Schneider
Schneider

Schneider

25001 products

Showing 24361 - 24384 of 25001 products

Showing 24361 - 24384 of 25001 products
View
XPSAC1321P Schneider
Schneider XPSAC1321P Schneider
Sale price €323,95
Only 1 unit left

module XPSAC - Emergency stop - 48 V AC

XPSAC3421 Schneider
Schneider XPSAC3421 Schneider
Sale price €310,95
Only 1 unit left

This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAC
Safety module application For emergency stop and switch monitoring
Function of module Switch monitoring
Emergency stop
Safety level Can reach PL e/category 4 EN/ISO 13849-1
Can reach SILCL 3 EN/IEC 62061
Safety reliability data MTTFd = 210.4 years EN/ISO 13849-1
DC > 99 % EN/ISO 13849-1
PFHd = 3.56E-9 1/h EN/IEC 62061
Type of start Unmonitored
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 solid state output
[Us] Rated Supply Voltage 115 V AC - 15...15 %

Complementary

Characteristic Value(s)
Supply frequency 50/60 Hz
Maximum power consumption in VA 7 VA AC
[Uc] control circuit voltage 115 V
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 10.5 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 16 V relay output
Maximum response time on input open 100 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 2 LEDs
Current consumption 60 mA 115 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.46 lb(US) (0.21 kg)
XPSAC3421P Schneider
Schneider XPSAC3421P Schneider
Sale price €554,95
Only 2 units left

This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAC
Safety module application For emergency stop and switch monitoring
Function of module Switch monitoring
Emergency stop
Safety level Can reach PL e/category 4 EN/ISO 13849-1
Can reach SILCL 3 EN/IEC 62061
Safety reliability data MTTFd = 210.4 years EN/ISO 13849-1
DC > 99 % EN/ISO 13849-1
PFHd = 3.56E-9 1/h EN/IEC 62061
Type of start Unmonitored
Connections - terminals Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 solid state output
[Us] Rated Supply Voltage 115 V AC - 15...15 %

Complementary

Characteristic Value(s)
Supply frequency 50/60 Hz
Maximum power consumption in VA 7 VA AC
[Uc] control circuit voltage 115 V
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 10.5 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 16 V relay output
Maximum response time on input open 100 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 2 LEDs
Current consumption 60 mA 115 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.46 lb(US) (0.21 kg)
XPSAC3721 Schneider
Schneider XPSAC3721 Schneider
Sale price €268,95
Only 7 units left

This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAC
Safety module application For emergency stop and switch monitoring
Function of module Emergency stop
Switch monitoring
Safety level Can reach PL e/category 4 ISO 13849-1
Can reach SILCL 3 IEC 62061
Safety reliability data MTTFd = 210.4 years ISO 13849-1
DC > 99 % ISO 13849-1
PFHd = 3.56E-9 1/h IEC 62061
Type of start Unmonitored
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 solid state output
[Us] Rated Supply Voltage 230 V AC - 15...10 %

Complementary

Characteristic Value(s)
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA AC
[Uc] control circuit voltage 230 V
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 10.5 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 16 V relay output
Maximum response time on input open 100 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 2 LEDs
Current consumption 25 mA 230 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.46 lb(US) (0.21 kg)
XPSAC3721P Schneider
Schneider XPSAC3721P Schneider
Sale price€0,00
Sold Out

This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAC
Safety module application For emergency stop and switch monitoring
Function of module Emergency stop
Switch monitoring
Safety level Can reach PL e/category 4 EN/ISO 13849-1
Can reach SILCL 3 EN/IEC 62061
Safety reliability data MTTFd = 210.4 years EN/ISO 13849-1
DC > 99 % EN/ISO 13849-1
PFHd = 3.56E-9 1/h EN/IEC 62061
Type of start Unmonitored
Connections - terminals Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 solid state output
[Us] Rated Supply Voltage 230 V AC - 15...10 %

Complementary

Characteristic Value(s)
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA AC
[Uc] control circuit voltage 230 V
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 10.5 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 16 V relay output
Maximum response time on input open 100 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 2 LEDs
Current consumption 25 mA 230 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.46 lb(US) (0.21 kg)
XPSAC5121 Schneider
Schneider XPSAC5121 Schneider
Sale price €198,95
Only 8 units left

