I/O CONNECTOR FOR SINAMCIS V90 PROFINET 20-PIN, MDR CONTENT 5 PIECES
SINAMICS G120 Control Unit CU230P-2 PN integrates PROFINET 6 DI, 3 DO, 4 AI, 2 AO 1 motor temperature sensor input 2 PSU-out (10 V DC, 24 V DC) 1 PSU-in (24 V DC) USB and MMC interface Degree of protection IP20
SINAMICS V90, WITH PROFINET INPUT: 3AC 380-480V -15%/+10% 15.8A 45-66HZ OUTPUT: 0-INPUT V 12.6A 0-330HZ MOTOR: 5.0KW PROTECTION: IP20 FRAME SIZE C 140X260X240 (WXHXD)
SINAMICS V90 Input voltage: 380-480 V 3 A -15%/+10% 6.6 A 45-66 Hz Output voltage: 0 – Input 5.3 A 0-330 Hz Motor: 1.5/1.75 kW Degree of protection: IP20 Size B, 100x180x220 (WxHxD)
SINAMICS V20 380-480 V 3AC -15%/+10% 47-6 Rated power 18.5 kW with 150% overload for 60 sec. small output overload: 22 kW with 110% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DQ, 2 AI, 1 AO Fieldbus: USS/Modbus RTU with built-in BOP Degree of protection IP20/UL open Size: Size E 244x265x209
SINAMICS V20 1 AC 200-240 V -10/+10% 47-6 Rated power 1.5 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DQ, Fieldbus: USS/Modbus RTU with built-in BOP protection: IP20/ UL open Size: Size AC 160x90x147(HxWxD)
SINAMICS V20 1 AC 200-240 V -10/+10% 47-6 Rated power 1.1 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DQ, Fieldbus: USS/Modbus RTU with built-in BOP protection: IP20/ UL open Size: Size AC 160x90x147(HxWxD)
SINAMICS V20 200-240 V 1-phase-AC -10/+10 Rated power 0.37 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DQ, 2 AI, 1 AO Fieldbus: USS/Modbus RTU with built-in BOP Degree of protection IP20/UL open Size: Size AA 68x142x108
SINAMICS V20 200-240 V 1-phase-AC -10/+10 Rated power 0.37 kW with 150% overload for 60 sec. Integrated filter C1 I/O interface: 4 DI, 2 DQ, 2 AI, 1 AO Fieldbus: USS/Modbus RTU with built-in BOP Degree of protection IP20/UL open Size: Size AA 68x142x108
SINAMICS V20 200-240 V 1-phase-AC -10/+10 Rated power 0.25 kW with 150% overload for 60 sec. Integrated filter C1 I/O interface: 4 DI, 2 DQ, 2 AI, 1 AO Fieldbus: USS/Modbus RTU with built-in BOP Degree of protection IP20/UL open Size: Size AA 68x142x108 (Wx
SINAMICS G120C RATED POWER 55.0KW WITH 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ INTEGRATED FILTER CLASS A I/O-INTERFACE: 6DI, 2DO, 1AI, 1AO SAFE TORQUE OFF INTEGRATED FIELDBUS: PROFINET-PN PROTECTION: IP20/ UL OPEN TYPE SIZE: FSE 551x 275x 237(HXWXD) EXTERNAL 24V
Sinamics G120C RATED POWER 1,1KW with 150% OVERLOAD FOR 3 SEC 3AC380-480V +10/-20% 47-63HZ Integrated FILTER Class A I/O-INTERFACE: 6DI, 2DO,1AI,1AO SAFE TORQUE OFF Integrated FIELDBUS: USS/ MODBUS RTU PROTECTION: IP20/ UL OPEN TYPE SIZE: FSAA 173X73X155(HXWXD) EXTERNAL 24V
Sinamics LINE REACTOR 380-480V 3AC 47-63HZ I_LN = 11,3A STANDALONE