Specifications
Model |
FU-33*1 |
|||
Beam emitting direction |
Side |
|||
Fibre unit length |
1 m39.37" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 10 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
TH-320 |
|||
Type |
Detecting minute metallic objects |
|||
Minimum detectable object |
0.3 mm dia. |
|||
Detecting area |
20 mm |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 210 g |
|||
*1 Data obtained with the amplifi er set at maximum sensitivity when target was travelling at 500 mm 19.69". | ||||

Specifications
Model |
CA-DQW10 |
|||
Type |
Square Light (Direct) |
|||
LED color |
White |
|||
Diffusion plate |
OP-42283*1 |
|||
Power consumption |
11.5 W*2 |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 370 g |
|||
*1 These models are for a single bar. Four sets are required for the whole square. | ||||

Specifications
Model |
GL-VA480 |
|||
Compatible with GL-V models |
GL-VM47F, GL-VM24H, GL-VM12L (both PNP/NPN) |
|||
Total length |
480 mm 18.90" |
|||
Material |
Polycarbonate |
|||
Weight |
50 g |
|||

Specifications
Model |
GL-RS5 |
|||
Type |
Joint Cable |
|||
Number included |
1 cable |
|||
Cable end |
Both ends of the connector (Black) are the same shape. The connector can be connected in either direction. |
|||
Length |
5 m 16.40' |
|||
Material |
Main unit connection connector: PBT, Cable: PVC |
|||
Note |
Use this when using the product in a one-line system or when connecting the product in series. |
|||
Weight |
Approx. 260 g |
|||

Specifications
Model |
OP-88818 *1 |
|||
Material |
A5052 (black electrode position coating) |
|||
Weight |
Approx. 480 g (not including camera, illumination, or mounting screws) |
|||
*1 The environmental resistance depends on the specifications of the camera and illumination to be used. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-88068 |
|||
Overview |
This is a connector cable for the M12 connector sensor. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M12 connector sensor |
|||
Cable end |
M12 L-shaped - Loose wire |
|||
Length |
5 m 16.40' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 160 g |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-11*1 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Metal wire (parallel) with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 19 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
IV4-LG4C |
|||
Compatible sensor |
IV4-G400CA |
|||
Lights |
Illumination |
White LED |
||
Power supply |
Power supplied via connected amplifier |
|||
Environmental resistance |
Enclosure rating |
IP67 *1 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Main unit case: Aluminum die-casting/PBT. |
|||
Weight |
Approx. 150 g 5.30 oz |
|||
*1 Only when attached to applicable sensor. Except when polarizing filters (OP-88644/OP-88645/OP-88646/OP-88647) are installed. | ||||



Specifications
Model |
CA-U5 |
|||
Input conditions |
Rated input voltage |
85 to 264 VAC 47 to 63 Hz, 110 to 370 VDC *1 |
||
Inputconditions |
Efficiency |
82% (100 VAC) /85% (200 VAC) typ. (at 100% load) |
||
Input conditions |
Rated input current |
3.9 A max. (100 VAC)/ 1.8 A max. (200 VAC) |
||
Output conditions |
Rated output voltage |
24 VDC |
||
Rated output current |
12.5 A |
|||
Protection |
Overvoltage protection |
15.6 A or more *2 |
||
Activates at 26.4 V or more. Voltage interruption method, recovers when input is applied again. *3 | ||||
Applicable standards |
Safety standards |
UL: UL508, UL60950-1 |
||
EMC standard |
FCC Part15B ClassA, EN55011 ClassA, EN61000-6-2 |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
85%RH or less (No condensation) |
|||
Storage temperature |
-20 to +70 °C -4 to +158 °F (No freezing) |
|||
Weight |
Approx. 1540 g 3.40 lb |
|||
*1 When applying for safety standards, the rated input voltage was 100 to 240 VAC and the rated frequency was 50/60 Hz. | ||||

Specifications
Model |
OP-87285 |
|||
Overview |
Adapter converting G3/4 male connection aperture to NPT1/4 male of GP-M Series. |
|||
Applicable product |
GP-M Series sensor main unit |
|||
Number included |
1 pcs. |
|||
Connection port |
G3/4 female and NPT1/4 male on respective side |
|||
Material |
SUSXM7 |
|||

