Specifications
Model |
SV2-LA5A |
|||
Type |
MECHATROLINK-III conversion cable (RJ45/IMI conversion) |
|||
Length |
0.5 m 1.6' |
|||

Specifications
Model |
SV2-M005AK |
|||
General specifications |
Applicable servo amplifier |
SV2-005L2 |
||
Rated output |
50 W |
|||
Rated torque |
0.159 N·m *1 |
|||
Instant maximum torque |
0.557 N·m |
|||
Rated current |
0.55 Arms |
|||
Instant maximum current |
2.0 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.316 N·m/Arms |
|||
Rotor moment of inertia |
0.0395 ×10-4kg·m2 |
|||
Rated power rating |
6.40 kW/s |
|||
Rated angle acceleration |
40200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.3 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M005AS |
|||
General specifications |
Applicable servo amplifier |
SV2-005L2 |
||
Rated output |
50 W |
|||
Rated torque |
0.159 N·m *1 |
|||
Instant maximum torque |
0.557 N·m |
|||
Rated current |
0.55 Arms |
|||
Instant maximum current |
2.0 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.316 N·m/Arms |
|||
Rotor moment of inertia |
0.0395 ×10-4kg·m2 |
|||
Rated power rating |
6.40 kW/s |
|||
Rated angle acceleration |
40200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.3 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M010AK |
|||
General specifications |
Applicable servo amplifier |
SV2-010L2 |
||
Rated output |
100 W |
|||
Rated torque |
0.318 N·m *1 |
|||
Instant maximum torque |
1.11 N·m |
|||
Rated current |
0.85 Arms |
|||
Instant maximum current |
3.1 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.413 N·m/Arms |
|||
Rotor moment of inertia |
0.0659 ×10-4kg·m2 |
|||
Rated power rating |
15.3 kW/s |
|||
Rated angle acceleration |
48200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.4 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M010AS |
|||
General specifications |
Applicable servo amplifier |
SV2-010L2 |
||
Rated output |
100 W |
|||
Rated torque |
0.318 N·m *1 |
|||
Instant maximum torque |
1.11 N·m |
|||
Rated current |
0.85 Arms |
|||
Instant maximum current |
3.1 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.413 N·m/Arms |
|||
Rotor moment of inertia |
0.0659 ×10-4kg·m2 |
|||
Rated power rating |
15.3 kW/s |
|||
Rated angle acceleration |
48200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
35 × |
|||
Approx. weight |
0.4 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M020AK |
|||
General specifications |
Applicable servo amplifier |
SV2-020L2 |
||
Rated output |
200 W |
|||
Rated torque |
0.637 N·m *1 |
|||
Instant maximum torque |
2.23 N·m |
|||
Rated current |
1.6 Arms |
|||
Instant maximum current |
5.8 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.444 N·m/Arms |
|||
Rotor moment of inertia |
0.263 ×10-4kg·m2 |
|||
Rated power rating |
15.4 kW/s |
|||
Rated angle acceleration |
24200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
15 × |
|||
Approx. weight |
0.8 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M020AS |
|||
General specifications |
Applicable servo amplifier |
SV2-020L2 |
||
Rated output |
200 W |
|||
Rated torque |
0.637 N·m *1 |
|||
Instant maximum torque |
2.23 N·m |
|||
Rated current |
1.6 Arms |
|||
Instant maximum current |
5.8 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.444 N·m/Arms |
|||
Rotor moment of inertia |
0.263 ×10-4kg·m2 |
|||
Rated power rating |
15.4 kW/s |
|||
Rated angle acceleration |
24200 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
15 × |
|||
Approx. weight |
0.8 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M040AK |
|||
General specifications |
Applicable servo amplifier |
SV2-040L2 |
||
Rated output |
400 W |
|||
Rated torque |
1.27 N·m *1 |
|||
Instant maximum torque |
4.46 N·m |
|||
Rated current |
2.5 Arms |
|||
Instant maximum current |
9.3 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.544 N·m/Arms |
|||
Rotor moment of inertia |
0.486 ×10-4kg·m2 |
|||
Rated power rating |
33.1 kW/s |
|||
Rated angle acceleration |
26100 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
10 × |
|||
