ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
0ac951c1-9b40-4f47-a751-2ab056ffe1d8 Italy
47481f31-3db7-43fa-90e7-510370035ce9 Germany
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
585d169a-087c-4da7-ad22-14f7211e98a1 Netherlands
ff4fab3b-79ba-48cf-8ed4-5efe459324fa Estonia
f70a208d-8500-4b87-8e80-56eb4dcb62f2 Greece
ab874939-835a-44db-8d0f-0ae656d2b42c Portugal
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
bd36d84d-14a0-4614-8240-3ca69ef29c39 Sweden
9be1dbef-ca32-4fe8-b574-89b5a88b48ee Germany
de6316e9-bdb1-43e5-b16d-b95b72c5dfb4 Germany
602c2f91-c382-4023-97d1-6af1a6d6081a France
8cba98fa-d5d2-4ec5-bf3c-1960563892a0 Netherlands
bd36d84d-14a0-4614-8240-3ca69ef29c39 Sweden
9be1dbef-ca32-4fe8-b574-89b5a88b48ee Germany
de6316e9-bdb1-43e5-b16d-b95b72c5dfb4 Germany
602c2f91-c382-4023-97d1-6af1a6d6081a France
8cba98fa-d5d2-4ec5-bf3c-1960563892a0 Netherlands
17496149-365a-445d-af68-54e4bc6db1db Spain
14cd69a0-0aec-4cca-80b5-96c95c8af3e4 Netherlands
e3656c3b-bce5-47e5-afeb-7f009b696b0a Bulgaria
de206646-cbea-472d-bc5e-38f523d75152 Sweden
14cd69a0-0aec-4cca-80b5-96c95c8af3e4 Netherlands
cce5ff42-1b35-421b-84db-020aa9af0a7a Poland
ff4fab3b-79ba-48cf-8ed4-5efe459324fa Estonia
f70a208d-8500-4b87-8e80-56eb4dcb62f2 Greece
ab874939-835a-44db-8d0f-0ae656d2b42c Portugal
e3656c3b-bce5-47e5-afeb-7f009b696b0a Bulgaria
de206646-cbea-472d-bc5e-38f523d75152 Sweden
cce5ff42-1b35-421b-84db-020aa9af0a7a Poland
17496149-365a-445d-af68-54e4bc6db1db Spain
a8e7d90f-4315-4279-a905-8664948cfaff Poland
4dc6cdf8-32d7-49b1-a117-c0ce3ad2f633 Norway
c3b8ec46-1389-4df7-8ed0-faeafd3b6c2d Finland
17032ab3-d170-46a5-983e-858cc49ab98d Netherlands
a4916536-3f0a-4c32-979a-0ef6d86b33ea Germany
7f380bd4-62bf-43fd-b963-40441f5c8867 Denmark
29282873-f42c-494c-a6f0-215e2e76a9f8 Germany
31575187-3d16-43b1-ad84-85ff5a7ee577 Croatia
99bddbbc-3e48-4a6d-b5b0-61c3be192e43 Czech Republic
3024527b-6e7a-4d6a-a536-159275b759d0 Poland
83801f67-afd3-4187-897a-3539e975ecba Netherlands
585d169a-087c-4da7-ad22-14f7211e98a1 Netherlands
a8e7d90f-4315-4279-a905-8664948cfaff Poland
4dc6cdf8-32d7-49b1-a117-c0ce3ad2f633 Norway
c3b8ec46-1389-4df7-8ed0-faeafd3b6c2d Finland
17032ab3-d170-46a5-983e-858cc49ab98d Netherlands
a4916536-3f0a-4c32-979a-0ef6d86b33ea Germany
7f380bd4-62bf-43fd-b963-40441f5c8867 Denmark
29282873-f42c-494c-a6f0-215e2e76a9f8 Germany
31575187-3d16-43b1-ad84-85ff5a7ee577 Croatia
99bddbbc-3e48-4a6d-b5b0-61c3be192e43 Czech Republic
3024527b-6e7a-4d6a-a536-159275b759d0 Poland
83801f67-afd3-4187-897a-3539e975ecba Netherlands
47481f31-3db7-43fa-90e7-510370035ce9 Germany
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
585d169a-087c-4da7-ad22-14f7211e98a1 Netherlands
ff4fab3b-79ba-48cf-8ed4-5efe459324fa Estonia
f70a208d-8500-4b87-8e80-56eb4dcb62f2 Greece
ab874939-835a-44db-8d0f-0ae656d2b42c Portugal
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
bd36d84d-14a0-4614-8240-3ca69ef29c39 Sweden
9be1dbef-ca32-4fe8-b574-89b5a88b48ee Germany
de6316e9-bdb1-43e5-b16d-b95b72c5dfb4 Germany
Environmental
Ordering
XT1NE4160AFF000XXX
4379239
3182447
8015644013226
1 piece
85362090
Dimensions
101.6 mm
130 mm
70 mm
1.4 kg
Container Information
box 1 piece
128 mm
135 mm
143 mm
1.47 kg
8015644013226
