PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CA-DSR3 |
|||
Type |
Back Light |
|||
LED color |
Red |
|||
Power consumption |
3.6 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 40 g |
|||

Specifications
Model |
ER-18N03C |
|||
Type |
Ultra-long distance shielded type Screw type M18 Connector with pigtail (M12 4-pin) NPN output |
|||
Power supply cable length |
0.3 m 1.0' *1 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
15 mm 0.59" ±10% *2 |
||
With distance switching (Mode 2) |
10 mm 0.39" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
20 Hz *3 *4 |
||
With distance switching (Mode 2) |
50 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
45 × 45 mm 1.77" × 1.77" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
NPN output: 1040 mW or less (44 mA or less at 24 V, 65 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 85 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
AS-440-10U |
|||
Type |
General-use amplifier unit |
|||
Sensor head |
AH-422 |
|||
Shape |
Cylindrical and threaded, diameter: 22 |
|||
Measuring range |
0 to 10 mm0" to 0.394" |
|||
Analog output voltage |
Output voltage |
0 to 10 V |
||
Impedance |
100 Ω |
|||
Resolution |
0.1% of F.S. |
|||
Linearity |
±1% of F.S. |
|||
Response |
3.3 kHz (-3 dB) |
|||
Temperature |
Sensor head |
0.03% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
0.05% of F.S./°C*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
IP67 |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F, No freezing |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Sensor head |
Approx 200g |
||
Weight (including cord) |
Amplifier unit |
Approx 320g |
||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||

Specifications
Model |
PR-B02 |
|||
Type |
Flat bracket, rear type |
|||
Applicable product |
PR-F Series |
|||
Number included |
1 pcs. |
|||
Material |
SUS316L |
|||
Note |
M3 screw × 2 included |
|||
Weight |
Approx. 10 g |
|||


Specifications
Model |
OP-236 |
|||
Type |
Free-cut Connector |
|||
Applicable product |
Cable outer diameter ø2.2 (Free-cut), FU-8□C Series, FU-□□X Series |
|||
Note |
When using FS2-60/62/65, this adapter and fixing ring are necessary to mount fiber unit. |
|||


Specifications
Model |
CL-L015 *1 |
|||
Type |
Sensor head (15 mm ・Quad type) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||




PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-2425 |
|||
Type |
M4 nut setup |
|||
Applicable product |
FU-63, FU-66, FU-68, FU-73, FU-78, FU-7F, FU-8*C, FU-81C, FU-86, FU-88 |
|||
Number included |
Nut x 2, Washer x 1, Toothed washer x 1 |
|||
Note |
2 sets are necessary for thrubeam units. |
|||


Specifications
Model |
SZ-P10PS |
|||
Type |
Output Cable, PNP |
|||
Applicable product |
SZ-01S |
|||
Length |
10 m 32.81' |
|||
Weight |
Approx. 530 g |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FR-SA2 |
|||
Type |
Short Separated Amplifier Unit Cable Expansion Unit |
|||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
|||
Output |
No. of control outputs |
Maximum 5 |
||
Control output/auxiliary output |
NPN/PNP open collector (switchable) up to 30 VDC or less, max 50 mA for each |
|||
Analog output |
─ |
|||
External input |
Short circuit current: 1.5 mA or less Input time: 500 ms or more |
|||
External communication |
NU Series compatibility |
|||
Analog output accuracy |
Resolution |
─ |
||
Zero accuracy | ||||
Full-scale accuracy | ||||
Expansion |
Connected to FR-SA1 (with FR-S01 connected): up to 8 units (9 units total including main unit)*1 |
|||
Power supply |
Power voltage |
24 VDC +25%/−20%*3*4 including ripple, Class2 or LPS |
||
Power consumption |
When FR-S01 is connected: up to 1690 mW or less (60 mA or less at 24 V) |
|||
Environmental resistance |
Ambient temperature |
–20°C to +55°C -4°F to +131°F (no freezing)*5 |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
|||
Material |
PC |
|||
Weight |
Approx. 90 g 3.17 oz |
|||
*1 You can increase the number of expansion units possible in the system by lowering the total analog output current below 750 mA. For details, contact your nearest KEYENCE office. | ||||

Specifications
Model |
ER-GR12N |
|||
Type |
Environment-resistant all-metal shielded type Screw type M12 Cable NPN output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
7 mm 0.28" ±10% *2 |
|||
Response frequency |
100 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
21 × 21 mm 0.83" × 0.83" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less (42 mA or less at 24 V, 63 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP68G (JIS C 0920), IP69K (DIN40050) |
||
Ambient temperature |
-40 to +85°C -40°F to +185°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface and case: SUS316L, Nut: SUS316L, Toothed lock washer: SUS316L |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 75 g 2.65 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||


Specifications
Model |
KV-XLE02 |
|||
Type |
Ethernet unit |
|||
Connection interface |
RJ-45 8-pole modular connector × 2 ports |
|||
Transmission specifications |
Transmission rate |
10BASE-T: 10 Mbps, 100BASE-TX: 100 Mbps, 1000BASE-T: 1000 Mbps |
||
Transmission media |
10BASE-T: Category 3 or higher UTP or STP (STP is recommended) |
|||
Max. cable length |
10BASE-T: 100 m 328.1' |
|||
Max. number of connectable hubs |
10BASE-T: 4 |
|||
Connectable CPU unit |
KV-X Series/KV-8000A |
|||
Refresh |
Automatic refresh, direct refresh, inter-unit synchronization refresh |
|||
Ethernet functions |
KV socket communication, PLC link, PROTOCOL STUDIO, FTP server/client, KV sensor network, Modbus server*5, MC protocol/SLMP*6, etc. |
|||
Industrial networks |
EtherNet/IP™, PROFINET, EtherCAT®,*7 CC-Link IE Field*8*9 |
|||
Ethernet function execution methods |
Ladder program, unit program (flow) |
|||
Unit program capacity |
3 MB (Max. number of blocks: Approx. 20000) |
|||
flow |
Max. number of flows |
256 |
||
Number of simultaneous activities |
Unlimited |
|||
Flow |
Internal data Memory |
524288 words |
||
PROTOCOL STUDIO |
Transmission method |
Cyclic communication: Tx + Rx, Tx only, Rx only. |
||
Max. number of connected devices |
16 |
|||
Max. number of communication commands |
160/320*10 |
|||
Maximum number of total frames |
Rx: 160/320*10 × 16 Tx: 160/320*10 × 1 |
|||
Max. number of compared received frames |
16 per command |
|||
Maximum number of block elements |
96 per frame |
|||
Transmission data length |
Standard: 1 to 2048 bytes per frame, |
|||
Reception data length | ||||
PLC link |
Communication patterns |
Write, read, transfer |
||
Number of link settings |
512 settings max.*11 |
|||
Link data size |
1440 words max. per setting (bit: 720 words, word: 720 words), |
|||
Data unit |
1 word |
|||
Number of connected models |
16 models max.*11 |
|||
Number of connected units |
64 max.*11 |
|||
Trigger types |
Cyclic/event (64 settings max. for event*11) |
|||
Update interval |
1 to 65535 ms |
|||
Internal current consumption |
200 mA or less |
|||
Weight |
Approx. 190 g 6.71 oz |
|||