Approx. weight |
1.1 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M040AS |
|||
General specifications |
Applicable servo amplifier |
SV2-040L2 |
||
Rated output |
400 W |
|||
Rated torque |
1.27 N·m *1 |
|||
Instant maximum torque |
4.46 N·m |
|||
Rated current |
2.5 Arms |
|||
Instant maximum current |
9.3 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.544 N·m/Arms |
|||
Rotor moment of inertia |
0.486 ×10-4kg·m2 |
|||
Rated power rating |
33.1 kW/s |
|||
Rated angle acceleration |
26100 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
10 × |
|||
Approx. weight |
1.1 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M075AK |
|||
General specifications |
Applicable servo amplifier |
SV2-075L2 |
||
Rated output |
750 W |
|||
Rated torque |
2.39 N·m *1 |
|||
Instant maximum torque |
8.36 N·m |
|||
Rated current |
4.4 Arms |
|||
Instant maximum current |
16.9 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.584 N·m/Arms |
|||
Rotor moment of inertia |
1.59 ×10-4kg·m2 |
|||
Rated power rating |
35.9 kW/s |
|||
Rated angle acceleration |
15000 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
12 × |
|||
Approx. weight |
2.2 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M075AS |
|||
General specifications |
Applicable servo amplifier |
SV2-075L2 |
||
Rated output |
750 W |
|||
Rated torque |
2.39 N·m *1 |
|||
Instant maximum torque |
8.36 N·m |
|||
Rated current |
4.4 Arms |
|||
Instant maximum current |
16.9 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.584 N·m/Arms |
|||
Rotor moment of inertia |
1.59 ×10-4kg·m2 |
|||
Rated power rating |
35.9 kW/s |
|||
Rated angle acceleration |
15000 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
12 × |
|||
Approx. weight |
2.2 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M100AK |
|||
General specifications |
Applicable servo amplifier |
SV2-100L2 |
||
Rated output |
0.85 kW |
|||
Rated torque |
5.39 N·m *1 |
|||
Instant maximum torque |
14.2 N·m |
|||
Rated current |
6.9 Arms |
|||
Instant maximum current |
17 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.859 N·m/Arms |
|||
Rotor moment of inertia |
13.9 ×10-4kg·m2 |
|||
Rated power rating |
20.9 kW/s |
|||
Rated angle acceleration |
3880 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
5.5 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M100AS |
|||
General specifications |
Applicable servo amplifier |
SV2-100L2 |
||
Rated output |
0.85 kW |
|||
Rated torque |
5.39 N·m *1 |
|||
Instant maximum torque |
14.2 N·m |
|||
Rated current |
6.9 Arms |
|||
Instant maximum current |
17 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.859 N·m/Arms |
|||
Rotor moment of inertia |
13.9 ×10-4kg·m2 |
|||
Rated power rating |
20.9 kW/s |
|||
Rated angle acceleration |
3880 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
5.5 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M150AK |
|||
General specifications |
Applicable servo amplifier |
SV2-150L2 |
||
Rated output |
1.3 kW |
|||
Rated torque |
8.34 N·m *1 |
|||
Instant maximum torque |
23.3 N·m |
|||
Rated current |
10.7 Arms |
|||
Instant maximum current |
28 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.891 N·m/Arms |
|||
Rotor moment of inertia |
19.9 ×10-4kg·m2 |
|||
Rated power rating |
35.0 kW/s |
|||
Rated angle acceleration |
4190 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
7.1 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M150AS |
|||
General specifications |
Applicable servo amplifier |
SV2-150L2 |
||
Rated output |
1.3 kW |
|||
Rated torque |
8.34 N·m *1 |
|||
Instant maximum torque |
23.3 N·m |
|||
Rated current |
10.7 Arms |
|||
Instant maximum current |
28 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.891 N·m/Arms |
|||
Rotor moment of inertia |
19.9 ×10-4kg·m2 |
|||
Rated power rating |
35.0 kW/s |
|||
Rated angle acceleration |
4190 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
7.1 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M200AK |
|||
General specifications |
