Overload Relays

1026 products

Showing 769 - 792 of 1026 products

Showing 769 - 792 of 1026 products
View
LRD06C Schneider
Schneider LRD06C Schneider
Sale price €76,95
Only 7 units left

description not available

GV2L20 Schneider Electric
Schneider GV2L20 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 18 A, magnetic, rotary handle, screw clamp terminals

Schneider New Stock Image
Schneider GV3APN01 Schneider
Sale price €81,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV3L501 Schneider Electric
Schneider GV3L501 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or component type Motor circuit breaker
Device short name GV3L
Device application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-2
Motor power kW 22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
control type Rotary handle
[In] rated current 50 A
Magnetic tripping current 700 A
[Ith] conventional free air thermal current 50 A conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles for AC-3 at 415 V In
Tightening torque 5 N.m - on screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 55 mm
Height 114 mm
Depth 136 mm
Product weight 0.96 kg
Colour Dark grey
GV4PEM12S Schneider Electric
Schneider GV4PEM12S Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 12.5A, Icu 100kA, thermal magnetic multifunction, Everlink terminals

Schneider New Stock Image
Schneider GV3P5037-50 Schneider
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2ME143 Schneider Electric
Schneider GV2ME143 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, spring terminals

Schneider New Stock Image
Schneider GV3-P50 Schneider
Sale price €139,95
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV4PEM25N6 Schneider Electric
Schneider GV4PEM25N6 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic multifunction, lugs terminals

GV4LE02S6 Schneider Electric
Schneider GV4LE02S6 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 2A/690V, for protection of 3-phase motors 0.25-0.75kW@400V. It provides magnetic protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range of product TeSys GV4
Range TeSys Deca
Device short name GV4L
product name TeSys GV4
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 0.25 kW at 400...415 V AC 50/60 Hz
0.37 kW at 400...415 V AC 50/60 Hz
0.55 kW at 400...415 V AC 50/60 Hz
0.75 kW at 400...415 V AC 50/60 Hz
0.37 kW at 500 V AC 50/60 Hz
0.55 kW at 500 V AC 50/60 Hz
0.75 kW at 500 V AC 50/60 Hz
1.1 kW at 500 V AC 50/60 Hz
0.55 kW at 660...690 V AC 50/60 Hz
0.75 kW at 660...690 V AC 50/60 Hz
1.1 kW at 660...690 V AC 50/60 Hz
1.5 kW at 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 2 A
Magnetic tripping current 12…28 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connection pitch 27 mm without spreaders
35 mm with spreaders
Connections - terminals Lugs-ring terminals
Tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height 155 mm
Width 81 mm
Depth 116 mm
Product weight 1.5 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
GV7AE11 Schneider Electric
Schneider GV7AE11 Schneider Electric
Sale price€0,00
Sold Out

GV7AE11 is an auxiliary contact block for TeSys GV7 motor circuit breakers from Schneider Electric. Compatible with all GV7 models, it includes 1 NO/NC changeover contact rated for AC and DC operation and performs OF position or SD trip functions. GV7AE11 is an auxiliary contact block for TeSys GV7 motor circuit breakers from Schneider Electric. Compatible with all GV7 models, it is installed inside the circuit breaker. It includes 1 NO/NC changeover contact rated for AC operation until 690V and DC operation until 250V and performs OF poles position or SD trip indication depending on its internal position. Auxiliary contact block, NO+NC changeover type, to be located inside a GV7 circuit breaker. The internal position determines the function to be performed , OF poles position, SD trip indication. Fault discrimination between thermal or magnetic tripping is possible using a GV7AD111 or GV7AD112 auxiliary device. Rated for 50 000 Close-Open cycles operation in AC-12/AC-15 and DC-12/DC-14.

Main

Characteristic Value(s)
Range TeSys
Device short name GV7AE
Product or Component Type Auxiliary contact block
Device Application Signalling
Range compatibility TeSys TeSys GV5 motor circuit breaker
TeSys TeSys GV6 motor circuit breaker
TeSys TeSys GV7 motor circuit breaker
Auxiliary contact composition 1 C/O
Auxiliary contacts type Standard contacts
Auxiliary contacts operation Instantaneous
[Ith] conventional free air thermal current 6 A IEC 60947-5-1
[Ue] rated operational voltage <= 690 V AC 50/60 Hz
<= 250 V DC
[Ie] rated operational current 6 A AC-12 Ue: <= 690 V IEC 60947-5-1
6 A AC-15 Ue: <= 48 V IEC 60947-5-1
5 A AC-15 Ue: 110...127 V IEC 60947-5-1
4 A AC-15 Ue: 230...240 V IEC 60947-5-1
3 A AC-15 Ue: 380...440 V IEC 60947-5-1
0.1 A AC-15 Ue: 660...690 V IEC 60947-5-1
2.5 A DC-12 Ue: <= 48 V IEC 60947-5-1
0.8 A DC-12 Ue: 110 V IEC 60947-5-1
0.3 A DC-12 Ue: 250 V IEC 60947-5-1
1 A DC-14 Ue: <= 24 V IEC 60947-5-1
0.5 A DC-14 Ue: 48 V IEC 60947-5-1
0.2 A DC-14 Ue: 110 V IEC 60947-5-1
0.05 A DC-14 Ue: 250 V IEC 60947-5-1
Minimum switching current 5 mA
Minimum switching voltage 17 V

