Specifications
Model |
TH-515 |
|||
Type |
Detecting large metallic objects |
|||
Minimum detectable object |
5.0 mm |
|||
Detecting area |
100 x 150 mm |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 1.3 kg |
|||
*1 Data obtained with the amplifi er set at maximum sensitivity when target was travelling at 500 mm 19.69". | ||||

Specifications
Model |
TH-520 |
|||
Type |
Detecting large metallic objects |
|||
Minimum detectable object |
7.0 mm |
|||
Detecting area |
150 x 200 mm |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 2.1 kg |
|||
*1 Data obtained with the amplifi er set at maximum sensitivity when target was travelling at 500 mm 19.69". | ||||

Specifications
Model |
TM-006 |
|||
Measuring range |
ø6 mm 0.24" |
|||
Minimum detectable object |
0.04 mm 0.001" |
|||
Transmitter/receiver distance |
60 mm 2.36" |
|||
Light source |
GaN Green LED |
|||
Measurement accuracy |
±0.5 µm ±0.000020" *1 |
|||
Repeatability |
±0.06 µm*2 |
|||
Sampling cycle (trigger interval) |
5.5ms (33ms at the initial setting)*3 |
|||
Environmental resistance |
Enclosure rating |
IP64*4 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter |
Approx 140 g |
||
Receiver |
Approx 340 g |
|||
Base |
Approx 220 g |
|||
*1 In a measurement area of 2 mm 0.08"× ø4 mm ø0.16" error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
TM-040 |
|||
Measuring range |
ø40 mm 1.57" |
|||
Minimum detectable object |
0.3 mm 0.01" |
|||
Transmitter/receiver distance |
180 mm 7.09" |
|||
Light source |
InGaN Green LED |
|||
Measurement accuracy |
±2 µm 0.000079" *1 |
|||
Repeatability |
±0.15 µm ±0.000006" *2 |
|||
Sampling cycle (trigger interval) |
5.5ms (33ms at the initial setting)*3 |
|||
Environmental resistance |
Enclosure rating |
IP64*4 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter |
Approx 560 g |
||
Receiver |
Approx 720 g |
|||
Base |
Approx 630 g |
|||
*1 In a measurement area of 10 mm 0.39"× ø26 mm ø1.02" error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
TM-065 |
|||
Measuring range |
ø65 mm 2.56" |
|||
Minimum detectable object |
0.5 mm 0.02" |
|||
Transmitter/receiver distance |
270 mm 10.63" |
|||
Light source |
InGaN Green LED |
|||
Measurement accuracy |
±3 µm ±0.000119"*1 |
|||
Repeatability |
±0.2 µm 0.000008" *2 |
|||
Sampling cycle (trigger interval) |
5.5ms (33ms at the initial setting)*3 |
|||
Environmental resistance |
Enclosure rating |
IP64*4 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter |
Approx 1280 g |
||
Receiver |
Approx 1460 g |
|||
Base |
Approx 1500 g |
|||
*1 Error when measuring width of KEYENCE standard object (glass calibration scale) in a measurement area of 20 mm 0.79"× ø40 mm ø1.57". | ||||

Specifications
Model |
TM-3000 |
|||
Head compatibility |
Compatible |
|||
Number of connectable sensors |
2 units max.*1 |
|||
Display |
Minimum display unit |
0.01 µm, 0.001 mm2, 0.01 ° |
||
Maximum display range |
±9999.99 mm ±393.7", ±99999.9 mm2, ±99999.9° |
|||
Input terminal block |
Laser remote interlock input |
Non-voltage input*2 |
||
Trigger input (for Head A) | ||||
Timing 1 input | ||||
Auto-zero 1 input | ||||
Reset input | ||||
Output terminal block |
Analog voltage output |
±10 V x 2 outputs, out put impedance: 100 Ω*2 |
||
Total judgment output |
NPN open-collector output*2 |
|||
Error output |
NPN open-collector output (N.C.)*2 |
|||
Process output |
NPN open-collector output*2 |
|||
Trigger input enable output | ||||
Adjusted error output | ||||
Expansion connector |
Trigger input (for Head A) |
Non-voltage input*2 |
||
Timing 2 input | ||||
Auto-zero 2 input | ||||
Program switching input |
Non-voltage input, 4 inputs*2 |
|||
Memory card save input |
Non-voltage input*2 |
|||
Judgment/Binary output |
3-level judgment output: OUT1 to OUT16, total judgment output |
|||
Strobe output |
NPN open-collector output*2 |
|||
Trigger input enable output | ||||
Analog RGB monitor output |
SVGA (800 x 600 pixels) |
|||
RS-232C interface |
Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable) |
|||
USB interface |
In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible) |
|||
Ethernet interface |
1000BASE-T/1000 BASE-TX/10 BASE-T |
|||
Memory card |
SD card CA-SD4G (4GB), CA-SD1G (1GB) support |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption. |
1 head connected 480mA max./ 2 heads connected 550mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1,120 g |
|||
*1 1 or 2 units can be connected only with the same head model | ||||

