Overload Relays

1026 products

Showing 361 - 384 of 1026 products

Showing 361 - 384 of 1026 products
View
GVAD0110 Schneider Electric
Schneider GVAD0110 Schneider Electric
Sale price €75,95
Only 10 units left

TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NC fault signaling contact + 1NO instantaneous auxiliary contact. Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC. Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Device short name GVAD
Product or Component Type Auxiliary contact block
Product Compatibility GV2ME
GV2L
GV3P
GV2P
GV3L
GV2LE
GV2RT
Mounting Location Left side
Auxiliary contacts operation Fault signal 1 NC
Pole contact composition 1 NO + 1 NC

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 690 V IEC 60947-1
300 V UL 508
300 V CSA C22.2 No 14
[Ue] rated operational voltage 48...690 V AC
24...240 V DC
[Ith] conventional free air thermal current 6 A
2.5 A for fault signalling
Mechanical durability 100000 cycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Protection type GB2CB... circuit breaker
GG fuse 10 A
Rated operational power in VA 300 VA 48 V AC-15 100000 cycles
414 VA 690 V AC-15 100000 cycles
500 VA 110…127 V AC-15 100000 cycles
500 VA 500 V AC-15 100000 cycles
650 VA 440 V AC-15 100000 cycles
720 VA 230…240 V AC-15 100000 cycles
850 VA 380…415 V AC-15 100000 cycles
36 VA 24 V AC-14 1000 cycles
48 VA 48 V AC-14 1000 cycles
72 VA 110…127 V AC-14 1000 cycles
Rated operational power in W 120 W 240 V DC-13 100000 cycles
140 W 110 V DC-13 100000 cycles
140 W 24 V DC-13 100000 cycles
180 W 60 V DC-13 100000 cycles
240 W 48 V DC-13 100000 cycles
15 W 48 V DC-13 1000 cycles
24 W 24 V DC-13 1000 cycles
9 W 60 V DC-13 1000 cycles
Tightening torque 12.4 lbf.in (1.4 N.m) screw clamp terminals
Height 3.5 in (89 mm)
Width 0.4 in (9.3 mm)
Depth 2.6 in (66 mm)
Product Weight 0.121 lb(US) (0.055 kg)
color Dark grey
GV4LE12N Schneider Electric
Schneider GV4LE12N Schneider Electric
Sale price €326,95
Only 1 unit left

Motor circuit breaker, TeSys GV4, 3P, 12.5 A, Icu 50 kA, magnetic, EverLink terminals

Schneider New Stock Image
Schneider GV2-P16 Schneider
Sale price €122,95
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GVAX385 Schneider Electric
Schneider GVAX385 Schneider Electric
Sale price€0,00
Sold Out

Undervoltage release (MN), TeSys GV2, 380-400V AC 50Hz / 440V AC 60Hz, safety device for use with GV2ME

GV7AS387 Schneider Electric
Schneider GV7AS387 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV electrical trip unit, MX shunt trip, 380-440V AC 50/60Hz, for motor circuit breakers GV5, GV6, GV7. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be plugged inside the circuit breaker, connection by screw terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Main

Characteristic Value(s)
Range TeSys
Product or Component Type Shunt trip
Device short name GV7AS
Device Application Control
Range compatibility TeSys TeSys GV5
TeSys TeSys GV6
TeSys TeSys GV7

Complementary

Characteristic Value(s)
[Uc] control circuit voltage 380...440 V AC 50/60 Hz
Control circuit voltage limits 0.7...1.1 Un
[Ui] rated insulation voltage 690 V AC IEC 60947-1
600 V AC UL 508
600 V AC CSA C22.2 No 14
Threshold tripping voltage 0.2...0.75 Ue
Inrush power in VA 10 VA AC
Hold-in Power Consumption in VA 5 VA AC
Operating time < 50 ms IEC 60947-1
On-load factor 100 %
Connections - terminals screw clamp terminals 1 0.002 in² (1 mm²)flexible with cable end
screw clamp terminals 1 0.002 in² (1.5 mm²)flexible without cable end
screw clamp terminals 1 0.002 in² (1.5 mm²)solid
Tightening torque 1.2 N.m screw clamp terminals
Product Weight 0.231 lb(US) (0.105 kg)
Quantity per Set Set of 10
GV2RT14 Schneider Electric
Schneider GV2RT14 Schneider Electric
Sale price €279,95
Only 1 unit left

