Overload Relays

1026 products

Showing 553 - 576 of 1026 products

Showing 553 - 576 of 1026 products
View
GV4LE80N Schneider Electric
Schneider GV4LE80N Schneider Electric
Sale price €330,95
Only 1 unit left

Motor circuit breaker, TeSys GV4, 3P, 80 A, Icu 50 kA, magnetic, EverLink terminals

GV4LE07S Schneider Electric
Schneider GV4LE07S Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. It provides magnetic protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range of product TeSys GV4
Range TeSys Deca
Device short name GV4L
product name TeSys GV4
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 1.5 kW at 400...415 V AC 50/60 Hz
2.2 kW at 400...415 V AC 50/60 Hz
2.5 kW at 400...415 V AC 50/60 Hz
3 kW at 400...415 V AC 50/60 Hz
2.2 kW at 500 V AC 50/60 Hz
2.5 kW at 500 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
3 kW at 660...690 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 7 A
Magnetic tripping current 42…98 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height 155 mm
Width 81 mm
Depth 116 mm
Product weight 1.5 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
LRD05 Schneider
Schneider LRD05 Schneider
Sale price €80,95
Only 9 units left

TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 0.63 to 1.0 amperes. This trip current rating is calibrated per Class 10A. Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
product name TeSys LRD
TeSys Deca
Product or Component Type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product Compatibility LC1D25
LC1D38
LC1D12
LC1D32
LC1D18
LC1D09
Network type AC
DC
Thermal overload class Class 10A IEC 60947-4-1
Thermal protection adjustment range 0.63…1 A
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 690 V IEC 60947-4-1

Complementary

Characteristic Value(s)
Network Frequency 0...400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A signalling circuit
Permissible current 3 A 120 V AC-15 signalling circuit
0.22 A 125 V DC-13 signalling circuit
[Ue] rated operational voltage 690 V AC 0...400 Hz power circuit IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button stop
Blue push-button reset
Temperature compensation -4…140 °F (-20…60 °C)
Connections - terminals Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end
Power circuit screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Height 2.6 in (66 mm)
Width 1.8 in (45 mm)
Depth 2.8 in (70 mm)
Product Weight 0.273 lb(US) (0.124 kg)
GV4PEM12S6 Schneider Electric
Schneider GV4PEM12S6 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 12.5A, Icu 100kA, thermal magnetic multifunction, lugs terminals

GV4PEM02N Schneider Electric
Schneider GV4PEM02N Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 2A/690V, for protection of 3-phase motors 0.25-0.75kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 0.8-2A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PEM
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Thermal-magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 0.25 kW 400...415 V AC 50/60 Hz
0.37 kW 400...415 V AC 50/60 Hz
0.55 kW 400...415 V AC 50/60 Hz
0.75 kW 400...415 V AC 50/60 Hz
0.37 kW 500 V AC 50/60 Hz
0.55 kW 500 V AC 50/60 Hz
0.75 kW 500 V AC 50/60 Hz
1.1 kW 500 V AC 50/60 Hz
0.55 kW 660...690 V AC 50/60 Hz
0.75 kW 660...690 V AC 50/60 Hz
1.1 kW 660...690 V AC 50/60 Hz
1.5 kW 660...690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
15 kA Icu 525 V AC 50/60 Hz IEC 60947-2
65 kA 208Y/120 V AC 50/60 Hz UL 60947
65 kA 240 V AC 50/60 Hz UL 60947
35 kA 480Y/277 V AC 50/60 Hz UL 60947
8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 2 A
Magnetic tripping current 34 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles AC-3 440 V In/2
40000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors top) 1 0.002…0.1 in² (1.5…70 mm²) - solid
EverLink BTR screw connectors top) 1 0.002…0.08 in² (1.5…50 mm²) - flexible
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…95 mm²) - solid
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…70 mm²) - flexible
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
GV4LE25B6 Schneider Electric
Schneider GV4LE25B6 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 25 A, Icu 25 kA, magnetic, lugs terminals

GV7AS207 Schneider Electric
Schneider GV7AS207 Schneider Electric
Sale price€0,00
Sold Out