Specifications
Model |
TM-3001 |
|||
Head compatibility |
Compatible |
|||
Number of connectable sensors |
2 units max.*1 |
|||
Display |
Minimum display unit |
0.01 µm, 0.001 mm2, 0.01 ° |
||
Maximum display range |
±9999.99 mm ±393.7", ±99999.9 mm2, ±99999.9° |
|||
Input terminal block |
Laser remote interlock input |
Non-voltage input*2 |
||
Trigger input (for Head A) | ||||
Timing 1 input | ||||
Auto-zero 1 input | ||||
Reset input | ||||
Output terminal block |
Analog voltage output |
±10 V x 2 outputs, out put impedance: 100 Ω*2 |
||
Total judgment output |
NPN open-collector output*2 |
|||
Error output |
NPN open-collector output (N.C.)*2 |
|||
Process output |
NPN open-collector output*2 |
|||
Trigger input enable output | ||||
Adjusted error output | ||||
Expansion connector |
Trigger input (for Head A) |
Non-voltage input*2 |
||
Timing 2 input | ||||
Auto-zero 2 input | ||||
Program switching input |
Non-voltage input, 4 inputs*2 |
|||
Memory card save input |
Non-voltage input*2 |
|||
Judgment/Binary output |
3-level judgment output: OUT1 to OUT16, total judgment output |
|||
Strobe output |
NPN open-collector output*2 |
|||
Trigger input enable output | ||||
Analog RGB monitor output |
SVGA (800 x 600 pixels) |
|||
RS-232C interface |
Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable) |
|||
USB interface |
In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible) |
|||
Ethernet interface |
1000BASE-T/1000 BASE-TX/10 BASE-T |
|||
Memory card |
SD card CA-SD4G (4GB), CA-SD1G (1GB) support |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption. |
1 head connected 480mA max./ 2 heads connected 550mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1,120 g |
|||
*1 1 or 2 units can be connected only with the same head model | ||||

Specifications
Model |
TM-3001P |
|||
Head compatibility |
Compatible |
|||
Number of connectable sensors |
2 units max.*1 |
|||
Display |
Minimum display unit |
0.01 µm, 0.001 mm2, 0.01 ° |
||
Maximum display range |
±9999.99 mm ±393.7", ±99999.9 mm2, ±99999.9° |
|||
Input terminal block |
Laser remote interlock input |
Non-voltage input*2 |
||
Trigger input (for Head A) |
Voltage input*2 |
|||
Timing 1 input | ||||
Auto-zero 1 input | ||||
Reset input | ||||
Output terminal block |
Analog voltage output |
±10 V x 2 outputs, out put impedance: 100 Ω*2 |
||
Total judgment output |
PNP open-collector output*2 |
|||
Error output |
PNP open-collector output (N.C.)*2 |
|||
Process output |
PNP open-collector output*2 |
|||
Trigger input enable output | ||||
Adjusted error output | ||||
Expansion connector |
Trigger input (for Head A) |
Voltage input*2 |
||
Timing 2 input | ||||
Auto-zero 2 input | ||||
Program switching input |
Voltage input, 4 inputs*2 |
|||
Memory card save input |
Voltage input*2 |
|||
Judgment/Binary output |
3-level judgment output: OUT1 to OUT16, total judgment output |
|||
Strobe output |
PNP open-collector output*2 |
|||
Trigger input enable output | ||||
Analog RGB monitor output |
SVGA (800 x 600 pixels) |
|||
RS-232C interface |
Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable) |
|||
USB interface |
In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible) |
|||
Ethernet interface |
1000BASE-T/1000 BASE-TX/10 BASE-T |
|||
Memory card |
SD card CA-SD4G (4GB), CA-SD1G (1GB) support |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption. |
1 head connected 480mA max./ 2 heads connected 550mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1,120 g |
|||
*1 1 or 2 units can be connected only with the same head model | ||||

Specifications
Model |
TM-CX10U |
|||
Max. connections |
Number of steps |
2 |
||
Cable length |
30 m 98.4' total (10 m 32.8' between devices) |
|||
Environmental resistance |
Ambient temperature |
0 to +45°C 32 to 113°F |
||
Relative humidity |
35 to 85% (No condensation) |
|||
Weight |
Approx. 60 g |
|||