Applicable servo amplifier |
SV2-200L2 |
||
Rated output |
1.8 kW |
|||
Rated torque |
11.5 N·m *1 |
|||
Instant maximum torque |
28.7 N·m |
|||
Rated current |
16.7 Arms |
|||
Instant maximum current |
42 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.748 N·m/Arms |
|||
Rotor moment of inertia |
26.0 ×10-4kg·m2 |
|||
Rated power rating |
50.9 kW/s |
|||
Rated angle acceleration |
4420 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
8.8 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M200AS |
|||
General specifications |
Applicable servo amplifier |
SV2-200L2 |
||
Rated output |
1.8 kW |
|||
Rated torque |
11.5 N·m *1 |
|||
Instant maximum torque |
28.7 N·m |
|||
Rated current |
16.7 Arms |
|||
Instant maximum current |
42 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.748 N·m/Arms |
|||
Rotor moment of inertia |
26.0 ×10-4kg·m2 |
|||
Rated power rating |
50.9 kW/s |
|||
Rated angle acceleration |
4420 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
8.8 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M300AK |
|||
General specifications |
Applicable servo amplifier |
SV2-300L2, SV2-500L2 |
||
Rated output |
SV2-300L2: 2.4kW, SV2-500L2: 2.9kW |
|||
Rated torque |
SV2-300L2: 15.1 N·m *1 |
|||
Instant maximum torque |
SV2-300L2: 45.1 N·m, SV2-500L2: 54.0 N·m |
|||
Rated current |
SV2-300L2: 19.6 Arms, SV2-500L2: 23.8 Arms |
|||
Instant maximum current |
SV2-300L2: 56 Arms, SV2-500L2: 70 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.848 N·m/Arms |
|||
Rotor moment of inertia |
46.0 ×10-4kg·m2 |
|||
Rated power rating |
SV2-300L2: 49.5 kW/s, SV2-500L2: 75.2 kW/s |
|||
Rated angle acceleration |
SV2-300L2: 3280 rad/s2, SV2-500L2: 4040 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
SV2-300L2: 3 ×, SV2-500L2: 5 × |
|||
Approx. weight |
13.5 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M300AS |
|||
General specifications |
Applicable servo amplifier |
SV2-300L2, SV2-500L2 |
||
Rated output |
SV2-300L2: 2.4kW, SV2-500L2: 2.9kW |
|||
Rated torque |
SV2-300L2: 15.1 N·m *1 |
|||
Instant maximum torque |
SV2-300L2: 45.1 N·m, SV2-500L2: 54.0 N·m |
|||
Rated current |
SV2-300L2: 19.6 Arms, SV2-500L2: 23.8 Arms |
|||
Instant maximum current |
SV2-300L2: 56 Arms, SV2-500L2: 70 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.848 N·m/Arms |
|||
Rotor moment of inertia |
46.0 ×10-4kg·m2 |
|||
Rated power rating |
SV2-300L2: 49.5 kW/s, SV2-500L2: 75.2 kW/s |
|||
Rated angle acceleration |
SV2-300L2: 3280 rad/s2, SV2-500L2: 4040 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
SV2-300L2: 3 ×, SV2-500L2: 5 × |
|||
Approx. weight |
13.5 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M500AK |
|||
General specifications |
Applicable servo amplifier |
SV2-500L2 |
||
Rated output |
4.4 kW |
|||
Rated torque |
28.4 N·m *1 |
|||
Instant maximum torque |
71.6 N·m |
|||
Rated current |
32.8 Arms |
|||
Instant maximum current |
84 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.934 N·m/Arms |
|||
Rotor moment of inertia |
67.5 ×10-4kg·m2 |
|||
Rated power rating |
119 kW/s |
|||
Rated angle acceleration |
4210 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
17.5kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV2-M500AS |
|||
General specifications |
Applicable servo amplifier |
SV2-500L2 |
||
Rated output |
4.4 kW |
|||
Rated torque |
28.4 N·m *1 |
|||
Instant maximum torque |
71.6 N·m |
|||
Rated current |
32.8 Arms |
|||
Instant maximum current |
84 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.934 N·m/Arms |
|||
Rotor moment of inertia |
67.5 ×10-4kg·m2 |
|||
Rated power rating |
119 kW/s |
|||
Rated angle acceleration |
4210 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
17.5kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
SV3-005L2 |
|||
General specifications |
Capacity |
50 W |
||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2 |
|
Control circuit |
Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2 |
|||
Allowable frequency fluctuation |
Main circuit/control circuit |
