Machine Vision Systems

5768 products

Showing 961 - 984 of 5768 products

Showing 961 - 984 of 5768 products
View
keyence Stock Image
Keyence CA-DZR5 Keyence
Sale price€0,00
Sold Out

Specifications

Model

CA-DZR5

LED color

red

Power consumption

2.5 W

Weight

Approx 240 g

keyence Stock Image
Keyence AP-41M Keyence
Sale price€0,00
Sold Out

Specifications

Model

AP-41M

Application

Gauge pressure

Type

Negative pressure

Rated pressure

0 to -101.3 kPa

Fluid type

Air, non-corrosive gasses

Temperature characteristics

±2 % of F.S. (When the temperature varies from 25 °C 77 °F)

Pressure port

M3 male threaded

Environmental resistance

Pressure resistance

500 kPa

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 4 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 10 times in each of X, Y and Z directions, total of 60 times

Material

Case: PBT, Screw: SUS303, Cable: PVC

Weight

Approx. 68 g (including cable)

keyence Stock Image
Keyence CA-HL08MX Keyence
Sale price €2.836,95
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence EM-014A Keyence
Sale price€0,00
Sold Out

Specifications

Model

EM-014A*1

Type

Shielded

Shape

M14 Threaded

Detecting distance

4.0 mm 0.16" ±10%

Detectable object

Ferrous metals (see Characteristics for non-ferrous metals)

Standard target
(iron, t=1 mm 0.04")

15 x 15 mm 0.59" x 0.59"

Hysteresis

10% max. of detecting distance

Response frequency

1.2 kHz

Operation mode

N.O.

Temperature characteristics

±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F

Display indicator

Red LED

Control output

NPN: 200 mA (40 V) max., Residual voltage: 1 V max.

Housing

Cr-plated brass

Rating

Power voltage

10.8 to 30 VDC, Ripple (P-P) 10 % or less*2

Current consumption

12 mA or less

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +80 °C -13 to 176 °F (No freezing)

Relative humidity

35 to 95 % RH (No condensation)

Weight

Approx. 60 g (including nuts and 2-m 6.6' cable)

*1 The alternate-frequency type of EM-014
*2 Make sure that the power voltage stays within 10.8 V to 30 V even if it is affected by ripple effects.

keyence Stock Image
Keyence GL-VCC5 Keyence
Sale price€0,00
Sold Out

Specifications

Model

GL-VCC5

Type

Extension cable

Number included

1 pc.

Cable end

Female side: M12 connector 5 pin
Male side: M12 connector 5 pin

Number of cores

5

Length

5 m 16.4'

Material

connector: PVC/Nickel-plated brass
cable: PVC

Weight

300 g

keyence Stock Image
Keyence ER-N12 Keyence
Sale price€0,00
Sold Out

Specifications

Model

ER-N12

Type

Separate amplifier Amplifier unit Expansion unit (cable type)

No. of control outputs

2

No. of external inputs

1

Temperature characteristics

±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *1

Response time

150 μs *2/ 300 μs *2/ 1 ms / 4 ms / 16 ms / 64 ms (switchable)

Network compatibility

NU Series

Function

Operation mode

Normal / Magnetic metal / Non-magnetic metal / Hybrid

Timer function

Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot

I/O

Control output

Open-collector, 30 VDC or less, PNP/NPN switchable
When used as a solitary unit: 100 mA or less for 1 output; 100 mA or less in total for 2 outputs / When used as an expansion unit: 50 mA or less in total for 2 outputs
Residual voltage: 1.7 V or less (Output current: 10 mA or less) / 2.4 V or less (Output current: 10 to 100 mA)

External input

Tuning / Detection stop / Zero shift / Hold value reset (switchable)
Short-circuit current: 1.5 mA or less; Input time: 3 ms or more ON, 20 ms or more OFF (When tuning is selected: 25 ms or more ON, 25 ms or more OFF)

Additional expansion units

Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

No. of mutual interference prevention units

OFF / 4 units / 8 units (selectable) *3

Power supply

Power voltage

18 to 30 VDC *4 (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1110 mW or less (47 mA or less at 24 V, 62 mA or less at 18 V)

Environmental resistance

Ambient temperature

Operation: -25 to +55°C -13°F to +131°F *5, Storage: -30 to 70°C -22°F to +158°F (no freezing)

