Specifications
Model |
OP-83181 |
|||
Type |
Deadspace-free Bracket |
|||
Applicable product |
SL-C, SL-V |
|||
Number included |
2 pcs. |
|||
Material |
SUS304 |
|||
Note |
Holding sensor main body from the side. |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
IV-M30 |
|||
Supported languages |
Japanese/English |
|||
Display |
3.5" TFT color LCD 320 x 240 dot (QVGA) |
|||
Backlight |
Method |
White LED |
||
Duration |
Approx. 50,000 hours (25 °C 77 °F) |
|||
Touch panel |
Method |
Analog resistive |
||
Actuating force |
0.8 N or less |
|||
Indicators |
PWR, SENSOR |
|||
Ethernet |
Standard |
100BASE-TX/10BASE-T*1 |
||
Connector |
M12 4pin connector*1 |
|||
Expanded memory |
USB memory*2 |
|||
Rating |
Power voltage |
24 VDC ±10 % (including ripple) |
||
Current consumption |
0.2 A or less |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 80 % RH (No condensation)*3 |
|||
Drop Resistance |
1.3 m 4.27' over the concrete (2 times each in the arbitrary direction) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 180 g |
|||
*1 This is dedicated for connection with IV-series sensor. | ||||



Specifications
Model |
PR-MB15CN |
|||
Type |
Reflective (Background suppression) |
|||
Output |
NPN |
|||
Shape |
Mini-slim |
|||
Cable connection |
M8 connector (4 pin) |
|||
Detection distance |
1 to 15 mm 0.04" to 0.59" |
|||
Number of control outputs |
2 |
|||
Output operation |
Output 1 |
Light-ON |
||
Output 2 |
Dark-ON |
|||
Response time |
Output 1 |
0.5 ms |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. ø3 mm (at 15 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 % |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 13 g |
|||

Specifications
Model |
CA-H048CX |
|||
Image element |
Color CMOS, 16× high-speed reading using square-pixel |
|||
Unit cell size |
4.8 µm × 4.8 µm 0.19 Mil × 0.19 Mil |
|||
Valid pixel count |
0.47 megapixel mode: 784 (H) × 596 (V), 0.31 megapixel mode: 640 (H) × 480 (V), 0.24 megapixel mode: 512 (H) × 480 (V) |
|||
Image size |
Equivalent to 1/3" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
195 MHz |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.022 to 1000 msec by specifying the following numerical inputs: |
|||
Lens mount |
C-mount |
|||
Environmental resistance |
Ambient temperature |
0 to 40°C 32 to 104°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 190 g (not including lens) |
|||

Specifications
Model |
GV-21P |
|||
Type |
Amplifier Unit, Main Unit |
|||
Power consumption |
Normal |
2200 mW max. (at 30 V: 73.3 mA max.) |
||
Eco-Half |
1700 mW max. (at 30 V: 56.7 mA max.) |
|||
Eco-All |
1600 mW max. (at 30 V: 53.3 mA max.) |
|||
Display indicator |
Dual 7-segment display (Current Value: 3-digit red LED indicator, Preset Value: 3-digit green LED indicator) |
|||
Output |
PNP |
|||
Control output |
PNP open collector x 2ch, 30 V DC max./Max. 100 mA, residual voltage 1 V max. |
|||
Control input |
Emission stop input, Bank switching input, Shift input, Timing input, Each input response time: 20 ms |
|||
Response time |
1.5/3/10/20/50 ms |
|||
Operation status indicators |
Control output: Red LED x 2 Channel display: Green LED x 2 Laser radiation emission indicator |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 %*1 |
||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing material, display cover: Polycarbonate, Key Top: Polyacetal, Cable: PVC |
|||
Weight |
Approx. 110 g |
|||
*1 If expansion units are added, supply voltage must be 11 to 30 VDC. | ||||

Specifications
Model |
ED-118M |
|||
Type |
Shielded |
|||
Shape |
M18Threaded type |
|||
Detecting distance |
5 mm 0.20" ±15% |
|||
Detectable object |
All metals *1 |
|||
Standard target (aluminum, t=1 mm 0.04") |
18 x 18 mm 0.71" x 0.71" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
100 Hz |
|||
Operation mode |
N.O. |
|||
Indicator lamp |
Operation indicator: Red LED, Stable operation indicator: Green LED |
|||
Temperature characteristics |
±20% max. of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
35 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 150 g (including 2-m 6.6' cable and nuts) |
|||
*1 When detecting ferrous metals, the detecting distance may decrease. | ||||