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 690 V IEC 60947-1
Protection type GG fuse 10 A maximum
GB2CB... circuit breaker 10 A maximum
Mechanical durability 50000 cycles
Mounting Location Inside the circuit breaker
Connections - terminals screw clamps terminals 1 0.002 in² (1.5 mm²)flexible with cable end
screw clamps terminals 1 0.002 in² (1.5 mm²)flexible without cable end
screw clamps terminals 1 0.002 in² (1.5 mm²)rigid
Product Weight 0.033 lb(US) (0.015 kg)
GV7AC07 Schneider Electric
Schneider GV7AC07 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV combination kit for circuit breaker and contactor association, for motor circuit breakers GV5, GV7. The kit comprises a depth adjustable metal bracket for mounting the breaker, links for the connection between circuit breaker and contactor, a cover on the links for protection against direct contact. For use with 3-pole contactors LC1F225, F265. Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Product or Component Type Kit for combination with connector
Device short name GV7AC
Range compatibility TeSys TeSys GV5 motor circuit breaker
TeSys TeSys GV7 motor circuit breaker
TeSys TeSys F contactor
Accessory / separate part category Connection accessory
Product Compatibility LC1F225
LC1F265

Complementary

Characteristic Value(s)
Kit composition Terminal screw type connector
Short terminal shield
Adjustable mounting bracket(s)
Quantity per Set Set of 1
Product Weight 1.21 lb(US) (0.55 kg)
GV4PEM50N Schneider Electric
Schneider GV4PEM50N Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PEM
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Electronic
Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 11 kW 400...415 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 660...690 V AC 50/60 Hz
15 kW 400...415 V AC 50/60 Hz
18.5 kW 400...415 V AC 50/60 Hz
22 kW 400...415 V AC 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
22 kW 500 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
22 kW 660...690 V AC 50/60 Hz
30 kW 660...690 V AC 50/60 Hz
37 kW 660...690 V AC 50/60 Hz
45 kW 660...690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
15 kA Icu 525 V AC 50/60 Hz IEC 60947-2
65 kA 208Y/120 V AC 50/60 Hz UL 60947
65 kA 240 V AC 50/60 Hz UL 60947
35 kA 480Y/277 V AC 50/60 Hz UL 60947
8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 50 A
Magnetic tripping current 850 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 20000 cycles AC-3 440 V In/2
10000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors top) 1 0.002…0.1 in² (1.5…70 mm²) - solid
EverLink BTR screw connectors top) 1 0.002…0.08 in² (1.5…50 mm²) - flexible
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…95 mm²) - solid
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…70 mm²) - flexible
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
GV2L05 Schneider Electric
Schneider GV2L05 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for 3-phase motor applications 0.25-0.37kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD05 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2L
Device Application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 0.25 kW 400/415 V AC 50/60 Hz
0.37 kW 400/415 V AC 50/60 Hz
0.37 kW 500 V AC 50/60 Hz
0.55 kW 690 V AC 50/60 Hz
0.75 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
100 % 500 V AC 50/60 Hz IEC 60947-2
100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Rotary handle
Line Rated Current 1 A
Magnetic tripping current 15.1 A
[Ith] conventional free air thermal current 1 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 1.8 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 2 x M4 screws)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.8 in (97 mm)
Product Weight 0.73 lb(US) (0.33 kg)
color Dark grey
GV2ME10C Schneider
Schneider GV2ME10C Schneider
Sale price €87,95
Only 9 units left

Motor circuit breaker, TeSys Deca, 3P, 4 to 6.3A, thermal magnetic, screw clamp terminals, button control