Relative humidity

Operation/storage: Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions

Case material

Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass

Accessories

Instruction manual

Weight

Approx. 90 g 3.18 oz

*1 The value when the operation mode is set to “Normal”, using the 2-point adjust function at a distance of 25% of the stable detection range with no detectable object, and a standard detectable object is placed at a distance of 50% of the stable detection range.
*2 150 μs and 300 μs are selectable only when the operation mode is set to “Normal”.
*3 The response time changes as follows when 4 or 8 units are selected as the number of interference prevention units. When set to 4 units: 5 ms / 10 ms / 40 ms / 170 ms / 700 ms (switchable), When set to 8 units: 10 ms / 20 ms / 70 ms / 300 ms / 1.2 s (switchable)
*4 Use a power voltage of 20 V or more when connecting 4 or more expansion units.
*5 When 1 or 2 units are added: -25 to +55°C -13°F to +131°F; when 3 to 10 units are added: -25 to +50°C -13°F to +122°F; when 11 to 16 units are added: -25 to +45°C -13°F to +113°F. When using two outputs, one unit is counted as two units. The prescribed values for the operating ambient temperature assume the sensor amplifier is mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.

keyence Stock Image
Keyence FL-CP160 Keyence
Sale price€0,00
Sold Out

Specifications

Model

FL-CP160

Total length (at 25 °C)

1613

Measurement range (dead zone excluded)

1,557 (1,537)*1

Weight

Approx. 880 g

*1 Values for water. For oil

EH-108 Keyence
Keyence EH-108 Keyence
Sale price €127,95
In stock, 36 units

Specifications

Model

EH-108

Type

Oil-resistant, Shielded, Threaded*1

Detectable object

Ferrous metals (see Characteristics for nonferrous metals)

Standard target (iron, t=1 mm 0.04")

10 x 10 mm 0.39" x 0.39"

Stable detecting range

0 to 1.5 mm0.06"

Maximum detecting distance

2.5 mm0.10"

Hysteresis

0.07 mm0.003"

Repeatability

0.005 mm0.0002"

Temperature characteristics

±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 51 g (including nuts and 3-m 9.8' cable)

*1 Not designed for immersed use.

keyence Stock Image
Keyence OP-51464 Keyence
Sale price€0,00
Sold Out

Specifications

Model

OP-51464

Overview

Front protective cover protecting detection side of light curtain.

Applicable product

SL-V95F, SL-V48H, SL-V24L, SL-C48H, SL-C24L

Number included

1 pcs.

Length

950.3 mm 37.41"

Material

Translucent plastic: Polycarbonate (t=Approx. 1.15mm), Black plastic: ABS

Note

To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42

Keyence Stock Image
Keyence AG-410 Keyence
Sale price €1.127,95
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence LV-NH47 Keyence
Sale price €494,95
Only 1 unit left

Specifications

Model

LV-NH47

Type

Definite-reflective

FDA (CDRH) Part 1040.10

Class 1

IEC 60825-1

Light source

Visible semiconductor laser, Wavelength: 660 nm

Detecting
distance

MEGA

55 to 85 mm 2.17" to 3.35"

ULTRA

SUPER

TURBO

FINE

HSP

Environmental resistance

Ambient temperature

-10 to +55°C 14°F to 131°F (No freezing)

Relative humidity

35 to 85% RH (No condensation)

Material

Case

Glass-reinforced plastic

Lens cover

Transmitter: Glass
Receiver: Polyarylate

Weight

Approx. 70 g 2.47 oz

Keyence Stock Image
Keyence LC-2400A Keyence
Sale price €15.149,95
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence SV2-D20B Keyence
Sale price€0,00
Sold Out

Specifications

Model

SV2-D20B

Type

Motor power cable, Standard cable with electromagnetic brake

Length

20 m 65.6'

Note

for 200 W / 400 W motor

keyence Stock Image
Keyence XM-H5C Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence NR-EN16 Keyence
Sale price €2.017,95
Only 5 units left

Specifications

Model

NR-EN16 *1

Connection target devices

DL-EN1 (Connected sensor: GT2 Series, GT Series, IL Series, IG Series, IB Series, IX Series, SK Series)*2
NQ-EP4L (Connected sensor: FD-Q Series,FD-R Series, FD-X Series, FD-G Series, LR-T Series, FL Series, GP-M Series, FD-H Series, FD-EP Series, FD-EC Series, FI-1000, FI-T Series)*2;
LK-G5000 Series, CL-3000 Series, LJ-V7000 Series, LJ‑X8000 Series, LS-9000 Series;
Connection of one of the above devices per NR-EN16 allowed

Connection target device identification

Automatic identification or manual identification by specifying the IP address

Communication protocols

Ethernet TCP/UDP communication, BOOTP/DHCP client supported (compatible with the above connection target devices)

Interface

Ethernet 100Base-TX (AUTO-MDI/MDIX-compatible), 1 port*3

Number of channels

16 ch max. (varies depending on connected devices)

