Filters
Best selling products
24811 products
XUSL type 2 IP69K Hand protection with Heating - Std range - Hp = 910mm, R=30mm
Speed monitoring 1 HTL encoder expansion module with spring term
integrated drive ILS with stepper motor - 24..48 V - Ethernet Powerlink - 3.5 A
integrated drive ILS with stepper motor - 24..48 V - EtherCAT - 5 A
integrated drive ILS with stepper motor - 24..48 V - EtherCAT - 3.5 A
brushless dc motor 24..48 V - Modbus TCP interface - L = 140 mm - w/o gearbox
servo motor BMH - 84 Nm - 3800 rpm - keyed shaft - without brake - IP54
servo motor BMH - 84 Nm - 3800 rpm - keyed shaft - with brake - IP54
servo motor BMH - 8.4 Nm - 6000 rpm - untapped shaft - with brake - IP65/IP67
servo motor BMH - 6.2 Nm - 6000 rpm - untapped shaft - without brake - IP54
servo motor BMH - 3.3 Nm - 6000 rpm - untapped shaft - without brake - IP65/IP67
SIMATIC PCS 7 Redundancy AS pre-mounted and checked; Without memory card With 2 x CPU 414 H incl. AS RT PO 100)) With 2 x 2 10 m sync module and 2 x 1 m FOC With 2 x CP443-1 IE/PN With 1 x UR2-H (2 x 9 slots) Aluminum rack With 2 x 24 V DC 10 A Power supply Bundle Release F: Without IL Runtime License Without additional I/O connection
Simatic WinCC RT Prof. V14 SP1, Upgrade WinCC V7.0..V7.3 RT 262144 Powertags -> WinCC RT Professional 262144 Powertags V14 SP1, Runtime-SW in the Tia Portal, Single License, SW And Documentation on DVD, License Key on USB Stick, Class A, 6 Languages(Ge,En,It,Fr,Sp,Ch), Executable Under Windows 7 Prof/Ent/Ult SP1 (32/64 bit)/ 10 Prof/Ent (64 bit)/ 8.1 Pro/Ent (64 bit)/ Server2008 R2 +SP1 (64 bit)/ Server 2012 R2 / 2016 (64 bit)/
circuit breaker VL1250L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection trip unit ETU10, LI In=1250A, rated current IR=500...1250A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact
circuit breaker VL1250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=1250A, rated current IR=500...1250A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact
circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit LCD ETU40, LI/LS/LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2463-6JP42-....
circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection trip unit ETU20, LSI In=630A, rated current IR=252...630A, overload protection, ISD=1.5 to 9xIR, II=10xIN short-circuit protection N protected without auxiliary release ETU communication-capable without auxiliary/alarm switch Notes Sucessor:3VA2463-5JP42-0A..
circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit TM, LI In=500A, rated current IR=400...500A, overload protection, II=2500...5000A, short-circuit protection N protected without auxiliary release without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact
circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU20, LSI In=250A, rated current IR=100...250A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2225-6HN32-0A..
circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU20, LSI In=63A, rated current IR=25...63A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2163-5HN46-0A..
circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=100A, rated current II=1800A, short-circuit prot. without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA1110-1AA46-....
circuit breaker 3VA6 UL frame 400 breaking capacity class L 150kA @ 480V 3-pole, line protection ETU830, LIG, In=250A overload protection Ir=100A...250A short-circuit protection Ii=1.5...12 x In ground-fault protection Ig=0.2...1 x In, tg=0.05-0.8s without connection
circuit breaker 3VA6 UL frame 400 breaking capacity class C 100kA @ 480V 3-pole, line protection ETU560, LSIG, In=400A overload protection Ir=160A...400A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% ground-fault protection Ig=0.2...1 x In, tg=0.05-0.8s without connection
circuit breaker 3VA6 UL frame 250 breaking capacity class L 150kA @ 480V 3-pole, line protection ETU556, LSI, In=250A overload protection Ir=100A...250A short-circuit protection Isd=0.6..10x In, Ii=1.5..10x In N conductor protection optionally with external current transformer, up to 160% ground-fault alarm message via EFB300 or COM without connection
Filters