±5% max. |
||
Overvoltage category |
III |
|||
Control mode |
Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system |
|||
Feedback |
Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback |
|||
Operating environment |
Operating atmosphere |
Enclosure rating |
IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2 |
|
Pollution degree |
2 (in an IP54 or higher control panel) However, the product must be used in the following environments: |
|||
Operating ambient temperature |
-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher) |
|||
Storage ambient temperature |
-20 to +85°C -4 to +185°F (No freezing) |
|||
Operating/storage ambient temperature |
95% RH or less (No condensation) |
|||
Altitude |
No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher) |
|||
Vibration resistance |
4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6) |
|||
Impact resistance |
19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27) |
|||
Other |
No static noise, strong electric or magnetic fields, or radiation |
|||
Applied standard |
UL/CSA standards |
UL 61800-5-1, CSA 22.2 No. 274 |
||
CE marking |
Machinery Directive |
EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Structure |
Type |
Base mount installation |
||
Safety function |
STO function (STO/EN 61800-5-2) |
|||
Safety function |
Safety parameters |
SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015 |
||
Response time |
4 ms(max) |
|||
Input |
STO1, STO2: Power module base block signals |
|||
Output |
EDM: Built-in safety circuit status monitoring (fixed output) |
|||
Protection function |
Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc. |
|||
Min. insulation resistance |
500 VDC 1 MΩ or more with insulation resistance meter |
|||
Insulation withstand voltage |
1,500 VAC or more (between primary side and ground) |
|||
Weight |
Approx. 0.8 kg 28.22 oz |
|||
Power supply/current capacity and power loss |
Main circuit power supply |
Three-phase 200 V/Single-phase 200 V/DC 270 V |
||
Max. applicable motor capacity |
50 W |
|||
Power supply capacity for 1 amplifier |
Three-phase 200 V: 0.2 kVA |
|||
Output current |
Continuous |
0.66 Arms |
||
Max. |
2.1 Arms |
|||
Main circuit power loss |
Three-phase 200 V: 5.0 W |
|||
Regenerative resistor power loss |
― |
|||
Control circuit power loss |
12 W |
|||
Total power loss |
Three-phase 200 V: 17.0 W |
|||
Rated input current |
Main circuit |
Three-phase 200 V: 0.4 Arms |
||
Control circuit |
0.2 Arms |
|||
Rush current |
Main circuit |
29 A *3 |
||
Control circuit |
34 A *3 |
|||
Performance specifications |
Performance |
Speed control range |
1:5000 (Under conditions where load torque is equal to or less than rated torque) |
|
Speed fluctuation rate |
At load fluctuation |
0 to 100% load variation: ±0.01% or less (at rated rotation speed) |
||
At main circuit voltage change |
Rated voltage ±10%: 0% (at rated rotation speed) |
|||
At ambient temperature change |
Ambient temperature 0 to +50°C 32 to 122°F: |
|||
Torque control accuracy (reproducibility) |
±1% |
|||
Velocity frequency response |
3.1 kHz |
|||
Dynamic brake |
Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP) |
|||
Regenerative resistor |
Built-in regenerative resistor: Disabled at 50 to 400 W |
|||
Display Function |
Panel function |
7-segment LED |
||
Communication status indicator LED |
EtherCAT® communication: L/A × 2 |
|||
Servo functions |
Tuning |
Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc. |
||
Monitor |
Lifespan prediction, vibration, load factor, power consumption, temperature, etc. |
|||
I/O specifications |
Sequence input signal |
Number of inputs |
7 (3 high-speed inputs, 4 general-purpose inputs) |
|
Max. input voltage |
28.8 VDC |
|||
Rated input voltage |
24 VDC |
|||
Min. ON voltage |
19 VDC |
|||
Max. OFF current/voltage |
High-speed input: 0.1 mA, General-purpose input: 0.3 mA |
|||
Common point mode |
7 points/1 common (1 terminal) (bidirectional) |
|||
Input time constant |
250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