Specifications
Model |
TM-H1*1 |
|||
Type |
Setup software for the TM-3000 Series |
|||
Operating System |
Windows 11 Pro |
|||
CPU |
Pentium III 1GHz or more (1.7GHz or more recommended) |
|||
Memory capacity |
512MB or more (1GB or more recommended) |
|||
Available hard disk space |
1GB or more |
|||
Display |
XGA (1024 x 768 pixels) or greater, 256 colors or greater |
|||
PC interface |
Includes one of the following*6: USB2.0/1.1*7 or Ethernet*8 |
|||
*1 Use this software in recommended environments according to your OS. | ||||


Specifications
Model |
TM-H1X |
|||
Supported OS |
Windows11 Pro / Windows10 Home/Pro/Enterprise *1 |
|||
Required free space on hard disk |
2 GB or more (with additional space for storing images required) |
|||
Display resolution |
1366 × 768 pixels or higher (1920 × 1080 pixels or higher recommended) |
|||
*1 • Windows® is a trademark or registered trademark of Microsoft Corporation in the United States and other countries. | ||||

Specifications
Model |
TM-MP120 |
|||
LCD panel |
Display element |
TFT LCD |
||
Display colors |
16 million colors |
|||
Number of dots |
1024 × 768 (W × H) |
|||
Effective display area |
245.7 × 184.3 9.67" × 7.26" (W × H mm inch) |
|||
Backlight |
White LED (non-replaceable); Life expectancy (normal temperature/humidity): Approx. 50000 hours |
|||
Interface |
Ethernet |
1 port on rear (1000BASE-T/100BASE-TX) |
||
USB |
1 port on front, 2 ports on rear *1 |
|||
Ratings |
Power voltage |
24 VDC ±10% |
||
Maximum current consumption |
2.5 A |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Structure |
Panel-embedded, IP65f (dust-/drip-proof) on front operating section |
|||
Weight |
Approx. 2400 g 5.29 lb |
|||
*1 Use USB cable OP-35331 (3 m 9.8') to connect to the controller. | ||||

Specifications
Model |
TM-X5000 |
|||
Number of connectable sensor heads |
2 |
|||
Number of setting registrations |
Up to 1000 settings (depending on SD card capacity and setting contents) for SD card 1 and SD card 2 individually. External switching is possible. |
|||
Memory cards |
• SD card slot × 2 |
|||
Number of configurable tools |
Up to 100 measurement tools and 100 element tools per head *1 |
|||
Interface |
Control inputs |
20 (Terminal block: 5, Parallel I/O: 15) |
||
Control outputs |
• 28 (Terminal block: 6, Parallel I/O: 22) |
|||
RS-232C |
Numerical value output and control input/output |
|||
PLC link |
Numerical value output and control input/output using Ethernet port |
|||
Ethernet |
• Numerical value output and control input/output |
|||
USB |
• Connection to KEYENCE dedicated monitor (TM-MP120) |
|||
EtherNet/IP™ |
• Numerical value output and control input/output using Ethernet port or optional EtherNet/IP™ unit CB-NEP20E |
|||
PROFINET |
• Numerical value output and control input/output using Ethernet port or optional PROFINET unit CB-NPN20EA (Cannot be used in conjunction with PLC link, EtherNet/IP™, and EtherCAT®) |
|||
EtherCAT® |
• Numerical value output and control input/output using optional EtherCAT® unit CB-NEC20E |
|||
SNTP |
Automatic date and time correction when connected to SNTP server |
|||
USB HDD |
Various data output, including image data, when connecting an HDD (2 TB max.) to dedicated USB port |
|||
Simple monitor output |
Analog RGB output, XGA (1024 × 768 (24-bit color, 60 Hz)) |
|||
Minimum display unit |
0.01 μm, 0.0001°, 0.0001 mm2 |
|||
Display language (Simple monitor output) |
Switchable between English, Japanese, Simplified Chinese, Traditional Chinese, Korean, Thai, German, French, Italian, |
|||
Ratings |
Power voltage |
24 VDC ±10% |
||
Current consumption |
3.5 A |
|||
Environmental resistance |
Ambient temperature |
0 to +45°C 32 to 113°F (when installed on a DIN rail) / 0 to +40°C 32 to 104°F (when installed on a surface) |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Weight |
Approx. 1600 g 3.53 lb |
|||
*1 Up to 7 master comparison tools (area/contour), 19 pitch measurement tools (distance/angle), 13 foreign particle distance tools (rotating rectangle), 8 foreign particle distance tools (circle/arc), and 7 profile extraction tools (depending on SD card capacity and settings). | ||||