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 45.5 ... 80 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
4P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 15 W
160 A
50 / 60 Hz
8 kV
1600 A
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
160 A
690 V
Main Circuit M6
TMD
TM
112...160 A
N
IEC60947-2
XT1
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 59.6 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
090e3c3e-b079-4cc9-a4bf-402548b8fa41 Italy
4a007b80-29c3-45ab-9cd3-bc53b4f1afd6 Germany
4ef28cfb-8cbc-4076-8f6c-8681a89cd4b1 Sweden
c8a0a2c7-7065-4a9c-a87b-4191a801a260 Norway
2d49f980-1e49-45b9-a9b6-a81ed6f49d34 Finland
97a47a94-6c3f-4522-a38a-c97acfbddbb5 Netherlands
71452336-1cd5-4f6b-bbfc-25254f6a0173 Germany
d04ee358-6b62-426f-b7f7-33ed790f32f6 Denmark
7bd4d666-c8cb-4355-9ac4-65775fc1f63e Germany
0669be6b-e967-4794-a9ee-a46976dcd3bf Croatia
51c36c5c-af1c-423f-a73d-37dec3e62ee7 Czech Republic
734297d7-06b4-4cb3-abcf-7814faf00771 Poland
6841443d-d808-40bf-9e88-b82488c72978 Netherlands
2ffc7906-a600-4838-b0ff-699435ff21ac Netherlands
42dde5e1-91db-4d65-b45f-85e954e30cbc Estonia
9b70ff78-7e93-4335-b919-04c8edf91d9d Greece
594cfb38-d889-40b1-a9d3-a541822dc3de Portugal
ec550c0e-d709-4a2c-a992-7a283b06bea9 Bulgaria
2ae811e9-7871-48d0-a78e-480033788d4e Sweden
a3e1249b-c9ae-4d32-a01e-98c61bfa4eb5 Poland
31b22010-804b-4527-bde4-6d8929236bc0 France
3a93b966-0634-4c10-bb70-0bfb2c1957b8 Germany
2c438536-e6b4-4e17-9ae7-94e6c8dc92e6 Germany
e04606c2-e869-46b0-bfae-c43dad34ff66 France
5844de9a-f3c9-42c6-9b74-ede8fd543d2e Netherlands
7c8b7b9f-ef73-4d72-99b0-11bc17e05b03 Spain
b9e44577-a0d1-4e50-a6f7-12f5518e32ea Netherlands
b43ce538-523b-4797-8bcf-bed032936dd7 Poland
4a007b80-29c3-45ab-9cd3-bc53b4f1afd6 Germany
4ef28cfb-8cbc-4076-8f6c-8681a89cd4b1 Sweden
c8a0a2c7-7065-4a9c-a87b-4191a801a260 Norway
2d49f980-1e49-45b9-a9b6-a81ed6f49d34 Finland
97a47a94-6c3f-4522-a38a-c97acfbddbb5 Netherlands
71452336-1cd5-4f6b-bbfc-25254f6a0173 Germany
d04ee358-6b62-426f-b7f7-33ed790f32f6 Denmark
7bd4d666-c8cb-4355-9ac4-65775fc1f63e Germany
0669be6b-e967-4794-a9ee-a46976dcd3bf Croatia
51c36c5c-af1c-423f-a73d-37dec3e62ee7 Czech Republic
Environmental
Ordering
XT5NE363BFFF000XXX
3641332
4380254
8056221004367
1 piece
85362090
Dimensions
140 mm
205 mm
103.5 mm
4.82 kg
Container Information
box 1 piece
250 mm
245 mm
285 mm
5.308 kg
8056221004367
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
AC
5000 cycle
60 cycles per hour
5000 cycle
60 cycles per hour
20000 cycle
120 cycles per hour
20000 cycle
120 cycles per hour
3P
1 piece
45 W
630 A
8 kV
1000 V
690 V AC
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
6 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
630 A
Ekip Dip LSI
EL
N
IEC60947-2
XT5
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409


Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644613181
1 piece
85362090
Dimensions
324 mm
461 mm
396.5 mm
49 kg
Container Information
1 piece
515 mm
600 mm
515 mm
59 kg
8015644609139
Additional Information
SACE Emax
Switch Disconnector
Air Circuit Breaker
W
Technical
AC
12000 cycle
30 cycles per hour
12000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
215 W
1600 A
12 kV
1000 V
1600 A
690 V AC
250 V DC
690 V AC
250 V DC
for 1 s 42 kA