Specifications
Model |
GL-VB03 |
|||
Number included |
Mounting bracket: 2 |
|||
Material |
Mounting bracket: SUS304 |
|||
Weight |
50 g 1.76 oz *1 |
|||
*1 GL-V Mounting includes two mounting brackets. The weight stated is for both items. | ||||

Specifications
Model |
CL-V050 *1 |
|||
Type |
Sensor head (50 mm vacuum and heatresistant model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-86H*1 |
|||
Optical axis diameter |
ø1.5 mm0.059" |
|||
Heat resistant temperature |
150°C 302°F*2*3 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R20 mm0.787" |
|||
Minimum detectable object |
Object with a diameter of 0.005 mm0.0002"*4 |
|||
Environmental resistance |
Ambient temperature |
-40 to +150 °C -40 to 302 °F |
||
Weight |
Approx. 35 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
CL-L030N |
|||
Type |
Optical unit |
|||
Head |
CL-L030 *1 |
|||
Reference distance |
30 mm 1.18" |
|||
Reference measurement range |
Measurement range |
±3.7 mm ±0.15" |
||
Linearity |
±0.94 μm ±0.000037" *2 |
|||
High precision measurement range |
Measurement range |
±1.0 mm ±0.04" |
||
Linearity |
±0.72 μm ±0.000028" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø500 μm ø0.0197" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 200 g 7.06 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
VH-ZST |
|||
Magnification |
20 x, 100 x, 200 x, 500 x, 1000 x, 2000 x*1 |
|||
Field-of-view |
Horizontal |
20 x: 15240 µm |
||
Vertical |
20 x: 11400 µm |
|||
Diagonal |
20 x: 19050 µm |
|||
Working distance |
15 mm 0.59" |
|||
*1 Magnification on a 15-inch monitor with a 1/2-inch camera. | ||||

Specifications
Model |
OP-42218 |
|||
Type |
Replacement filters for the electrode cleaning kit |
|||
Number included |
10 |
|||

Specifications
Model |
OP-92737 |
|||
Type |
Adapter |
|||
Overview |
When using FS2-60/62/65, this adapter and fixing ring are necessary to mount fiber unit. |
|||
Applicable product |
Fiber unit with cable outer diameter ø1.0 (Free-cut) |
|||
Note |
Attached to the amplifier. Please purchase when additionally necessary. |
|||

Specifications
Model |
FU-38*1 |
|||
Beam emitting direction |
Flat |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 5 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
EA-300 |
|||
Analysis optical system |
Detection principle |
Laser-induced breakdown spectroscopy |
||
Supported elements |
H1 to U92 |
|||
Laser |
Laser type |
Nd: YAG laser |
||
Laser class |
Class 1 laser product (IEC/EN 60825-1, JIS C 6802, FDA (CDRH) Part 1040.10) |
|||
Laser wavelength |
355 nm |
|||
Spot size |
10 μm (typ.) |
|||
Observation optical system |
Image sensor |
1/1.8-inch, 3.19-megapixel CMOS image sensor |
||
Observation magnification |
300× to 1000× |
|||
Scanning system |
Progressive |
|||
Frame rate |
50 fps (max.) |
|||
Optical system |
Lens type |
Specially designed reflective objective lens |
||
Objective lens working distance |
25 mm 0.98" |
|||
High dynamic range |
16-bit intensity range through RGB data from each pixel |
|||
Gain |
Manual, Preset |
|||
Electronic shutter |
Auto, Manual, 1/60, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/5000, 1/9000, 1/19000 |
|||
Supercharge shutter |
Can be set in 0.01 s increments from 0.02 to 16 s |
|||
White balance |
Push-set, Manual, Preset (2700K, 3200K, 5600K, 9000K) |
|||
Built-in coaxial illumination light source |
Type |
High-brightness LED |
||
Service life |
100000 hours (reference value) |
|||
Color temperature |
5810K (typ.) |
|||
Built-in ring illumination light source |
Type |
High-brightness LED |
||
Service life |
100000 hours (reference value) |
|||
Color temperature |
5810K (typ.) |
|||
Power supply |
Power supply method |
Power supplied via dedicated cable from VHX Series controller camera port |
||
Environmental resistance |
Ambient temperature |
10 to 33°C 50.0°F to 91.4°F |
||
Relative humidity |
35 to 80% RH (No condensation) |
|||
Dimensions |
280 (W) × 375 (H) × 210 (D) mm 11.02"(W) × 14.76" (H) × 8.27" (D) (with lens stored) (excluding protrusions) |
|||
Weight |
Approx. 7.2 kg 15.87 lb (Analysis system main unit) |
|||

Specifications
Model |
GS-51PCSO(3195) |
|||
Lock type |
Power-to-release type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
220 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||