Specifications
Model |
WI-C3L |
|||
Type |
Sensor head connecting cable, Standard |
|||
Cable end |
L-shaped |
|||
Length |
3 m 9.84' |
|||

Specifications
Model |
GL-VM207FN |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
207 |
|||
Total length |
2080 mm 81.89" |
|||
Detection height |
2060 mm 81.10" |
|||
Protection height |
2084 mm 82.05" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
12.5 |
|
OFF→ON |
59.1 *3 |
|||
All blocked→ON |
77.2 *4 |
|||
With channel A or B |
ON→OFF |
43.8 |
||
OFF→ON |
128.9 *3 |
|||
All blocked→ON |
190.7 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
191 *5 |
||
Receiver |
219 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
66 *5 |
||
Receiver |
80 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1350 g 47.65 oz |
||
Receiver |
1370 g 48.36 oz |
|||
Total |
2720 g 96.01 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||


Specifications
Model |
GL-R60H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Total length |
47.24" 1200mm |
|||
No. of beam |
60 |
|||
Detection height |
46.46" 1180mm |
|||
Protection height |
48.23" 1225mm |
|||
Beam axis spacing/Lens diameter |
20 mm / ø5 0.79" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
10.9 |
|
OFF→ON |
55.2*2 |
|||
All blocked→ON |
80.4*3 |
|||
Optical synchronization system |
ON→OFF |
15.7 |
||
OFF→ON |
62.4*2 |
|||
All blocked→ON |
99.7*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
72 |
||
Receiver |
82 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1670 g |
||
Receiver |
1680 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
ER-08P |
|||
Type |
Ultra-long distance shielded type Screw type M8 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
4.5 mm 0.18" ±10% *2 |
||
With distance switching (Mode 2) |
3 mm 0.12" ±10% *2 |
|||
Response frequency |
With default settings (Mode 1) |
20 Hz *3 *4 |
||
With distance switching (Mode 2) |
80 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
13.5 × 13.5 mm 0.53" × 0.53" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 65 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
GL-VA1440 |
|||
Compatible with GL-V models |
GL-VM143F, GL-VM72H, GL-VM36L (both PNP/NPN) |
|||
Total length |
1440 mm 56.69" |
|||
Material |
Polycarbonate |
|||
Weight |
150 g |
|||

Specifications
Model |
GL-VM52HN |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
52 |
|||
Total length |
1040 mm 40.94" |
|||
Detection height |
1020 mm 40.16" |
|||
Protection height |
1065 mm 41.93" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
6.0 |
|
OFF→ON |
49.8 *3 |
|||
All blocked→ON |
58.1 *4 |
|||
With channel A or B |
ON→OFF |
17.7 |
||
OFF→ON |
64.9 *3 |
|||
All blocked→ON |
89.7 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
123 *5 |
||
Receiver |
134 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
57 *5 |
||
Receiver |
61 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
680 g 24.00 oz |
||
Receiver |
690 g 24.35 oz |
|||
Total |
1370 g 48.36 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
CA-LMHA10*1 |
|||
Optical magnification |
x1.0 |
|||
Shape |
Coaxial |
|||
Compatible image sensor size |
2/3" |
|||
Field of view (at reference magnification) |
1/3": 3.6 x 4.8 mm 0.14" x 0.19" |
|||
F-stop range (aperture) |
11.1 |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (no condensation) |
|||
WD |
110.1 mm 4.33"*2 |
|||
TV distortion |
0.00 % (2/3") |
|||
Depth-of-field |
0.9 mm 0.04"*3 |
|||
Mount |
C-mount |
|||
Resolution |
7.5 µm 0.30 Mil*4 |
|||
Weight |
Approx. 105 g |
|||
*1 Depending on factors such as the installation orientation and the vibrations of the environment, consider reinforcing the installation such as by implementing countermeasures to hold the lens in place. For information on the locations to hold the lens in place, see the installation examples. | ||||