TeSys GV motor circuit breaker, 3 poles (3P), 10A/690V, for high starting current peak motor applications 3-4kW@400V. It provides a thermal-magnetic protection with a thermal setting range 6-10A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. It can be used for protection of 3-phase transformer applications. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2RT
Device Application Motor protection
Transformer
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 1.5 kW 220/230 V AC 50/60 Hz motor protection high peak current
2.2 kW 220/230 V AC 50/60 Hz motor protection high peak current
3 kW 400/415 V AC 50/60 Hz motor protection high peak current
4 kW 400/415 V AC 50/60 Hz motor protection high peak current
4 kW 440 V AC 50/60 Hz motor protection high peak current
4 kW 500 V AC 50/60 Hz motor protection high peak current
5.5 kW 500 V AC 50/60 Hz motor protection high peak current
5.5 kW 690 V AC 50/60 Hz motor protection high peak current
7.5 kW 690 V AC 50/60 Hz motor protection high peak current
2.5 kW 230/240 V AC 50/60 Hz transformer protection
4 kW 400/415 V AC 50/60 Hz transformer protection
5 kW 400/415 V AC 50/60 Hz transformer protection
5 kW 440 V AC 50/60 Hz transformer protection
5 kW 500 V AC 50/60 Hz transformer protection
6.3 kW 500 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
15 kA Icu 440 V AC 50/60 Hz IEC 60947-2
10 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Control Type Toggle
Line Rated Current 10 A
Thermal protection adjustment range 6…10 A IEC 60947-2
Magnetic tripping current 200 A
[Ith] conventional free air thermal current 10 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.09 in (78.5 mm)
GVAS055 Schneider Electric
Schneider GVAS055 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV electrical trip, MX shunt release, 48V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC),

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Product or component type Shunt trip release
Device short name GVAS

Complementary

Characteristic Value(s)
Range compatibility TeSys GV2ME
TeSys GV2LE
TeSys GV2L
TeSys GV2P
TeSys GV3L
TeSys GV3P
TeSys Deca
[Uc] control circuit voltage 48 V AC 50 Hz
Control circuit voltage limits 0.7...1.1 Un
[Ui] rated insulation voltage 690 V AC conforming to IEC 60947-1
600 V AC conforming to UL 60947-4-1
600 V AC conforming to CSA C22.2 No 60947-4-1
Threshold tripping voltage 0.75...0.2 Un
Inrush power in VA 14 VA AC
Inrush power in W 10.5 W
Hold-in power consumption in VA 5 VA AC
Hold-in power consumption in W 1.6 W
Operating time 10...15 ms conforming to IEC 60947-1
On-load factor 100 %
Connections - terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²solid
Screw clamp terminals 2 cable(s) 1…2.5 mm²solid
Screw clamp terminals 1 cable(s) 0.75…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.75…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.75…1.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.75…1.5 mm²flexible with cable end
Tightening torque < 1.4 N.m on screw clamp terminals
Mechanical durability 10000 cycles with GV3P and GV3L
30000 cycles with GV2ME and GV2P
Quantity per set Set of 10
Height 89 mm
Width 18 mm
Depth 66 mm
Product weight 0.105 kg
Colour Dark grey
GV4L12N Schneider Electric
Schneider GV4L12N Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 12.5A/690V, for protection of 3-phase motors 3-5.5kW@400V. It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range of product TeSys GV4
Range TeSys Deca
Device short name GV4L
product name TeSys GV4
Product or component type Motor circuit breaker
Device application Motor protection
Trip unit technology Magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Operating position Any position
Motor power kW 3 kW at 400...415 V AC 50/60 Hz
3 kW at 500 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
5.5 kW at 660...690 V AC 50/60 Hz
7.5 kW at 660...690 V AC 50/60 Hz
4 kW at 400...415 V AC 50/60 Hz
5.5 kW at 400...415 V AC 50/60 Hz
5.5 kW at 500 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
9 kW at 660...690 V AC 50/60 Hz
11 kW at 660...690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
control type Rotary handle
[In] rated current 12.5 A
Magnetic tripping current 75…175 A
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current 115 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
Power dissipation per pole 6.1 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles for AC-3 at 440 V In/2
40000 cycles for AC-3 at 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous conforming to IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid
EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid
EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
Tightening torque 9 N.m for cable 16…95 mm²
5 N.m for cable 1.5…10 mm²
Mechanical robustness Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
Height 155 mm
Width 81 mm
Depth 165 mm
Product weight 1.65 kg
Colour Grey (RAL 7016)
Suitability for isolation Yes conforming to IEC 60947-1
GV4PE03N Schneider Electric
Schneider GV4PE03N Schneider Electric
Sale price€0,00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic, Everlink terminals