Specifications
Model |
VT5-X12 |
|||
General specifications |
Current consumption. |
1400 mA or less |
||
Power voltage |
24 VDC ±20% |
|||
Vibration resistance |
Intermittent vibration |
Frequency: 5 to 9 Hz |
Half amplitude: 3.5 mm 0.14"*1 |
|
Frequency: 9 to 150 Hz |
Acceleration: 9.8 m/s2 32.2'/s2*1 |
|||
Continuous vibration |
Frequency: 5 to 9 Hz |
Half amplitude: 1.75 mm 0.07"*1 |
||
Frequency: 9 to 150 Hz |
Acceleration: 4.9 m/s2 16.1'/s2*1 |
|||
Structure |
Construction with IP65F or equivalent dust and water drop protection only for the front operating part of the panel embedded type *2 |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Noise resistance |
1500 Vp-p or more, Pulse duration: 1 μs, 50 ns (based on noise simulator) |
|||
Withstand voltage |
1500 VAC for one minute (between power terminal and housing) |
|||
Insulation resistance |
50 MΩ or more (between power terminal and housing, with 500 VDC megohmmeter) |
|||
Operating environment |
No dust, corrosive gases, or other harmful substances present |
|||
Ambient operating temperature |
0 to 50°C 32 to 122°F*3 |
|||
Ambient operating humidity |
20 to 85% (no condensation)*4 |
|||
Storage ambient temperature |
−20 to +60°C -4 to +140°F (no freezing) |
|||
Ambient storage humidity |
20 to 85% (no condensation)*4 |
|||
Weight |
Approx. 2200 g |
|||
Performance specifications |
Displaypanel |
Display elements |
TFT LCD |
|
Display color |
16 million colors |
|||
Number of dots |
W1024 × H768 dots |
|||
Active display area |
W245.8 × H184.3mm 9.68" × 7.26" |
|||
Data backup |
Screen data |
Flash ROM |
||
Recording data |
SRAM, Backup: Primary lithium battery (Service life: 5 years or more at 25°C 77°F) |
|||
RGB input |
Display colors |
16 million colors |
||
Signal type |
Analog RGB |
|||
Vertical synchronization frequency |
XGA (1024 × 768): 60 Hz |
|||
DVI-D output |
Signal type |
DVI-D |
||
Vertical synchronization frequency |
60 Hz |
|||
Output resolution |
Full HD*5: W1920 × H1080 dots |
|||
Backlightlamp |
System |
White LED (Non-replaceable) |
||
Service life (normal temperature andhumidity) |
Approx. 50,000 hours |
|||
Touchswitch |
System |
Analog resistive |
||
Operating force |
0.98 N or less |
|||
Life-span |
1 million operations or more |
|||
Screen data internal memory |
Memory capacity |
256 MB |
||
Calendar timer |
Accuracy: ±40 seconds per month at 25°C 77°F, Backup: Primary lithium battery (Service life: 5 years or more at 25°C 77°F) |
|||
*1 Compliant with JIS B3502,IEC 61131-2 | ||||

Specifications
Model |
CA-LMA2*1 |
|||
Type |
Coaxial |
|||
Optical magnification (reference magnification) |
x2 |
|||
Magnification range |
Approx. ±3 % relative to reference axis |
|||
WD (at reference magnification) |
66.9 mm 2.63" *2 |
|||
Compatible image sensor size |
1/2" |
|||
Field of view (at reference magnification) |
1/3" |
1.8 x 2.4 mm 0.071" x 0.094" |
||
1/2" |
2.4 x 3.2 mm 0.094" x 0.126" |
|||
2/3" |
- |
|||
F-stop range (aperture) |
15.4 |
|||
Depth-of-field |
400 µm 15.75 Mil*3 |
|||
Max. TV distortion |
-0.04 % |
|||
Resolution |
5.1 µm 0.20 Mil*4 |
|||
Mount |
C-mount |
|||
Ambient temperature/humidity range |
0 to +50 °C 32 to 122 °F, 80 % RH (No condensation) |
|||
Weight |
Approx. 62 g |
|||
*1 The above values are all calculated according to optical design values. Actual values for individual lenses will differ according to precision of assembly. | ||||

Specifications
Model |
XM-BC1 |
|||
Charging part |
Charging time |
Approx. 6.5 hours |
||
Charging status LED |
2-color LED (red: charging, green: charging complete) |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C (No freezing) |
||
Relative humidity |
20 to 85%RH (No condensation) |
|||
Storage temperature |
-20 to +60°C (No freezing) |
|||
Storage relative humidity |
20 to 85%RH (No condensation) |
|||
Weight |
Approx. 390 g |
|||