GV2RT163 Schneider Electric
Schneider GV2RT163 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or component type Motor circuit breaker
Device short name GV2RT
Device application Motor protection
Transformer
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-2
Motor power kW 2.2 kW at 220/230 V AC 50/60 Hz motor protection high peak current
3 kW at 220/230 V AC 50/60 Hz motor protection high peak current
5.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current
5.5 kW at 440 V AC 50/60 Hz motor protection high peak current
7.5 kW at 440 V AC 50/60 Hz motor protection high peak current
7.5 kW at 500 V AC 50/60 Hz motor protection high peak current
9 kW at 690 V AC 50/60 Hz motor protection high peak current
11 kW at 690 V AC 50/60 Hz motor protection high peak current
4 kW at 230/240 V AC 50/60 Hz transformer protection
6.3 kW at 400/415 V AC 50/60 Hz transformer protection
10 kW at 690 V AC 50/60 Hz transformer protection
12.5 kW at 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 14 A
Thermal protection adjustment range 9…14 A conforming to IEC 60947-2
Magnetic tripping current 280 A
[Ith] conventional free air thermal current 14 A conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated duty Uninterrupted conforming to IEC 60947-4-1
Connections - terminals Power circuit: spring terminals 2 cable(s) 1…6 mm²solid
Power circuit: spring terminals 2 cable(s) 1.5…4 mm²flexible without cable end
Power circuit: spring terminals 2 cable(s) 1…4 mm²flexible with cable end
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Mounting position Horizontal
Vertical
Width 45 mm
Height 89 mm
Depth 78.5 mm
GVAPH02 Schneider Electric
Schneider GVAPH02 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Product or Component Type Mounting bracket
Device short name GVAP
Accessory / separate part category Control accessory

Complementary

Characteristic Value(s)
Product Compatibility GV2APN01
GV2APN02
GV2APN03
GV2APN04
Height 6.9 in (174 mm)
Width 2.6 in (65 mm)
Depth 5.9 in (151 mm)
Product Weight 0.7 lb(US) (0.3 kg)
Schneider New Stock Image
Schneider GV3P65GVAN11 Schneider
Sale price €148,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider GV2ME03C Schneider
Sale price €88,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV1L3 Schneider Electric
Schneider GV1L3 Schneider Electric
Sale price€0,00
Sold Out

Current limiter module, TeSys GV2, on device mounting

GVAU225 Schneider Electric
Schneider GVAU225 Schneider Electric
Sale price€0,00
Sold Out

Undervoltage release (MN), TeSys GV2-GV3, 220-240V AC 50 Hz

GV4PE115S6 Schneider Electric
Schneider GV4PE115S6 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PE
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Thermal-magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 37 kW 400...415 V AC 50/60 Hz
45 kW 400...415 V AC 50/60 Hz
55 kW 400...415 V AC 50/60 Hz
45 kW 500 V AC 50/60 Hz
55 kW 500 V AC 50/60 Hz
75 kW 500 V AC 50/60 Hz
75 kW 660...690 V AC 50/60 Hz
90 kW 660...690 V AC 50/60 Hz
110 kW 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
70 kA Icu 440 V AC 50/60 Hz IEC 60947-2
30 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA Icu 525 V AC 50/60 Hz IEC 60947-2
100 kA 208Y/120 V AC 50/60 Hz UL 60947
100 kA 240 V AC 50/60 Hz UL 60947
65 kA 480Y/277 V AC 50/60 Hz UL 60947
10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 115 A
Magnetic tripping current 1955 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 10000 cycles AC-3 440 V In/2
5000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connection pitch 1.06 in (27 mm) without spreaders
1.4 in (35 mm) with spreaders
Connections - terminals Lugs-ring terminals
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
Schneider New Stock Image
Schneider LRD16 Schneider
Sale price €92,95
In stock, 12 units

TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 9 to 13 amperes. This trip current rating is calibrated per Class 10A. Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
product name TeSys LRD
TeSys Deca
Product or Component Type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product Compatibility LC1D18
LC1D38
LC1D32
LC1D12
LC1D25
Network type DC
AC
Thermal overload class Class 10A IEC 60947-4-1
Thermal protection adjustment range 9…13 A
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 690 V IEC 60947-4-1

Complementary

Characteristic Value(s)
Network Frequency 0...400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A signalling circuit
Permissible current 1.5 A 240 V AC-15 signalling circuit
0.1 A 250 V DC-13 signalling circuit
[Ue] rated operational voltage 690 V AC 0...400 Hz power circuit IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button stop
Blue push-button reset
Temperature compensation -4…140 °F (-20…60 °C)
Connections - terminals Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid
Power circuit screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) solid
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Height 2.6 in (66 mm)
Width 1.8 in (45 mm)
Depth 2.8 in (70 mm)
Product Weight 0.273 lb(US) (0.124 kg)
GV2ME08TQ Schneider
Schneider GV2ME08TQ Schneider
Sale price €85,95
In stock, 11 units

Motor circuit breaker,TeSys Deca frame 2,3P,2.5-4A,thermal magnetic,push button,screw clamp terminals,bulk qty

Recently viewed