Distance & Measurement Sensors

504 products

Showing 481 - 504 of 504 products

Showing 481 - 504 of 504 products
View
Leuze Stock Image
Leuze ODSL30D485-30M-S12 Leuze
Sale price€0,00
Sold Out
Leuze Optical Distance Sensor (P/N: ODSL 30/D485-30M-S12). Laser or LED distance measurement sensor providing precise analog and switching outputs for position control, height measurement, and loop control. High accuracy with configurable measuring range and IO-Link communication for factory automation.
Leuze Stock Image
Leuze ODSL96BMC6052000 Leuze
Sale price €2.769,95
Only 3 units left
Leuze Optical Distance Sensor (P/N: ODSL96BMC6052000). Laser or LED distance measurement sensor providing precise analog and switching outputs for position control, height measurement, and loop control. High accuracy with configurable measuring range and IO-Link communication for factory automation.
Leuze Stock Image
Leuze ODSL8C66-200-S12 Leuze
Sale price€0,00
Sold Out
Leuze Optical Distance Sensor (P/N: ODSL 8/C66-200-S12). Laser or LED distance measurement sensor providing precise analog and switching outputs for position control, height measurement, and loop control. High accuracy with configurable measuring range and IO-Link communication for factory automation.
Keyence New Stock Image
Keyence LR-XN11C Keyence
Sale price €374,95
In stock, 17 units

Specifications

Model

LR-XN11C

Type

NPN Output/PNP Output (Selectable output)

Cable/Connector

M8 connector*1

Main Unit/Expansion Unit

Main Unit (expansion not possible)

No. of Control Outputs

2*2

No. of External Inputs

1*2

Response Time

500 µs*3/1 ms/3 ms/10 ms/200 ms Selectable

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

Open collector, 30 VDC or lower, N.O./N.C.
100 mA or lower for 1 output; 100 mA or lower in total for 2 outputs
Residual voltage NPN: 1.4 V or lower (output current: 10 mA or lower)/2 V or lower (output current: 10 to 100 mA), PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA)

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable
Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower
Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)

Unit Expansion

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

Power supply

Power voltage

16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current)

Environmental resistance

Ambient temperature

−20 to +55°C -4°F to 131°F (no freezing)*5

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 (50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

Accessories

Instruction manual

Weight

Approx. 22 g

*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.
*2 Output 2 and the external input are selectable.
*3 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*4 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*5 Expansion by 1 or 2 units: −20 to +55°C -4°F to 131°F; Expansion by 3 to 10 units: -20 to +50°C -4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C -4°F to 113°F

Keyence New Stock Image
Keyence LR-TB2000CL Keyence
Sale price €416,95
In stock, 17 units

Specifications

Model

LR-TB2000CL

Type

Cable with connector M12

Detectable distance

60 to 2000 mm 2.36" to 78.74"*1

Spot diameter

Approx. ø4 mm ø0.16"

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1,FDA (CDRH) Part1040.10*2)

Mutual interference prevention function

4 units (when using the interference prevention function)

Timer

OFF/OFF delay/ON delay/One-shot

Response time

2 ms/20 ms/50 ms/200 ms/2000 ms
selectable

I/O

Control output

NPN open collector/PNP open collector selectable
30 VDC or less, 50 mA or less, residual voltage: 2 V or less,
N.O./N.C. selectable
*3*4

Analog output

-

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge

Power voltage

20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Current consumption

45 mA or less (without load)*5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp/Sunlight: 10,0000 lux or less

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: Zinc die cast (Nickel chrome plating),
Indicator cover and buttons: PES,
Lens cover and display: PMMA (scratch-resistant coating specifications),
Cable bushing: PBT,
Cable: PVC,
M12 connector: TPE, PBT, Nickel-plated brass

Accompanying items

Instruction manual

Weight

Approx. 85 g

*1 The range for displayable distance is from 50 to 2200.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 You can select the I/O from the following combinations.
Control output × 2, control output + external input
Control output + analog output (LR-TB5000/TB5000C/TB5000CL only)
External input + analog output (LR-TB5000/TB5000C/TB5000CL only)
(For details on the setting method, see the instruction manual.)
*4 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website (http://www.keyence.com).
If you are using the product in an environment in which you cannot download files over the Internet, contact your nearest KEYENCE office.
*5 145 mA or less (with load)

Keyence Stock Image
Keyence LB-1101 Keyence
Sale price €875,95
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

