keyence Stock Image
Keyence AP-C31K Keyence
Sale price 4,575.00 kr
Only 4 units left

Specifications

Model

AP-C31K

Type

Negative pressure, NPN

Rated pressure

0 to -29.9 inchHg

Fluid type

Air or non-corrosive gases

Type of pressure

Gauge pressure

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Display resolution

Normal mode: 0.1 inchHg, Focus mode: 0.01 inchHg

Power consumption

Normal

12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less

Eco mode

12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of F.S.)*1

Response time (Chattering prevention function)

2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

Pressure port

NPT 1/8 180 ° rotation

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Pressure resistance

500 kPa

Ambient temperature

0 to 50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting

Accessories

Power supply cord (6.6' 2-m with connector)

Weight

Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable)

*1 A standard of 0.2 % of FS applies while in focus mode.

keyence Stock Image
Keyence AP-C31KP Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

AP-C31KP

Type

Negative pressure, PNP

Rated pressure

0 to -29.9 inchHg

Fluid type

Air or non-corrosive gases

Type of pressure

Gauge pressure

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Display resolution

Normal mode: 0.1 inchHg, Focus mode: 0.01 inchHg

Power consumption

Normal

12 V: 900 mW (75 mA) or less, 24 V: 1,320 mW (55 mA) or less

Eco mode

12 V: 600 mW (50 mA) or less, 24 V: 960 mW (40 mA) or less

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of F.S.)*1

Response time (Chattering prevention function)

2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

PNP open collector 100 mA max. (at 30 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

Pressure port

NPT 1/8 180 ° rotation

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Pressure resistance

500 kPa

Ambient temperature

0 to 50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting

Accessories

Power supply cord (6.6' 2-m with connector)

Weight

Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable)

*1 A standard of 0.2 % of FS applies while in focus mode.

Keyence Stock Image
Keyence AP-C31P Keyence
Sale price 2,933.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence AP-C31WP Keyence
Sale price 3,223.00 kr
Only 3 units left
Buy the Keyence AP-C31WP - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence AP-C31WP is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence Stock Image
Keyence AP-C33C Keyence
Sale price 5,577.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence AP-C33CP Keyence
Sale price 4,788.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence AP-C33K Keyence
Sale price 3,889.00 kr
Only 1 unit left

Specifications

Model

AP-C33K

Type

Positive pressure, NPN

Rated pressure

0 to 145.0 Psi

Fluid type

Air or non-corrosive gases

Type of pressure

Gauge pressure

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Display resolution

Normal mode: 0.2 Psi, Focus mode: 0.02 Psi

Power consumption

Normal

12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less

Eco mode

12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of F.S.)*1

Response time (Chattering prevention function)

2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

Pressure port

NPT 1/8 180 ° rotation

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Pressure resistance

1.5 MPa

Ambient temperature

0 to 50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting

Accessories

Power supply cord (6.6' 2-m with connector), Unit seal

Weight

Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable)

*1 A standard of 0.2 % of FS applies while in focus mode.

Keyence Stock Image
Keyence AP-C33KP Keyence
Sale price 4,231.00 kr
Only 6 units left

Specifications

Model

AP-C33KP

Type

Positive pressure, PNP

Rated pressure

0 to 145.0 Psi

Fluid type

Air or non-corrosive gases

Type of pressure

Gauge pressure

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Display resolution

Normal mode: 0.2 Psi, Focus mode: 0.02 Psi

Power consumption

Normal

12 V: 900 mW (75 mA) or less, 24 V: 1,320 mW (55 mA) or less

Eco mode

12 V: 600 mW (50 mA) or less, 24 V: 960 mW (40 mA) or less

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of F.S.)*1

Response time (Chattering prevention function)

2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

PNP open collector 100 mA max. (at 30 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable)

Pressure port

NPT 1/8 180 ° rotation

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Pressure resistance

1.5 MPa

Ambient temperature

0 to 50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting

Accessories

Power supply cord (6.6' 2-m with connector), Unit seal

Weight

Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable)

*1 A standard of 0.2 % of FS applies while in focus mode.

