Overload Relays

930 products

Showing 25 - 48 of 930 products

Showing 25 - 48 of 930 products
View
GVAN11 Schneider Electric
Schneider GVAN11 Schneider Electric
Sale price €68,95
Only 8 units left

TeSys GV2 & GV3 - auxiliary contact block - 1 NO + 1 NC

Schneider New Stock Image
Schneider GV3-P40 Schneider
Sale price €134,95
Only 8 units left

The GV3 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV3PE controls motors with full load currents up to 65 amperes. The manual starter is three pole with horsepower ratings. The manual starter is operated by a rotary handle. The Class 10 ambient compensated thermal over current is adjustable from 30 ampere to 40 ampere. This device has EVERLINK terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or Component Type Motor circuit breaker
Device short name GV3P
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 18.5 kW 400/415 V AC 50/60 Hz
22 kW 500 V AC 50/60 Hz
37 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
12 kA Icu 500 V AC 50/60 Hz IEC 60947-2
6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
50 % 500 V AC 50/60 Hz IEC 60947-2
50 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Rotary handle
Line Rated Current 40 A
Thermal protection adjustment range 30…40 A IEC 60947-2
Magnetic tripping current 560 A
[Ith] conventional free air thermal current 40 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles AC-3 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Tightening torque 44.3 lbf.in (5 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 2.2 in (55 mm)
Height 5.2 in (132 mm)
Depth 5.4 in (136 mm)
Product Weight 2.12 lb(US) (0.96 kg)
color Dark grey
GV2ME06 Schneider Electric
Schneider GV2ME06 Schneider Electric
Sale price €86,95
Only 5 units left

The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 1 ampere to 1.6 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2ME
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 0.37 kW 400/415 V AC 50/60 Hz
0.55 kW 400/415 V AC 50/60 Hz
0.37 kW 500 V AC 50/60 Hz
0.55 kW 500 V AC 50/60 Hz
0.75 kW 500 V AC 50/60 Hz
0.75 kW 690 V AC 50/60 Hz
1.1 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
100 % 500 V AC 50/60 Hz IEC 60947-2
100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Push-button
Line Rated Current 1.6 A
Thermal protection adjustment range 1…1.6 A IEC 60947-2
Magnetic tripping current 26.2 A
[Ith] conventional free air thermal current 1.6 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
Product Weight 0.57 lb(US) (0.26 kg)
color Dark grey
LRD06 Schneider
Schneider LRD06 Schneider
Sale price €79,95
Only 8 units left

TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 1.0 to 1.7 amperes. This trip current rating is calibrated per Class 10A. Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
product name TeSys LRD
TeSys Deca
Product or Component Type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product Compatibility LC1D25
LC1D32
LC1D12
LC1D18
LC1D38
LC1D09
Network type DC
AC
Thermal overload class Class 10A IEC 60947-4-1
Thermal protection adjustment range 1…1.6 A
[Ui] rated insulation voltage Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 690 V IEC 60947-4-1

Complementary

Characteristic Value(s)
Network Frequency 0...400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A signalling circuit
Permissible current 3 A 120 V AC-15 signalling circuit
0.22 A 125 V DC-13 signalling circuit
[Ue] rated operational voltage 690 V AC 0...400 Hz power circuit IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button stop
Blue push-button reset
Temperature compensation -4…140 °F (-20…60 °C)
Connections - terminals Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end
Power circuit screw clamp terminals 1 0.002…0.02 in² (1.5…10 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) flexible with cable end
Power circuit screw clamp terminals 1 0.002…0.009 in² (1…6 mm²) solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Height 2.6 in (66 mm)
Width 1.8 in (45 mm)
Depth 2.8 in (70 mm)
Product Weight 0.273 lb(US) (0.124 kg)
LRD3363C Schneider
Schneider LRD3363C Schneider
Sale price €87,95
In stock, 11 units

TeSys LRD thermal overload relays - 63...80 A - class 10A

Schneider Stock Image
Schneider GV7RE100 Schneider
Sale price €593,95
Only 4 units left
Buy the Schneider Electric GV7RE100 Circuit Breaker - an industrial molded case circuit breaker providing overcurrent and short-circuit protection for electrical distribution. Features thermal-magnetic or electronic trip, high interrupting capacity, and UL/IEC ratings. The Schneider Electric GV7RE100 is a direct replacement for existing breaker installations.
GV2P22 Schneider Electric
Schneider GV2P22 Schneider Electric
Sale price €127,95
Only 6 units left

Motor circuit breaker, TeSys GV2, 3P, 20-25 A, thermal magnetic, screw clamp terminals

LR9F5371_Schneider
Schneider LR9F5371 Schneider
Sale price €924,95
Only 3 units left

TeSys LR9F electronic overload relay, thermal setting range 132-220A, class 10, for protection of motors 90-110kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F185, F225, F265, use of a support mounting plate LA7F901 is recommended (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop & reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs/Reach).

