product weight 273 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid
Tunnel type terminal top or bottom 1…25 mm² flexible
Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 12 mm for top or bottom connection
Tightening torque 2 N.m
Earth-leakage protection Integrated
A9D47216 Schneider Electric
Schneider A9D47216 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 16 A - B Curve - 10000A/15kA - 30 mA - SI type

A9D47220 Schneider Electric
Schneider A9D47220 Schneider Electric
Sale price€0,00
Sold Out

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 2P RCBO with 2 protected poles, rated current is 20A, and operating voltage is 220VAC to 240VAC. The earth leakage protection class is A-SI type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 220VAC to 240VAC is 10000A according to EN/IEC 61009-2-1. Breaking capacity at 220VAC to 240VAC is 15kA according to EN/IEC 60947-2. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 86mm x (D) 78mm. The weight is 273g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.

Main

Characteristic Value(s)
Range Acti9
product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60 RCBO
Device application Distribution
Poles description 2P
Number of protected poles 2
[In] rated current 20 A
Network type AC
Network frequency 50 Hz
Trip unit technology Thermal-magnetic
Curve code B
Earth-leakage sensitivity 30 mA
Suitability for isolation No conforming to IEC 60947-1
Quality labels NF
KEMA-KEUR
IMQ
VDE

Complementary

Characteristic Value(s)
Device location in system Outgoer
[Ue] rated operational voltage 220...240 V AC 50 Hz
Magnetic tripping limit 3...5 x In
Residual current tripping technology Voltage independent
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A-SI (Super Immunised)
Breaking capacity 10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
[Ics] rated service breaking capacity 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class 3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 3000 A
Contact position indicator No
control type Toggle
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
Bottom: biconnect
Connection pitch 9 mm between poles
9 mm pitches 4
Height 86 mm
Width 36 mm
Depth 78 mm
Product weight 273 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid
Tunnel type terminal top or bottom 1…25 mm² flexible
Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 12 mm for top or bottom connection
Tightening torque 2 N.m
Earth-leakage protection Integrated
A9D47225 Schneider Electric
Schneider A9D47225 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 25 A - B Curve - 10000A/15kA - 30 mA - SI type

A9D47232 Schneider Electric
Schneider A9D47232 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 32 A - B Curve - 10000A/15kA - 30 mA - SI type

A9D50210 Schneider Electric
Schneider A9D50210 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 10 A - C Curve - 10000A/15kA - 300 mA - AC type

A9D50216 Schneider Electric
Schneider A9D50216 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 16 A - C Curve - 10000A/15kA - 300 mA - AC type

A9D50220 Schneider Electric
Schneider A9D50220 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 20 A - C Curve - 10000A/15kA - 300 mA - AC type

A9D50225 Schneider Electric
Schneider A9D50225 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 25 A - C Curve - 10000A/15kA - 300 mA - AC type

A9D50232 Schneider Electric
Schneider A9D50232 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 2P - 32 A - C Curve - 10000A/15kA - 300 mA - AC type

A9D52410 Schneider Electric
Schneider A9D52410 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 4P - 10 A - C Curve - 6000A/6kA - 300 mA - A type

A9D52416 Schneider Electric
Schneider A9D52416 Schneider Electric
Sale price€0,00
Sold Out

Acti9 iC60 RCBO - 4P - 16 A - C Curve - 6000A/6kA - 300 mA - A type

A9D52420 Schneider Electric
Schneider A9D52420 Schneider Electric
Sale price€0,00
Sold Out

This Acti9 iC60 is a modular residual current breaker with overcurrent protection (RCBO). It is a 4P RCBO with 4 protected poles, rated current is 20A, and operating voltage is 380VAC to 415VAC. The earth leakage protection class is A type with a sensitivity of 300mA. The earth-leakage protection time delay is instantaneous. Breaking capacity at 280VAC to 415VAC is 6000A according to EN/IEC 61009-2-1 and 6kA according to EN/IEC 60947-2. Its fast closing mechanism independent of manual operation improves its service life. This product is compliant with EN/IEC 60947-2 and EN/IEC 61009-2-1 standards. Electrical endurance goes up to 10000 cycles, and mechanical endurance goes up to 20000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product color is white (RAL9003). The dimensions are (W) 72mm x (H) 86mm x (D) 78mm. The weight is 423g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 70°C.

Main

Characteristic Value(s)
Range Acti9
product name Acti9 iC60 RCBO
Product or component type Residual current breaker with overcurrent protection (RCBO)
Device short name iC60 RCBO
Device application Distribution
Poles description 4P
Number of protected poles 4
[In] rated current 20 A
Network type AC
Network frequency 50 Hz
Trip unit technology Thermal-magnetic
Curve code C
Earth-leakage sensitivity 300 mA
Suitability for isolation No conforming to IEC 60947-1
Quality labels NF
KEMA-KEUR
VDE
IMQ

Complementary

Characteristic Value(s)
Device location in system Outgoer
[Ue] rated operational voltage 380...415 V AC 50 Hz
Magnetic tripping limit 5...10 x In
Residual current tripping technology Voltage independent
Earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type A
Breaking capacity 6000 A Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1
6 kA Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
[Ics] rated service breaking capacity 6000 A 100 % x Icn at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1
6 kA 100 % x Icu at 380...415 V AC 50 Hz conforming to EN/IEC 60947-2
Rated breaking and making capacity Idm 6000 A at 380...415 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class 1 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage 500 V AC 50 Hz
[Uimp] rated impulse withstand voltage 4 kV
Surge current 250 A
Contact position indicator No
control type Toggle
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
Bottom: biconnect
Connection pitch 9 mm between poles
9 mm pitches 8
Height 86 mm
Width 72 mm
Depth 78 mm
Product weight 423 g
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid
Tunnel type terminal top or bottom 1…25 mm² flexible
Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 12 mm for top or bottom connection
Tightening torque 2 N.m
Earth-leakage protection Integrated