Schneider New Stock Image
Schneider LRD22C Schneider
Sale price €79,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GVAN203 Schneider Electric
Schneider GVAN203 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV2 & GV3 - auxiliary contact block - 2 NO

Schneider Stock Image
Schneider LR-D484C Schneider
Sale price€0,00
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

GV2L04 Schneider Electric
Schneider GV2L04 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for 3-phase motor applications 0.12-0.18kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD04 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2L
Device Application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 0.12 kW 400/415 V AC 50/60 Hz
0.18 kW 400/415 V AC 50/60 Hz
0.37 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
100 kA Icu 440 V AC 50/60 Hz IEC 60947-2
100 kA Icu 500 V AC 50/60 Hz IEC 60947-2
100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
100 % 500 V AC 50/60 Hz IEC 60947-2
100 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Rotary handle
Line Rated Current 0.63 A
Magnetic tripping current 9.3 A
[Ith] conventional free air thermal current 0.63 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 1.8 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit screw clamp terminal 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit screw clamp terminal 2 0.002…0.009 in² (1.5…6 mm²)flexible without cable end
Power circuit screw clamp terminal 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Tightening torque 15.05 lbf.in (1.7 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 2 x M4 screws)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 3.5 in (89 mm)
Depth 3.8 in (97 mm)
Product Weight 0.73 lb(US) (0.33 kg)
color Dark grey
GV4PE115N6 Schneider Electric
Schneider GV4PE115N6 Schneider Electric
Sale price €1.021,95
Only 1 unit left

TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PE
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Thermal-magnetic
Electronic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 37 kW 400...415 V AC 50/60 Hz
45 kW 400...415 V AC 50/60 Hz
55 kW 400...415 V AC 50/60 Hz
45 kW 500 V AC 50/60 Hz
55 kW 500 V AC 50/60 Hz
75 kW 500 V AC 50/60 Hz
75 kW 660...690 V AC 50/60 Hz
90 kW 660...690 V AC 50/60 Hz
110 kW 660...690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
15 kA Icu 525 V AC 50/60 Hz IEC 60947-2
65 kA 208Y/120 V AC 50/60 Hz UL 60947
65 kA 240 V AC 50/60 Hz UL 60947
35 kA 480Y/277 V AC 50/60 Hz UL 60947
8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 115 A
Magnetic tripping current 1955 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 10000 cycles AC-3 440 V In/2
5000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connection pitch 1.06 in (27 mm) without spreaders
1.4 in (35 mm) with spreaders
Connections - terminals Lugs-ring terminals
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
GV2ME223 Schneider Electric
Schneider GV2ME223 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a thermal-magnetic protection with a thermal setting range 20-25A, magnetic tripping at 13xIn, high breaking capacity Icu 15kA@400V. Connection by spring terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2ME
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 11 kW 400/415 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
Breaking capacity 50 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
6 kA Icu 440 V AC 50/60 Hz IEC 60947-2
4 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
40 % 400/415 V AC 50/60 Hz IEC 60947-2
50 % 440 V AC 50/60 Hz IEC 60947-2
75 % 500 V AC 50/60 Hz IEC 60947-2
75 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Push-button
Line Rated Current 25 A
Thermal protection adjustment range 20…25 A IEC 60947-2
Magnetic tripping current 388.3 A
[Ith] conventional free air thermal current 25 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit spring terminals 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit spring terminals 2 0.002…0.006 in² (1.5…4 mm²)flexible without cable end
Power circuit spring terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 4.0 in (101 mm)
Depth 3.09 in (78.5 mm)
Product Weight 0.62 lb(US) (0.28 kg)
color Dark grey
GV4PE50S Schneider Electric
Schneider GV4PE50S Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PE
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Electronic
Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 11 kW 400...415 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 660...690 V AC 50/60 Hz
15 kW 400...415 V AC 50/60 Hz
18.5 kW 400...415 V AC 50/60 Hz
22 kW 400...415 V AC 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
22 kW 500 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
22 kW 660...690 V AC 50/60 Hz
30 kW 660...690 V AC 50/60 Hz
37 kW 660...690 V AC 50/60 Hz
45 kW 660...690 V AC 50/60 Hz
Breaking capacity 120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
70 kA Icu 440 V AC 50/60 Hz IEC 60947-2
30 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA Icu 525 V AC 50/60 Hz IEC 60947-2
100 kA 208Y/120 V AC 50/60 Hz UL 60947
100 kA 240 V AC 50/60 Hz UL 60947
65 kA 480Y/277 V AC 50/60 Hz UL 60947
10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 50 A
Magnetic tripping current 850 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 20000 cycles AC-3 440 V In/2
10000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors top) 1 0.002…0.1 in² (1.5…70 mm²) - solid
EverLink BTR screw connectors top) 1 0.002…0.08 in² (1.5…50 mm²) - flexible
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…95 mm²) - solid
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…70 mm²) - flexible
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
GV4PE25N Schneider Electric
Schneider GV4PE25N Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 10-25A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PE
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Electronic
Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 7.5 kW 660...690 V AC 50/60 Hz
5.5 kW 400...415 V AC 50/60 Hz
7.5 kW 500 V AC 50/60 Hz
9 kW 660...690 V AC 50/60 Hz
11 kW 660...690 V AC 50/60 Hz
7.5 kW 400...415 V AC 50/60 Hz
9 kW 400...415 V AC 50/60 Hz
11 kW 400...415 V AC 50/60 Hz
9 kW 500 V AC 50/60 Hz
11 kW 500 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
15 kW 660...690 V AC 50/60 Hz
18.5 kW 660...690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
15 kA Icu 525 V AC 50/60 Hz IEC 60947-2
65 kA 208Y/120 V AC 50/60 Hz UL 60947
65 kA 240 V AC 50/60 Hz UL 60947
35 kA 480Y/277 V AC 50/60 Hz UL 60947
8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 25 A
Magnetic tripping current 425 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 40000 cycles AC-3 440 V In/2
20000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors top) 1 0.002…0.1 in² (1.5…70 mm²) - solid
EverLink BTR screw connectors top) 1 0.002…0.08 in² (1.5…50 mm²) - flexible
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…95 mm²) - solid
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…70 mm²) - flexible
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
GV7AS107 Schneider Electric
Schneider GV7AS107 Schneider Electric
Sale price€0,00
Sold Out

Voltage release, TeSys GV5 GV6 GV7, MX shunt trip, 110-130V AC 50/60Hz

Schneider New Stock Image
Schneider LRD082 Schneider
Sale price €84,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV2ME163 Schneider Electric
Schneider GV2ME163 Schneider Electric
Sale price€0,00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for 3-phase motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a thermal setting range 9-14A, magnetic tripping at 13xIn, high breaking capacity Icu 15kA@400V. Connection by spring terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or Component Type Motor circuit breaker
Device short name GV2ME
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
AC-3e IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 5.5 kW 400/415 V AC 50/60 Hz
7.5 kW 500 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
8 kA Icu 440 V AC 50/60 Hz IEC 60947-2
6 kA Icu 500 V AC 50/60 Hz IEC 60947-2
3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
50 % 400/415 V AC 50/60 Hz IEC 60947-2
50 % 440 V AC 50/60 Hz IEC 60947-2
75 % 500 V AC 50/60 Hz IEC 60947-2
75 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Push-button
Line Rated Current 14 A
Thermal protection adjustment range 9…14 A IEC 60947-2
Magnetic tripping current 253.4 A
[Ith] conventional free air thermal current 14 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles AC-3 415 V In
100000 cycles AC-3e 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Connections - terminals Power circuit spring terminals 2 0.002…0.009 in² (1…6 mm²)solid
Power circuit spring terminals 2 0.002…0.006 in² (1.5…4 mm²)flexible without cable end
Power circuit spring terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with adaptor plate)
Mounting position Horizontal
Vertical
Width 1.8 in (45 mm)
Height 4.0 in (101 mm)
Depth 3.09 in (78.5 mm)
Product Weight 0.62 lb(US) (0.28 kg)
color Dark grey
GVAPBPHP Schneider Electric
Schneider GVAPBPHP Schneider Electric
Sale price€0,00
Sold Out