Main

Characteristic Value(s)
Range TeSys
product name TeSys LRF
Device short name LR9F
Product or Component Type Electronic thermal overload relay
Relay application Motor protection
Product Compatibility LC1F185...LC1F265
Network type AC
Thermal overload class Class 10 IEC 60947-4
Thermal protection adjustment range 132…220 A

Complementary

Characteristic Value(s)
Network Frequency 50/60 Hz
Mounting support Direct on contactor
Plate
Tripping threshold 1.12 +/- 0.06 In tripping IEC 60947-4-1
Surge withstand 4 kV IEC 61000-4-5
Contacts type and composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A control circuit
[Ue] rated operational voltage 1000 V AC 50/60 Hz power circuit VDE 0110 group C
[Ui] rated insulation voltage Power circuit 1000 V AC IEC 60947-4
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-1
Phase failure sensitivity Tripping in 4 s +/- 20 % IEC 60947-4-1
Reset Manual reset on front relay
Control type Dial White full-load current adjustment
Test button Red
Push-button Red reset
Push-button stop
Local signalling Trip indicator
Temperature compensation -4…158 °F (-20…70 °C)
Current consumption <= 5 mA no-load
switching capacity for alarm 0...150 mA
Maximum voltage drop <2.5 V closed state
Connections - terminals Control circuit screw clamp terminals 1 0.001…0.004 in² (0.75…2.5 mm²) flexible - with cable end
Control circuit screw clamp terminals 1 0.001…0.004 in² (0.75…2.5 mm²) solid
Control circuit screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²) flexible - without cable end
Control circuit screw clamp terminals 2 0.002…0.002 in² (1…1.5 mm²) flexible - with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible - without cable end
Control circuit screw clamp terminals 2 0.002 in² (1 mm²) solid
Power circuit lugs-ring terminals M10
Tightening torque Control circuit 1.2 N.m screw clamp terminals
Power circuit 35 N.m screw clamp terminals
Height 4.0 in (101 mm)
Width 4.5 in (115 mm)
Depth 4.9 in (123.5 mm)
Product Weight 2.09 lb(US) (0.95 kg)
GV2ME05 Schneider Electric
Schneider GV2ME05 Schneider Electric
Sale price €90,95
Only 7 units left

The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 0.63 ampere to 1 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2ME
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 0.25 kW 400/415 V AC 50/60 Hz
0.55 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
100 % 500 V AC 50/60 Hz IEC 60947-2
100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Push-button
Line Rated Current 1 A
Thermal protection adjustment range 0.63…1 A IEC 60947-2
Magnetic tripping current 15.1 A
[Ith] conventional free air thermal current 1 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
Product Weight 0.62 lb(US) (0.28 kg)
color Dark grey
GV3L50 Schneider Electric
Schneider GV3L50 Schneider Electric
Sale price €142,95
Only 9 units left

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for 3-phase motor applications 22kW@400V. It provides a magnetic protection with a tripping level at 14xIn, high breaking capacity Icu 50kA@400V. Connection by Everlink BTR screw terminals. Start-stop control by rotary handle guaranteed for 50 000 cycles AC-3. To complete motor protection, use it in association with a thermal overload relay LRD350 (to be ordered separately). Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or Component Type Motor circuit breaker
Device short name GV3L
Device Application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 22 kW 400/415 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
45 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz
50 kA Icu 400/415 V AC 50/60 Hz
50 kA Icu 440 V AC 50/60 Hz
12 kA Icu 500 V AC 50/60 Hz
6 kA Icu 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz
100 % 400/415 V AC 50/60 Hz
100 % 440 V AC 50/60 Hz
50 % 500 V AC 50/60 Hz
50 % 690 V AC 50/60 Hz
Control Type Rotary handle
Line Rated Current 50 A
Magnetic tripping current 700 A
[Ith] conventional free air thermal current 50 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles AC-3 415 V In
Tightening torque 44.3 lbf.in (5 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 2.2 in (55 mm)
Height 5.2 in (132 mm)
Depth 5.4 in (136 mm)
Product Weight 2.12 lb(US) (0.96 kg)
color Dark grey
Schneider New Stock Image
Schneider LRD4369 Schneider
Sale price €132,95
In stock, 12 units