LK-G35 Keyence
Keyence LK-G35 Keyence
Sale price €1.419,95
In stock, 33 units

Specifications

Model

LK-G35

Reference distance

30 mm 1.18"(Diffuse reflection), 23.5 mm 0.93"(Specular reflection)

Measuring range

±5 mm ±0.2"(Diffuse reflection),±4.5 mm ±0.18"(Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 3R laser product (JIS C6802)

Laser Class

Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10)

Output

4.8 mW

Spot diameter (at reference distance)

Approx. 30 x 850 µm
0.001181 x 0.0335"

Linearity

±0.05% of F.S. (F.S.= ±5 mm ±0.2")*1

Repeatability

0.05 µm (0.01 µm)*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C (F.S.= ±5 mm ±0.2")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 280 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

Keyence Stock Image
Keyence LK-801 Keyence
Sale price€0,00
Sold Out

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

LK-G80 Keyence
Keyence LK-G80 Keyence
Sale price €1.687,95
Only 9 units left

Specifications

Model

LK-G80

Reference distance

80 mm 3.15"(Diffuse reflection),75.2 mm 2.96"(Specular reflection)

Measuring range

±15 mm ±0.59"(Diffuse reflection),±14 mm ±0.55"(Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 3R laser product (JIS C6802)

Laser Class

Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10)

Output

4.8 mW

Spot diameter (at reference distance)

Approx. ø70 µm ø0.002756"

Linearity

±0.05% of F.S. (F.S.= ±15 mm ±0.59")*1

Repeatability

0.2 µm 0.000008"*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C (F.S.= ±15 mm ±0.59")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 380 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

LK-G405 Keyence
Keyence LK-G405 Keyence
Sale price €2.311,95
In stock, 42 units

Specifications

Model

LK-G405

Reference distance

400 mm 15.75"(Diffuse reflection),398 mm 15.67"(Specular reflection)

Measuring range

±100 mm (diffuse reflection), ±99 mm (specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 3R laser product (JIS C6802)

Laser Class

Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10)

Output

4.8 mW maximum

Spot diameter (at reference distance)

Approx. 290 x 8,300 µm

Linearity

±0.05% of F.S. (F.S. = ±100 mm ±3.94")*1

Repeatability

2 µm 0.000079"*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./˚C (F.S.= ±100 mm ±3.94")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 380 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

LK-H028 Keyence
Keyence LK-H028 Keyence
Sale price €2.422,95
Only 6 units left

Sensor Head, Wide Type, Laser Class 3B

Keyence Stock Image
Keyence LB-1003 Keyence
Sale price €1.844,95
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence LR-XH250 Keyence
Sale price €456,95
In stock, 12 units

Specifications

Model

LR-XH250

Type

Cable Length: 2 m 6.6'

Detecting Distance

30 to 250 mm 1.18" to 9.84"

Standard Detectable Deviation

30 to 180 mm: 9 mm, 180 to 250 mm: 18 mm
1.18" to 7.09": 0.35", 7.09" to 9.84": 0.71

Display Resolution

1 to 2 mm 0.04" to 0.08"

Spot Size

Approx. 0.8 mm × 1.2 mm 0.03" × 0.05"
(at a detecting distance of 250 mm 9.84")

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 laser product (IEC60825-1, FDA (CDRH), Part1040.10*1)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 8000 lux or less, Sunlight: 8000 lux or less

Ambient temperature

-10°C to +50°C 14°F to 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G); 6 times each for X, Y, and Z axes

Material

Case: SUS316L; Lens Cover: PSU; Gasket: FKM (lens cover), EVM (cable)

Accessories

Laser warning label

Weight

approx. 75 g

*1 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.

Keyence Stock Image
Keyence LK-2011 Keyence
Sale price €4.983,95
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence LK-2001 Keyence
Sale price €278,95
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
LK-G150 Keyence
Keyence LK-G150 Keyence
Sale price €2.199,95
In stock, 68 units

Specifications

Model

LK-G150

Reference distance

150 mm 5.91" (Diffuse reflection),147.5 mm 5.81" (Specular reflection)

Measuring range

±40 mm ±1.57" (Diffuse reflection), ±39 mm ±1.54" (Specular reflection)

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 3R laser product (JIS C6802)

Laser Class

Class 3R (IEC 60825-1), Class IIIa (FDA CDRH Part 1040.10)

Output

4.8 mW maximum

Spot diameter (at reference distance)

Approx. ø120 µm ø0.004724"