for 3 s 42 kA
for 1 s 42 kA
for 3 s 42 kA
1600 A
690 V
B
IEC
E2
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KT5AS-E
8015644557812
1 piece
85389099
Dimensions
0.04 kg
Container Information
1 piece
110 mm
60 mm
140 mm
0.136 kg
8015644557812
Additional Information
Accessories for Tmax T
Accessory
Accessory
T4, T5, T6
SACE Tmax T
Technical
Loose or configurable
2
IEC
Certificates and Declarations
External Classifications and Standards
EC000041 - Auxiliary contact block
EC000041 - Auxiliary contact block
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371302

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644580285
1 piece
85362090
Dimensions
404 mm
418 mm
302 mm
60 kg
Container Information
1 piece
515 mm
600 mm
615 mm
72 kg
8015644580285
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 6000 cycle
Ue = 500 ... 690 V 5000 cycle
20 cycles per hour
Ue =< 440 V 6000 cycle
Ue = 500 ... 690 V 5000 cycle
20 cycles per hour
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
3P
330 W
3200 A
12 kV
1000 V
3200 A
690 V AC
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
for 1 s 85 kA
for 3 s 65 kA
for 1 s 85 kA
for 3 s 65 kA
(220 V AC) 130 kA
(230 V AC) 130 kA
(380 V AC) 130 kA
(400 V AC) 130 kA
(415 V AC) 130 kA
(440 V AC) 130 kA
(500 V AC) 100 kA
(660 V AC) 100 kA
(690 V AC) 100 kA
(220 V AC) 130 kA
(230 V AC) 130 kA
(380 V AC) 130 kA
(400 V AC) 130 kA
(415 V AC) 130 kA
(440 V AC) 130 kA
(500 V AC) 100 kA
(660 V AC) 100 kA
(690 V AC) 100 kA
3200 A
690 V
PR121/P-LI
EL
V
IEC
E3
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXTCRHDEMFP
4381145
8015644697501
1 piece
85389099
Dimensions
0.388 kg
Container Information
box 1 piece
95 mm
106 mm
150 mm
0.4 kg
8015644697501
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT2, XT4
SACE Tmax XT
Technical
Loose or configurable
1 piece
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
3038 >> Handles or knobs
Q
31162801
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370414


Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644571252
1 piece
85362090
Dimensions
414 mm
461 mm
396.5 mm
54 kg
Container Information
1 piece
515 mm
600 mm
615 mm
67 kg
8015644571252
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
4P
378 W
1600 A
12 kV
1000 V
1600 A
690 V AC
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
for 1 s 50 kA
for 3 s 36 kA
for 1 s 50 kA
for 3 s 36 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(380 V AC) 50 kA
(690 V AC) 50 kA
1600 A
690 V
PR121/P-LSI
EL
N
IEC
E1
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)


ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644660321
1 piece
85352100
Dimensions
105 mm
205 mm
103.5 mm
2.35 kg
Container Information
1 piece
248 mm
240 mm
285 mm
2.5 kg
8015644660321
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
3P
at Rated Operating Conditions per Pole 5.2 W
100 A
1150 V AC
1000 V DC
1150 V AC
1000 V DC
(1000 V AC) 12 kA
(415 V AC) 200 kA
(1000 V AC) 20 kA
(415 V AC) 200 kA
(1000 V AC) 20 kA
250 A
TMA
TM
V
IEC
T4
Fixed Circuit-Breakers
Front for Copper Cables
Fixed Circuit-Breakers
Front for Copper Cables
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409


ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 64.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Operation -40 ... 125 °C
