Filters
Siemens PLCs
52013 products
That’s why we at PLC Direct always set out to keep a diverse set of Siemens PLC hardware in stock. We especially stand by the brand’s PLC Siemens Simatic models for their commitment to customizability and constant improvability. Even if you require obsolete Siemens PLC parts or need a new PLC altogether, our selection of Siemens PLCs is exactly what you should seek out. Browse our collection below to assess this product’s availability and find something that works for your equipment. Once you find the right match, we can even get it to you without the unnecessary lead times. Shop here to learn more.
circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor unprotected clamp connection
circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A...125A short-circuit protection Ii=10 x In N conductor protection 100% clamp connection
circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI Ir=25...63A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch Notes Sucessor:3VA2163-5MQ36-0A..
circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=160A overload protection Ir=160A fixed short-circuit protection Ii=10 x In N conductor protection 100% nut keeper kit
circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=160A overload protection Ir=160A fixed short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit
circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 4-pole, line protection TM210, FTFM, In=160A overload protection Ir=160A fixed short-circuit protection Ii=10 x In N conductor protection 50% nut keeper kit
circuit breaker 3VA2 IEC frame 100 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In clamp connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection ETU350, LSI, In=100A overload protection Ir=40A...100A short-circuit protection Isd=1.5...10 x Ir, Ii=12 x In clamp connection
circuit breaker 3VA2 IEC frame 160 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection
circuit breaker 3VA2 IEC frame 100 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=100A overload protection Ir=40A...100A short-circuit protection Ii=1.5...12 x In clamp connection
Simatic S7,Easy Motion Ctrl 2.1 Single License F.1 Installation R-SW, SW And Docu. on CD, Class A, 2 Languages (G,E), Executable Under Step7 from V5.3 SP2, Reference-Hw: Simatic S7-300/400/Winac
SIMATIC WINCC RUNTIME ADVANCED 128 POWERTAGS V14, RUNTIME SOFTWARE IN TIA PORTAL; SINGLE LICENSE; SOFTWARE AND DOCUMENTATION ON DVD; LICENSE KEY ON USB STICK; CLASS A; 6 LANGUAGES: GE,EN,IT,FR,ES,ZN; EXECUTABLE UNDER WINDOWS 7 (32 BIT, 64 BIT), WINDOWS 8.1 (64 BIT), WINSRV 2008/2012 R2 (64 BIT)
circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=100A, rated current IR=40...100A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2110-7MN36-0A..
circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=63A, rated current IR=25...63A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch Notes Sucessor:3VA2163-7MQ36-0A..
circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 4-pole, non-auto. air circ. br. Electronic Trip Unit magnetic In=160A, rated current II=1800A, short-circuit prot. without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA1116-1AA46-....
circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=100A, rated current IR=40...100A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch Notes Sucessor:3VA2110-5MQ36-0A..
circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=25A without overload protection short-circuit protection Ii=3...15 x In without connection
circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=30A without overload protection short-circuit protection Ii=3...15 x In without connection
circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=40A without overload protection short-circuit protection Ii=3...15 x In without connection
circuit breaker 3VA6 UL frame 150 3-pole, starter protection ETU310M, I, In=50A without overload protection short-circuit protection Ii=3...15 x In without connection
accessories circuit breaker 3WL locking device against traversing of circ. breaker safety lock at crank hole kirk-key mount. set
SIPLUS ET 200SP -25 ... +60 DEGREE WITH CONFORMAL COATING BASEDON 6ES7136-6DB00-0CA0 . ELECTRONIC MODULE, 4 F-DQ PROFISAFE, DC 24V/2A, 15 MM WIDTH, UP TO PL E (ISO 13849), UP TO SIL 3 (IEC 61508)
accessories circuit breaker 3WL locking device f. Insert against Unauth. switching on w. lock In cabinet door and locking component effective In operating pos. make: profalux
circuit breaker 3VT1 standard breaking capacity Icu=25kA, 415V AC 3-pole, line protection trip unit TM, LI In=160A rated current IR=160A overload protection II=640A, short-circuit prot. without auxiliary release without auxiliary/alarm switch Notes Sucessor:Further information about local contact: www.siemens.com/lowvoltage/contact