Linearity

±0.05% of F.S. (F.S.= ±40 mm ±1.57")*1

Repeatability

0.5 µm 0.000020"*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01% of F.S./°C (F.S.= ±40 mm ±1.57")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 290 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

keyence Stock Image
Keyence LK-G08 Keyence
Sale price €2.099,95
Only 3 units left

Specifications

Model

LK-G08

Reference distance

8 mm 0.32"

Measuring range

±0.8 mm

Light source

Type

Red semiconductor laser

Wavelength

655nm (Visible light), Class 1 laser product (JIS C6802)

Output

0.3 mW

Spot diameter (at reference distance)

Approx. ø20 µm ø0.000787"

Linearity

±0.05% of F.S. (F.S. = ±0.8 mm ±0.03")*1

Repeatability

0.02 µm (0.01 µm)*2

Sampling frequency

20/50/100/200/500/1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.02% of F.S./°C (F.S. = ±0.8 mm 0.031")

Environmental resistance

Enclosure rating

-

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

+10 to +40 °C 50 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.75 mm 0.03", 2 hours in each of the X, Y, and Z directions

Material

Aluminum

Weight

Approx. 245 g (including the cable)

*1 This value was taken when measuring a KEYENCE standard target (ceramic) in standard mode.
*2 These values were taken when measuring a KEYENCE standard target (SUS) at a reference distance and with the number of averaging measurements set to 4,096

LK-5000P Keyence
Keyence LK-5000P Keyence
Sale price €1.642,95
Only 4 units left

Ultra High-Speed/High-Accuracy Laser Displacement Sensor

Keyence Stock Image
Keyence LB-1001 Keyence
Sale price €723,95
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence LR-ZB100N Keyence
Sale price €215,95
In stock, 11 units

Specifications

Model

LR-ZB100N

Type

Distance based laser sensor

Appearance

Rectangular

Output

NPN

Cable connection

2 m cable

Detectable distance

35 to 100 mm 1.38" to 3.94" (650 to 0)*1

Standard detectable deviation

35 to 50 mm 1.38" to 1.97": 1.5 mm 0.06"
50 to 100 mm 1.97" to 3.94": 3 mm 0.12"

Display resolution

2 (0.2 mm 0.008")

Spot size

Approx. 2 × 1 mm 0.08" × 0.04" at 100 mm 3.94"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*2)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

NPN Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

External input

Input time calibration: 35 ms or more ON, 35 ms or more OFF
Laser emission stop: 2 ms or more ON, 20 ms or more OFF
Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 4,000 lux or less
Sunlight: 8,000 lux or less*4

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 110 g (Including cable)

*1 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*2 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*3 Have passed resistance tests with cleaning agents from multiple manufactures.
*4 When the response time is 10 ms

Keyence New Stock Image
Keyence LJ-X8020 Keyence
Sale price €7.088,95
Only 2 units left

Specifications

Model

LJ-X8020

Reference distance

20 mm 0.79"

Measurement range

Z-axis (height)

±2.2 mm 0.09" (F.S.=4.4 mm 0.17")

X-axis (width)

NEAR side

7 mm 0.28"

Reference distance

7.5 mm 0.30"

FAR side

8 mm 0.31"

Light source

Blue semiconductor laser

Light source

Wavelength

405 nm (visible light)

Laser class

Class 2M laser product (IEC60825-1, FDA (CDRH) Part 1040.10 *1) *2

Output

10 mW

Spot size

Approx. 16 mm × 32 μm 0.63" × 0.0013" (reference distance)

Repeatability

Z-axis (height)

0.3 μm 0.000012" *3*4

X-axis (width)

0.3 μm 0.000012" *3*5

Linearity

Z-axis (height)

±0.05% of F.S. (±0.012%) *6

Profile data interval

X-axis (width)

2.5 μm 0.000098" (2 μm 0.000079"~) *7

Profile data count

3200 points

HDR (high dynamic range)

Single-shot HDR *8

Laser irradiation position confirmation function

Light source

Blue LED (405 nm)

Temperature characteristic

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529) *9

Ambient light

Incandescent lamp: 10,000 lux or less *10

Ambient temperature

0 to +45°C 32 to +113°F *11

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 3 hours each for X, Y, and Z axes

Shock resistance

15 G / 6 msec

Material

Aluminum

Weight

Approx. 1000 g 2.20 lb

*1 Classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Values measured by averaging 4096 times at the reference distance.
*4 The measured target is a KEYENCE standard target. Value when the average height of the default setting area is measured with height and position tools. All other settings are default values.
*5 The measured target is a pin gauge. Value when the point of intersection for the pin gauge rounded surface and edge level is measured using height and position tools. All other settings are default values.
*6 The measured target is a KEYENCE standard target. Profile data when measured by smoothing 64 times and averaging 8 times. All other settings are default values. Values inside parentheses are representative examples of averages for all profile data.
*7 The profile data interval can be changed. If changed, the measurement range in the X direction will also change.
*8 A characteristic that allows for stable, high-precision measurement with a single capture (exposure) at all levels of reflectance, from black (low) to glossy surfaces (high).
*9 The value when a head cable (CB-B*) or extension cable (CB-B*E) is connected. Does not include CB-B**L connection.
*10 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*11 The head needs to be mounted to a metal plate to be used.