Collection period

Maximum sampling cycle: 1 ms (1 kHz) to 60 s
With effective rate display function for communication between connected sensors*4

Buffer memory

8M data*5

Sensor power output function

• Output from power supply output connector (4-pole terminal block) (switchable between output ON and OFF)
• Output voltage: 24 VDC ±10%
• Rated current: Max. 0.6 A (switchable between 0.3 A and 0.6 A)
• Built-in overcurrent protection function: Automatic recovery, switchable between 0.35 A (typ.) and 0.70 A (typ.) protection current
• Class 2 power supply (CSA C22.2 No. 223 / UL 1310 compliant)
• Sensor power supply not insulated from system bus

Power consumption

1.6 W or less*6

Surrounding air temperature

0 to +40°C 32°F to 104°F

Operating ambient humidity

10 to 85% RH (no condensation)

Weight

Approx. 150 g 5.30 oz (including approx. 10 g 0.35 oz for the OP-88513 (NR-EN16 power supply terminal block))

*1 For NR-EN16 units, connect the Ethernet cable directly to the target device. Operation with hubs is not guaranteed.
*2 Multiple sensors can be connected to each DL-EN1/NQ-EP4L. The number of connectable sensors depends on the DL-EN1/NQ-EP4L.
*3 Max. expansion: 18 ports (with 18 units connected, using NR-X100W), 4 ports (with 4 units connected, using NR-500). Up to 4 units can be connected for each NR-X100W and NR-XR01 group when using the NR-X100W, with up to 18 units for all groups.
*4 The effective rate may vary depending on the connected sensor and the communication conditions.
*5 Limited by the NR-X100W buffer memory when using the NR‑X100W.
*6 When using the power supply output function, the unit power consumption is calculated as follows regardless of the actual power output (load). Set to 0.3 A output = 10.0 W; Set to 0.6 A output = 20.0 W. The power supply output function can be set using a switch on the unit body.

keyence Stock Image
Keyence OP-88289 Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence KV-N16ER Keyence
Sale price €1.082,95
Only 5 units left

Specifications

Model

KV-N16ER

Expansion output unit

Output Points

16 points

External connectionmethod

Relay

External connection method

Terminal block

Rated load

250 VAC/30 VDC, 2 A

Leakage current (when output is OFF)

Residual voltage (at ON)

ON resistance

50 mΩ or less

Common method

4 points/1 common
(8 terminals) *1

Response time

OFF to ON

10 ms or less

ON to OFF

Relay life

Electrical: 100000 cycles or more (20 cycles/minute)
Mechanical: 20000000 cycles or more

Relay replacement

Impossible

Internal current consumption

100 mA or less

Weight

Approx. 260 g

*1 The KV-N16ER has two terminals for each of C0, C1, C2, and C3 respectively, which are shorted internally. (C0, C1, C2, and C3 are independent.)

Keyence Stock Image
Keyence FD-XS8 Keyence
Sale price €952,95
Only 10 units left

Specifications

Model

FD-XS8

Supported pipe materials

Metal pipes, Plastic pipes (soft/hard) *1

Supported fluids

Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1

Supported fluid temperature

0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)

Clamp set model

Plastic pipe/tube attachment

FD-XC8R1, FD-XC8R2, FD-XC8R3

Metal pipe attachment

FD-XC8M*2

Maximum rated flow rate

Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : 0 to 3000 mL/min
Outer diameter of pipe ø 8 0.31 ": 0 to 8000 mL/min

Zero cut flow rate

40 mL/min*3 (variable, default)

Display resolution

Instantaneous flow rate

0.1/1/10 mL/min (Displayed on controller)

Shot amount

0.001/0.01/0.1/1 mL (Displayed on controller)

Repeatability

Plastic pipe/tube attachment

Response time: 50 ms

F.S.

± 0.1 %*4*5

Instantaneous flow rate

Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±3 mL/min
Outer diameter of pipe ø 8 0.31 ": ±8 mL/min*4*5

Response time: 500 ms

Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±1.0 mL/min
Outer diameter of pipe ø 8 0.31 ": ±2.6 mL/min*4

Metal pipe attachment

Response time: 50 ms

F.S.

Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±0.3 %
Outer diameter of pipe ø 8 0.31 ": ±0.15 %*4*5

Instantaneous flow rate

Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±9 mL/min
Outer diameter of pipe ø 8 0.31 ": ±12 mL/min*4*5

Response time: 500 ms

Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : ±2.9 mL/min
Outer diameter of pipe ø 8 0.31 ": ±3.8 mL/min*4

Hysteresis

Variable

Integrated unit display

0.1/1/10/100/1000/10000 mL (displayed on controller)

Display method

Status indicator

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529) , IP68G (JIS C0920) *6

Ambient temperature

-10 to 60 °C (No freezing) 14 to 140 °F

Relative humidity

35 % to 85 %RH (No condensation)

Vibration resistance

10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

Shock resistance

50 G 11 ms 3 times each for X,Y,Z direction

Material

Sensor head

Head body: PPS/PPSU, in-cable amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM

Clamp set

For plastic pipe

Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7

For metal pipe

Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7

Weight

Approx. 250 g

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
*2 When using stainless steel or iron pipes, the ideal pipe wall thickness is as follows, FD-XS1: approx. 0.5 mm 0.02", FD-XS8: approx. 1 mm 0.04", FD-XS20: approx. 1 0.04" to 2 mm 0.08". FD-X signal strength and stability will decrease as the thickness of the pipe wall increases or decreases from the suggested size.
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale value) listed in the table according to the rated flow range.
*5 The longer the response time is set, the more repeatability is improved. As a guideline, use √ (50 ms/response time) times.
*6 The connector part of the sensor head cable is IP65/IP67.

keyence Stock Image
Keyence SJ-H228C Keyence
Sale price€0,00
Sold Out

Specifications

Model

SJ-H228C

Type

HC

Ion generation method

Corona discharge

Structure

Shock-proof, resistance-coupled

Voltage application method/applied voltage

Pulse AC method/±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Cleanliness

ISO 14644-1 Class 2 *2

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *3

Effective length

2280 mm 89.76" *4

No. ofelectrodes

36

Static elimination bar length

2240 mm 88.19"

Rating

Power voltage

24 VDC-36 V±10%

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32.0°F to 104.0°F

Relative humidity

35 to 85% RH (No condensation)

Material

Electrode probe

Silicon

Main unit

ABS resin/PC

Weight

Static elimination bar

2350 g 82.89 oz

*1 Value measured under the following conditions:
Operating distance: 300 mm 11.81"
Air supply pressure: 0.2 MPa
Frequency: 68 Hz
Ambient operating temperature: 0 to +40°C 32.0°F to 104.0°F
Ambient operating humidity: 35 to 65%RH
Measurement position: Center of bar
* Under a 0.3 m/s 1.0 ft/s downflow
*2 Contact KEYENCE for detailed conditions.
*3 Contact KEYENCE when using the air purge function with intermittent air supply.
*4 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence CV-L35 Keyence
Sale price€0,00
Sold Out

Specifications

Model

CV-L35

Focal point

35 mm 1.38"

F-stop range (aperture)

F1.6 to F16

Minimum WD

0.3 m 1.0'

Mount

C-mount

Filter size

30.5 mm 1.20" P0.5

Compatible image sensor size

2/3"

TV distortion

-0.2 % (-0.08 %)*1

Resolving power

100 cycles/mm at center, 40 cycles/mm on periphery

Ambient temperature/humidity range

0 to +50 °C 32 to 122°F, 35 to 80 % RH (No condensation)

Polarizing filter

OP-54030

Protective filter

CA-LF30

Weight

Approx. 85 g

*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size.

Keyence Stock Image
Keyence RB-500 Keyence
Sale price €4.703,95
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence BZ-H5XZ Keyence
Sale price€0,00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence KV-FL20 Keyence
Sale price€0,00
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence CA-LH50G Keyence
Sale price €824,95
Only 3 units left

Specifications

Model

CA-LH50G

Type

Vibration-resistant models

Compatible image sensor size

2/3"

Focal point

50 mm 1.97"

F-stop range (aperture)

F2.8/4/8/16*1

Minimum WD

0.2 m 0.7'*2

Resolving power

100 cycles/mm (center), 80 cycles/mm (periphery)

Filter size

27.0 mm 1.06" P0.5

TV distortion

-0.03 % (-0.01 %)*3

Mount

C-mount

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 80 % RH (No condensation)

Weight

Approx. 76 g

*1 The vibration-resistant types are designed to have their apertures replaced. When shipped, the OPEN aperture is attached to the lens, so replace this with one of the other included apertures (F4, F8, or F16) as necessary. To use the f-stop (aperture) in the OPEN mode, use the lens without removing the OPEN aperture.
*2 Installing the lens at a distance from the target shorter than the minimum working distance listed in the specifications makes it very likely that the lens will drop out due to vibrations. If the lens is installed in such a position, implement separate countermeasures to prevent the lens from dropping out.
*3 This indicates the specification for the compatible image sensor size. The value in parentheses applies to a 1/3" image sensor size.

Recently viewed