Ordering
XT7SE312EUFF000XXX
8056221009140
1 piece
85362090
Dimensions
210 mm
268 mm
166 mm
9.7 kg
Container Information
box 1 piece
280 mm
350 mm
360 mm
11.2 kg
8056221009140
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
AC
3000 cycle
60 cycles per hour
3000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
3P
1 piece
at Rated Operating Conditions per Pole 57 W
1250 A
8 kV
1000 V
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
20 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(240 V AC) 85 kA
(380 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 45 kA
(525 V AC) 45 kA
(690 V AC) 30 kA
1250 A
Ekip Hi-Touch LSIG
EL
S
IEC60947-2
XT7
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z2NTEKBJ200A000000XX
8015644748883
1 piece
85362090
Dimensions
276 mm
371 mm
270 mm
41 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
46 kg
8015644748883
Additional Information
Technical
AC
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
212 W
2000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
2000 A
690 V
Main Circuit M12
Ekip Hi-Touch LSI
EL
N
IEC
E2.2
Yes, 690V
Rear flat Horizontal
Bolt
70 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
Z2BSEJBN200A000000XX
8015644748371
1 piece
85362090
Dimensions
276 mm
371 mm
270 mm
41 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
46 kg
8015644748371
Additional Information
SACE Emax 2
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
136 W
1600 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
100 %
for 1 s 42 kA
for 3 s 42 kA
for 1 s 42 kA
for 3 s 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
1600 A
690 V
Ekip G Touch LSIG
EL
B
IEC
E2.2
Yes, 690V
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644646479
1 piece
85389099
Dimensions
0.2 kg
Container Information
1 piece
105 mm
55 mm
135 mm
0.2 kg
8015644646479
Additional Information
Accessories for Tmax T
Accessory
Accessory
T7, X1
SACE Emax
SACE Tmax T
SACE Emax
SACE Tmax T
Technical
Loose or configurable
1
IEC
Certificates and Declarations
External Classifications and Standards
EC000041 - Auxiliary contact block
EC000041 - Auxiliary contact block
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371302

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT1CE3020AFF000XXX
3638772
4379201
8015644873448
1 piece
85362090
Dimensions
76.2 mm
130 mm
70 mm
1 kg
Container Information
box 1 piece
128 mm
135 mm
143 mm
1.1 kg
8015644873448
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
20 A
8 kV
450 A
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 12.5 kA
(500 V AC) 9 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
(500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA
(230 V AC) 40 kA
(240 V AC) 40 kA
(380 V AC) 25 kA
(415 V AC) 25 kA
(440 V AC) 25 kA
(500 V AC) 18 kA
(525 V AC) 8 kA
(690 V AC) 4 kA
(250 V DC) 2 Poles in Series 25 kA
160 A
690 V
TMD
TM
14...20 A
C
IEC60947-2
XT1
Front
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409


ABB
1SDA054503R1 ABB - T4V250 TMA200-2000 4pFFC1150VAC/DC N100%
Sale price
€1.015,95
Only 1 unit leftABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644556051
1 piece
85352100
Dimensions
140 mm
205 mm