Specifications
Model |
MP-FG10 |
|||
Type |
Single model |
|||
Connection bore diameter |
G3/8" (10 A) |
|||
Supported gases |
Air and non-corrosive gases |
|||
Supported gas temperature |
-5 to +50°C, 23 to 122°F |
|||
Operating pressure range |
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 |
|||
Pressure resistance |
1.5 MPa, 15 bar, 217.5 psi |
|||
Flow rate |
Detection principle |
Heat based (mass flow rate) |
||
Rated flow range (normal) |
2.0 to 1000.0 L/min |
|||
Zero cut flow rate |
2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM |
|||
Measurement accuracy |
±(1.5% of RD + 0.5% of F.S.) *2 *3 |
|||
Repeatability |
±1.0% of F.S. (with an averaging time of 1.0 s) |
|||
Display resolution |
0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM |
|||
Response time |
150 ms (63% response) *4 |
|||
Averaging time |
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) |
|||
Pressure (Digital value, gauge pressure) |
Rated pressure range |
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi |
||
Measurement accuracy |
±2.0% of F.S. |
|||
Repeatability |
±0.2% of F.S. (with a response time of 50 ms) |
|||
Display resolution |
0.001 MPa, 0.01 bar, 0.1 psi |
|||
Response time |
Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4 |
|||
Humidity (Dew point) |
Rated relative humidity range/ dew point range |
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 |
||
Measurement accuracy |
±4°C, ±7°F *5 *6 |
|||
Display resolution |
5%RH/1°C, 1°F *5 *6 |
|||
Temperature |
Measurement accuracy |
±2.0°C, ±3.6°F *7 |
||
Display resolution |
0.1°C, 0.1°F *7 |
|||
Shut-off valve |
Response time |
1 s or less (closed → open) |
||
Leakage amount |
50 mL/min 0.002 CFM (N) or less |
|||
Filter/regulator (Standard model only) |
Pressure adjustment range |
─ |
||
Filtration degree | ||||
Drainage cup capacity | ||||
Check valve |
Available |
|||
Display |
Color LCD, status indicator |
|||
Data accumulation |
Accumulation period |
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks |
||
Data reading |
USB 2.0/Ethernet |
|||
I/O |
Control output (Ch.1/2/3/4/5) |
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less |
||
Analog output (Ch.1/2) |
4 to 20 mA, load resistance: 260 Ω or less *4 |
|||
External input (Ch.2/3/6) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output |
|||
Power supply |
Power voltage |
24 VDC +25%/-20% (including ripple), Class 2 or LPS |
||
Power consumption |
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current) |
|||
Communication interface |
USB2.0 |
|||
Network compatibility |
When using only this unit: IO-Link (Specification v1.1/COM3) *9 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient temperature |
−5°C to +50°C 23°F to 122°F (no freezing) *11 |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
300 m/s2, XYZ axes, 10 times for each axis |
|||
Material |
Sensor part : PET/PPS/PBT/POM/aluminum/SPHC |
|||
Weight |
Approx. 550 g 19.40 oz |
|||
*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
NU-EC1 |
|||
Name |
Communication unit that supports EtherCAT |
|||
Ethernet |
Compliant standards |
IEEE802.3u (100BASE-TX) |
||
Transmission rate |
100Mbps (100BASE-TX) |
|||
Transmission media |
Category 5e STP |
|||
Distance between nodes |
100 m 328.1' |
|||
Communication ports |
RJ-45x2 |
|||
EtherCAT |
Compatible functions |
Process data object communication (cyclic communication), |
||
Sensor connection |
Connectable sensors |
Sensor amplifier that supports N-bus*1 |
||
Number of connectable units |
16 maximum*2 |
|||
Power supply |
Power is supplied by this product through the wiring-saving connector. |
|||
Allowable passing current |
Total: 1,200 mA or less*3 |
|||
Indicator lamp |
Power indicator (PWR): green LED, |
|||
Power voltage |
24 VDC ± 10%, ripple (P-P) 10% or less |
|||
Power consumption |
1,700 mW or less (70 mA or less at 24 V)*4 |
|||
Environmental resistance |
Pollution degree |
2 |
||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit case and dust cover: polycarbonate, |
|||
Accessories |
Instruction manual, power supply connection connector, end unit × 2 |
|||
Weight |
Approx. 80 g (including connectors) |
|||
*1 "N-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers. | ||||

