Specifications
Model |
SV2-M020AK |
|||
General specifications |
Applicable servo amplifier |
SV2-020L2 |
||
Rated output |
200 W |
|||
Rated torque |
0.637 N·m *1 |
|||
Instant maximum torque |
2.23 N·m |
|||
Rated current |
1.6 Arms |
|||
Instant maximum current |
5.8 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.444 N·m/Arms |
|||
Rotor moment of inertia |
0.263 ×10-4kg·m2 |
|||
Rated power rating |
15.4 kW/s |
|||
Rated angle acceleration |
24200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
15 × |
|||
Approx. weight |
0.8 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||


Specifications
Model |
FU-95S |
|||
Type |
Liquid-level detection fiber unit |
|||
Detecting method |
Pipe mounting type |
|||
No. of beam axes |
16 mm0.63" |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Minimum bend radius |
R5 mm0.197" |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Accessories |
Binding band × 2, nonslip rubber × 2, Fiber cutter × 1 |
|||
Weight |
Approx. 23 g |
|||


Specifications
Model |
DX-A400 |
|||
Controller |
CPU |
ARM® Penta Core |
||
OS |
Android™14 |
|||
Main Memory |
RAM/ROM |
4 GB RAM, 64 GB ROM |
||
Display |
LCD |
4.0-inch, 480 × 800 |
||
Operation Status LED |
3-color LED |
|||
Operations |
Hard Keys |
Trigger key × 2, Volume up/down keys, Power key, Front Fn key × 3 |
||
Touch Panel |
Electrostatic capacitance method (Tempered glass) |
|||
Scanner |
Reading Light Source |
High-intensity white LED |
||
Pointer Light Source |
Visible semiconductor laser (655 nm), Output: 390 μW, Class 1 laser product (JIS C 6802) (IEC 60825-1) |
|||
Minimum Resolution |
2D code: 0.169 mm 0.0067", Barcode: 0.076 mm 0.0030" |
|||
Field Range |
186 × 114 mm 7.32" × 4.49" (Reading distance: 200 mm 7.87") |
|||
Supported Codes |
UPC/EAN/JAN (add-on code support), CODE128, GS1-128, CODE39, Codabar (NW-7), CODE93, ITF, COOP 2of5, Industrial 2of5, |
|||
Communication |
Wireless LAN |
IEEE 802.11 a/b/g/n/ac |
||
Bluetooth |
Bluetooth Ver. 5.1 BR/EDR/LE |
|||
WWAN |
4G LTE/3G, SIM unlocked, Nano SIM slot × 1 |
|||
GNSS |
GPS, A-GPS, GLONASS, Beidou |
|||
NFC |
ISO 14443 Type A, B, FeliCa, ISO 15693 |
|||
Supported Media |
microSD/SDHC/SDXC UHS-I |
|||
Power Source |
Main Battery |
Dedicated lithium-ion battery pack |
||
Backup Battery |
Built-in lithium secondary battery: Approx. 1 month*1 |
|||
Other |
Microphone |
2 (noise-canceling) |
||
Speaker |
Speaker × 1, Receiver × 1 |
|||
Vibration |
Available |
|||
Camera |
Rear Camera: 8 MP-AF, Front Camera: 5 MP |
|||
Sensor |
Accelerometer, Gyroscope, Digital compass, Ambient light, Proximity, Temperature and humidity, Barometric pressure |
|||
Environmental resistance |
Ambient temperature |
-20 to +50°C -4 to +122°F, Charging: 0 to +40°C 32 to 104°F*2 |
||
Relative humidity |
20 to 85% RH (No condensation) |
|||
Storage temperature |
-20 to +60°C -4 to +140°F (No freezing) |
|||
Storage relative humidity |
20 to 85% RH (No condensation) |
|||
Dimensions |
143.5 × 73.7 × 31.8 mm 5.65" × 2.90" × 1.25" |
|||
Weight |
Approx. 165 g 5.82 oz |
|||
*1 This indicates the case when the main battery is not attached or the battery has no charge. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.