Specifications
Model |
TM-X5006 |
|||
Transmitter/receiver distance |
60 mm 2.36" |
|||
Measuring range |
Field of view |
High-accuracy measurement area |
ø4 mm ø0.16" |
|
Measurement area |
ø6 mm ø0.24" |
|||
Depth of field |
High-accuracy measurement area |
2 mm 0.08" |
||
Measurement area |
4 mm 0.16" |
|||
Exposure time |
25/50/100 μs (Adjustable 3-stage) |
|||
Imaging time (Trigger interval) |
Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes) |
|||
Light source |
InGaN green LED |
|||
Measurement position accuracy |
High-accuracy measurement area |
±0.2 μm ±0.000008" *1 |
||
Measurement area |
±0.3 μm ±0.000012" *1 |
|||
Repeatability |
±0.03 μm ±0.000001" *2 |
|||
Pixel resolution |
Approx. 3.5 μm 0.000138" |
|||
Environmental resistance |
Enclosure rating |
IP64 *3 |
||
Ambient temperature |
0 to +45°C 32 to 113°F |
|||
Relative humidity |
85% RH or less (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter: Approx. 160 g 5.65 oz |
|||
*1 Error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
TM-X5040 |
|||
Transmitter/receiver distance |
180 mm 7.09" |
|||
Measuring range |
Field of view |
High-accuracy measurement area |
ø26 mm ø1.02" |
|
Measurement area |
ø40 mm ø1.57" |
|||
Depth of field |
High-accuracy measurement area |
10 mm 0.39" |
||
Measurement area |
20 mm 0.79" |
|||
Exposure time |
25/50/100 μs (Adjustable 3-stage) |
|||
Imaging time (Trigger interval) |
Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes) |
|||
Light source |
InGaN green LED |
|||
Measurement position accuracy |
High-accuracy measurement area |
±1 μm ±0.000039" *1 |
||
Measurement area |
±2 μm ±0.000079" *1 |
|||
Repeatability |
±0.08 μm ±0.000003" *2 |
|||
Pixel resolution |
Approx. 21 μm 0.000827" |
|||
Environmental resistance |
Enclosure rating |
IP64 *3 |
||
Ambient temperature |
0 to +45°C 32 to 113°F |
|||
Relative humidity |
85% RH or less (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter: Approx. 620 g 21.89 oz |
|||
*1 Error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
TM-X5065 |
|||
Transmitter/receiver distance |
270 mm 10.63" |
|||
Measuring range |
Field of view |
High-accuracy measurement area |
ø40 mm ø1.57" |
|
Measurement area |
ø65 mm ø2.56" |
|||
Depth of field |
High-accuracy measurement area |
20 mm 0.79" |
||
Measurement area |
30 mm 1.18" |
|||
Exposure time |
25/50/100 μs (Adjustable 3-stage) |
|||
Imaging time (Trigger interval) |
Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes) |
|||
Light source |
InGaN green LED |
|||
Measurement position accuracy |
High-accuracy measurement area |
±1.2 μm ±0.000047" *1 |
||
Measurement area |
±2.2 μm ±0.000087" *1 |
|||
Repeatability |
±0.1 μm ±0.000004" *2 |
|||
Pixel resolution |
Approx. 37 μm 0.001457" |
|||
Environmental resistance |
Enclosure rating |
IP64 *3 |
||
Ambient temperature |
0 to +45°C 32 to 113°F |
|||
Relative humidity |
85% RH or less (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter: Approx. 1300 g 2.87 lb |
|||
*1 Error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
TM-X5120 |
|||
Transmitter/receiver distance |
436.7 mm 17.19" |
|||
Measuring range |
Field of view |
High-accuracy measurement area |
ø60 mm ø2.36" |
|
Measurement area |
ø124 mm ø4.88" |
|||
Depth of field |
High-accuracy measurement area |
20 mm 0.79" |
||
Measurement area |
40 mm 1.57" |
|||
Exposure time |
25/50/100 μs (Adjustable 3-stage) |
|||
Imaging time (Trigger interval) |
Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes) |
|||
Light source |
InGaN green LED |
|||
Measurement position accuracy |
High-accuracy measurement area |
±2.5 μm ±0.000098" *1 |
||
Measurement area |
±3.5 μm 0.000138" *1 |
|||
Repeatability |
±0.2 μm ±0.000008" *2 |
|||
Pixel resolution |
Approx. 66 μm 0.002598" |
|||
Environmental resistance |
Enclosure rating |
IP64 *3 |
||
Ambient temperature |
0 to +45°C 32 to 113°F |
|||
Relative humidity |
85% RH or less (No condensation) |
|||
Material |
Aluminum/PBT |
|||
Weight |
Transmitter: Approx. 5900 g 13.01 lb |
|||
*1 Error when measuring width of KEYENCE standard object (glass calibration scale). | ||||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.