Keyence Stock Image
Keyence AP-C33P Keyence
Sale price 3,931.00 kr
Only 5 units left
Buy the Keyence AP-C33P - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence AP-C33P is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence Stock Image
Keyence AP-C33PFAST Keyence
Sale price 3,043.00 kr
Only 5 units left
Buy the Keyence AP-C33PFAST - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence AP-C33PFAST is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence Stock Image
Keyence AP-C33W Keyence
Sale price0.00 kr
Sold Out
Buy the Keyence AP-C33W - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence AP-C33W is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence Stock Image
Keyence AP-C33WP Keyence
Sale price 3,854.00 kr
Only 8 units left
Buy the Keyence AP-C33WP - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence AP-C33WP is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence AP-C35 Keyence
Sale price 4,109.00 kr
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence AP-C40P Keyence
Sale price 3,516.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence AP-C40W Keyence
Sale price 2,931.00 kr
Only 1 unit left

Specifications

Model

AP-C40W

Type

Amplifier Unit, NPN

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44

Set and display range

-15 to +110 % of F.S.*1

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg
AP-43: Standard mode 0.01 kgf/cm2, High-resolution/Focus mode 0.02 Psi

Power consumption

Normal

12 V: 780 mW (65 mA) max., 24 V: 1,080 mW (45 mA) max.

Eco mode

12 V: 540 mW (45 mA) max., 24 V: 840 mW (35 mA) max.

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.)

Response time (Chattering prevention function)

1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

NPN open collector 100 mA max. (at 40 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate

Accessories

Power supply code (2-m 6.6' cable with connector), Head connector, and Unit seal

Weight

Approx. 74 g (with 2-m 6.6' cable)

*1 The focus range applies while in focus mode only.

keyence Stock Image
Keyence AP-C40WP Keyence
Sale price 3,217.00 kr
Only 3 units left

Specifications

Model

AP-C40WP

Type

Amplifier Unit, PNP

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44

Set and display range

-15 to +110 % of F.S.*1

Display

3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43"), Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg
AP-43: Standard mode 0.01 kgf/cm2, High-resolution/Focus mode 0.02 Psi

Power consumption

Normal

12 V: 960 mW (80 mA) max., 24 V: 1,400 mW (60 mA) max.

Eco mode

12 V: 660 mW (55 mA) max., 24 V: 1,080 mW (45 mA) max.

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.)

Response time (Chattering prevention function)

1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

PNP open collector 100 mA max. (at 30 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate

Accessories

Power supply code (2-m 6.6' cable with connector), Head connector, and Unit seal

Weight

Approx. 74 g (with 2-m 6.6' cable)

*1 The focus range applies while in focus mode only.

keyence Stock Image
Keyence AP-N10 Keyence
Sale price 4,989.00 kr
Only 1 unit left

Specifications

Model

AP-N10

Type

Single output type

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44, AP-48

Configuration/Display range

-15 to +110 % of F.S.

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa
AP-43: Standard mode 0.001 MPa, High resolution mode 0.1 kPa

Power consumption

Normal

770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less)

Eco mode

560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less)

Expansion units

Max. 16 units (Dual output type is counted as 2 units.)*1

Control output(s)

1*2

Display temperature characteristic

±1 % of F.S. (When the temperature varies from 25 °C 77 °F)

Response time (Chattering prevention function)

1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Main unit and cover: Polycarbonate

Weight

Approx. 20 g

*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers.
*2 Number of outputs when connected to the communication unit NU Series. There are no control output wires.
*3 11 to 16 units connected: 0 to +45 °C 32 to 113 °F (When the sensor amplifier is installed on DIN rail on a metal plate)

keyence Stock Image
Keyence AP-N10D Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

AP-N10D

Type

Dual output type

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44, AP-48

Configuration/Display range

-15 to +110 % of F.S.

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa
AP-43: Standard mode 0.001 MPa, High resolution mode 0.1 kPa

Power consumption

Normal

770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less)

Eco mode

560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less)

Expansion units

Max. 16 units (Dual output type is counted as 2 units.)*1

Control output(s)

2*2

Display temperature characteristic

±1 % of F.S. (When the temperature varies from 25 °C 77 °F)

Response time (Chattering prevention function)

1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Main unit and cover: Polycarbonate

Weight

Approx. 20 g

*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers.
*2 Number of outputs when connected to the communication unit NU Series. There are no control output wires.
*3 11 to 16 units connected: 0 to +45 °C 32 to 113 °F (When the sensor amplifier is installed on DIN rail on a metal plate)

Keyence Stock Image
Keyence AP-V41A Keyence
Sale price 7,705.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence AP-V41AW Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

AP-V41AW

Type

Amplifier Unit, NPN

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44

Set and display range

-15 to +110 % of F.S.*1

Display

4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green), Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg
AP-43: Standard mode 0.01 kgf/cm2, High-resolution/Focus mode 0.02 Psi

Power consumption

Normal

12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max.