Main

Characteristic Value(s)
Range TeSys
Product or component type Protection cover
Product destination Rotary handle
Device short name GVAP
Accessory / separate part category Control accessory

Complementary

Characteristic Value(s)
Product compatibility GVAPB54
GVAPB65
GV2APN01
GV2APN03
GV2AP03
GV3APN01
GV3APN03
GV4APN01
LU9APN21
LV426932
LV426935
LV426997
Quantity per set Set of 1
Height 60 mm
Width 60 mm
Depth 38 mm
Product weight 16 g
Colour Black
GV3P25 Schneider Electric
Schneider GV3P25 Schneider Electric
Sale price €129,95
Only 10 units left

GV3P25 is a TeSys GV motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 11kW@400V and high breaking capacity Icu 100kA. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. GV3P25 is a TeSys GV motor circuit breaker from Schneider Electric designed for motor applications 11kW@400V. It fulfills a thermal-magnetic protection with a thermal setting range 17-25A, magnetic tripping at 14xIn and high breaking capacity Icu 100kA@400V. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V. Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. Compact, 55mm wide, for DIN-rail and panel mounting. Manual control with rotary knob for Start / Stop, padlockable. Possible mounting of auxiliary contacts front or side mounted (GVAE, GVAN, GVAD) for status and tripping signaling. For large industrial or building LV distribution networks thanks to a high 100kA breaking capacity. Power connections with EverLink BTR screw connectors providing constant tightening pressure. Can be associated with undervoltage or shunt tripping units (GVAU, GVAS) and power distribution busbars (GV3G).

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or Component Type Motor circuit breaker
Device short name GV3P
Device Application Motor protection
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Network frequency 50/60 Hz IEC 60947-2
Motor power kW 11 kW 400/415 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
12 kA Icu 500 V AC 50/60 Hz IEC 60947-2
6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
50 % 500 V AC 50/60 Hz IEC 60947-2
50 % 690 V AC 50/60 Hz IEC 60947-2
Control Type Rotary handle
Line Rated Current 25 A
Thermal protection adjustment range 17…25 A IEC 60947-2
Magnetic tripping current 350 A
[Ith] conventional free air thermal current 25 A IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-2
Phase failure sensitivity Yes IEC 60947-4-1
Suitability for isolation Yes IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles AC-3 415 V In
Rated duty Uninterrupted IEC 60947-4-1
Tightening torque 44.3 lbf.in (5 N.m) screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 2.2 in (55 mm)
Height 5.2 in (132 mm)
Depth 5.4 in (136 mm)
Product Weight 2.12 lb(US) (0.96 kg)
color Dark grey
3RU2126-4AJ0 Siemens
Siemens 3RU2126-4AJ0 Siemens
Sale price€0,00
Sold Out
Product
Article Number (Market Facing Number) 3RU21264AJ0 | 3RU21264AJ0
Product Description Overload relay 11...16 A Thermal For motor protection Size S0, Class 10 Contactor mounting Main circuit: Ring cable lug Auxiliary circuit: ring cable lug Manual-Automatic-Reset
Product family Not available
Product Lifecycle (PLM) PM410:Product cancellation
Additional Product Information
EAN 4011209781412
UPC 662643919219
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5346
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 0.403 lb
Package size unit of measure Inch
Packaging Quantity 1
3RU2136-4JB0 Siemens
Siemens 3RU2136-4JB0 Siemens
Sale price €120,95
Only 8 units left
Product
Article Number (Market Facing Number) 3RU21364JB0 | 3RU21364JB0
Product Description Overload relay 54...65 A Thermal For motor protection Size S2, Class 10 Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-Automatic-Reset
Product family SIRIUS 3RU2 thermal overload relays
Product Lifecycle (PLM) PM300:Active Product
Additional Product Information
EAN 4011209916777
UPC 887621919689
Commodity Code 85364900
LKZ_FDB/ CatalogID CC-IC10
Product Group 5346
Group Code R711
Country of origin Germany
SCIP number Not available
Delivery information
Net Weight (lb) 0.758 lb
Package size unit of measure Inch
Packaging Quantity 1

Recently viewed