Specifications
Model |
MD-X1020 |
|||
Type |
Marking unit (controller + head) 13 W Wide area |
|||
2D code reader add-in (sold separately) |
MD-XAD1/MD-XAD1A |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-Axis simultaneous scanning method |
|||
Marking laser |
Type |
YVO4 laser, Class 4 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*1 |
||
Wavelength |
1,064 nm |
|||
Output |
13 W |
|||
Q-switch frequency |
CW (continuous wave), 1 to 400 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*1 |
|||
Marking area |
330 x 330 x 42 mm |
|||
Standard working distance (±variable width) |
300 mm (±21 mm) 11.81" (±0.83") |
|||
Marking resolution |
5 µm |
|||
Scan speed |
Max. 8,000 mm/s 314.96"/s |
|||
Character type |
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji), user font, TrueType font, OpenType font*2 |
||
Barcode |
CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E |
|||
2D code |
QR code, micro QR code, DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, GS1 DataBar Limited, |
|||
Logo image |
Custom character font and logo (CAD) data, BMP/JPEG/PNG/TIFF |
|||
Marking conditions |
Workpiece style |
Stationary marking, Moving marking (constant, encoder) |
||
Character size (marking height/width) |
0.1 to 330 mm 0.004" to 12.99" |
|||
No. of registered programs |
2,000 max. |
|||
No. of program blocks |
256 |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O, contactor control I/O*3 |
|||
Interface |
RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*4 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4.3 ±0.1 m 0.17" ±0.01" |
|||
Cooling method |
Forced air cooling |
|||
Rated voltage and power consumption |
100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, 650 VA max. |
|||
Environmental resistance |
Enclosure rating |
IP64 (marking head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 23.0 kg |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
GL-VM95FP |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
95 |
|||
Total length |
960 mm 37.80" |
|||
Detection height |
940 mm 37.01" |
|||
Protection height |
964 mm 37.95" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
7.8 |
|
OFF→ON |
53.3 *3 |
|||
All blocked→ON |
64.3 *4 |
|||
With channel A or B |
ON→OFF |
25.0 |
||
OFF→ON |
82.1 *3 |
|||
All blocked→ON |
117.7 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
123 *5 |
||
Receiver |
136 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
62 *5 |
||
Receiver |
67 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
630 g 22.23 oz |
||
Receiver |
640 g 22.59 oz |
|||
Total |
1270 g 44.83 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
OP-89163 |
|||
Excitation wavelength |
545/25 nm |
|||
Emission wavelength |
605/70 nm |
|||
Dichroic mirror wavelength |
565 nm |
|||


Specifications
Model |
CA-LHR8 |
|||
Focal point |
8.5 mm 0.33" |
|||
F-stop range (aperture) |
F1.8 to F16 |
|||
Minimum WD |
0.1 m 0.3' |
|||
Mount |
C-mount |
|||
Filter size |
34.0 mm 1.34" P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
0.31 % (-0.02 %)*1 |
|||
Resolving power |
200 cycles/mm at center, 140 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Lens coating |
WIDE, BAND MULTICOATING |
|||
Weight |
Approx. 115 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||

Specifications
Model |
LV-22A |
|||
Type |
NPN output |
|||
Main unit/expansion unit |
Expansion unit (1 line) |
|||
Control output |
NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.) |
|||
Response speed |
FINE : 80 µs , TURBO : 500 µs , SUPER , TURBO : 4 ms |
|||
Number of interference |
FINE : None , TURBO : 2 units , SUPER : 4 units |
|||
Protection circuit |
Reversed polarity protection, over-current protection, surge absorber |
|||
Unit expansion |
Up to 7 additional expansion units can be installed (8 units including the main unit), |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less (For the LV-20A/22A/22AP, the power supply voltage is supplied from the main unit.) |
||
Power consumption |
1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) *1 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Main unit |
Polycarbonate |
||
Case | ||||
Weight |
Approx. 75 g |
|||
*1 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected. | ||||

Specifications
Model |
EV-108U*1 |
|||
Type |
Non-shielded |
|||
Shape |
M8 |
|||
Detecting distance |
4 mm 0.16" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
20 x 20 mm 0.79" x 0.79" |
|||
Hysteresis |
20% max. of detecting distance, within -10 to +70°C 14 to 158°F |
|||
Response frequency |
800 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance, |
|||
Control output |
5 to 80 mA |
|||
Protection circuit |
Reversed polarity,surge voltage |
|||
Cable length |
2 m 6.6' |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 20 % or less |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Stainless steel (SUS304) |
|||
Accessories |
Nut × 2, toothed washer × 1, instruction manual |
|||
Weight |
Approx. 42 g |
|||
*1 This product does not comply with EMC directive. | ||||