103.5 mm
3.05 kg
Container Information
1 piece
248 mm
240 mm
285 mm
3.5 kg
8015644556051
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
Automatic Circuit Breaker
T4
Moulded Case Circuit Breakers
F
Technical
8000 cycle
120 cycles per hour
8000 cycle
120 cycles per hour
20000 cycle
240 cycles per hour
20000 cycle
240 cycles per hour
4P
at Rated Operating Conditions per Pole 9.9 W
200 A
8 kV
1150 V
1150 V AC
1000 V DC
1150 V AC
1000 V DC
(1000 V AC) 12 kA
(1150 V AC) 6 kA
(1000 V DC) 20 kA
(1000 V AC) 12 kA
(1150 V AC) 6 kA
(1000 V DC) 20 kA
(1000 V AC) 20 kA
(1150 V AC) 12 kA
(1000 V DC) 40 kA
(1000 V AC) 20 kA
(1150 V AC) 12 kA
(1000 V DC) 40 kA
250 A
TMA
TM
V
IEC
T4
Fixed Circuit-Breakers
Front for Copper Cables
Fixed Circuit-Breakers
Front for Copper Cables
3500 V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z2NQEGBD000A000000XX
8015644747749
1 piece
85362090
Dimensions
276 mm
371 mm
270 mm
41 kg
Container Information
box 1 piece
515 mm
610 mm
515 mm
46 kg
8015644747749
Additional Information
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
3P
53 W
1000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
100 %
for 1 s 66 kA
for 3 s 50 kA
for 1 s 66 kA
for 3 s 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
1000 A
690 V
Main Circuit M12
Ekip Touch LI
EL
N
IEC
E2.2
Yes, 690V
Rear flat Horizontal
Bolt
70 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409


ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 77 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Ordering
Z6HXESAC000A000000XX
8015644764630
1 piece
85362090
Dimensions
803 mm
425 mm
383 mm
120 kg
Container Information
box 1 piece
515 mm
610 mm
1000 mm
129 kg
8015644764630
Additional Information
Technical
AC
Ue =< 440 V 3000 cycle
Ue = 500 ... 690 V 2000 cycle
10 cycles per hour
Ue =< 440 V 3000 cycle
Ue = 500 ... 690 V 2000 cycle
10 cycles per hour
12000 cycle
60 cycles per hour
12000 cycle
60 cycles per hour
3P
850 W
5000 A
acc. to IEC 60947-2 12 kV
AC 1000 V
690 V AC
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 100 kA
(690 V AC) 100 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 100 kA
(690 V AC) 100 kA
100 %
for 1 s 100 kA
for 3 s 100 kA
for 1 s 100 kA
for 3 s 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(525 V AC) 100 kA
(690 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(525 V AC) 100 kA
(690 V AC) 100 kA
5000 A
690 V
Ekip Dip LSIG
EL
H
IEC
E6.2
Yes, 690V
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
4926 >> Air circuit breakers
Q
39121615
4. Large Equipment (Any External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
XT2NE4032AFF000XXX
4309739
8015644009403
1 piece
85362090
Dimensions
120 mm
130 mm
82.5 mm
1.6 kg
Container Information
box 1 piece
130 mm
208 mm
145 mm
2.106 kg
8015644009403
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 32.5..100 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
4P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 2.57 W
32 A
50 / 60 Hz
8 kV
320 A
1000 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 20 kA
(690 V AC) 10 kA
(250 V DC) 2 Poles in Series 36 kA
160 A
690 V
Main Circuit M6
TMD
TM
22.4...32 A
N
IEC60947-2
XT2
Front
Bolt
6 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409