Eco mode

12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max.

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.)

Response time (Chattering prevention function)

1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

NPN open collector 100 mA max. (at 40 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Accessories

Mounting bracket, Head connector

Weight

Approx. 80 g (with 2-m 6.6' cable)

*1 The focus range applies while in focus mode only.

keyence Stock Image
Keyence AP-V41AWP Keyence
Sale price 3,895.00 kr
Only 2 units left

Specifications

Model

AP-V41AWP

Type

Amplifier Unit, PNP

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44

Set and display range

-15 to +110 % of F.S.*1

Display

4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green), Display cycle: 10 times/s

Operation indicator

Red LED x 2 (corresponding to control output 1 and 2)

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg
AP-43: Standard mode 0.01 kgf/cm2, High-resolution/Focus mode 0.02 Psi

Power consumption

Normal

12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max.

Eco mode

12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max.

Display temperature characteristic

±1 % of F.S. max.

Hysteresis

Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.)

Response time (Chattering prevention function)

1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable)

I/O

Analog output

1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable)

Zero-shift input

Input time: 2 ms or more. (or analog output selectable)

Control output

PNP open collector 100 mA max. (at 30 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Accessories

Mounting bracket, Head connector

Weight

Approx. 80 g (with 2-m 6.6' cable)

*1 The focus range applies while in focus mode only.

Keyence Stock Image
Keyence AP-V41W Keyence
Sale price 4,776.00 kr
Only 3 units left

Specifications

Model

AP-V41W

Type

Amplifier Unit, NPN

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44

Display

4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green) Display cycle: 10 times/s

Operation indicator

Red LED × 2 (corresponding to control output 1 and control output 2)

Display resolution

AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg
AP-43: Standard mode 0.01 kgf/cm2, High-resolution/Focus mode 0.02 Psi

Power consumption

Normal

12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max.

Eco mode

12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max.

Display temperature characteristic

±1 % of F.S. or less

Hysteresis

Standard mode: 0.5 % of F.S., high-resolution mode: 0.1 % of F.S., hysteresis variable mode (F-2): variable

Response time (Chattering prevention function)

1/2.5/5/100/500 ms (selectable; 1 ms is used when high-speed mode is selected)

I/O

Analog output

1 to 5 V, output impedance: 1 kΩ or less (switchable with zero shift input)

Zero-shift input

Input time: 2 ms or more (switchable with analog output)

Control output

Maximum NPN open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)*1

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Accessories

Mounting bracket, head connection connector

Weight

Approx. 80 g (with 2 m cable)

*1 20 mA or less when extended

Keyence Stock Image
Keyence AP-V41WP Keyence
Sale price 8,810.00 kr
Only 2 units left

Specifications

Model

AP-V41WP

Type

Amplifier Unit, PNP

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44

Display

4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green) Display cycle: 10 times/s

Operation indicator

Red LED × 2 (corresponding to control output 1 and control output 2)

Display resolution

AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg
AP-43: Standard mode 0.01 kgf/cm2, High-resolution/Focus mode 0.02 Psi

Power consumption

Normal

12 V: 840 mW (70 mA) max., 24 V: 1,200 mW (50 mA) max.

Eco mode

12 V: 600 mW (50 mA) max., 24 V: 960 mW (40 mA) max.

Display temperature characteristic

±1 % of F.S. or less

Hysteresis

Standard mode: 0.5 % of F.S., high-resolution mode: 0.1 % of F.S., hysteresis variable mode (F-2): variable

Response time (Chattering prevention function)

1/2.5/5/100/500 ms (selectable; 1 ms is used when high-speed mode is selected)

I/O

Analog output

1 to 5 V, output impedance: 1 kΩ or less (switchable with zero shift input)

Zero-shift input

Input time: 2 ms or more (switchable with analog output)

Control output

Maximum PNP open-collector output: 100 mA (30 V or less), residual voltage: 1 V or less, 2 outputs (N.O./N.C. switchable)*1

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Polycarbonate

Accessories

Mounting bracket, head connection connector

Weight

Approx. 80 g (with 2 m cable)