Keyence New Stock Image
Keyence LR-ZB250C3P Keyence
Sale price €268,95
In stock, 11 units

Specifications

Model

LR-ZB250C3P*1

Type

Distance based laser sensor

Appearance

Rectangular

Output

PNP

Cable connection

M8 connector, 3-pin

Detectable distance

35 to 250 mm 1.38" to 9.84" (215 to 0)*2

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 250 mm 7.09" to 9.84": 25 mm 0.98"

Display resolution

1 to 3 (1 to 3 mm 0.04" to 0.12")

Spot size

Approx. 2.4 × 1.2 mm 0.09" × 0.05" at 250 mm 9.84"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 1 laser product
(IEC60825-1, FDA (CDRH) Part1040.10*3)

Function

Indicator

3-digit 7-segment display (red),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*4, Diversey*4

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less*5

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
Certification/Identification label (FDA)

Weight

Approx. 55 g

*1 M8 connector (3-pin) type does not include the external input function.
*2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*3 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*4 Have passed resistance tests with cleaning agents from multiple manufactures.
*5 When the response time is 10 ms

Keyence Stock Image
Keyence LJ-X8200 Keyence
Sale price €6.153,95
Only 2 units left

Specifications

Model

LJ-X8200

Reference distance

245 mm 9.65"

Measurement range

Z-axis (height)

±34 mm 1.34" (F.S.=68 mm 2.68")

X-axis (width)

NEAR side

64 mm 2.52"

Reference distance

72 mm 2.83"

FAR side

80 mm 3.15"

Light source

Blue semiconductor laser

Light source

Wavelength

405 nm (visible light)

Laser class

Class 2M laser product (IEC60825-1, FDA (CDRH) Part 1040.10 *1) *2

Output

10 mW

Spot size

Approx. 115 mm × 116 μm 4.53" × 0.0046" (reference distance)

Repeatability

Z-axis (height)

1 μm 0.000039" *3*4

X-axis (width)

3 μm 0.000118" *3*5

Linearity

Z-axis (height)

±0.04% of F.S. (±0.006%) *6

Profile data interval

X-axis (width)

25 μm 0.0010" (20 μm 0.0008"~) *7

Profile data count

3200 points

HDR (high dynamic range)

Single-shot HDR *8

Laser irradiation position confirmation function

Light source

Blue LED (405 nm)

Temperature characteristic

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529) *9

Ambient light

Incandescent lamp: 10,000 lux or less *10

Ambient temperature

0 to +45°C 32 to +113°F *11

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 3 hours each for X, Y, and Z axes

Shock resistance

15 G / 6 msec

Material

Aluminum

Weight

Approx. 1200 g 2.65 lb

*1 Classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Values measured by averaging 4096 times at the reference distance.
*4 The measured target is a KEYENCE standard target. Value when the average height of the default setting area is measured with height and position tools. All other settings are default values.
*5 The measured target is a pin gauge. Value when the point of intersection for the pin gauge rounded surface and edge level is measured using height and position tools. All other settings are default values.
*6 The measured target is a KEYENCE standard target. Profile data when measured by smoothing 64 times and averaging 8 times. All other settings are default values. Values inside parentheses are representative examples of averages for all profile data.
*7 The profile data interval can be changed. If changed, the measurement range in the X direction will also change.
*8 A characteristic that allows for stable, high-precision measurement with a single capture (exposure) at all levels of reflectance, from black (low) to glossy surfaces (high).
*9 The value when a head cable (CB-B*) or extension cable (CB-B*E) is connected. Does not include CB-B**L connection.
*10 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*11 The head needs to be mounted to a metal plate to be used.

Keyence Stock Image
Keyence LK-2000 Keyence
Sale price €1.122,95
Only 4 units left
Buy the Keyence LK-2000 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence LK-2000 is a direct drop-in replacement for existing installations and ships ready for integration.

Recently viewed