Specifications
Model |
KV-NC4AD |
|||
Conversion speed |
80 μs/channel*1 |
|||
Conversion |
A/D conversion |
|||
Points |
4 (single end) |
|||
Range/resolution |
Voltage |
-10 V to +10 V |
1/8000 2.5 mV |
|
0 to 10 V |
1/4000 2.5 mV |
|||
0 to 5 V |
1/4000 1.25 mV |
|||
1 to 5 V |
1/3200 1.25 mV |
|||
Current |
0 to 20 mA |
1/4000 5 μA |
||
4 to 20 mA |
1/3200 5 μA |
|||
Conversion precision |
Voltage |
Without temperature |
±0.3% of F.S. (at 25°C ±5°C 77°F ±9°F) |
|
With temperature |
±0.3% of F.S. (at 0 to 55°C 32 to 131°F) |
|||
Current |
Without temperature |
±0.4% of F.S. (at 25°C ±5°C 77°F ±9°F) |
||
With temperature |
±0.4% of F.S. (at 0 to 55°C 32 to 131°F) |
|||
Input resistance |
Voltage |
5 MΩ |
||
Current |
250 Ω |
|||
Absolute maximum input |
Voltage |
±15 V |
||
Current |
±30 mA |
|||
Isolation method |
Between analog input |
Isolated (photocoupler, transformer) |
||
Between analogu input channels |
No isolation |
|||
Minimum load resistance |
Voltage |
− |
||
Maximum load resistance |
Current |
|||
Special functions |
Input range switching, |
|||
*1 When the temperature fluctuation compensation is used, the temperature fluctuation compensation time of 80 μs will be added regardless of the number of channels being used. | ||||



Specifications
Model |
GL-R111F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
44.09" 1120mm |
|||
No. of beam |
111 |
|||
Detection height |
43.31" 1100mm |
|||
Protection height |
44.25" 1124mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
16.4 |
|
OFF→ON |
63.4*2 |
|||
All blocked→ON |
102.4*3 |
|||
Optical synchronization system |
ON→OFF |
24.6 |
||
OFF→ON |
75.7*2 |
|||
All blocked→ON |
135.2*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
74 |
||
Receiver |
85 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1600 g |
||
Receiver | ||||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
OP-88762 |
|||
Type |
FD-R connection cable (with MP-FEN1 connected) |
|||
Specifications |
M12 male 5-pin - M12 female 4-pin |
|||
Length |
2 m 6.6' |
|||
Weight |
Approx. 85 g 2.99 oz |
|||

Specifications
Model |
ER-U30PC *1 |
|||
Type |
Ultra-long distance unshielded type Screw type M30 Connector (M12 4-pin) PNP output |
|||
Power supply cable length |
― *2 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching |
||
Detecting distance |
With default settings (Mode 1) |
52 mm 2.05" ±10% *3 |
||
With distance switching (Mode 2) |
32 mm 1.26" ±10% *3 |
|||
Response frequency |
With default settings (Mode 1) |
10 Hz *4 *5 |
||
With distance switching (Mode 2) |
20 Hz *4 *5 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *6 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
156 × 156 mm 6.14" × 6.14" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) *8 |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *9 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 150 g 5.30 oz |
|||
*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps). | ||||

Specifications
Model |
GS-51P10 |
|||
Lock type |
Power-to-release type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
220 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 770 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
PX-10C |
|||
Type |
Connector type |
|||
Output |
NPN |
|||
Response time |
500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||
Output selection |
LIGHT-ON/DARK-ON |
|||
Indicator lamp |
- Operation indicator:Red LED x 2, DSC orange LED x 1 |
|||
Detection mode |
Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor] |
|||
Shift function |
Variable between –1999 and 9999 |
|||
Timer function |
Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot |
|||
Control output |
NPN open-collector 40 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max. |
|||
External input |
― |
|||
Interference prevention |
Up to 4 units (in all power modes)*1 |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*2 |
||
Power consumption |
Standard mode:50 mA max. at 24 V/55 mA max. at 12 V |
|||
Environmental resistance |
Enclosure rating |
IEC: IP67/JEM: IP67/NEMA: 4X |
||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*3 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Case material |
Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR |
|||
Weight |
Approx. 50 g |
|||
*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected | ||||