This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAC
Safety module application For emergency stop and switch monitoring
Function of module Emergency stop
Switch monitoring
Safety level Can reach PL e/category 4 ISO 13849-1
Can reach SILCL 3 IEC 62061
Safety reliability data MTTFd = 210.4 years ISO 13849-1
DC > 99 % ISO 13849-1
PFHd = 3.56E-9 1/h IEC 62061
Type of start Unmonitored
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 solid state output
[Us] Rated Supply Voltage 24 V AC - 20...10 %
24 V DC - 20...20 %

Complementary

Characteristic Value(s)
Supply frequency 50/60 Hz
Maximum power consumption in W 1.2 W DC
Maximum power consumption in VA 2.5 VA AC
[Uc] control circuit voltage 24 V
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 10.5 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 16 V relay output
Maximum response time on input open 100 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 2 LEDs
Current consumption 40 mA 24 V DC on power supply
90 mA 24 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.35 lb(US) (0.16 kg)
XPSAC5121P Schneider
Schneider XPSAC5121P Schneider
Sale price €252,95
Only 6 units left

module XPSAC - Emergency stop - 24 V AC DC

XPSAF5130 Schneider
Schneider XPSAF5130 Schneider
Sale price €165,95
Only 8 units left

This XPSAF safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and electrical monitoring of switches activated by protection devices conforming to standard EN/ISO 14119. 24V AC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAF
Safety module application For emergency stop and switch monitoring
Function of module Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard
Safety level Can reach PL e/category 4 ISO 13849-1
Can reach category 3 IEC 62061
Safety reliability data DC > 99 % ISO 13849-1
MTTFd = 243 years ISO 13849-1
PFHd = 4.62E-9 1/h IEC 62061
Type of start Configurable
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 0
[Us] Rated Supply Voltage 24 V AC - 15...10 %
24 V DC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs Unlimited
Supply frequency 50/60 Hz
Maximum power consumption in VA 5 VA AC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V
Maximum line resistance 90 Ohm
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 3 LEDs
Current consumption 30 mA 24 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.55 lb(US) (0.25 kg)
XPSAF5130P Schneider
Schneider XPSAF5130P Schneider
Sale price €719,95
Only 3 units left

module XPSAF - Emergency stop - 24 V AC DC

XPSAFL5130 Schneider
Schneider XPSAFL5130 Schneider
Sale price €417,95
Only 2 units left

This XPSAFL safety module monitors emergency shutdown pushbuttons, limit switches and light curtains. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and electrical monitoring of switches activated by protection devices conforming to standard EN/ISO 14119. And for monitoring of type 4 light curtains conforming to EN 61496-1 that have solid-state safety outputs, with a performance lLevel PL e/Category 4 in accordance with EN/ISO 13849-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It is compatible with emergency push buttons, limit switches and safety light curtains, the 3 most common safety sensors in the industry.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAF
Safety module application For emergency stop, switch and safety light curtain monitoring
Function of module Monitoring of electro-sensitive protection equipment (ESPE)
Monitoring of a movable guard
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Emergency stop monitoring 1-channel wiring
Multiple emergency stop monitoring 2-channel wiring
Safety level Can reach PL e/category 4 ISO 13849-1
Can reach SILCL 3 IEC 62061
Safety reliability data DC > 99 % ISO 13849-1
MTTFd = 172.1 years ISO 13849-1
PFHd = 5.61E-9 1/h IEC 62061
Type of start Unmonitored
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 0
[Us] Rated Supply Voltage 24 V AC - 15...10 %
24 V DC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs Unlimited
Supply frequency 50/60 Hz
Maximum power consumption in VA 5 VA AC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V
Maximum line resistance 90 Ohm
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 3 LEDs
Current consumption 30 mA 24 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.55 lb(US) (0.25 kg)
XPSAFL5130P Schneider
Schneider XPSAFL5130P Schneider
Sale price €546,95
Only 1 unit left

module XPSAF - Emergency stop - 24 V AC DC

XPSAK311144 Schneider
Schneider XPSAK311144 Schneider
Sale price €233,95
Only 6 units left

module XPSAK - Emergency stop - 24 V AC DC

XPSAK311144P Schneider
Schneider XPSAK311144P Schneider
Sale price €703,95
Only 6 units left

This XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAK
Safety module application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function of module Monitoring of a movable guard associated with 2 switches and automatic start
Monitoring of electro-sensitive protection equipment (ESPE)
Sensing mat and edges monitoring
Emergency stop monitoring 1-channel wiring
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Multiple emergency stop monitoring 2-channel wiring
Proximity sensor monitoring
Monitoring of a movable guard
Safety level Can reach PL e/category 4 ISO 13849-1
Can reach SILCL 3 IEC 62061
Safety reliability data DC > 99 % ISO 13849-1
MTTFd = 154.5 years ISO 13849-1
PFHd = 7.39E-9 1/h IEC 62061
Type of start Configurable
Connections - terminals Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 NC + 4 solid state outputs
[Us] Rated Supply Voltage 24 V AC - 15...10 %
24 V DC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs Unlimited (manual start)
2 or 4 s depending of wiring (automatic start)
Supply frequency 50/60 Hz
Maximum power consumption in VA 5 VA AC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum line resistance 28 Ohm
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 4 LEDs
Current consumption 30 mA 24 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.7 lb(US) (0.3 kg)
XPSAK331144P Schneider
Schneider XPSAK331144P Schneider
Sale price €421,95
Only 1 unit left

This XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of product Preventa Safety automation
Product or component type Preventa safety module
Safety module name XPSAK
Safety module application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function of module Proximity sensor monitoring
Monitoring of a movable guard
Monitoring of a movable guard associated with 2 switches and automatic start
Multiple emergency stop monitoring 2-channel wiring
Sensing mat and edges monitoring
Emergency stop monitoring 1-channel wiring
Monitoring of electro-sensitive protection equipment (ESPE)
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1
Can reach SILCL 3 conforming to EN/IEC 62061
Safety reliability data DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 154.5 years conforming to EN/ISO 13849-1
PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
Type of start Configurable
Connections - terminals Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO circuit(s), volt-free
Number of additional circuits 1 NC + 4 solid state outputs
[Us] rated supply voltage 48 V AC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs Unlimited (manual start)
2 or 4 s depending of wiring (automatic start)
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA AC
Input protection type Internal, electronic
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Output thermal current 6 A per relay for relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA for relay output
Minimum output voltage 17 V for relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
Local signalling 4 LEDs
Mounting support 35 mm symmetrical DIN rail
Product weight 0.3 kg
XPSAK351144 Schneider
Schneider XPSAK351144 Schneider
Sale price €885,95
Only 5 units left

module XPSAK - Emergency stop - 120 V AC

XPSAK351144P Schneider
Schneider XPSAK351144P Schneider
Sale price €1.580,95
Only 7 units left

module XPSAK - Emergency stop - 120 V AC

XPSAK361144 Schneider
Schneider XPSAK361144 Schneider
Sale price €658,95
Only 3 units left

This XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of product Preventa Safety automation
Product or component type Preventa safety module
Safety module name XPSAK
Safety module application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function of module Monitoring of electro-sensitive protection equipment (ESPE)
Monitoring of a movable guard associated with 2 switches and automatic start
Monitoring of a movable guard
Multiple emergency stop monitoring 2-channel wiring
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Sensing mat and edges monitoring
Proximity sensor monitoring
Emergency stop monitoring 1-channel wiring
Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1
Can reach SILCL 3 conforming to EN/IEC 62061
Safety reliability data DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 154.5 years conforming to EN/ISO 13849-1
PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
Type of start Configurable
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO circuit(s), volt-free
Number of additional circuits 1 NC + 4 solid state outputs
[Us] rated supply voltage 110 V AC - 15...10 %
24 V DC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs Unlimited (manual start)
2 or 4 s depending of wiring (automatic start)
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA AC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum line resistance 28 Ohm
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Output thermal current 6 A per relay for relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA for relay output
Minimum output voltage 17 V for relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
Local signalling 4 LEDs
Current consumption 30 mA at 24 V AC on power supply
Mounting support 35 mm symmetrical DIN rail
Product weight 0.4 kg
XPSAK361144P Schneider
Schneider XPSAK361144P Schneider
Sale price €652,95
Only 1 unit left

module XPSAK - Emergency stop - 110 V AC

XPSAK371144 Schneider
Schneider XPSAK371144 Schneider
Sale price €366,95
Only 10 units left

This XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAK
Safety module application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function of module Multiple emergency stop monitoring 2-channel wiring
Proximity sensor monitoring
Monitoring of a movable guard
Sensing mat and edges monitoring
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Emergency stop monitoring 1-channel wiring
Monitoring of a movable guard associated with 2 switches and automatic start
Monitoring of electro-sensitive protection equipment (ESPE)
Safety level Can reach PL e/category 4 EN/ISO 13849-1
Can reach SILCL 3 EN/IEC 62061
Safety reliability data DC > 99 % EN/ISO 13849-1
MTTFd = 154.5 years EN/ISO 13849-1
PFHd = 7.39E-9 1/h EN/IEC 62061
Type of start Configurable
Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 NC + 4 solid state outputs
[Us] Rated Supply Voltage 230 V AC - 15...10 %
24 V DC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs Unlimited (manual start)
2 or 4 s depending of wiring (automatic start)
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA AC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum line resistance 28 Ohm
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 4 LEDs
Current consumption 30 mA 24 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.9 lb(US) (0.4 kg)
XPSAK371144P Schneider
Schneider XPSAK371144P Schneider
Sale price €421,95
Only 2 units left

This XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.

Main

Characteristic Value(s)
Range of Product Preventa Safety automation
Product or Component Type Preventa safety module
Safety module name XPSAK
Safety module application For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
Function of module Monitoring of a movable guard
Monitoring of electro-sensitive protection equipment (ESPE)
Sensing mat and edges monitoring
Emergency stop monitoring 1-channel wiring
Multiple emergency stop monitoring 2-channel wiring
Proximity sensor monitoring
Monitoring of a movable guard associated with 2 switches and automatic start
Emergency stop with 2 NC contacts monitoring 2-channel wiring
Safety level Can reach PL e/category 4 EN/ISO 13849-1
Can reach SILCL 3 EN/IEC 62061
Safety reliability data DC > 99 % EN/ISO 13849-1
MTTFd = 154.5 years EN/ISO 13849-1
PFHd = 7.39E-9 1/h EN/IEC 62061
Type of start Configurable
Connections - terminals Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type Relay instantaneous opening, 3 NO, volt-free
Number of additional circuits 1 NC + 4 solid state outputs
[Us] Rated Supply Voltage 230 V AC - 15...10 %
24 V DC - 15...10 %

Complementary

Characteristic Value(s)
Synchronisation time between inputs 2 or 4 s depending of wiring (automatic start)
Unlimited (manual start)
Supply frequency 50/60 Hz
Maximum power consumption in VA 6 VA AC
Input protection type Internal, electronic
[Uc] control circuit voltage 24 V DC
Maximum line resistance 28 Ohm
Breaking capacity 180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
Breaking capacity 1.5 A 24 V DC-13)50 ms relay output
Output thermal current 6 A per relay relay output
[Ith] conventional free air thermal current 18 A
Associated fuse rating 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current 10 mA relay output
Minimum output voltage 17 V relay output
Maximum response time on input open 40 ms
[Ui] rated insulation voltage 300 V 2)IEC 60947-5-1
300 V 2)DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-1
4 kV III DIN VDE 0110 part 1
Local signalling 4 LEDs
Current consumption 30 mA 24 V AC on power supply
Mounting Support 35 mm symmetrical DIN rail
Product Weight 0.9 lb(US) (0.4 kg)
XPSAL5110_Schneider
Schneider XPSAL5110 Schneider
Sale price€0,00
Sold Out

BRAND NEW CONDITION, GUARANTEED.

Schneider Stock Image
Schneider XPSAR351144 Schneider
Sale price€0,00
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

XPSASF5142 Schneider Electric
Schneider XPSASF5142 Schneider Electric
Sale price€0,00
Sold Out
Unit Type of Package 1 PCE Number of Units in Package 1 1
XPSAT5110 Schneider
Schneider XPSAT5110 Schneider
Sale price €1.404,95
Only 6 units left

Main

Characteristic Value(s)
Device short name XPSAT
Range of product Preventa
Safety use category Instantaneous category 4 conforming to EN 954-1
Time delay category 3 conforming to EN 954-1

Complementary

Characteristic Value(s)
[Us] rated supply voltage 24 V
Contacts type and composition 1 NC
Electrical connection Screw clamp terminal
Number of safety circuits 3 NO for instantaneous
2 NO for time delayed
Pilot light 4 LED
Connector type terminal block connector

Recently viewed