|||
Input current |
High-speed input: 4.4 mA, General-purpose input: 4.5 mA |
|||
Input impedance |
Approx. 5.1 kΩ |
|||
Assignable input signals |
All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL) |
|||
Sequence output signal |
Number of outputs |
4 |
||
Output mode |
Transistor NPN output |
|||
Rated load |
30 VDC/50 mA |
|||
Leakage current when OFF |
0.5 mA |
|||
Residual voltage when ON |
1.5 VDC or less |
|||
Common point mode |
Independent common |
|||
Assignable output signals |
Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR) |
|||
Analog Feedback Input signal monitor |
Max. input voltage |
±12 V |
||
Accuracy |
±1% of F.S. |
|||
Resolution |
±12 bits |
|||
Input impedance |
30 kΩ |
|||
Encoder division pulse output signal |
Output mode |
A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output |
||
Line driver |
SN75ALS174 (T.I.) equivalent |
|||
Output frequency |
1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5 |
|||
Analog monitor output |
No. of channels |
2 ch |
||
Output range |
±10 V (Linearity effective range: ±8 V) |
|||
Resolution |
16 bits |
|||
Conversion precision |
±20 mV (typ.) |
|||
Max. allowable load current |
±10 mA |
|||
Conversion speed |
1.2 ms (typ.) |
|||
Communication specifications |
EtherCAT® communication |
Applicable communication standards |
IEC 61158 Type12, |
|
Physical layer |
100 BASE-TX(IEEE802.3) |
|||
Cable |
Category 5 STP, 2 pair |
|||
Mailbox |
Emergency messages, SDO requests, SDO responses |
|||
Distributed clocks |
Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments) |
|||
Max. distance between stations |
50 m 164.0' |
|||
USB communication |
Connected device |
PC |
||
Communication standard |
USB 2.0–compliant |
|||
Function |
Status display, Parameter settings, Tuning, etc. |
|||
*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2. | ||||

Specifications
Model |
SV3-010L2 |
|||
General specifications |
Capacity |
100 W |
||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2 |
|
Control circuit |
Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2 |
|||
Allowable frequency fluctuation |
Main circuit/control circuit |
±5% max. |
||
Overvoltage category |
III |
|||
Control mode |
Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system |
|||
Feedback |
Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback |
|||
Operating environment |
Operating atmosphere |
Enclosure rating |
IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2 |
|
Pollution degree |
2 (in an IP54 or higher control panel) However, the product must be used in the following environments: |
|||
Operating ambient temperature |
-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher) |
|||
Storage ambient temperature |
-20 to +85°C -4 to +185°F (No freezing) |
|||
Operating/storage ambient temperature |
95% RH or less (No condensation) |
|||
Altitude |
No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher) |
|||
Vibration resistance |
4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6) |
|||
Impact resistance |
19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27) |
|||
Other |
No static noise, strong electric or magnetic fields, or radiation |
|||
Applied standard |
UL/CSA standards |
UL 61800-5-1, CSA 22.2 No. 274 |
||
CE marking |
Machinery Directive |
EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Structure |
Type |
Base mount installation |
||
Safety function |
STO function (STO/EN 61800-5-2) |
|||
Safety function |
Safety parameters |
SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015 |
||
Response time |
4 ms(max) |
|||
Input |
STO1, STO2: Power module base block signals |
|||
Output |
EDM: Built-in safety circuit status monitoring (fixed output) |
|||
Protection function |
Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc. |
|||
Min. insulation resistance |
500 VDC 1 MΩ or more with insulation resistance meter |
|||
Insulation withstand voltage |
1,500 VAC or more (between primary side and ground) |
|||
Weight |
Approx. 0.8 kg 28.22 oz |