LRD4369 is a TeSys LRD thermal overload relay from Schneider Electric to be used with a TeSys D contactor. It protects motors 63kW@400V thanks to a thermal range 110-140A, a tripping class 10A and phase unbalance protection. LRD4369 is a TeSys LRD thermal overload relay from Schneider Electric for direct mounting on TeSys D contactors. With a thermal setting range 110-140A, a tripping class 10A and phase unbalance detection, it protects motors 63kW@400V. It provides manual test & reset buttons, automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine). Thermal overload protection relay, bimetallic type, with phase unbalance protection (differential). Direct mounting on the bottom terminals of a Tesys contactor LC1D150 to form a compact starter. Light and compact, 120mm wide. Temperature compensated for a good accuracy of the protection. Manual control with test & reset buttons, manual / automatic reset selector. Trip signaling with 1NO+1NC auxiliary contacts and trip flag indicator. Can be completed with terminal blocks for separate mounting (LAD7B, LAD96) and remote control devices (LAD703, LA7D03).

Main

Characteristic Value(s)
Range TeSys
product name TeSys LRD
TeSys Deca
Product or Component Type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product Compatibility LC1D150
Network type DC
AC
Thermal overload class Class 10A IEC 60947-4-1
Thermal protection adjustment range 110…140 A
[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1

Complementary

Characteristic Value(s)
Network Frequency 0...400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A signalling circuit
Permissible current 0.06 A 440 V DC-13 signalling circuit
0.12 A 600 V AC-15 signalling circuit
[Ue] rated operational voltage 1000 V AC 0...400 Hz power circuit IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-1
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button stop
Blue push-button reset
Temperature compensation -4…140 °F (-20…60 °C)
Connections - terminals Power circuit screw clamp terminals 1 0.006…0.05 in² (4…35 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end
Power circuit screw clamp terminals 1 0.006…0.08 in² (4…50 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.006…0.08 in² (4…50 mm²) solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 79.7 lbf.in (9 N.m) screw clamp terminals
Depth 5.2 in (132 mm)
Product Weight 2.0 lb(US) (0.9 kg)
GV2ME21 Schneider Electric
Schneider GV2ME21 Schneider Electric
Sale price €104,95
Only 9 units left

The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 17 ampere to 23 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2ME
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 9 kW 400/415 V AC 50/60 Hz
11 kW 500 V AC 50/60 Hz
18.5 kW 690 V AC 50/60 Hz
Breaking capacity 50 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
6 kA Icu 440 V AC 50/60 Hz IEC 60947-2
4 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
40 % 400/415 V AC 50/60 Hz IEC 60947-2
50 % 440 V AC 50/60 Hz IEC 60947-2
75 % 500 V AC 50/60 Hz IEC 60947-2
75 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Push-button
Line Rated Current 23 A
Thermal protection adjustment range 17…23 A IEC 60947-2
Magnetic tripping current 341 A
[Ith] conventional free air thermal current 23 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
Product Weight 0.57 lb(US) (0.26 kg)
color Dark grey
GV2ME083 Schneider Electric
Schneider GV2ME083 Schneider Electric
Sale price €108,95
In stock, 11 units

Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, spring terminals

GV2ME32 Schneider Electric
Schneider GV2ME32 Schneider Electric
Sale price €116,95
In stock, 11 units

The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 24 ampere to 32 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2ME
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 15 kW 400/415 V AC 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
22 kW 690 V AC 50/60 Hz
Breaking capacity 50 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
10 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
6 kA Icu 440 V AC 50/60 Hz IEC 60947-2
4 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
50 % 400/415 V AC 50/60 Hz IEC 60947-2
50 % 440 V AC 50/60 Hz IEC 60947-2
75 % 500 V AC 50/60 Hz IEC 60947-2
75 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Push-button
Line Rated Current 32 A
Thermal protection adjustment range 24…32 A IEC 60947-2
Magnetic tripping current 537.6 A
[Ith] conventional free air thermal current 32 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
Product Weight 0.57 lb(US) (0.26 kg)
color Dark grey
GV2ME04 Schneider Electric
Schneider GV2ME04 Schneider Electric
Sale price €97,95
Only 10 units left

Motor circuit breaker, TeSys GV2, 3P, 0.4-0.63 A, thermal magnetic, screw clamp terminals

GV2L16 Schneider Electric
Schneider GV2L16 Schneider Electric
Sale price €122,95
Only 7 units left