Voltage release, TeSys GV5 GV6 GV7, MX shunt trip, 200-240V AC 50/60Hz

GV2RT053 Schneider Electric
Schneider GV2RT053 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or component type Motor circuit breaker
Device short name GV2RT
Device application Motor protection
Motor
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Motor power kW 0.09 kW at 220/230 V AC 50/60 Hz motor protection high peak current
0.12 kW at 220/230 V AC 50/60 Hz motor protection high peak current
0.25 kW at 400/415 V AC 50/60 Hz motor protection high peak current
0.37 kW at 400/415 V AC 50/60 Hz motor protection high peak current
0.25 kW at 440 V AC 50/60 Hz motor protection high peak current
0.37 kW at 440 V AC 50/60 Hz motor protection high peak current
0.37 kW at 500 V AC 50/60 Hz motor protection high peak current
0.55 kW at 690 V AC 50/60 Hz motor protection high peak current
0.63 kW at 440 V AC 50/60 Hz transformer protection
0.63 kW at 500 V AC 50/60 Hz transformer protection
1 kW at 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 1 A
Thermal protection adjustment range 0.63…1 A conforming to IEC 60947-4-1
Magnetic tripping current 22 A
[Ith] conventional free air thermal current 1 A conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated duty Continuous conforming to IEC 60947-4-1
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Mounting position Horizontal
Vertical
Width 45 mm
Height 89 mm
Depth 78.5 mm
Schneider New Stock Image
Schneider LRD3361 Schneider
Sale price €135,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2RT16 Schneider Electric
Schneider GV2RT16 Schneider Electric
Sale price €469,95
Only 2 units left

TeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for high starting current peak motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 9-14A, a magnetic tripping level at 20xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2RT
Device Application Motor protection
Transformer
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 2.2 kW 220/230 V AC 50/60 Hz motor protection high peak current
3 kW 220/230 V AC 50/60 Hz motor protection high peak current
5.5 kW 400/415 V AC 50/60 Hz motor protection high peak current
5.5 kW 440 V AC 50/60 Hz motor protection high peak current
7.5 kW 440 V AC 50/60 Hz motor protection high peak current
7.5 kW 500 V AC 50/60 Hz motor protection high peak current
9 kW 690 V AC 50/60 Hz motor protection high peak current
11 kW 690 V AC 50/60 Hz motor protection high peak current
4 kW 230/240 V AC 50/60 Hz transformer protection
6.3 kW 400/415 V AC 50/60 Hz transformer protection
6.3 kW 440 V AC 50/60 Hz transformer protection
10 kW 690 V AC 50/60 Hz transformer protection
12.5 kW 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2
15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
8 kA Icu 440 V AC 50/60 Hz IEC 60947-2
6 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Control Type Toggle
Line Rated Current 14 A
Thermal protection adjustment range 9…14 A IEC 60947-2
Magnetic tripping current 280 A
[Ith] conventional free air thermal current 14 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
Schneider Stock Image
Schneider GV4PB80B Schneider
Sale price €845,95
Only 5 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Schneider New Stock Image
Schneider GV2-ME14 Schneider
Sale price €99,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV4AU415 Schneider Electric
Schneider GV4AU415 Schneider Electric
Sale price€0,00
Sold Out

MN - undervoltage release - 380...415 V AC 50Hz - for TeSys GV4

Schneider New Stock Image
Schneider LRD-14 Schneider
Sale price €82,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LRN-12N Schneider
Sale price €82,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider Stock Image
Schneider GV7RE150 Schneider
Sale price €821,95
Only 3 units left
Buy the Schneider Electric GV7RE150 - a genuine Schneider Electric industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Schneider Electric GV7RE150 is a direct drop-in replacement for existing installations and ships ready for integration.
GVAX226 Schneider Electric
Schneider GVAX226 Schneider Electric
Sale price€0,00
Sold Out

Undervoltage release (MN), TeSys GV2, 220-240 V AC 60 Hz, safety device for use with GV2ME

Schneider New Stock Image
Schneider GV2-ME20C Schneider
Sale price €88,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV3L321 Schneider Electric
Schneider GV3L321 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or component type Motor circuit breaker
Device short name GV3L
Device application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-2
Motor power kW 15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz
100 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
control type Rotary handle
[In] rated current 32 A
Magnetic tripping current 448 A
[Ith] conventional free air thermal current 32 A conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles for AC-3 at 415 V In
Tightening torque 5 N.m - on screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 55 mm
Height 114 mm
Depth 136 mm
Product weight 0.96 kg
Colour Dark grey
Schneider New Stock Image
Schneider LRN22N Schneider
Sale price €76,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider GV2-PM32C Schneider
Sale price €95,95
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2AK00 Schneider Electric
Schneider GV2AK00 Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Device short name GV2AK
Product or Component Type Visible isolation blocks
Accessory / separate part category Connection accessory

Complementary

Characteristic Value(s)
Range compatibility TeSys TeSys GV2 GV2L
TeSys TeSys GV2 GV2P
Poles description 3P
Mounting Location Top
Line Rated Current 0.1…25 A
Product Weight 0.33 lb(US) (0.15 kg)
Schneider New Stock Image
Schneider LRD3361C Schneider
Sale price €92,95
In stock, 11 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2L03 Schneider Electric
Schneider GV2L03 Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 0.4 A, magnetic, rotary handle, screw clamp terminals

Recently viewed