|||
Power supply/current capacity and power loss |
Main circuit power supply |
Three-phase 200 V/Single-phase 200 V/DC 270 V |
||
Max. applicable motor capacity |
100 W |
|||
Power supply capacity for 1 amplifier |
Three-phase 200 V: 0.3 kVA |
|||
Output current |
Continuous |
0.91 Arms |
||
Max. |
3.2 Arms |
|||
Main circuit power loss |
Three-phase 200 V: 7.0 W |
|||
Regenerative resistor power loss |
― |
|||
Control circuit power loss |
12 W |
|||
Total power loss |
Three-phase 200 V: 19.0 W |
|||
Rated input current |
Main circuit |
Three-phase 200 V: 0.8 Arms |
||
Control circuit |
0.2 Arms |
|||
Rush current |
Main circuit |
29 A *3 |
||
Control circuit |
34 A *3 |
|||
Performance specifications |
Performance |
Speed control range |
1:5000 (Under conditions where load torque is equal to or less than rated torque) |
|
Speed fluctuation rate |
At load fluctuation |
0 to 100% load variation: ±0.01% or less (at rated rotation speed) |
||
At main circuit voltage change |
Rated voltage ±10%: 0% (at rated rotation speed) |
|||
At ambient temperature change |
Ambient temperature 0 to +50°C 32 to 122°F: |
|||
Torque control accuracy (reproducibility) |
±1% |
|||
Velocity frequency response |
3.1 kHz |
|||
Dynamic brake |
Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP) |
|||
Regenerative resistor |
Built-in regenerative resistor: Disabled at 50 to 400 W |
|||
Display Function |
Panel function |
7-segment LED |
||
Communication status indicator LED |
EtherCAT® communication: L/A × 2 |
|||
Servo functions |
Tuning |
Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc. |
||
Monitor |
Lifespan prediction, vibration, load factor, power consumption, temperature, etc. |
|||
I/O specifications |
Sequence input signal |
Number of inputs |
7 (3 high-speed inputs, 4 general-purpose inputs) |
|
Max. input voltage |
28.8 VDC |
|||
Rated input voltage |
24 VDC |
|||
Min. ON voltage |
19 VDC |
|||
Max. OFF current/voltage |
High-speed input: 0.1 mA, General-purpose input: 0.3 mA |
|||
Common point mode |
7 points/1 common (1 terminal) (bidirectional) |
|||
Input time constant |
250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
|||
Input current |
High-speed input: 4.4 mA, General-purpose input: 4.5 mA |
|||
Input impedance |
Approx. 5.1 kΩ |
|||
Assignable input signals |
All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL) |
|||
Sequence output signal |
Number of outputs |
4 |
||
Output mode |
Transistor NPN output |
|||
Rated load |
30 VDC/50 mA |
|||
Leakage current when OFF |
0.5 mA |
|||
Residual voltage when ON |
1.5 VDC or less |
|||
Common point mode |
Independent common |
|||
Assignable output signals |
Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR) |
|||
Analog Feedback Input signal monitor |
Max. input voltage |
±12 V |
||
Accuracy |
±1% of F.S. |
|||
Resolution |
±12 bits |
|||
Input impedance |
30 kΩ |
|||
Encoder division pulse output signal |
Output mode |
A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output |
||
Line driver |
SN75ALS174 (T.I.) equivalent |
|||
Output frequency |
1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5 |
|||
Analog monitor output |
No. of channels |
2 ch |
||
Output range |
±10 V (Linearity effective range: ±8 V) |
|||
Resolution |
16 bits |
|||
Conversion precision |
±20 mV (typ.) |
|||
Max. allowable load current |
±10 mA |
|||
Conversion speed |
1.2 ms (typ.) |
|||
Communication specifications |
EtherCAT® communication |
Applicable communication standards |
IEC 61158 Type12, |
|
Physical layer |
100 BASE-TX(IEEE802.3) |
|||
Cable |
Category 5 STP, 2 pair |
|||
Mailbox |
Emergency messages, SDO requests, SDO responses |
|||
Distributed clocks |
Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments) |
|||
Max. distance between stations |
50 m 164.0' |
|||
USB communication |
Connected device |
PC |
||
Communication standard |
USB 2.0–compliant |
|||
Function |
Status display, Parameter settings, Tuning, etc. |
|||
*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2. | ||||