Motor circuit breaker, TeSys GV2, 3P, 14 A, magnetic, rotary handle, screw clamp terminals

GV4P115N Schneider Electric
Schneider GV4P115N Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic, Everlink terminals

Schneider New Stock Image
Schneider LRN07N Schneider
Sale price €76,95
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2-ME16C Schneider
Schneider GV2-ME16C Schneider
Sale price €84,95
Only 9 units left

Motor Circuit Breaker GV2ME16C 9-14A Push Button 3P Thermal Magnetic Type 1Pcs

3RU2936-3AA01 Siemens
Siemens 3RU2936-3AA01 Siemens
Sale price €62,95
Only 7 units left
Product
Article Number (Market Facing Number) 3RU29363AA01 | 3RU29363AA01
Product Description stand-alone assembly support for 3RU21/3RB30/3RB31/3RR2 Size S2 Stand-alone installation Main circuit: Screw
Product family Accessories
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209947054
UPC 887621919849
Commodity Code 85369095
LKZ_FDB/ CatalogID CC-IC10
Product Group 5349
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 0.395 lb
Package size unit of measure in
Packaging Quantity 1
GV2APN01 Schneider Electric
Schneider GV2APN01 Schneider Electric
Sale price €84,95
Only 7 units left

Extended rotary handle kit, TeSys GV2, IP54, black handle, with trip indication, for GV2L-GV2P

GV3P13 Schneider Electric
Schneider GV3P13 Schneider Electric
Sale price €130,95
Only 8 units left

GV3P13 is a TeSys GV motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 5.5kW@400V and high breaking capacity Icu 100kA. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. GV3P13 is a TeSys GV motor circuit breaker from Schneider Electric designed for motor applications 5.5kW@400V. It fulfills a thermal-magnetic protection with a thermal setting range 9-13A, magnetic tripping at 14xIn and high breaking capacity Icu 100kA@400V. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. Compact, 55mm wide, for DIN-rail and panel mounting. Manual control with rotary knob for Start / Stop, padlockable. Possible mounting of auxiliary contacts front or side mounted (GVAE, GVAN, GVAD) for status and tripping signaling. For large industrial or building LV distribution networks thanks to a high 100kA breaking capacity. Power connections with EverLink BTR screw connectors providing constant tightening pressure. Can be associated with undervoltage or shunt tripping units (GVAU, GVAS) and power distribution busbars (GV3G).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or Component Type Motor circuit breaker
Device short name GV3P
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 5.5 kW 400/415 V AC 50/60 Hz
7.5 kW 500 V AC 50/60 Hz
11 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
12 kA Icu 500 V AC 50/60 Hz IEC 60947-2
6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
50 % 500 V AC 50/60 Hz IEC 60947-2
50 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Rotary handle
Line Rated Current 13 A
Thermal protection adjustment range 9…13 A IEC 60947-2
Magnetic tripping current 182 A
[Ith] conventional free air thermal current 13 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles AC-3 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Tightening torque 44.3 lbf.in (5 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 2.2 in (55 mm)
Height 5.2 in (132 mm)
Depth 5.4 in (136 mm)
Product Weight 2.12 lb(US) (0.96 kg)
color Dark grey
Schneider New Stock Image
Schneider GV3ME80 Schneider
Sale price €162,95
Only 7 units left

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or Component Type Motor circuit breaker
Device short name GV3ME
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 37 kW 400/415 V AC 50/60 Hz
45 kW 500 V AC 50/60 Hz
55 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
10 kA Icu 440 V AC 50/60 Hz IEC 60947-2
4 kA Icu 500 V AC 50/60 Hz IEC 60947-2
2 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
50 % 400/415 V AC 50/60 Hz IEC 60947-2
60 % 440 V AC 50/60 Hz IEC 60947-2
100 % 500 V AC 50/60 Hz IEC 60947-2
100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Push-button
Line Rated Current 80 A
Thermal protection adjustment range 56…80 A IEC 60947-2
Magnetic tripping current 1040 A
[Ith] conventional free air thermal current 80 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 30000 cycles
Electrical durability 30000 cycles AC-3 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Tightening torque 44.3 lbf.in (5 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 2.2 in (55 mm)
Height 5.2 in (132 mm)
Depth 5.4 in (136 mm)
Product Weight 2.12 lb(US) (0.96 kg)
color Dark grey
GV2P06 Schneider Electric
Schneider GV2P06 Schneider Electric
Sale price €114,95
Only 10 units left

Motor circuit breaker, TeSys GV2, 3P, 1-1.6 A, thermal magnetic, screw clamp terminals

Recently viewed